Having problems with your Air Conditioners ?

Will not start

\015 Plugged in AC and it's won't turn on. There is power at the outlet....I've checked. The temperature is set at the coldest setting and room is warm so that's not the problem. I've tried the test button and reset button. Nothing works. My AC is actually AWF05XC5-T.\015

Answers :

One thing you can try is to hold down on the power button and plug the unit in. Hopefully you will hear a "beep". Then you need to unplug it for a minute and plug it back in. \015\012\015\012This is a known procedure to clear error codes from the control computer on units similar to yours, so it might possibly work. \015\012\015\012Something else you can do is download and look through the Users Manual for your model, which is at this URL: --> \015\012\015\012http://www.haier.com/products/product.asp?proID=3632 \015\012\015\012\015\012Hope that helps! ;)

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Contactor not engaging to start condenser unit . When setting the thermnostat, i hear the click from the unit starting inside the house. Fans start and air starts blowing inside the house, but the condenser unit never starts. I tryed pushing the contactor by hand and then everything works find (cool house) as long as i keep the contactor pushed manually. Seems alike the 24 V (coil) bobine in the contactor is not been energize. When I tried the 24 V outside with a 24 V surce it worked fine. Thank


I would replace the contactor if you are getting 24 volts to the contactor and it isn't engaging therefore the magneto on the contactor is out and the contactor will need replacement. If you don't have 24 volts at the contactor then the transformer ... Air Conditioners

Furnace fan won't turn on sometimes. The fan will start and when house reach set temperature, fan turn off, and will not start again. On the control panel I move the switch from Auto to On and hear a loud noise for about 3 sec. fan will not start. I will wait for about two hours and the fan start right up. I have to do this each time.


... Air Conditioners

I have a goodman 2,5 ton outside unit, i cant get the compressor to start even with replacing the start capacitor and using a super start on the compressor side of the capacitor? normally i wouldnt have a problem with this kind of repair but im getting power feed back through the cooling fan motor even with it unhooked from the start/run capacitor enough to start the fan slowly. i havent seen this before


Check to make sure you have 220 on both sides of contactors, double check wiring at capacitor. you can also check continuity between all three post at compressor , make sure power is off and wires are disconected, if you do not get continuity between ... Goodman CLQ36AR49 Air Conditioner

My fan will not start, if I take a stick and spin it it starts. I have replaced the fan motor, capacitor and start relay. Even bypassed the start relay, all have same problem. I had 2 cousins that have been in the HVAC field for 20 plus years each and they dont know the problem.


Supply the fanmoter from a completely seperate source of power and confirm that it is working. If it works, look at your supply board and contactor relay if there is one. ... Air Conditioners

The motor compressor of air-condition cant start what will i do? do i have to add a starting capacitor? to help to start the motor compressor of air-condition? how do i tap the starting capacitor to motor compressor?


First thing to do is to check the capacitor if you have a meter to check it would be great if the capacitor is good check the motor windings using a continuity test with your meter then you if you have to change your compressor or your capacitor ... Air Conditioners

I have a 2 year old Goodman GDS80703ANA furnace that has always had a problem starting. Sometimes it starts on the first attempt but other times it takes 2 or 3 attempts. This is what I see happening: The Induced Draft Blower starts and runs- the Igniter will glow for a few seconds and just as the igniter starts to stop glowing I hear the Gas Valve click and open but it is too late. On the next attempt or so, the Gas Valve will open sooner and burner will ignite. My question is: Is the Integrate


The board controls the timing ... Air Conditioners

I installed my attic fan about 10 years ago. Now, it will not start without me giving the blades a push. It hadn't been lubricated since installation. So I applied some 3-in-one oil. Still wouldn't start on it's own. Then I tried some WD-40 and it would start better. But then, not running overnight, again it wouldn't start without giving the blades a spin. Any suggestions?


Hi,\012The capacitor has gone bad... that is what gives the motor the "kick" to get it started...\012replce that and you are good again..\012\012heatman101 ... Air Conditioners

HI........... WHEN I START My AIR CONDITIONER TCL TAC12CS/J IT BEEPS 3 TIMES AND THEN SHOW ERROR CODE e2 BLINKING ON THE SCREEN AND THE REMOTE OF MY AIRCONDITIONER IZ NOT WORKING AND WHEN I START BY PUSHING THE START BUTTON IT START ANF AFTER 20 TO 30 MINUTES IT STOPS AND WIINGS of my air condition ARE OFF SO PLZ PLZ SOLVE MY PROBLEM PLZ


... Air Conditioners

My air conditioning unit wont start we usually start it with the remote but its not working it. it keeps flashing a symbol up the top when i try to turn it on but it wont start it. how can i fix the remote because i really need to get it started. the remote control unit model is: AR-DB5.


... Fujitsu 36CS Air Conditioner

The fan on outdoor unit sometimes starts normally, sometimes starts slowly and will get up to speed with a push or sometimes will not start at all. Loud hum when slow or stopped. Cools normally when it will start. Have replace capacitor. Any ideas?


SOME MODELS HAVE A TEMPERATURE DEVICE THAT CONTROLS THE FAN WHEN REAL HOT IT WILL CONTROL THE SPEED OF THE FAN WHEN COOL OUT THE FAN WILL VERY FROM FAST TO SLOW DEPANDS ON THE HEAT BEING PUT OUT BY THE OUT SIDE UNIT IF THIS PROBLEM OCCURES DURING BOT ... Air Conditioners

Tempstar 5000 This spring I turned on my air conditioner for the first time and it would not start at all... The fan did not turn on either. I turned off the main 220A breaker and puller the control fuses and put everything back and the unit started working fine. now fast forward to yesterday... house started feeling warm so I did the same thing... Tripped the breaker. Pulled the control fuses, and this time made sure I had new batteries in my thermostat. Started to work again. All was good. pus


... Air Conditioners

Furnace starting Lennox furnace model G6OUHV(X) series. Furnace would not start heating cycle unless I ran thermostrat temmp. setting up and down. Most times it would than start heat cycle. If not I would shut main power switch on furnace, wait a few seconds and then the furnace would start the heating cycle. I suspected the thermostat so beofre purchasing a new one I installed the old from my privious Lexxon. It now seems worse than ever. I either move the set points up and down (sometimes it w


Hint number 1, get HVAC license. One mistake or misunderstanding and you could blow your house up. ... Air Conditioners

We have a 2000 Winnebago Adventurer with basement air, "true air". Yesterday our AC unit started making a loud buzzing noise about every 90 seconds. Like maybe the second compressor was trying to start up and couldn't. We turned the AC off for awhile, and when we started it up again the noise started immediately. It buzzes for maybe 10 seconds. What can we try ? Should we leave it turned off ? It is over 100 degrees here in Texas and we need help fast!!! Thank you. Pam


... Coleman Air Conditioners

The blower is on but the heat is not coming out. After leaving as is it start coming out then after the house is warm and U decide to turn it down again blower is on but heat is not coming out. Sometimes it can take up to 8hrs before the heat starts coming out. The heat is perfectly fine when it starts coming out. Another thing is when we adjust the heat it the blower is on but the heat is not coming out holding the temperature at 77 degrees seems to be the sweet spot. Thermostat appears to be o


Jump out t-stat is first test ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

Coleman mach fan runs fine but A/C hums intermittently like it wants to start but won't. I'm running it with a Honda 2000 generator. Generator ran out of gas, when I restarted the generator the A/C would not run - stalls out the generator. I replaced the start and run capacitors on the A/C, hook up the generator and it ran fine until the generator ran out of gas. The A/C would not start up only hum intermittently - same problem as before replacing capacitors. Waited several hours with the fan on


The issue with the generator that gets low and high when it start running out of gas that effect the A/C and result of high voltage getting to the unit and burn the capacitors and it should by saved by the fuse make sure that the gen not run out of g ... Coleman Mach III Air Conditioner

YORK CONDENSING UNIT MODEL H1RA042506D WIRING SCUMATIC BLOWER MOTOR WILL NOT START WITH OUT A PUSH. START COMPASITOR MAY BE BAD BUT WITCH ONE IS IT. MOTOR NAME PLATE CALLS FOR A 370MFD. I FOUND A 36MFD WITH A BOOSTER COMPASITOR BUY THE START RELAY.


The capacitor for the fan will read 370uf 5 uf. The 370 is voltage at cap. My guess would be a 7.5 uf cap for your fan. If you read the cap. it will tell you size. Fan caps go between 5 and 20 uf or microfards. Easy to replace you can do it yourself. ... Air Conditioners

My Mach3 coleman ac compressor hums but wont start. trips breaker. I replaced the start capacitor with a hard start. still wont run?


Unfortunaletly the hartd start is a "last resort" and you will probably need to replace the compressor/unit... (however I have had luck physically jarring the compressor during the instant I applied power to the compressor.. sounds silly, but I have ... Air Conditioners

Interherm Model mmhb-09oabhp-06 During cold and on windy days the main blower starts then pauses, starts again and pauses, starts again and pauses, then finally turns on and runs.


The motor is working hard on start-up. could be the capacitor is going bad I would start with the capacitor and if that doesn't fix it the motor is prolly going to have to be replaced. ... Intertherm P3RA-048K Air Conditioner

Vulcan Comfort Control Central Heating unit - Our heater is situated outside and is ducted under the floor and operated by a remote control. When we activate the remote we can hear the unit starting up and have also witnessed the glow of the pilot light starting but the heater fails to start. I have had the technican three times and they cannot diagnose a problem - we have no heater at present - please help


... Air Conditioners

I have a Carries Mod# 24ABR348G510 Condenser unit. The system start with a normal cycle for about Three min, I've timed this to be this way every time the system is started. After the Three minutes the contacts starts to chaters. The 24 volt control voltage is up and down the scale and the condenser unit thin stalls and shuts down? I have Twelve of these units to keep maintained. The head is to be OK and the system is clean and the Thermostat checks out to be OK.


Hi,Did you already check the exhaust or the motor unit, the possible that has problem on there was the electric contactor, this was the switch the make the main motor to power, if this one was faulty it will have a problem just like the o ... Air Conditioners

Hi I have a Fujitsu Split system. As of recently it has started to mysteriously started to flick over from heating to cooling on its own. It is a 2.5KW unit and heats rather well. ALl of a sudden you hear the outside unit turn over and it starts to cool instead of heating. Any reason why it might be doing this. Please HELP !!!!!!


Yes i can! The mode of operation (MASTER CONTROL)has been set to AUTO instead of HEAT. Easy mistake and very simple to fix. Press the MASTER CONTROL button until HEAT is display on the LCD. I hope that this helps I take the time to answe ... Fujitsu 18R1 Air Conditioner

I have a dometic roof air on my RV, The start capacitor melted, i just received a new one from dometic,i orded the quick start kit,do it came with a start relay small black box that i dont remember seeing on my a/c unit, i do not have a generator, so do i still need to add that extra part?


Yes. Use all the replacement parts. Your compressor is hard starting due to increased tork and wear. That is what burned out the original cap. ... Dometic Rooftop RV Air Conditioner

We have a York (ceiling mount) air conditioner that has been shutting down 15-30 minutes after it has been turned on. At first, my husband thought it had something to do with a sleeper timer and started working around the "timer". It started working fine. A month ago it started doing the same thing (shutting down after 15-30 minutes) and we haven't been able to fix the problem since. We bought our house with two York units installed and the previuos owner took the owner's instructions with her,


A. You can write or all a York authorized dealer or The YORK plant itself , theres one one the east coast in Pa, near philly or go internet to find the nearest service place or dealership and ask them f the could send you new manuals . as a certifie ... Air Conditioners

Blower does not turn on bottom squirrl cage carrier weathermaker ignitor works pilot starts flame comes top fan starts - runs for 3 minutes then bottom squirrl cage does not start up. fuse on board good? do i need to replace motor?


Sounds like it to me. You might be able to switch the motor speeds by taking the red wire off the heat spot on the board and taking the one that is on the park and switching them. But more then likely the blower is bad replace the capacitor at the ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

Carrier central air 38ckc060301 problem, unit will not start, air handling blower runs, can hear hum at outdoor unit. I turn the unit off at themostat. let sit for ten minutes, turn back on at themostat, unit starts and cools. Will run through serveral cycles and then not start until I repaet process, any thoughts?


... Carrier Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific