Having problems with your Air Conditioners ?

No cooling My room air conditioner doesn't cool. what do I do?


Answers :

F8 displayed
Is the a/c blowing warm air? If the coolant is not the issue, it may not be an efficient a/c, and has frosted up inside. Turn the unit off, and let is defrost. This will take several hours, but until the ice is gone, it will not allow air to blow through.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Air conditioner Artic King window air conditioner is blowing cool air but not cooling off the room. What is the problem. It worked last year and we can't seem to cool off the room....


You need to check the evaporator to see if it needs cleaning. You can check this by taking a dollar bill and see if it will hold it in place while running. Inadequate airflow will cause poor performance. Unfortunately ,this is something that would re ... Kenmore 72059 Air Conditioner

My whynter sno portable air conditioner blows air but it isn't cool. The air outside the room is actually cooler than the room with the air conditioner. Why won't it cool? I have the temperatu


... Whynter SNO 13000 BTU Portable Air Conditioner

Does this unit dehumidify the room in which it is running, or just the air from the intake? As I understand it this dual hose air conditioner does not interact with the air inside the room it is cooling other than blowing the room air over the compressor to cool it...though I think I just answered my own question, as the humidity would condense on the compressor from the air inside the room, while the dual hose is designed to get rid of heat without creating a vacuum. Thanks.


Yes it does. Whenever you cool air, you reduce the amount of water vapor it can hold. As a result, if you are cooling room air you are automatically removing some of the moisture from the air as well. The condensate is probably re-evaporated into ... Air Conditioners

I own a Zenith Air Conditioner, model ZW651OR. It is only a month old and it is not blowing cool air any more. I live in Guam (relatively a hot climate) the size of my room is 10' X 12' and the air conditioner runs pretty hard to cool room, what could be the problem


The problem could be dirty filters, dirty coil, refrigerant charge low,etc. Since it is only a month old I would try to return it if possible. ... Air Conditioners

It freezes and doesnt cool the room. - Air Conditioners


After it completely defrosts and all the ice is off. Try starting it off with fan on low and temp on medium and make sure the intake isn't obstructed at all and the coils aren't plugged up with debris that has got past the filter. ... Air Conditioners

My air conditioner will not turn on. (See below for a more detailed description.) I recently bought a used Kenmore Room Air Conditioner Model 580. 76129. It worked well for about a month (running almost continuously, usually on either energy saver or cool). About a week ago, I walked out of my room when the air conditioner was on, and it was off when I walked back in about an hour later. (The display was unlit, and it was not making noise.) The power button still does not work. The outlet


If you have a GFCI plug on A/C unit it may need to be reset at the plug. ... Kenmore 76129 Air Conditioner

Hi, thanks. I have a question regarding the portable air conditioner cvp10nc as I am preparing to purchace one. Is the air from the room being cooled recirculated exclusively through the unit and all put back into the room? Or, is some of the air in the room where the where the unit is cooling sent out the exhaust? Also how many amps does this unit draw? Thanks so much Kerry


Hi kerry have tried to look for the model number as mentioned by you hwever was unable to find that on the sharp site however they do have two other models namely CVP10PC and CVP10RC for which i am providing you with the link here you can get whateve ... Sharp CVP10NC Air Conditioner

Recently bought samsung multi split 3 rm air conditioner. 2 of the room air con working fine but the 3rd room fan coil seems to be blowing only cool air not like the other 'aircon' feel coolness. Got the technician to top up gas but same problem persist. Help!


Doesnt sound like a gas problem. theres a vavle they opens and closes inside the unit that might be playing up either the vavle or the indoor pc board. did it ever cool ? might also be the vavle on the outside unit were not open with the alan keys so ... Air Conditioners

My portable air conditioner is running, it seems like the compressor comes on, but the temp in the room does not decline and the air from the air conditioner is not cool. I purchased this air conditioner 7/1/06 so it is still under warranty.


A few basic principles for air conditioner troubleshooting. For both central home air conditioner or window air conditioner,\015\012 the first thing to check is whether the unit is getting proper power. \015\012If the unit ... Maytag M6P09S2B Portable Air Conditioner

I have a GE room air conditioner and the digital display that normally shows the room temp now has two letters EP and the air conditioner does not cool. What does the EP stand for and how do I get it back to normal.


Following are error display codes for GE airconditioner:---Display Codes:E1 or EP error:---- Automatic filter clean reminder.Turn the air conditioner OFF and unplug it. NOTE: The air conditioner ... Air Conditioners

Cools for few minutes then stop cooling....Hi my unit GE (APH10AA) Air Conditioner, only cools for 10 minutes and then stops then is the fan that runs forever , with out getting to cool again,plus the back of the unit ,the vent takes out lots of VERY HOT AIR, my room will get so hot ,what I can do to fix it? please help


... GE APH10AA Air Conditioner

Window air conditioner keeps switching to fan mode. Which means on hot days it is blowing warm air. It sporadically switches to air conditioner mode. Room is hot because the cool air only blows for about 10 minutes. Help!


... Air Conditioners

LG LWHD8000RY6 Air Conditioner Not Cooling Room


Remove the front cover of the unit to expose the cooling coil. Put the unit on and observe if there will be formation of frost (ice) on the coil. If there's frost formation, the common cause is dirty cooling coil. Have it cleaned using an alkali base ... LG Air Conditioners

Hello, I have two Yokohama Split type air conditioners that work fine for cooling, but when switched to heat they just blow air at room temperature and then after about 1 minute go into a standby mode indefinately. They work perfectly for cooling. All fans work perfectly and the compressor works perfectly for cooling. Thanks...


... Air Conditioners

I have an air conditioner Appliance AAC 1100 A-PTC that wos working for two days and now its not cooling or heating:-( Both outer and inner parts of the machine seems to be running but it wont heat or cool the room. When i try to turn it on there is a red symbol that lights up on the display (defrosting) this light goes off every 5 minutes or so,then the machine starts to blow air (not heated or cooled) for aprox 20 seconds then the red light comes on again and this procedure starts over again.


... Air Conditioners

My air conditioner is blowing hot air instead of cool air.. what is wrong with it? I have a Freyven mini split and the compressor turns on and off in a matter of seconds. It doesn't cool the room at all. It has The R-22 at the correct specifications but I just can't seem to figure it out. I have had several so-called technicians come and check it but it is still the same. What is the problem.


First if it turns on and off does this trip the breakers?? I'd recommend you to change the combination capacitor and check against wiring diagrams probably a misplaced wire that can do what your describing. check that you have your remote set on cool ... Carrier 38CKC042 Air Conditioner

I have a fujitsu reverse cycle air conditioner,it wasnt working(not blowing cold air only room temp air like a fan).air con tech came over,re-gassed it,tried air con that day,worked fine.didnt need to use it for a few months,re-tried it,no cool air again,i am thinking of a leak.My question is the air con is about 10 years old,if cause of problem is a leak,is it worthwhile fixing it(i would need to pay someone parts and labour,could not do this job myself),or to just bite the bullet and get a rep


Hi,\015\012\015\012The A.C is 10 years old which is a ideal shelf life for the A.C. If there are any leaks I would never ever try repairing it at home becuase if there is a leak then that means that the entire GAS which helps in the cooli ... Air Conditioners

My Haier wondow air conditioner seems to be blowing cold air but it is not cooling the bedroom. It worked great a few nights ago and made the room really cold but now its not cooling.


A few basic principles for air conditioner troubleshooting. For both central home air conditioner or window air conditioner,\015\012 the first thing to check is whether the unit is getting proper power. \015\012If the unit ... Haier Air Conditioner

Air conditioner does not work on cool mode. Dry mode works but compressor turns off and leaves the room with no air circulation. What can we do to get the cool mode to work again?


... Goldstar R1203 Air Conditioner

GOLDSTAR BG5200ER I HAVE MY AIR CONDITIONER IN THE WINDOW IN MY BACK ROOM. I TURN ON AND I NEED WAIT FOR THE AIR COOL. IS TOO SLOW. MAY BE SOMETHING IS BROKEN OR IS NORMAL COOLING CAPACITY IS 5200


Measure the temp of the air blowing out. It should be 20 degrees lower than the intake air at the filter. If not, we need to dig deeper. ... Goldstar WG5200ER Air Conditioner

We have just purchased a campervan with a Dometic B3000 Plus air conditioner. The temperature has been 27c & we have set the air conditioner to 20c & the room temperature will only come down to 24c. We have contacted the people who we bought the camper, but they reckon that we can't get the temperature any lower. I do not believe this. I thought that if you set the temp to 20c, it would cool the van down to 20c. regards Marie


... Dometic Air Conditioners

My haier room air conditioner (hwr08cx7) just stopped working. The power goes on, the electronic displays light up, but fan does not blow. I also cannot adjust the mode--fan, cool, energy saver, dehum. I can adjust the temperature/speed but it doesn't do anything. Using the remote gives me the same results. The air conditioner is about a year old....


The Haier A/C unit has a small, electronic keypad on the front, right corner of the cover. There is very little you can do with it but check the wires going to it. Make sure nothing is broken or pinched going to it. The electronic module can be repla ... Haier hwr10xc6 Air Conditioner

We have this air conditioner in our sunroom. From the beginning, the temperature set is not maintained. When the unit is set to cool, no matter how high a temperature I select, the unit cuts on approximately every 10-15 minutes, and cools the room to about 66 degrees. When set to heat in the winter, no matter how low a temperature I select, the heat cuts on about every 10-15 minutes, and the room will heat to a much higher temperature than selected. Any idea what the problem is, and how I ca


Change thermostat. ... Amana PTH153B50AM Air Conditioner

I have a PACL90model portable air conditioner bought it from a friend. It does not work as well as expected. I have cleaned the filter, made sure the air hoses are vented properly and still not very cool. Do these units need to be recharged? How big of a room should they cool? Thanks for your time. [email protected]


A/C's should not need to be recharged unless there is a problem. They do not "use" freon the way a car could "use" a little oil. The best way to check is with a thermometer. Check the air where the unit is sucking in and the check the air where it ... DeLonghi Air Conditioners

I have recently purchased a Dimplex GDC18RBA portable airconditioner and it blows out cool air, however it doesnt cool down the room and the thermostat temp doesnt go down to the temperature I set it at. I had it on all night long last night and the lowest temperature it got to was 29 degrees. Please help


The air is cool but doesn't seem cold enough and does cool the room to specified temperature ,then check the following:--\015\012 \015\012If the air doesn't seem cool enough it is ... Air Conditioners

A detailed question is important to get you a relevant answers