Having problems with your Air Conditioners ?

Central air conditioner doesn't cool

\015 The central air conditioner in our house doesn't cool.. any help would be appreciated.\015

Answers :

A central air conditioner that runs but doesn't cool may just need to be cleaned. Plan to do this on a relatively warm day. First look for your owner's manual and, if you can find it, follow its instructions. If you can't find it, request one from the manufacturer (see Resources).\015\012\015\012To clean the filter, remove it from the furnace or air handler (it?s usually located inside or very near the air inlet side). Replace a disposable filter or clean a reusable filter according to the manufacturer?s directions.\015\012\015\0121) Before you begin, check the thermostat to make sure it is set to "cool" rather than "heat." Then turn off the power to the unit; there is normally a shut-off or disconnect panel on the house wall next to the outdoor compressor. Otherwise, shut off the air conditioner's 240-volt circuit at the main electrical panel.\015\012\015\0122) Rake leaves and debris away from the outdoor condenser.\015\012\015\0123) Remove any protective grille or cover from the condenser's fins.\015\012\015\0124) Use a soft brush to clean dirt and debris from the fins, then vacuum them with a brush attachment (be careful not to bend or damage them). If you accidentally bend fins, you can buy a comb made for straightening them at an appliance parts store.\015\012\015\0125) Unscrew and lift the top grille off the unit, if possible. If the fan is attached to the grille, be careful not to pull any wires loose.\015\012\015\0126) From inside the unit, hose out the fins (protect the wiring and motor with plastic). If your owner's manual calls for lubricating the motor, do that now--don't over-lubricate.\015\012\015\0127) Then reassemble the unit.\015\012\015\0128) To test it, turn the power on and set the thermostat to turn the unit on. Let it run for a few minutes, then feel the two pipes that connect to the condenser unit (slide any insulation back). One should feel warm, the other cool. Otherwise, call an air conditioning technician--the refrigerant may need to be recharged.\015\012\015\012NOTE: Avoid straining an air conditioner's compressor by waiting at least five minutes between turning it off at the thermostat and turning it back on.\015\012\015\012Air conditioner or heat pump still giving you trouble?\015\012\015\012To Home Problem Solver Main Page\015\012\015\012Copyright. All rights reserved.\015\012\015\012Interested in licensing this DIY Content?\015\012\015\012Related terms: what to do if, how to fix, troubleshooting, DIY, air conditioner doesn't cool, air conditioner too warm, warm air from air conditioner, air conditioner not cold enough, how to clean air conditioner, cleaning air conditioner, air conditioner cleaning
Usually when a unit isn't cooling it is because one there isn't enough freon in the unit. Second there could be a compressor gone bad. Third there could be a circuit short out. It can be very simple and it can be costly. It just needs to be checked out by someone who has understanding in this area.Look for an affordable service man or company in your area whom most people may be using to come out and check it out for you. They would be glad to. They can let you know about what it might cost also. If you have understanding in this area you might do it yourself. I do most everything myself and it keeps alot of money in my wallet.\015\012But I have to take the time to do it.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Central air conditoner unit doesnt blow cool air into home has some ice on the inlet heat and cooling lines going into the central air unit


Change the furnace filter. Make sure you use a cheap one when air conditioning, as the better ones restrict airflow when they filter out so much stuff and then plug up, not allowing enough air to pass over the cooling coil in the furnace's air plenu ... Carrier Air Conditioners

We just turned on our central air conditioner last night. today the temp of the house was 80 degrees. someone in the household placed the tempature on 70 degrees cool on auto. we have not felt any air coming out of the vents. the central air unit is running. any idea why this happened. our thermstat is not programmable.


Did you hear the indoor unit running (the fan blowing)? If so, there's a good chance that either the filter is plugged or more likely, the evaporator coil is iced up and preventing any air from flowing into the dwelling.\015\012\015\012T ... Air Conditioners

Central air amana model vca24b2e not cooling - Amana GSX130301 Central Air Conditioner Condensing Unit 13 SEER 2.5


... Amana GSX130301 Central Air Conditioner Condensing Unit 13 SEER 2.5

Air conditioner not cooling - Ruud Central System Air Conditioner


Your problem description is quite broad. There are a variety of factors that may cause your AC to not cool your house. With that said, given your ambiguous description, I can offer you a diagnostic article that provides the most probable causes of y ... Ruud Central System Air Conditioner

Have an amana central air duelfuel heat system.when aux heat[gas] heats the house and shuts off the fans still blow for 3 to 5 minutes with the last couple of minutes being cold air which cools the air it just heated. also heatpump will start heating when it comes on then after 3 or 4 minutes it starts blowing cold air like when the air conditioner is running.i have had problems from day of install 4 mounths ago with problems that keep coming up. please i need help fast i do not think comp


Change your heating delay to shut off sooner, you can find this in the installation manual. Also the Thermostat may have delay after heat as well. It is true there could be many variables, but it also sounds like the Heatpump is not charged properl ... Amana Air Conditioners

My central air conditioner turns on and only hums but fan does not turn and does not cool what could be the problem?


... Air Conditioners

Central air conditioner doesn't cool


The capacitor is located inside the control panel on the outside unit. It is round or oval and silver in color.It runs the outdoor fan and the compressor both.\015\012The terminals are marked= C, /F or fan/, H or herm. C-F-H.\015\012The m ... Air Conditioners

Central air conditioner doesn't cool


A central air conditioner that runs but doesn't cool may just need to be cleaned. Plan to do this on a relatively warm day. First look for your owner's manual and, if you can find it, follow its instructions. If you can't find it, request one from th ... Haier Energy Star ESA3183 Air Conditioner

My central air conditioner is putting out cool(weak) air, not cold air


Number one problem is lack of air flow usually due to dirty filter or dirty evaporarator or condensor. Clean and service both , first before anything else. ... Ruud UBHC Air Conditioner

I have a Coleman Central Air/Heat System. This year, the outside compressor (or whatever it is called) is shutting off within minutes of the air conditioner coming on. This is resulting in the home never cooling down. I can reset the system by shutting the air off inside the home for a few minutes and the outside compressor comes back on, but again, only for a minute or two, and the unit only blows what seems to be room temperature air.


Do you know the devices model. It would help in locateing the manual. also I beleave you have the manual?\015\012\015\012As micromaster already said, check for sleep timer.\015\012\015\012has the system worked fine before has ... Air Conditioners

I have a Bryant 561C central air, 5 years old, The Motor on the outside unit of this air conditioner went out, trying to sve some money on a service call I ordered the new motor and put it in my self and was able to make it run but no cool air inside the house. The motor that I took out was made by General Electric with three wires coming out of it, now the new motor I bought was made by Emerson with 4 wires coming out of it, also the lady from the Bryant dealer where I bought the motor also sen


Hi there, \015\012\015\012here is the wiring diagram of you air con unit...\015\012\015\012http://w ... Air Conditioners

Coleman outside mounted air conditioner in park model doesnt cool sufficiently


... Coleman Air Conditioners

My central air conditioner is just blowing warm air ..it is not cooling ...


Hi there,Sound like your unit may have a refrigerant leak and has lost pressure may just need to have it recharged. outside things are work as they should but without the proper pressure it will not cool down inside.Good Luck! ... Air Conditioners

My Fujistu AST9LSACW split system air-conditioner wont blow cool air. the outside unit AOT9LSAC doesnt seem to be working at all. The power light stays on but the timer light flashed about 15-20 times a minute. please help...


There are two things you can check outside before calling a service technician. The first is the breaker to the outside unit. There is a breaker or disconnect near the unit. If there is nothing wrong with the electrical supply, check the refrigera ... Fujitsu Air Conditioners

My central air conditioner is not working properly. It doesn't get cold. All it does is cool air comes out and the house doesn't get cold. What do I do?


Well how cool is cool check temp at one of the register should be around 54 degrees. if so you other problems ... Air Conditioners

My central cooling system does not work. Every things is working accept a compressor. When I turn on the cooling system the compressor makes strange nose and after one minute it turns off, but fan kips continue to work. Do you have any suggestions for me? Thank you Model # of my air conditioner is CCU10A42A-1


Compressor overload on the compressor ... Air Conditioners

It doesnt blow cool air - Kenmore 72055 Air Conditioner


... Kenmore 72055 Air Conditioner

Air conditioner comes on fan only. the compressor doesnt seem to be coming on. the is no cool air blowing. the unit is brand new and was jusy installed.


There will be option in remote to on the fan and compressor separately may be you would not have on-ed the compressor through remote or else there would have been any loose connection in the wire which connects the compressor ... Friedrich Air Conditioners

My central air conditioner is not cooling. The liquid line was extremely hot, you couldnt touch it. I cleaned the condenser, evaporator and filters. Suction line is cold liquid line is warm, still not cooling


... Ruud UBHC Air Conditioner

When Haier YL M07 air-conditioner is on the Power/Health indicator light is orange colour. The air from the cooling unit is not cool. When I press the HEALTH button the Power/Health indicator light turns green but the air from the cooling unit is still not cool. I would like to know what has gone wrong with my air-conditioner.


... Air Conditioners

Fan on unit will not turn on in cooling mode - Ruud Central System Air Conditioner


Check to see if the green thermostat wire is conneceted to the "G" terminals on the thermostat and on the furnace. ... Ruud Central System Air Conditioner

Doesnt cool well - LG LS-L1210CL Mini Split Air Conditioner


Hi,Here is a tip about troubleshooting your air conditioner...There are many things that can cause your air conditioner not to cool... ... LG LS-L1210CL Mini Split Air Conditioner

MY CENTRAL AIR CONDITIONER IS RUNNING BUT NOT COOLING


If your house is not getting cold enough when your A/C is turned on, It is time for a good cleaning. There are a variety of factors that may cause your A/C to not cool your house. With that said, here is a diagnostic article that provides the most pr ... Air Conditioners

We are type testing a 4 Tons water coled Air Conditioner with water cooled Brazed Plate condenser which has water inlet froma 1 HP Pump form the water tank. The AC uses Copeland Scroll Compressor, TEV/Filter dryer & a sight glass. The problem is - the discharge pressure varies between 250-300 PSI & doesnt settle down.


Check that the brazed plate condenser is verical and plumb. Variance can occur when the condenser is moved out of a plumb position to a horizontal position as it affects the free condensation area when the freon gas first enters the chamber. Some dis ... Air Conditioners

[email protected] My central air conditioner is not cooling my house


Wow, your problem description is quite broad. There are a variety of factors that may cause your AC to not cool your house. With that said, given your ambiguous description, I can offer you a diagnostic article that provides the most probable cause ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific