Having problems with your Air Conditioners ?

Heat mode on trouble

\015 A.c works good in cool mode.when change to heat mode system geting off. compressor over heating.solinoid why \302\240valve makes trouble in some units. can you expline its works in details.\015

Answers :

Possibly changeover valve not functioning correctly causing high head pressure and  safety to switch off in protection mode.not the ideal DIY repair.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Heat mode on trouble


Possibly changeover valve not functioning correctly causing high head pressure and  safety to switch off in protection mode.not the ideal DIY repair. ... Air Conditioners

No Heat Unit works fine in cooling, auto and dehumidification modes but when you select the heating option, the defrost light turns on with no air coming through. Have cleaned the dust filter and outside unit is free of any blockages. Trouble shooting guide in instruction manual does not address this problem. Any help would be appreciated.


In heating mode, the outdoor unit should run to build up pressure and hence heat. To facilitate this, the indoor unit fanmotor will only come on once a sufficient pressure is reached. If you are a bit low on refrigerant, this may not happen. Or it co ... Air Conditioners

Baxi Bahama 100 SIT controlsI have checked most items cannot get pump to fire up in central heating mode followed trouble shooting steps and leads me to pressure switch fault which works properly. I would like any ideas on this getting frustrated now


... Air Conditioners

When in heat mode heater keeps turning on and off has trouble to keep running cuts in and out for about one minute then only runs for short time and of sometimes trips the switch in meter box ( small green light on unit turns on not the on light the one on the other side)


The cutting in and out is indicating that it has reached its internal thermal limits .. its too hot inside .. that trips a thermal breaker .. the breaker resets when the unit cools ... the problem is almost always caused by not enough air flow ... th ... LG LS-K2430HL Heat Cool Mini Split Air Conditioner

Carrier 585C day/night :red/white thermostat wires connected to bypass thermostat not ignition. no current going to ign T1 T2 low volt input wires...no fan except in cool mode or manual....unit will not provide heat. Trouble shooting sequence ??


... Air Conditioners

We have a slim heater/ air conditioner on our wall. It's been in airconditioning mode for the summer. I'm having trouble 1 . it shuts off within seconds of turning it on. I've tried to cancle the timer. Lost the manual. 2. I cant get the fan to blow warm air, the blade to even rotate but it works with cold air!!!ouff... ....the remote is on heat ....temp says 74 on both wall and remote mdl # LMN120HE suggestions?!? We're cold.....


This is a tippical heatpump problem. get the revers valve unstuck. energise the coil to the valve, on and off. make sure the power is on to the coil.(HEATING MODE AT FULL TEMP). if you are not electrical minded leave it be. get someone with electrica ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

Friedrich YM18 230 volt heat pump. The unit has heated and cooled well for about 5 years. Just started heating mode recently and the unit no longer heats. Fan runs OK. Was able to get the heat strip to run for a few minutes (smelled the dust accumulated over the summer burning off). Now, no heating whatsoever. When in the "Money Saver" mode, nothing happens. Fan will not come on and unit will not heat. With "Money Saver" mode off, the fan runs.


... Friedrich Air Conditioners

My outdoor heat will not operate. It is a Carrier 38YRA042330, with a Carrier Thermidistat thermostat and a Carrier Air Handler 40FFKB005300. I have an H5 error code on the thermostat will I put it in Heat mode and raise the setting to call for heating. I changed the air filter on the air handler when I realized the heat pump was not operating. The air filter was pretty dirty. The system will operate in aux/emerg heat mode, with the fan in Auto or On mode, and will maintain the thermostat


You need to go oside and look for a red reset button on the unit. you tripped the high ressure switch when you let your filter get that dirty. go check on this and when your done if it still is not working then ask me more. ... Carrier Air Conditioners

Lg Neo plasma inverter split model s18ahn isn't heating or cooling properly. When in heating mode air con will go into defrost/preheat mode for 5 minutes and then air con will blow out air for 5 seconds and then go back into defrost/preheat mode. When in cooling mode indoor fan will pump out air but will not get cold. In both heating and cooling modes the outdoor unit will not start up and the outdoor fan will not spin. I have just replaced the main pcb board and that hasnt made a difference. Bo


... Air Conditioners

Amana PTAC Unit is not producing heat. Fan works fine. can not locate manual reset for heat although a label on the unit says there is one. I have an Amana pth153b35ae ptac unit that the heat will not come on. The compressor will run in the cooling mode but not in heat mode. I verified the switching valve is working and the capacitor seems to be fine as the compressor will run in cooling mode. The thermostats seem to be functional because relays can be heard clearly when changing temperature se


I know this is late but I had to add a solution to this problem since I had the exact same problem and was able to solve it. The probelm is not your control board. On these units, the heat pump compressor will not kick in unless the temperature you ... Amana PTH123B25AJ Heat Pump Air Conditioner

Amana #PTC153b50AJ ser 0410686783 Customer heard a pop in unit and it went off. Breaker was tripped. Reset breaker and unit runs in a/c mode but does not heat in heat mode. This is not a heat pump but electric heat strips. Unit says there is a manual reset for the heat but we have not located the reset. We turned power off to the unit to reset fault etc and still no heat. The flashing light just blinks once every 4-5 sec. Could use some help in diagnosis Thanks DK


... Amana PTC153B50AJ Electric Heat Air Conditioner

I have a aircond / heat pump unit. When in the heating mode it run for about10-15 minutes and you hear a small bang and here a rush of pressure in the aircond lines and the the unit seem to be running in the arircond mode insted the heat moded. Thanks


Hello,Your heat pump is in DEFROST mode and this is normal(only during a call for heat).When in defrost mode the supply air temp should still be warm as 1st stage electric heat strip comes on during the cycle.If the unit did not defrost every once in ... Coleman Air Conditioners

Amana PTH153B35AK This unit is less than 30 days old, heats fine cools fine, but when i have it in heat mode,set @ 70 or so, as soon as the room heats up, the unit will cycle into a/c mode and blow super cold air for about 5 minutes than return to heating. Sometimes it will reach the desired temp. and turn off like it is supposed to do, but for the most part it just cycles back and forth from hot to cold...Amana has the worse help/service i have ever seen, i was on the phone for an hour,everybod


This often happens if the unit is oversized or to close to a wall or object. ... Amana PTC153B35AK Air Conditioner

Heating problem hello! My air conditioner stopped to heat. (there is a around 8 degrees C, outside and 16 degrees inside). It worked just fine, and now, when I switched to heating mode, there was nothing. the defrost LED ond the inside unit is switched on, but air is not comming from the unit. Cooling mode works fine. If you could please help me finding the solution for my problem. Thanks in advance. RAdan GE AIR CONDITIONER SPLIT SYSTEM WON'T WORK ON HEAT CYCLE Seems to work ok doing eve


Hi Radan, Did you get this problem solved? We have an Electrolux Kelvinator Split System and ours is doing exactly the same thing. I am struggling to find a solulution. Would be great if you can offer any advice.\015\012\015\012Thanks Nic ... Air Conditioners

My bryant heat pump installed in 2008 makes a loud squealing / moaning sound during heat mode,it is a 3 ton,i keep it 66 degrees tring to save money my bill was still 196.00,it goes in to emergency heat mode on its own,this uses the most power,what causes the load noise,during operation,not when it starts,but during the heating prosess,the old one did not do this it was a cumberland brand,do not know maker,


Sounds like a normal defrost cycle. Watch it next time it does it. The outside fan stops, there will be a 'swishing sound'. That is the reversing valve changing over. Then you may see some water vapor rising up fromt he condenser, the emergency hea ... Air Conditioners

Ruud 300 thermostat in heat pump mode and I don't have the manual to get it out of that mode. It was working fine then switched to this mode. No more cold air. I live in Florida so I don't have a heat pump installed. I remember I had to switch to Electric mode but its a buncha codes. How do I switch it? Thanks


Hi,\015\012Here is the complete manual for your thermostat...\015\012\015\012Click here\015\012\015\012 ... Air Conditioners

I HAVE AN AMERICAN STANDARD HEAT PUMP/AIR CONDITIONER UNIT OUTSIDE MY MOBILE HOME A FEW DAYS AGO A UNKNOWN SMELL COMES THRU ALL VENTS IN AIR CONDITIONER MODE ONLY. WHEN HEAT IS ON THERE IS NO SMELL UNTIL IT GOES IN DEFROST MODE AND THEN IT SMELLS ONLY A FEW SECONDS , WHEN HEAT COMES THRU IT STOPS. I NEVER HEARD OF THIS. THANK YOU


This is a condition called Dirty Socks Syndrome air cleaners and dehumidify usually fix the problem also adding a uv light to the duct can remedy the problem the light is probally the cheapest solution ... LG LS-K1830CL Cool Mini Split Air Conditioner

Hi, I have a wall mount midea split a/c model- MSG-36HR that will only heat. when put in cool mode it only blow's room temp air and the outdoor unit won't run. On heat mode it works normally. I have cycled power a couple of times, changed modes on the remote numerous times and just in case, changed the batteries in the remote. The unit is about 3 yrs old. Do you have any pointers. Cheers Tom


Most heat pumps are 'fail-safe to heat'. That is: the normal position of the valve which reverses the function is in the position which provides heat. The reversing valve must be powered to switch to the cooling position.Although the ... Midea Air Conditioners

Heating problem hello! My air conditioner stopped to heat. (there is a around 8 degrees C, outside and 16 degrees inside). It worked just fine, and now, when I switched to heating mode, there was nothing. the defrost LED ond the inside unit is switched on, but air is not comming from the unit. Cooling mode works fine. If you could please help me finding the solution for my problem. Thanks in advance. RAdan


The LG>LW5200ER AC is not listed as a heat providing unit. Click on link and this will give you the spec's\015\012\015\012 \015\012\015\012 ... LG LW5200ER Air Conditioner

Lsn122he/lsu122he runs fine in cool mode but in heat mode defrost symbol comes on and stays on = no heat operation. worked fine this past winter till end of season. note ac mode still works fine.


... LG Air Conditioners

Having trouble with heat pump.


It sounds like there is a problem with the blower....either the motor itself, the capacitor, a wiring problem or a control problem. If there is a warranty on the unit, have a tech check it out for you. \015\012\015\012Let us know if this ... Air Conditioners

I have a Ruud Heat Pump system. The outside unit makes a humming sound in either heat or cooling modes. The fan won't come on. In cooling mode, the compressor starts up, but them shuts off after about a minute.


Sounds like your condencer fan motor is stuck. Can you take a long rod and when the power is off to the outside unit, spin the fan blade? Maybe it will be enough to get it working again. ... Air Conditioners

Can not get Goodman 3-ton heat pump out of heat mode and into cooling mode


The reversing valve may be stuck. It allows the unit to switch between heating and cooling. You may be able to give it a tap but only on one of the ends, not the sides, and only lightly. You could also unplug the reversing valve from the circuit boar ... Goodman CLQ36AR49 Air Conditioner

Coolstar MSM3-09HRN2 I have 4 of these units in my Greek home The installation manual is in English but the user one is Greek ?? Having problems when we use for heating in winter, where they go into DEFROST MODE on start up, 2 of the 4 then go on to heat the other 2 stay in this mode They are all just over a year old. Any help greatly appreciated Laurence H Walton


... Air Conditioners

Trying to hook up haier heat pump as cond. only. when in ac mode system is in heat mode. either iam missing something, not right digrams


Hello RRIKE The reversing valve is not energized.At the thermostat check the "O" termnal is used.It switches the valve over to cooling during a demand. ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy