Having problems with your Air Conditioners ?

Intertherm to Honeywell thermostat

\015 I have an intertherm central heat/air, one day it just stopped working all together.\302\240 Thermostat wire going into outside unit was showing wire through plastic. Cut and connected back together but nothing. Am now replacing the thermostat from Intertherm to Honeywell. Question is Intertherm has Blue wire that Honeywell does not have. Also Intertherm does not have anything in the RC connector. Should I use the jumper or not on the Honeywell ?? Thanks for your help\015

Answers :

Typically if you have a yellow wire in the "y" terminal blue is used as common or "c". As far as your jumper from rc to rh, that will depend upon what type of heat you have. If all of your heat and cooling come from your packaged unit outside, yes you will need the jumper. If this does not work maybe you have a bad breaker or transfomer.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Intertherm to Honeywell thermostat


Typically if you have a yellow wire in the "y" terminal blue is used as common or "c". As far as your jumper from rc to rh, that will depend upon what type of heat you have. If all of your heat and cooling come from your packaged unit outside, yes yo ... Intertherm P3RA-048K Air Conditioner

Changing from Intertherm thermostat to a Honeywell Thermostat. My sequence relay wont work. the wire is on the A/C fan blower side. How do you get the relay to work?


... Intertherm Air Conditioners

I have an intertherm electric furnace FEH-A020, with multispeed blower installed when A/C added. My problem is blower operation. at the end of the cooling season with fan set to auto operation the fan ran continuously. Now that I've turned the unit back on for heat the blower will only function with the switch in the on position (continuous operation), in auto mode the heating elements come on with the signal from the thermostat (Honeywell CT3400), but the fan does not. I checked the fan relay p


The model of T-stat you gave comes up as a discontinued model on Honeywell's web site, but it looks to be a manual stat that type of stat would have to be wired with a summer winter switch with electric heat, allowing it to turn on the fan with a cal ... Intertherm P3RA-048K Air Conditioner

I have a Intertherm P3rA-042K that runs the ac at the same time as the heat strips. I have a Honeywell RTH3100c I have the red wire at R the Yellow at Y the Green at G and the W2 at aux. I had a jumper between Aux and E like the manual said but it makes no difference. Also for some reason it was hooked up before with a blue wire joined with the red at the unit and the blue going to B at the thermostat. I removed the blue as i saw no use for it and it still doing the same thing. The unit froze up


Red, green, and yellow should all be from AC unit. What other wires do you have there, and are they separate from red , green, yellow? ... Intertherm P3RA-042K Air Conditioner

Honeywell thermostat is out. Tried replacing battery but still out. Trying to replace with temporary Honeywell thermostat but can not figure out wiring. I have a white, red, and blue wire. The original thermostat is a Honeywell Vision pro IAQ.


You will need a voltmeter. I believe 2 of the wires (probably the white and red are the power; either 12 or 24 volts) and the blue is the switch leg.\015\012\015\012If you don't have a voltmeter, you can twist the blue and the white toget ... Ruud UAMB Air Conditioner

Intertherm Thermostat I bought a programable thermostat to replace the intertherm. I am confused about the wires. The intertherm has an x wire, it is black but there is no x wire option with the new thermostat which is a Hunter 44860.


The wire that is on the x- terminal  on the old tstat will be c-terminal on the new tstat. ... Air Conditioners

Borg warner Is the old round York Borg/Warner thermostat incompatable with a Honeywell? I just replaced my old round mercy switch thermostat with a Honeywell RTHL111 thermostat. The air conditioner service man says it is hooked up right, but the fan on the unit will not run on auto (it must be in the on position on the thermostat [thus the fan runs all the time]). He also replaced a relay switch inside the unit. We are using air conditioning only on this unit. Red to R (strapped to Rc), gree


... Air Conditioners

Im changing an old honeywell thermostat with a new honeywell thermostat. the old on has wires 4 wires connected to 4 screws C,R,G,W but the new thermostat has a place where the wires go which are Rh,Rc,W,Y,G. will i be able to connect the new thermostat?


Yes, I believe that you will be fine. If the original wiring is correct then I have listed the basic wiring below. As always read the directions and make sure the wiring matches your system.Red wire = Rh (24v power, should have an exsi ... Honeywell Air Conditioners

I am changing an old circular Honeywell AC thermostat to a new Honeywell VisionPro TH8321U thermostat. There are two wires coming from the old thermostat and I want to know which terminals do I attach the wires to on the new thermostat?


Ac only?r and y ... Honeywell Air Conditioners

I have an American Standard Freedom-80 Two stage furnace/AC. After replacing my old Honeywell with a new Honeywell RTH2310 thermostat (which the guy from A-1 Heating & A/C assured me was compatible with my system) the A/C won't kick on. The thermostat is registering the ambient temp & when I turn the thermostat fan switch to ''on'', the fan turns on, but not with cold air. I have not even tried the heat because it was 89 degrees F inside already, but would expect the same issue. The metal doo


If your system worked prior to installing the new thermostat, then you may have to change how your thermostat is wired in the rear, as I encountered the exact same problem in that regard. Beyond that, if you have a blinking light, chances are it may ... Air Conditioners

I have a carrier air/heating unit with pump. It has 8 wires. Brown,blue, white, yellow, green, black, orange,and red. I'm trying to install honeywell thermostat. The wires from my unit are suppose to go into these honeywell (RTH3100C) thermostat slots. hONEYWELL WIRE SLOTS E Aux Y G O L R B C The only thing i have to go on is the wire colors from my wall which were not labeled or coded in any way. I am not sure about the model# of our unit because it is so old that the model# has faded away the


Turn the power off to the air handler. Open the control cover. Write down what color wires go together at the wiring terminal. All 8 wires are probably not used.\015\012Post the findings here.\015\012In most cases,\015\012E= brown-e ... Carrier Air Conditioners

Got a honeywell t8400c thermostat i'm trying to replace with a honeywell rth3100 honeywell thermostat but only have yellow green red and white wire on the old and don't know where to put the wires on the new


R--- rc or rh y--yellow g---green w--white red is power yellow is cool g--fan white is heat ... Honeywell Air Conditioners

I'm installing a Honeywell RTH7600B programmable thermostat and replacing a Honeywell T87F2873. The new one calls for a Red, Green, White, and Yellow wire, while I only have a Red, Green White and Blue. How should I connect the new thermostat?


Every thing the same except take your blue wire and replace the yellow for it. So when you hook it to t-stat goes like thisRed to R White to WGreen to GBlue to Y ... Air Conditioners

Bestech digital thermostat - Honeywell Basic Digital Heat & Cool Thermostat. Non Programable. - HONEYWELL


... Honeywell Basic Digital Heat & Cool Thermostat. Non Programable. - HONEYWELL

Honeywell t87n thermostat for furnace - Honeywell T87N1000 Round Thermostat


... Honeywell T87N1000 Round Thermostat

I'm tryingt to install RTH2410 honeywell thermostat for a central air/gas heat system. I accidentally discarded the old thermostat, because I thought the honeywell would be easier to install, but nothing comes on. It has B, R, W, Y, G wires Any tips


\015\012Call 1-800-468-1502 for wiring assistance.\015\012You probably have the wrong wire on the R terminal. Make sure that the wire on the thermostat R is the same wire that is on the furnace R terminal. ... Honeywell Air Conditioners

I have a carrier A/C system controlled by a carrier TSTATCCBAC01-B non-programmable thermostat with 4 wires connected as follow: white-W, green-G, red-R and blue-Y which I want to replace with a Honeywell T8601D programmable thermostat that has the following terminals available; C, OT,OT,R,B,W,Y,O, and G. My problem is that when I connect the wires on the Honeywell to the same terminals as they were on the carrier the system seems to work but only the fan turns on while the commpressor stays off


