Having problems with your Air Conditioners ?

Compressor turns on but not the fan.

\015 My most excellent AC stopped working one day. When we switch the knob to FAN ONLY nothing happens though you can feel some vibrations happening within. When we switch the knob to COOL, you can hear the air compressor kick on and the coils get cold. (*thanks)\015

Answers :

Jeannine, on this model there is one motor that turns both the evaporator and condensor fans. First you want to check to see if there is any obstruction preventing the fans from turning. There is also a dual capacitor that gives this motor a kick start. If this goes bad the motor will not run, just humm. Hopefully it is just your capacitor that has failed but it could be the motor itself. Part number for the capacitor is 16-05-00710-109. Part number for the motor is 50-11-t26p0-050. Usually a bad capacitor will show signs of leaking or bulging, but not always...Catriver..post back

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a Haier HWR05XC7 that will NOT work. The compressor turns on, but the fan won't work. The fan moves freely because I tried moving it with a screwdriver, but when I turn the unit on, the compressor kicks on, but no fan. I have been fighting with this thing for weeks and am about to chuck it out of the window. Also, the red error light stays on and there is nothing in the manual on how to troubleshoot it (other than making sure it is turned on and plugged in!). No support from Haier or Circ


HEY< If you start out having problems , what do you think the future of that unit will be! ... Haier Air Conditioners

I have a air compressor that I know the fan is bad in the outside unit. The compressor is not turning on. Yesterday the only way that the fan would run is with a push, now today it won't run at all. If the fan is not at full strength, will the compressor turn on. I want to know if I need a new air conditoner or is there hope in fixing this unit...


There is definitely hope in fixing this one as long as its just the fan not working. Carrier can easily fix it for you if you want. If you are looking for any more specific information, I would be glad to help but I will need the model number of the ... Carrier Air Conditioners

I have a Dometic rooftop Air conditioner in my RV When I turn it to low medium or high the fan run the same speed and when I turn it to AC it will run for about 5 min then the fan will shut off but the compressor keeps running I turn it off for a min or so and everythings comes back on. Turn it to the fan only side and the fan will run for 5 min then shut off a min later it comes back on then back off and on in fan only side.


Bad fan motor I suspect The windings are bad causing the motor to over heat sending the motor into thermal overload. would suggest the replacement of motor. Good Luck on repairs\015\012\015\012Dave ... Dometic Rooftop RV Air Conditioner

We turned on our 1.5 hp air con Fujita on the heat setting, the compressor would run but the fan would not work. The compressor became noisier so we turned it off. On the cool cycle the compressor ran and the fan but it did not seem to be cold. This unit is brand new.


The compressor got noisier be cause the head preasure was going up putting a strain on the compressor check all your wires from the fan motor and make shure they are all hooked up and than check the capacitor for the fan it may be bad usualy it will ... Air Conditioners

5,200 BTU unit. Compressor and fan both work when first turned on, then compressor quits after 5-10 minutes of operation. Won't turn on again even after 5-minute fan-on cool down. Process repeats after AC unit has been turned off for 10 minutes and re-started. Is this worth trying to fix, or should I replace the whole unit?


This could be just a simple fix of cleaning the condenser coils. If semi-clogged, it can cause higher than normal pressures and cause the compressor to cut out on it protector. Check it out. ... Air Conditioners

Hi there, iwant some help in duct type air condition (trane)60000 BTU .when i was gave the out door freon i recognized that the high pressure fans were off and the compressore was on ,so i turn off the air condition for seconds then turn on i found that the high pressure fans run for one minute and then turn off and the compressore still running ,so what i shell do????


I hate to say this but it sounds to me like you need a professional. You may hear some other advice but it's not safe for anyone to work on the outside compressor unless they really know what they're messing with. The fire and death by electrocutio ... DeLonghi Trane 5t Rooftop Air Conditioner Ycy060g1m0ad

I have a Carrier 5 ton Air Conditioner -five years old. I turn on the thermostat and the blower comes on in the house then the compressor engages, but the fan does start. I can manuelly, start outside fan by using a long screw driver to turn the blades. Then the fan begins to turn slowly until it reach a faster speed. But I do not beleive that the fan is turning as fast as it use to. I go back into the house and after 15 to 20 minutes the temperture has not dropped. It apprears to stay a th


... Carrier 38CKC030 Air Conditioner

My fedders aircon compressor does not turn on again whenever its thermostat turns it off. what i had to do is unplugged the power cord and turn it on again to work. i already replaced the capacitor. what i observed is that the big normally open rely does not switch on. maybe a board problem? if i turn it off and turn it on again, only the fan rotates and not the compressor. i had to unplug the power and put it back again for the compressor to run again.


You have a time delay build in on the pc board of 3 minutes. If it takes longer than 3 minutes check your compressor overload protector, Maybe the compressor is overheating, check your coils for proper air flow. ultimately if the compressor checks ok ... Fedders A6X05F2D Air Conditioner

Turn the unit on, the fan runs, and when the compressor tries to start the fan slows down and the compressor will not run. After a few seconds the fan speeds back up. I put an amp meter on the compressor lead and when it tried to start I registeres 41 amps. Is this a compressor or capacitor problem?


Sounds like you have a bad capacitor, if it's not tripping the breaker it doesn't sound like the compressor is drawing LRA unless the breaker is oversized for the condenser. ... Air Conditioners

I have an Amana Prestige A/C compressor that is not turning on when my fan turns on to cool the house. I replaced the capacitor because my old one was bubbled up at the top. After I replaced it, it still did not kick back on when I turned on the A/C unit from inside. There is an override switch on the compressor that turns the compressor on manually but does not stay on.


... Air Conditioners

I have a 1988 Prowler TT with a Coleman TSR Mach3. I've installed a new blower motor.The fan side works fine on high and low but when i move the selector to High Cool the compressor does not turn on..however when i move the selector to Low Cool the compressor turns on and it cools for a few seconds then locks up..now fan no cool air. Any ideas?? Is there a way to change/add oil to these units? Thanks, Hot in Alabama


... Coleman Mach 15 Air Conditioner

Hello I have an LG window unit, model LWHD8000RY6 I hooked it up yesterday after having it in storage for the winter- dry, clean storage in my basement. It worked for about 2 hours, then the compressor turned off. The fan still runs, all of the display lights & switches function. I can hear the compressor trying to turn on, but it gives a quiet click-hum and then stops. The fan is still running, but no cold air. Any ideas?


... LG BG8000ER Air Conditioner

My AC My Compressor keeps kicking off. I turn the unit on, the fan works. The Heat works but the compressor turns in about 60 sec. If I unplug the unit and turn it back on, it comes on but the compressor shuts off again after 60 sec. Can this be from dirt in the coils? They have some build up. Any other causes?


One might think so, YES the compressor is running till it gets hot and tripps on hi-temperature, and after it cools down awhile, the switch willcautomatically reset itself and back- & forth......Thank-you-very much! ... GE Zoneline AZ38H12DAD Split System Air Conditioner

Problem I turned on my air conditioner this spring. I turned the switch to cool on and the air conditioner fan not going. I took cover off and got new capacitator didn't work. I took fan motor into electric shop and checked out fine. When I turn switch on the contact switch engages and there is a humming noise. But the fan does not work. the compressor doesn't start up. The model is at least 10 years old. How do we tell what the SER rating is?


Hi,\015\012There are two things to check....\015\012\015\012Do you have power coming into the contactor???\015\012\015\012Do you have power coming out of the contactor???\015\012\015\012If you have power goin ... Air Conditioners

Turned on the a/c for the first time this year and no fan. The compressor turns on but no fan. The fan works when turned to heat and t-stat cranked up. This is a BDP CO. 2085C02135. Is there a relay or limit switch that only works with cool?


Depending on the thermostat you have, there may be an issue there. Some stats have a subbase that controls the fan for AC. I would like to know the model of your stat ... Air Conditioners

I have the MR36TQY3f outdoor unit with 2 MW09Y3FM units and 1 MW12Y3FM indoor units! The MW12.. works great and one of the MW9... works great! When I run the 2nd MW9 only (other MW9 & MW12 off)..... the outdoor unit compressor or fan does not come on! If I run all units then ... compressor kicks on runs great, fan runs... lines get cold on the 2 good units ... nothing on 3rd unit... then I turn 2 good units off....and it sounds like the compressor kicks off and the fan will continue to run reall


After looking at the manual for the units, I believe that the system is having trouble with the number of units that you have linked. Here is a portion of the manual about multi system operation>Also link to manual:http://www.fri ... Friedrich MR36TQY3F Split System Air Conditioner

EMERSON FAN MOTOR WHICH HAS A BLK WIRE PURPLE WIRE AND A BROWN WIRE WENT DEAD. SO I BOUGHT A NEW FAN EMERSON CAME WITH 4 WIRES BLK ,WHITH, BR AND BRW AND BRW WITH WHITE STRIPE. I WIRED IT BLK TO THE CONTACTOR WHITE TO THE COMM THE YELLOW FROM COMPRESSOR TO THE HERM BRW TO THE FAN BRW WITH WHITE STRIPE TO THE COMM THERE IS A RED WIRE GOING FROM THE COM TO THE CONTACTOR WHEN I TURN THE AC UNIT THE COMPRESSOR COMES ON PUT FAN DOES NOT ?????


The two brown wires go to the fans capacitor. The capacitor should always be changed with the fan motor.\015\012\015\012It sounds like your unit has a dual capacitor. One side for the fan and the other for the compressor. All you will be ... Dometic Rooftop RV Air Conditioner

A/c comes on and works fine for about thirty mins then outside fan cuts off and you have to eighter turn off the mains or turn thermostat up to cut off compressor you can not turn thermostat to off and get compressor to turn off


Check the compressor relay for sticking some bard units if it is a package unit were bad for this ... Air Conditioners

Compressor does not run. On turning the AC on, the compressor does not run. The blower fan does though. Checking the relay panel, the relay for the compressor does not engerize. a temporary solution is to put a switch across the contacts the compressor on and then the thermostate is set so that the AC should work, the fan comes on and the unit works as usual. The only exception is that the temperature must be controlled manually.


Hi, if you are energizing the contacts on the contactor, and the compressor runs, the thermostat is faulty. This is what energizes the contactor coil that you have. You need to check to see if you have voltage to the coil on the contactor. You need t ... Coleman Mach 15 Air Conditioner

When i was tested an air condition (trane 60000BTU duct type )i noticed that the high pressure fans of the out door unit were turned off and the compressor was running ,so i turned off the ac from thermostat for a second then turned on ,and look for the out door unit. I discovered that the high pressure fans turnned on for a one minute and then stopped, but the commpressor still running . What should i do ???/PLZ


... Air Conditioners

I have a goodman 4 ton central ac unit. The fan blower turns on but the compressor will not turn on. I replaced the capacitor and verified the compressor is receiving power. My question is a goodman compressor hard wired on the bottom or will I be able to easily checked The wires on the bottom of the compressor ?? Thank you for Any help you can provide Thanks again


Hello, you can Ohm the compressor windings with a multimeter. Just kill power the the unit, remove the wires from compressor and check each winding. You should have resistance, if not the windings are open and compressor must be replaced. ... Air Conditioners

A c dosent work,it has s slight humming sound fan dosent turn ,try to turn the fan and afeter turning it with a smallstick it started to run but dosent hear the compressor running


Hello,\015\012\015\012 \015\012 Check\015\012 to see if there is power getting to the air conditioner. If it is a \015\012110-volt unit, plug a lamp or other device into the same outlet the air \015\012conditio ... Carrier 38CKC036 Air Conditioner

The ac is not fully turning on. It sounds like the compressor starts to run, but the fan does not and eventually turn off. With the unit off, i turn the fan on and it sounds like its trying to run but its not. Any ideas?


The first thing you should do is make sure the fan turns freely by hand. If it does then check the capacitor and replace it if it's bad. If the fan doesn't turn freely then you may need a new fan. ... Dometic Rooftop RV Air Conditioner

I have the Nano Max cfi 14000e. Worked good for 5 years 3 months. When turned on seems as if compressor comes in, fan goes high and compressor kicking out and fan back to low. No signs of any fluid leaks, is this a staarter relay type problem, bad compressor.


... Amcor 14000 Portable Air Conditioner

Compressor intermittent Compressor doesn't always come on. Sometimes I have to turn system on and off several times, Uses Duo-Therm 4 button thermostat. When it is working with fan on high, if I reduce speed of fan, compressor will stop.


Sounds like a bad thermostat. Make sure you turn off all related breakers and disconnect switches before attempting to replace it. Good Luck! ... Dometic Rooftop RV Air Conditioner