Friedrich Mini-Split blowing fuse

\015 I have a Friedrich Mini-Split AC unit that keeps blowing the 10 amp time delay fuse.\302\240 After replacing the fuse the unit will run for 20 to 30 minutes and then blows the fuse again. Any ideas?\015

Answers :

Low voltage shorts can be a real pain to find!!! i would try a process of ellimination: first i would try to elliminate the thermostat. then id look for a wire that is vibrating on something in the cabinet.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Friedrich Mini-Split blowing fuse


Low voltage shorts can be a real pain to find!!! i would try a process of ellimination: first i would try to elliminate the thermostat. then id look for a wire that is vibrating on something in the cabinet. ... Friedrich M18CE Air Conditioner

I have an Energy Knight mini split unit. One works fine the other drips condensation EXCESSIVELY. Is something wrong in the unit itself or could the drainage tube be plugged inside the wall. If so, whats the fix? Also, I have another split unit and neither will turn on. This question was asked previously and it sounds like the fuse in the outside exchanger. Exactly how do I get to this fuse to check? Thank you.


... Comfort-Aire HMC24AD-1 Air Conditioner

Friedrich MR36TQY3F tri zone mini split system


... Air Conditioners

I have a Fujitsu 18C1 split type AC system that does not power up at all. I replace the condenser unit fuse and the wall unit fuse, but the system continues to blow fuses on the wall unit only. What might be wrong with my system?


When you say wall unit I assume you mean indoor portion that circulates the cool air or the evaporator. Check to see if the fan will turn freely when unit is off. This fan should spin free. You could have a bad fan motor a shorted capacitator. This ... Air Conditioners

E6 error I have a new Friedrich split A/C unit (ten days old). Just ran it for the first time and after a couple of minutes, E6 shows up on the display panel on the wall mounted unit. After some detecting, I discovered that the unit outside never comes on. The wall unit does blow but it seems to just be blowing air (yes, I have the remote set to "snowflake"...but the "snowflake" light on the display panel also turns off after the initial couple of minutes. I HOPE the problem is not in the wall (


... Air Conditioners

Friedrich Mini-Split system with dead-band problem


... Friedrich Air Conditioners

Energy Knight AC Blowing Fuses


My Energy Knight mini split air conditioner does not come on at all, no sound no lights nothing. I have changed the batteries with no luck. please help ... Comfort-Aire HMC24AD-1 Air Conditioner

LG 9000 BTU Mini Split model -outdoor side accumulates heavy coat of condensation (ice) and cold only blows from right side. How do I maintenance it the blades are very dirty also. Is the thermostat p


... LG LS-J0910HL Heat & Cool Mini Split Air Conditioner

Oil Leak My 2-month-old, self-installed GE 2-ton mini-split unit is quiet and blows super cool air, but I find a small drop of yellowish oil on the lower left side every morning. Is that compressor oil? How is it getting into condenser unit? Is it a loose copper fitting? How can I fix it?


This would indicate a leak somewhere in the condenser sheet coil. I hate to be the bearer of bad news but you should call a service tech in to fix this problem. ... GE Zoneline AZ38H12DAD Split System Air Conditioner

I also have a grunaire dual zone mini-split that doesn't work worth a ****. I've had it looked at multiple times and had freon r410a added twice and still nothing. Without the high side - how do you know if you put too much or not enough. I also have a long run on one system being over 25ft from the compressor so its a longer run - but that one at least worked for a moment - the short run - never worked. Get the FC fault consistently on one unit - other unit just doen't blow cool - how do yo


An FC fault on a Grunaire is typically a defective PFC board in the outdoor unit or a Grossly overcharged system, where the drive cannot overcome the standing pressure to start the system up...the ONLY CORRECT way to charge one of these u ... Air Conditioners

Mini split. Outdoor unit runs for 5 min, then shuts down. Indoor unit continues to run, just blows cold after outdoor unit shuts down. Refrigerant level is good


... Soleus Mini Split Air Conditioner

No heat We had the mini split installed and have not needed the air conditioner yet. But now that I want the heat on, I can't get any. The indoor unit lights up and the fan comes on but only blows cold air. I have checked everything I dare to, and noticed that the outside unit doesn't seem to be running. I am reluctant to call the guy who installed it because he was not a happy guy to do it in the first place. But he was the builders choice. Any suggestions of things to check into myself?


From my experience, when a new heat pump unit doesn't switch over from one to another, its most often the thermostat isn't wired correctly. The reversing valve needs energized or the common is ... Sanyo 09KHS51 Ductless Mini Split Air Conditioner

I have an Innovair/Multi Zone, 12000 btu/h Inverter mini split console displaying EF error code after cooling for about 2-3 minutes and then blowing hot air when this error code appears. Then, after 2


... Air Conditioners

My Innovair elite mini split AC has multiple prolems. 1. The coils are making ice. 2. On or Off it displays C2 3.Although I cleared the tracks still dripping water. 4. Just blowing cool.


There should be a label on your AC system with a model number specific to your unit. Please reply with the exact model number and we can further assist you. ... Air Conditioners

I have 24000 BTU Mini Split Conditioner AmcorAir Brand with Toshiba Compresor. The unit was purchased in January and Instaled in February this year. I did not used as match. Now i am not able to use. There is messege in the display P8 and unit is only blowing air. What is the problem?


Is The compressor coming on ... AmcorAire UCHW-H24AF2 Split System Air Conditioner

I have a mr slim model PUY-A18NHA3 Mini split. it is completely installed however it will not get cold it blows room temp air. I have checked for leaks and have none. i am not sure why it will not get cold.


You need to check the protection for the compressor has not failed. Other causes can be\015\012thermostat / pressure switch\015\012Low gas pressure\015\012Maintenance codes - any showing?\015\012Operator settings - timer/sleep/fan only etc.. ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

Amcor 12000 btu mini split only blows heat and does not switch to cold. compresor seesm to run continously


TECH SUPPORT AVAILABLE @\015\[email protected] ... AmcorAire UCHW-H12AF2 Split System Air Conditioner

I have unit 48bne018301 mini split unit. For 2 summers now it is blowing a black substance almost like insulation all over, I have had the a/c man out 2 times and he has no idea. this substance is ruining everything it touches. there is no way to get tothe back of the unit under the coils, i dont know where to go. i am pretty upset since i feel something inside the unit is breaking down, and the reason i chose carrier is for the quality.please help. tel 252.261.5406. thank you


I have not heard of this in the Carrier mini splits, but sounds like you are on the right track, the back side of the indoor section is plastic and styrofoam, it could be breaking down. Did you check to see if the air filter is breaking down? \ ... Air Conditioners

SAME PROBLEMS 18k btu mini-split sys turn on blowing cold air for 3 mins, then turns warm for 3 mins then shuts down however the run lite blinks at 4 times intervals. outdoor unit fan alway runs at slow speed, even at start up. cleaning outdoor fan cleaning dont help. whats next? maybe the caps? thanks mike (us navy) at [email protected] in norfolk,va FAN MOVES FREELY, EVEN BY WIND BLOWN.


Glad to hear the issue is resolved.\015\012\015\012With regards. ... Air Conditioners

Friedrich 12,000 split unit is not blowing cool air. if I did not vacuum out lines when installing a 15 foot run can that be problem? how to fix?


The only person who can fix that now is an AC engineer ... Friedrich M18CF Split System Air Conditioner

My air conditioner is blowing hot air instead of cool air.. what is wrong with it? I have a Freyven mini split and the compressor turns on and off in a matter of seconds. It doesn't cool the room at all. It has The R-22 at the correct specifications but I just can't seem to figure it out. I have had several so-called technicians come and check it but it is still the same. What is the problem.


First if it turns on and off does this trip the breakers?? I'd recommend you to change the combination capacitor and check against wiring diagrams probably a misplaced wire that can do what your describing. check that you have your remote set on cool ... Carrier 38CKC042 Air Conditioner

I have a LG mini split system AC/Heat pump. The unit does not come on. I has power but does not become activated with the remotes or the manual on/off switch. Is there an internal fuse?


Small internal fuse. You may need a service tech to check this out. I buy fuses for them at Radio Shack. Sometimes there are more than one board bit it is the large amin board where the transformer wires hook into the board. If you have trouble just ... LG Air Conditioners

Celiera 12000 btu Mini-split ac unit blows cool air but not as cold as in the past. Unit has been installed for 3 years and functioned fine until now. Is it likely that I simply need additional freon?


It's 'possible' but not likely that you need additional freon.\015\012\015\012What is more likely is the 'filter' (for inside coil) is dirty and possibly the coil itself - and/or - the outside coil is dirty.\015\012\015\012I w ... Fujitsu 24R1 Air Conditioner

Daikin ducted split air conditioning unit, The F2U fuse keeps blowing, why?


... Cfm Daikin R410a Split System Air Conditioner

I have a 24 ton mini split, that has never worked correct. It used to blow cold air, but only for a little while, then it set error codes including p4, and p8. The heat functioned used to work ok. Now it just sets a FC code, or failed compressor. The supplier would not warranty the unit, so I am stuck with a dead ac, and 2000 dollar bill. Is there any hope.


Code P8Error detail Abnormality of pipe temperature.Inspected unit Indoor. Due to non condensable gas/over charged/condenser dust blocked.For non condensable gas, remove gas and flush out and then recharge gas./re ... AmcorAire UCHW-H12AF2 Split System Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0506 seconds