Fan relay wireing

\015 Can i please get a wireing diagram for my intertherm PRA-042k blower fan(relay) thanks\015

Answers :

It is a peanut style relay with 5 wires. Two which are for a coil, and 1 normally open and one normally closed and one hot. The relay on that model does tell you that.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Old system has a 6006 aquastat wiring through line voltage of fan relay on board. New Trane a/h has variable speed motor no line voltage fan relay question: How to wire 6006 aquastat to new low voltage board i do have a 8222d relay for t-t from boiler that is wired to line voltage of fan relay. Thanks in advance Chris


Hello The easy way to bring the blower on for heating is if the thermostat has an ELECTRIC heat function or selector switch.That will bring on FAN during a call for heat.The aquastat won't be used. ... Air Conditioners

I have a Intertherm model FEHB-015HA . The fan runs all the time. It has a relay box on it but I cannt read the #'s off of it. I have replaced the sequencers, The fan relay onthe relay box and the little switch that you turn fron auto to off to on . I need a wiring diadram for the furnace and the relay box . i think someone has messed with the wires.


Check out these Installation Instructions...........wiring diagrams on the last page. \015\012\015\012I hope you find this to be ... Intertherm Air Conditioners

Blower fan stays running. Fan relay attached to small circuit board (coil tabs [timer?]). Capacitor on small circuit board had ''fallen out'' of ic board. Tried to get replacement board, and was sold just a standard relay - told that relay alone replaced the previous relay -and- circuit board configuration (?). Problem still exists (no change). Also changed thermostat just to eliminate as a possible cause, but seems like problem must be in the fan relay area. Question about the wires attache


... Carrier Air Conditioners

I'm hooking up the wires to a gas furnace, i have the 4 wires from the thermostat , two wires to the condensing unit of the a/c, two wires for the fan relay ,a wire from the gas valve, and a wire from the limit switch. they go on a board attached to the transformer. The screws on the board are marked r,c, w, g, and y. what wires go to which screws to make the furance run correctly


Hi,\015\012\015\012\015\012R -This terminal is the power\015\012for the thermostat. This comes from the transformer\015\012\015\012C- Common side of\015\012transformer\015\012W - This i ... Air Conditioners

I have a Fedders electric furnace and a service technician connected a red wire "post purge fan relay". Now fan run all time in heat mode. What is this wire for?


... Air Conditioners

I have a Fedders electric furnace and a service technician connected a red wire "post purge fan relay". Now fan run all time in heat mode. What is this wire for?


... Air Conditioners

Have two Broan exhaust fans that I want to wire to a programable hvac themostat.I'm told that I need a relay and not sure how they are wired. The fans draw 1.23 amps each and looks like they have


Are you sure that your not looking at motor capacitor attached to each motor??? To use programable stat you would have to find line voltage stat with rating to handle fan amp . other option is to use low voltage stat and transformer and fan switchin ... Air Conditioners

I have installed a UPM model THM101B thermostat on my Intertherm model E3EB-015H electric furnace. I wanted the feature of turning the blower "ON" without the heating elements. I picked up the green 12v for the fan relay. Once the power is restored the furnace comes on even though the temp setting is low and the only way I can turn the furnace off is by disconnecting the green fan relay wire? The jumper has been properly set in the new thermostat for electric furnace operation.Right now I feel t


... Intertherm Air Conditioners

I have a Coleman Presidential 7670 furnace in a mobile home. customer said it came on a couple of times by itself. I ran new wire, fan won,t shut off. Replaced fan switch, fan still won't shut off. Replaced t-stat, same problem. This is an older unit and has no board it has a fan switch a low limit switch, i,m guessing the other is a high limit and a fan relay. I have no schematic and am very frustrated can anyone help me please. Thanks. Brian from california


Brian, it sounds as if possibly the fan relay is stuck however, if the fan will not shut off I would suggest the following, Follow the wires from the fan to the relay on the relay disconnect the fan wire there and see if the fan shuts down if so t ... Air Conditioners

When I switch the T-stat to (fan on) the blower won't come on unless I move the Fan limit up close to the 100 degree mark and then I move that limit back down close to 130-135 degree and after approx. 10 seconds blower shuts off. I'm not sure where that fan limit is supposed to be set at, it was originally set around 130-135. It's a 2 wire limit and the range is 100-140. I know the stat is sending signal, I get 24v on green term. at fan center relay. Thanks, Dave


To help you we need more info. What thermostat and what furnace or air handler. There are two circuits involved. One is the green wire or g terminal that switches the fan relay into high speed for ac. The other is the w white that actuates the fan cy ... Air Conditioners

A Nordyne air handler, model B3BV-030K, with 4 wire thermostat. Thermostat and AC works fine in "cool". Switch it to "heat" and nothing happens.No fan, no heat.(I have built in heat strips -resistors). I jumpered (on the nordyne circuit board-input from thermostat) from R to W. (24 volts from R to W, which should start the heater. Nothing. No relay "click" like when AC comes on. If i jumper R to Y, AC comes on ok. Does this sound like a relay gone bad on the circuit board? Or what? If relay bad,


Do you get heat when you jumper R, G & W? ... Ruud Central System Air Conditioner

I have an intertherm center heater. I just purchsed the new house and it finally became summer. I tried to turn the fan on only as I am used to in other homes. However, the fan does not come on. I looked in the inside of the heater and see that a gray wire is not hooked up, which may be the fan relay??? Any help appreciated.


Site for wiring diagram;..http://www.xpedio.carrier.com/ide/groups/public/documents/techlit/ag-maba-03.pdf ... Intertherm Air Conditioners

I have a Rudd 240V air cond and changed out the condensor fan motor that had 3 wires brn, blk and org. the new one has 5 wires,brn,blk,org,blu,yel. which wires do I connect to relay and single capacitor.


If you will look on the side of the new motor is should show you. But the black and brown will go in the same place as your old one. Generally, the yellow will replace the orange. Black is hi speed and will be connected to one side of the "re ... Ruud UBHC Air Conditioner

Installed goodman air handler, system has hot water coil in duct for heat, how should i wier the 6006, or 4006 control to turn the fan on, on the air handler? if the limit switch turns the fan on for heat, isn't it going to send 24 volts back up the green wire to the t-stat? old air handler ( york) had a fan center relay.


\015\012\011\011\011\011\015\012\011\011\011\015\012\011\011\011\015\012\015\012\011\011\011\015\012\011\011\015\012\015\012\011\011\015\012\011\011\015\012You abso ... Goodman Air Conditioners

I have a dometic heat pump a/c basement park model unit. The fan is not working. The compressor runs, but no air inside or out. I have power into the run cap. but not on the brown wire to the fan from the run cap. I also have no power to the fan high or low off of the relay board. Where do I go next to isolate?


... Dometic Air Conditioners

Fan relay wireing


It is a peanut style relay with 5 wires. Two which are for a coil, and 1 normally open and one normally closed and one hot. The relay on that model does tell you that. ... Airtemp B6D30E7A Air Conditioner

Changing from Intertherm thermostat to a Honeywell Thermostat. My sequence relay wont work. the wire is on the A/C fan blower side. How do you get the relay to work?


... Intertherm Air Conditioners

T-stat problem I am workig on a 92 intertherm.Trying to install new stat to control heat and cooling. top of control panel only has C Y W R were does the fan wire (green) connect ? the only #s I have togo by are 901698-2wire relay box


HEY, the only logical explanation is, that unit didn't have fan only. ... Intertherm Air Conditioners

I need to klnow how to wire a airhandler and its compoments like a ruud airhanlder containg a seqeuncer,transformer, fan relay and tstat and blower motor. basciaclly what wires go where


... Ruud UAMB024 Air Conditioner

Air Handler: I have two 24V supply lines one from the transformer the other, I think from the condenser fan. Both wires are connected to a relay which operates the indoor blower. When the 240V power supply is turned on I get a buzzing sound from the relay. Can anyone help me with this problem. Mickey


You have 24 volts from the indoor thermo to the transformer in the air handler then 24volts from air handler to the contactor when this is energized it goes to 240 volts to run the compressor and outdoor fan. Sounds like the contactor is not enegizi ... Air Conditioners

I need the wiring diagram for my Intertherm central electric furnace, model number FEH-015 HA with central a/c. I am having relay problems and thermostat wiring problems after my fan motor had to be replaced. Thanks!


... Air Conditioners

I have a white rodgers thermostat that controls both heating and cooling functions... there is a manual switch for the main circulating fan which does not seem to be activating the fan, is this a thermostat issue, or a relay or other issue in the electrical wiring for the furnace/thermostat?


IS THIS THE SAME TYPE OF THERMOSTAT THAT WAS ON THE UNIT IN THE FIRST PLACE AND IF NOT THEN GET THAT ONE AND REPLACE THE OTHER ONE ... Air Conditioners

Coleman manual for fan relay wiring on model 7336a815


... Air Conditioners

'i have Clare Brothers Mod AG100 UH-A furnace ser103800 . I need wireing diagram , It has Honywell AT 20B1015 relay was run without Thermostat Fan does not run ans furnace shuts down incl8uding pi


... Air Conditioners

Had a Goodman heating unit installed in Oct. 2009. Recently tried to turn ac on .but no action. Installer returned and hooked up some wiring which got fan working but no cold air. The outside compressor worked only when I manually closed the relay. What cculd be the problem.?


It sounds like the outside condenser wires are still not hooked up correctly or there is a problem with the 24v electrical inside the unit. Describing what you have, I'm just banking on the connections. Now, if you have a heat pump system, there will ... GE AJCQ08ACB Air Conditioner