Having problems with your Air Conditioners ?

Aircondition not working

\015 My ac module number is afs60fx it was working fine untill i just see it stop and the letter EI flashing on the screen and it wount turn on or off with or without the remote.can you help me fine the problem.\015

Answers :

E1 indicates  Filter needs replacing/Cleaning , this code flashes after 720 hours of operation time.

\015\012\015\012

Disconnect the power plug

\015\012\015\012

 

\015\012\015\012

Clean or replace filter

\015\012\015\012

 

\015\012\015\012

HOLD DOWN (dont let go) Of  the ON/OFF button and plug the unit back up and continue to hold the ON/OFF button until you hear a beep

\015\012\015\012

 

\015\012\015\012

After the beep unplug your A/C

\015\012\015\012

 

\015\012\015\012

Then plug it back up to and turn it on for normal operation

\015\012\015\012

 

\015\012\015\012

IF THIS FAILS TO REMOVE THE CODE

\015\012\015\012

 

\015\012\015\012

UNPLUG A/C  THEN HOLD DOWN THE MODE BUTTON AND PLUG IT UP STILL HOLDING THE MODE BUTTON UNTIL YOU HEAR A BEEP.

\015\012\015\012

 

\015\012\015\012

UNPLUG UNIT  AND THEN PLUG IT BACK UP AND ONE OF THESE 2 STEPS WILL FIX YOUR PROBLEM   UNLESS THERE IS A MAJOR PROBLEM IN THE CONTROL BOARDS

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Hello, my airconditioning does not work constantly. The pump does noet get a signal all the time. The cooling-fluid is checked and is OK, the pump works OK, the low- and high pressure swithces(valves) have been checked and are OK. One time, when i drive the car the airconditiong starts after ± 10 minutes, the other time is does not work at all, and another time it works for 10 minutes, stops working for a few minutes and starts working again. And so on. My mechanic says he thinks it must be a ba


Sounds like the A/C relay is bad. They are located under the hood in a fuse block. What type of car, make and model along with year. ... Air Conditioners

I have amana PTC123B35AE unit. aircondition work fan works only heat does not work


... Amana PTC123B35AE Air Conditioner

2007 Ford Transit airconditioning wont work - the light comes on, but there appears to be no aircon coming through the vents. Fans work ok, dont hear any change in the motor tone while trying to operate aircon. Spoken to previous owner, and he had never used the aircon at all.


MAY NEED RE GASING ... Air Conditioners

My coleman Mach Rv air conditioner with built in heat strip keeps tripping it's internal circuit breaker when running for any length of time. Just replaced heat strip with new one experienced same issue. I ended up with the fan continuing to run but only cold air comes out of the vents! When I removed the old unit and reset the circuit breaker it too worked again. Have no idea what is causing this to happen. The airconditing part of unit works just fine??? HELP! Ron


There should be an overload protection device in series with the low voltage wiring(t-stat wiring) Is it resting on the heat strip or too close to it? It is a saftey device to shut off the heat strips if the fan quits or a fire in the heat strip sec ... Coleman Mach III Air Conditioner

Alpine airconditioner model kfr60gw We have had the electricity supply to our airconditioning system switched off for a couple of months.We turned it back on again and cannot get the system to work. The remote control is working but the system is not responding. How can we get it to start up again?


... Air Conditioners

OUr air conditioning system works well until the circuit breaker trips. We added another large return vent in the hall to try to get more air circulating and that didn't work. We just replaced the outdoor airconditioning unit and the circuit trips again. The electrician says the wattage is fine. Any ideas what could be the problem. Everyone is baffled because the house is only 5 years old.


Current (amps) is voltage (volts) divided by resistance (ohms) or I=v/r. Breakers "trip" when there is too much current flowing through them. ... Air Conditioners

Need the manual. The airconditioning works great. But the heater isn't working at all. There's air coming in but it's not hot at all. i can't figure out what's the problem and have no idea what to do to rectify it.


Sounds like ur reversing vavle is faulty.it happens to alot of a/c units ... Air Conditioners

The remote works but the aircondition dont start. the unit start working alone in the midle of the night. please help me.thank you.


Make sure its not on a timer ... Air Conditioners

Aircondition I have a air conditioner problems, the unite inside the house is working I can hear it and feels the air coming out of the vent but it's not getting cool air, the unite outside all I hear is click once and about 2 to 3 mint. click again. I have the other air condition next to and it click and then seem to locked and worked. help..


You will need an OHM meter to check the relay and compressor. Make sure all power is off. The most common types of compressor winding failures are open, grounded, or shorted. You have to know how to read a meter. If you don't find someone who can. Or ... Ruud UAKA030 Air Conditioner

When the airconditioner is on, the big unit (blower) outside does not work> When we finally got it to work, the air coming out is not cold, it's just like a blower, it's like the air it is blowing is from an electric fun. We have ducted airconditioning, Fujitsu ART series and it's only 2 years old.


Check the compressor is working with exact amps. If not short of gas or no gas. Check thermostat setting 23 degree with cool mode. ... Fujitsu Air Conditioners

I need a data sheet for this aircondition to know if it works at -15/20 C


Check given link for manual\012http://www.manualbus.com/air-conditioning-manuals/air-conditioning-panasonic-cu ... Panasonic Air Conditioners

Aircondition not working


E1 indicates  Filter needs replacing/Cleaning , this code flashes after 720 hours of operation time.\015\012\015\012Disconnect the power plug\015\012\015\012 \015\012\015\012Clean or replace filter\015\012\015\01 ... Sharp AFS60FX Air Conditioner

Airconditioning not working - Honeywell Air Conditioners


Problem fixed ... Honeywell Air Conditioners

My aircondition blower fan not work - Air Conditioners


It is either the capacitor or the start windings on the motor. Since a capacitor is about $5 and a motor is $100 I would try the capacitor first. Be careful, capacitors hold voltage so even if the electricity is turned off you could still get shocked ... Air Conditioners

LG Reverse cycle ducted (in ceiling) airconditioning works normally on heating and coooling and then cuts out after 2 days and shows error code 61.This is in 3rd floor apartment. The system can be reset by switching power off at meter box and switching on again but only runs for approx 1 - 2 days and gives the error code 61 again. The motor is in a plant room in the apartment building.


Error code CH61 - CONDENSER PIPE HIGH PRESSURE. This can be due to overcharging of the system or the condenser clogged with dust or an obstruction, or condenser fanmotor not working. Hope this helps. ... LG Art Cool LA121CNP wall/window Air Conditioner

I need help finding out whats wrong with my centrex ctar35gw/cx splitsystem airconditioning system i have three of these and when i turn them on the screen comes up with E4 and wont work


Hi, the code E-4 = compressor failure do to one of its overloads. High pressure in system due to maybe a dirty coil, you can try and wash, compressors are going off on these overloads do to lack of service. Try cleaning condenser coils. It makes sinc ... Air Conditioners

We have a slim heater/ air conditioner on our wall. It's been in airconditioning mode for the summer. I'm having trouble 1 . it shuts off within seconds of turning it on. I've tried to cancle the timer. Lost the manual. 2. I cant get the fan to blow warm air, the blade to even rotate but it works with cold air!!!ouff... ....the remote is on heat ....temp says 74 on both wall and remote mdl # LMN120HE suggestions?!? We're cold.....


This is a tippical heatpump problem. get the revers valve unstuck. energise the coil to the valve, on and off. make sure the power is on to the coil.(HEATING MODE AT FULL TEMP). if you are not electrical minded leave it be. get someone with electrica ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

I have a 2000 (year) 30' Four Winds Hurricane Class A Motorhome and the airconditioning is not working in the front or back unit. I took it to an RV repair shop and they said they can re-charge the driver's unit, but can't re-charge the back unit in the living quarters, due to it being a model with a different freon set up. They said I would have to purchase a new model at $2000. What's the deal? Can it be re-charged? The motorhome is only 10 years old.


If someone replaced the rear unit with an a/c older than 1995 it is a possibility but I think they are feeding you some bull.Are you in Indiana?I found a link to Four Winds home website which is in Indiana.I would call them to find out.If you are in ... Air Conditioners

I have a samsung AQV12 fan airconditioning unit. The problem is it will not work, the indoor unit has two green lights flashing and one red light flashing.


Hi! Please try this. Remove the battery from the remote then insert it again. Press the up and down temp button at the same time and it will give you code. Please try to click on the link for it will guide you. Hope this helps and have a good one! ... Air Conditioners

Airconditioning not working. help - Carrier Air Conditioners


Call the repair man. ... Carrier Air Conditioners

Honeywell 7512A. Working fine. Turned off power yesterday notice no display so once power was restored I changed to new batteries. There should of been a display due to the batteries. New batteries were checked fully charged. Breakers were all reset. Batteries are in properly. Now I have no display. Polarity is correct. Wiring configurations is White to white. Orange to Yellow terminal. Green to green. Black to red terminal. Red to RC terminal. I have airconditioning and heating.


... Honeywell Air Conditioners

On my 1999 camper trailer when I turn on the dc powered lights while the airconditioning is running the compressor will kick off. If you wait 3 minutes it will come back on and continue to work fine until you turn the light back on.


Welcome to FixYa\015\012\015\012Not enough cooling complaints are due to air flow issues, and not lack of “Freon.RV air conditioner- come from the factory- are hermetically sealed.The first basic area is the air ... Dometic Rooftop RV Air Conditioner

The breakers for AirConditioning keep throwing the outside unit does not come on - insiide by " the Heat or Cool buttons it sounds like it is working - I put 2 Brand new fuses in the electric box outside our house but nothing has changed


You need to check the three wires on the compressor, hopefully one or two are burnt. If the wires are good then the compressor is shorted, way to test. disconnect wire and use a multimeter, ohms setting, touch one of the copper lines and then where ... Coleman Air Conditioners

Hi any chance you could send me a wiring diagram for a carrier ducted air conditioner model number 38QRT060. its a very old air conditioner and the diagram on the unit has faded.it looks like the honeywell controller is faulty and i was hoping i could bypass it to get it running.i work for an airconditioning company as an electrician in muswellbrook nsw aust.thank you


... Air Conditioners

I have a Tempstar 9000 airconditioning unit and while I was weed wacking I accidently cut a wire to the unit. I replaced the wire but now the unit wont turn on and also my furnace blower wont work even in the "on" position. I have a energy saver unit attched to the a/c unit as well. One wire connects to the a/c unit and the other to the energy saver. If I push the connector on the unit with the panel off the unit will run. Cansomeone tell me how to connect those four wires?


Hello TLOEKS You blew the transformer FUSE inside the blower unit! It should be a 5amp blade fuse like the one that goes in a car.It is located at the curcit board at the blower compartment.Replace that to restore low voltage power and every thing wi ... Air Conditioners