Fan setting only works

\015 The fan only setting on my thermostat works but when I switch the setting to auto it will not blow air through the vents.\015

Answers :

Bad thermostat or open thermostat wire can cause this condition
Air Conditioners have a fan speed relay built in the unit, faster for cold air and slower for warm heated air. It is very possible that your relay is defective

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

My fan stopped working, but i hear the refrigeration unit working. is there something i can do to fix this? i cleaned out the filter, that didnt do anything to the issue. when i have it set to just fan mode, nothing works. but when i set it to high AC i can hear the ac unit working but no fan movment, so im assuming its the fan that is the issue.


Yes , you may have to change your fan and it should work . seems your fan went up on your a/c .. ... Haier HWC05XCB Air Conditioner

I have a Hampton Bay ceiling fan with remote. Only the fan works on HIGH. How do you reset remote so it works on all settings? The says set F/C on the back with fcc ID:CHQ8BT7096T. On the front from top to bottom , Left to right. The remote has a digital screen. Then a button labeled fanauto, a blu button with a fan then a for/rev button. The next row of buttons are a timer, green button with a light and then one with light delay. The last row of buttons has 2, one up one down with label Temp./


Seems like the remote doesn't work. Change the batteries. Verify the switch settings in the battery compartment match the setting of the switches on the very top of the fan itself.\012 ... Air Conditioners

My Honeywell ducted heating at home isn't working. I have set the on/off times for the week and set it to turn on automatically but nothing happens. I think the system is connected to the gas system outside (although I'm not 100% sure) and the gas water heater works so I assume the pilot light is working OK. Perhaps the fan or the fan motor has conked out? Any advice welcome! Thanks


Its the thermostat problem .so its not heating .the thermostat is either cracked or dusty or needs readjust ment,\015\012thanks.\015\012 ... Honeywell Air Conditioners

I have a heil -- model NUGK100DH12-- problem is when power is supplied to it the blower fan comes on right away along with the induction blower and it does have the electronic pilot which all works to thermostat setting. when setting is reached the flame shuts down normally and I think the induction motor cycles correctly, but the blower motor never cycles off. It's on constantly. I tried replacing the fan relay to no avail and am considering replacing the timed fan controller as the next move


... Air Conditioners

Hi i recently purchased a used convair portable supacool 9 air conditioner the first time i switched it on it appeared to work ok but the next time i turned it on it is working on normal fan mode but when i turn it to air conditioner mode it is doing exactly the same as on normal fan mode the compressor does not appear to be working and is not making the extra noise that it was the first time i have tryed all the switchs including the thermostat but there is only a very simple to use set up any


... Convair Portable Air Conditioner

My LG Lan125HV works fine on air conditioning ( cool) but heat pump does not trigger when I move to heat or combined settings. Tried all temperature and fan settings, tried waiting to see if unit waiting so as not to blow cold air, nothing works. Switch back to cooling and everything works fine.


I talked to LG customer support (800) 243-0000. The tech told me that this model had a problem with the indoor thermistor. It doesn't fail with an open-circuit condition, so you don't get an error code. The thermister just goes out of range and be ... LG Heat cool Window Air Conditioner

Amcoraire Bought an Amcoraire mini split ductless system in NOV 10 for a new home project we are building. I completed all the installation work and hired a HVAC technician to do the final install work. Everything went fine until we turned on the power and set the AC to the lowest setting on both units. Fans came on and louvers started working, but compressor would ramp up and run for about 30-40 seconds and then shutdown. Error code of FC was displayed on both indoor units. I called the place I


... Reddy Air Conditioners

I can't get my a/c to work. I have a totaline residential thermostat P/N P374-1700. I set the thermostat to cooling only and set the temperature to 72 degrees and while the house is 75 degrees and the green light goes on, nothing happens. The fan doesn't run either. I have HVAC on both the lower floor of the house and a separate station on the upper floor. The upper floor station works. The lower floor station worked fine earlier today, but nothing now. Any suggestions.


... Carrier Air Conditioners

I recently installed a new thermostat. The switch settings are not functioning properly. With the Heat/cool switch on heat and the fan switch on auto the fan works. With the fan switch set to run and the H/C switch off nothing runs.


Good day,You did not say what type of heat, and I'll assume it's not a heat pump.Standard wiring should apply here.4 wires at the thermostat should control all functions normally.Red is the power source from the transformer ... Air Conditioners

My new Hampton Bay window fan no longer works at the highest setting. It will work on settings 1 and 2 but will stop spinning when I set it to 3. Is there a way to fix this? Thanks!


This should still be under warranty, sound like a bad, speed switch,or better yet, take it back for anouther one! ... Hampton Bay Air Conditioners

The compressor works. The fan seems stuck. If I take the covers off and spin the fan, it works. If I put the setting on auto the fan won't start up. Any suggestions?


Sounds like the capacitor for your fan is shot. This is a very inexpensive part and will cause the fan to act just as you describe. You can check it with a multimeter that has the capacitor check function. Take the old one with you to get the new one ... Coleman Mach 15 Air Conditioner

My bonaire evaporative cooler cycles from high to low fan speeds when set in the cool mode. It works fine at the required speed setting when just the fan (no water) is selected. It also dumps water immediatly the cooling cycle is turned off rather than holding it for about 40Min as it should. Sounds like a controller problem, but I'm not sure if it would be the touch pad or the board up on the roof mounted unit.


... Air Conditioners

Hi Guys, I work on a mine site and the temperature on my Mitsubishi model MSZ - 25GEVA split air con has been set and I cannot change it via the remote control. In any mode i.e. cool/ heat if you push the temperature buttons nothing happens. The remote works fine ON/ Off/ Fan etc but they've locked the temperature so it can't be changed. Even if I push the reset button the temperature still remains pre set. I'm of the thought that I might need to remove the batteries and hold done specific bu


... Mitsubishi MSZ09UN Air Conditioner

All of a sudden the air conditioner no longer cools, with hif=gh or low thermostat settings. The fan for "Fan" and "Cool" settings works normally


Sounds like the outdoor unit is not working check breaker and then the capacitor ... Maytag M3X05F2B Air Conditioner

Model(MC42B-1A) The unit stoped working. Now it will not come on. There is 240v at the outside unit. When the contactor is pushed in manualy it starts and runs untill released. Filters are new, thermostat is set below room temp. Settings are on cool, fan(auto). Tried to switch fan to manual and it did not come on. Swithced it over to heat and it still did not come on. All breakers are good. I am at a loss. Why will my unit not come on and run.


Hello. It appears that your thermostat is bad. Change it and you should be up and running again. J. ... Air Conditioners

Compressor does not run. On turning the AC on, the compressor does not run. The blower fan does though. Checking the relay panel, the relay for the compressor does not engerize. a temporary solution is to put a switch across the contacts the compressor on and then the thermostate is set so that the AC should work, the fan comes on and the unit works as usual. The only exception is that the temperature must be controlled manually.


Hi, if you are energizing the contacts on the contactor, and the compressor runs, the thermostat is faulty. This is what energizes the contactor coil that you have. You need to check to see if you have voltage to the coil on the contactor. You need t ... Coleman Mach 15 Air Conditioner

My AC unit ouside the house works,but the fan inside the house does not work. It does not come on any more, not even when I change the fan setting from Auto to On.


Check the breakers first they are probly on seperate breakers if thats not the problem your fam motor may have over heated and need to be reset or replaced after being tested ... Hitachi RAS-09UH Air Conditioner

I am puzzled. Nothing was working with the Ruud unit. The fan was not coming on while setting was set to auto or on. the condenser fan was also not coming on. I traced back to the transfomer and there was no low voltage coming from transfomer though the two legs of 120v were going into the 240v and common leads. I changed the transformer with a 120/208/240 to 24v transformer and saw the same results. I thought well maybe I bought a bad transformer. I picked up a nother transformer from a


You said you have 120 vac but then you say you have it connected to the 240 v and common legs. If you have 120 v going to the transformer you should have it connected to the 120 v and common legs. Before you reconnect the transformer use an ohmmeter ... Ruud UBHC Air Conditioner

Carrier ac fan works when remote is set to fan. When set to ac it come on for a few seconds then the unit shuts off. The filters are clean. I took the top cover off and there are no leaves bees etc plugging anything up.


You have an electrical short or need capacitor replacement because when you set to cool compressor tries to star but take more current then trips. ... Air Conditioners

No cooling heat works good the fan does not seem to work on high when it's set to high the compressor ramps up and then slows down running amps are a 6amps design for 9amp. It's 410 refrigerant and I


Check your freon levels or have a tech check them ... Air Conditioners

Amana gas fired warm air furnace. Blower (fan) works fine when thermostat set simply to "fan". When selector is moved to "heat", burner fires nicely but teh circulatior blower fan does not kick-on. Any suggestions?


Either bad run cap on motor or bad blower motor ... Amana Air Conditioners

I have an LG mini split ac / heat pump system ( LAN096 ) that is only 4 months old was working great in all ways until suddenly it quit heating. I am sure it happened quickly because I was nearby when very warm air changed to cool ( unheated ) and hasn't heated since. When I shut it down and restart it the indoor fan runs right away, which is not normal and the outdoor unit will run for a minute or so then shut down and stay off. The indoor fan will continue to spin as though it is set in a 'fan


... LG Air Conditioners

Fan speed on cool setting only works on low


If it's in Energy Saving mode, that may be normal.\015\012\015\012Geno ... Comfort-Aire EKTC12-150J Air Conditioner

Fan setting only works


Bad thermostat or open thermostat wire can cause this condition ... Ruud UAMB Air Conditioner

Rudd furnace I have a RUDD furnace model UGPJ-07-NAMGR. It had stopped working, so I replaced the thermostat but it is not the thermostat. When I hold the furnace reset button, the furnace will fire according to the setting on thermostat(heat or fan). As soon as I let go of the reset button, the heater stops working. It does not matter what I do to the thernostat, the heater will not fire. I crossed the red and white wire but nothing happens. The heater is supposed to fire when I cross wire, ri


You have a safety limit switch that is either bad or needs to be manually reset. Some have little buttons between the two wires going to the switch that you can push to reset. If not they are automatic switchs then one is bad. You have to do an oh ... Ruud UBHC Air Conditioner