... Air Conditioners

HONEYWELL RTH230B thermostat: we just installed the honeywell rth230b. The fan is working, but it's not turning on the outside unit. We pressed down on the thermostat slightly and it triggered the outside unit on for a split second, but it wouldn't stay on. After reading one of your forums, we disabled the blue wire, and made sure red, green, and white were in correctly. (we don't have yellow). Any ideas? The fan and vents are blowing cool air, but the house is 83 degrees and climbing (because t


Hello,what you have to do now from here is that check the capacitor if the maize i.e (wire)_ that pass current over to the compressor is well fix because this well the unit get is own supply to the over load then the relay sec ... Air Conditioners

I have just purchased a honeywell ct87n, could you please provide a schematic in order to connect it properly. I had someone install a honeywell digital thermostat several months ago, he did not tag the wires and the tenants complained that at times it was very cold and other times it wasnt cold enough. They broke the thermostat by constantly diconnecting and reconnecting it. I decided to get one that was non programable and pretty simple, I just want to be certain to install and wire it prop


G to the manufactures webpage and type in model # and look upspecs . r- red y-cool w-white g-fan .. The red should be connected to rh--rc already by a jumper wire. ... Honeywell Air Conditioners

I just replace a Honeywell T87F28733844 Thermostat with a Honeywell RTH221 Thermostat since then my the furnance will not produce any heat. I replaced the thermocouple, but still no go. The pliot light is lit, but still no go. The wires that went to the T87F are yellow, green red and blue. The RTH calls for a yellow, green, red, and white, with a jumper jack in the Rh Rc. The blower for the fan works, and the ac works, but not the heater


The heat circuit uses 2 wires to the thermostat one is the power from the transformer, and the other goes to the gas manifold.\015\012\015\012The Rh and Rc is probably the power for heat and cool, and this is where the red would attach IF ... Air Conditioners

I currently havea honeywell thermostat model# T8112D1005 (1) 0347 PF2A and a replacing it with a Honeywell TX1500E. My only issue is my old thermostat has a "R" wire that was connected up to it and my new unit only shows two options "RH" and "RC" it does not have an output of only "R". My question is where do I hook up the wire marked "R" from my old unit or do I even hook it up? The instructions mention if replacing a TM-11 to tape off the R wire and hook up the B wire to the B terminal. Im nit


... Honeywell Air Conditioners

Hello I am installing a new slant fin boiler system, EC-10 oil fired unit. 2 Zone Valves are V8043G. My problem is how do i wire in the Stack Relay switch type RA116A all equipment is Honeywell except thermostats they are White-Rodgers 1F78. The Honeywell system in the boiler is L7224/L7248 Electronic Aquastat. Plus how to wire in thermostat. Thanks for your help Rob. email addy [email protected] if you have to send me anything. Thanks again


... Honeywell Air Conditioners

Honeywell thermostat Setting a Honeywell thermostat


Honeywell has made a huge number of thermostats over the years. Directions for each are specific to each model. Your model number will begin with the letters, T, TH, RTH, C, or CT and is on the back of the thermostat.Once you have the model num ... Air Conditioners

LENNOX HS26-048-3P Installing Honeywell wifi thermostat. C terminal on control board was connected to X on the old thermostat. The X terminal wire on the old thermostat is connected to the C terminal on the control board. I used this wire to connect to the thermostat C terminal and now the compressor fails to come on. The slow flashing lights indicate the thermostat is asking for cool and the fan comes on, compressor does not come on.


... Air Conditioners

Hi The old thermostat broke down and the AC technician bypassed the thermostat on our external Brivis Buffalo. I have a new programmible Honeywell Pro 8000 Thermostat, however when the electrician installed it. It still is not being regulated by the thermostat? How do I remove the bypass of the thermostat? Hope you can help Neil - Canberra


Well, how did he bypass the thermostat? Is it just a wire? First turn off the power to the unit and then simply remove the bypass by cutting it out or unscrewing it. I'm not exactly sure what he did, but if you take a picture and post it here of t ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific