Airconditioner problem My air runs inside the house but the fan outside is not turning...I shut everything off and turned it back on but out side i here 1 click then nothing...what is my problem??


Answers :

This unit has a bad Start/Run Capacitor or a bad Fan Motor! Replace the $10 Cap...An then the $90 fan motor if the Cap dont solve it!
Is this a central unit??? is it a split system?(Is their a unit outside(condensor) and a unit inside in the attic,under house, or in a closet??(air handler)

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Airconditioner problem My air runs inside the house but the fan outside is not turning...I shut everything off and turned it back on but out side i here 1 click then nothing...what is my problem??


This unit has a bad Start/Run Capacitor or a bad Fan Motor! Replace the $10 Cap...An then the $90 fan motor if the Cap dont solve it! ... Air Conditioners

I have a Dometic rooftop Air conditioner in my RV When I turn it to low medium or high the fan run the same speed and when I turn it to AC it will run for about 5 min then the fan will shut off but the compressor keeps running I turn it off for a min or so and everythings comes back on. Turn it to the fan only side and the fan will run for 5 min then shut off a min later it comes back on then back off and on in fan only side.


Bad fan motor I suspect The windings are bad causing the motor to over heat sending the motor into thermal overload. would suggest the replacement of motor. Good Luck on repairs\015\012\015\012Dave ... Dometic Rooftop RV Air Conditioner

I have a honeywell PA404A pressure control switch on my home gas steam heating system. I'm having a problem with the switch turning off the system. It will only come back on if I turn the top screw all the way out, then back down to approx 5psi. At this point the heat will turn on but when the thermostat shuts down the system it will not turn back on when calling for heat unless I adjust the screw again. Also, the switch will only turn on the system when set at 5 on the dial on the inside. Any i


This may be caused by accumulation of sludge in the steam trap (the looped tube that connects the pressuretrol unit to the boiler). the sludge restricts the pressure from reaching the diaphragm in the pressuretrol unit. So it gets a false reading. ... Air Conditioners

The heat pump is not working properly. i think the problem is in the switch mechanism. when the heat is on and the thermostat is turned up it blows cold air. sometimes the compressor turns on and off. if you turn the other switch to the off position, then turn the thermostat up then turn it back to heat. it will blow hot air. if you then turn the thermostat down, wait till it turns off, then turn it back up, it will blow room temp air and sometimes the compressor will turn on.


Hi,\012The problem may be the switch, but it sounds more likely that the contactor in the outdoor unit is bad and is not making all of the time...then the compressor will not always run...\012To figure it out you will need to catch it at ... Air Conditioners

Hi, I have an 8,000 BTU unit. The unit is about 5 years old. It was running fine, no problems at all. Then whan I went to turn it back on after a few days-nothing. No noise, no air, nothing. It just did not turn back on. Before this happeend it cooled, it reponded to degree changes all was fine. The green light button on the test and retest comes on, but there is not a sound from the unit itself. Its like you would hit a power button that was not plugged in (but it is). This problem occur


After changing or cleaning your Filter, you need to reset the A/C. Follow the procedures below:\015\012\015\012Disconnect the power plug from the power supply.\015\012Clean the air filter.\015\012 ... Sharp AF-S80FX Air Conditioner

My unit is 4 years old. I always turn it off when I leave for work in the am and turn it back on when I get home in the pm. Last night I turned it on at 7:30pm. When I went to the front of the house about 45 minutes later, I noticed the unit outside was trying to turn on but would immediately turn off. I checked the breakers in the garage, turned them off and back on but still had the same problem. The fan inside the house is running but unit outside will not kick on. I looked for a magic


It could be a few things.. It could be the capacitor - which the most economical to replace first..\015\012\015\012If you are not really very mechanically inclined - get a trained pro to come out.. It is very dag ... Air Conditioners

Hello, I have a Fujitronic FA1300 portable AC unit that has been malfunctioning. What happens is, when I turn the unit on, it runs for a few seconds, and then stops working. When this happens it beeps several times, and the green image on the right side of the display panel begins flashing. The image looks like a square with the top side missing, and four dots inside the box. The unit will not turn on until I hit the reset button located on the side of the plug. The problem repeats if I turn it


This is the main control board in the AC unit malfunctioning. It thinks either the unit has been opened, or switched mode, which obviously it has not. If you have tried resetting it multiple times to no avail then it unfortunately needs a replaceme ... Fujitronic FA-1300 Air Conditioner

Furnace problem I Have a 2005 Montana3295RK with a duo-therm air conditioner,suburban sf35f furnace and a dometic thermostat with remote. The problem lies with the furnace. It will not turn on, and in the rare event it does it will not turn off unless you either pull the fuse, turn the switch to the off position on the furnace or turn the gas off at the tanks. I can force the furnace to come on by pulling the fuse and then putting it back in and the thermostat does not have to be in the on posit


The problem is most likely in the control module of the roof air unit. Dometic uses the thermostat to activate and deactivate a relay in the control board of the roof ac unit whiich is just visible when you remove your air intake screen. The two blu ... Dometic Rooftop RV Air Conditioner

Roommate turned off our Electrolux Kelvinator split air conditioner using the auto cool, under the hood. Now the remote doesn't turn on the air conditioner! Just had a electrician fix the problem by turning off the main supply and turning it back on. Worked fine, back now I'm stuck in a hot house again. Please help!


... Air Conditioners

Not as much heat coming into house as was before,went to heater unit which has 2 60amp breakers on unit and while running turned off top breaker and came back upstairs but did not feel any difference in heat temp, went back to unit and turned off bottom breaker which turned of all heat plus blower motor. what is my problem?. thank you


First what type of heat do you have and if you can find the model # it would be helpful. Also if you have filters check them. ... Air Conditioners

Conditioner fan runs but compresser shuts off after only a few minutes and doesnt turn back on.sometimes if i tap the side of the unit the compresser turns on but only to shut off later and not turn back on by itself. danby window model DAC5088M


From your description, seems like compressor is seizing when hot, tapping it shakes the piston loose then it seizes up again after a while. ... EMI EHW 18000 Air Conditioner

2003 expedition,a c not working freon is ok fuses ok clutch dosn't engage, a would like to know what else to check clutch, sensors,delays, etc. That is the main problem now cuz Sumer, I really like to check every single lead you can Share to get to the problem. Also problems that now i know Thanks to you guys are typical on exps like: - a c tap noises on the back - ajar door sign always - driver electric seat works left side ( or left rail ) not the right just on d side - ceiling lights fronto


... Air Conditioners

Sharp Air Conditioner AC09RLCSYS isnt cooling properly. Very moderate to low cold air from unit. At one point small bits of ice came out of indoor unit when on auto cool. Unit was switched off immediately and then turned back on after a few minutes with no additional problems, however still is not cooling properly. Unit is only eight months old. First used for cooling with no problems and great cold air, then for heating during winter. Now back to cooling and not getting the cold air like p


Unit may be freezing up if blowing ice crystals. Let thaw 24hrs try again. Make sure condensation drain line is cleaned out. ... Air Conditioners

I have the fujitronic 1400 portable a/c. The problem is when I turn it on it will run for half an hour sometimes more some times less and then it just shuts off. Also I noticed that some times when I touch the side of the unit it will cause it to turn off or on and im not touching anywhere near the control panel. not sure if that is related to the problem. any help is greatly appreciated.


... Fujitronic FA1400 Air Conditioner

I have a whining sound coming from my Air Conditioner in every mode except Fan. I cleaned the back part of the the unit with a duster and the sound continues. I also could duplicate the problem after turning off the unit for about 10 seconds and then turning it back on. Does a part need replacing?


I am assuming this is a window unit. That whining sound probably is the compressor itself. Not much you can do about it but wait till she goes on out and then replace it. They do make a product that can be added to the compressor called Gemline 88 oi ... Air Conditioners

I have a DeLonghi CF210 and I'm getting the "E3 Fault" code on the main screen. It will not power up in Air Conditioning mode, but the fan mode will run. I saw where someone suggested it is a voltage problem, and have tried it in several outlets to no avail. This problem happened to me about a week ago and I turned it off for a while (10-20 minutes), then turned it back on and it worked again for a week before giving me the E3 Fault error today. I do not have the financial resources to sen


Remote controller comms error. Check wired correctly, if so check dipswitch in RC. Set to Sg for 1 unit, or Gr for group then reset power ... DeLonghi CF210 Portable Air Conditioner

Electrical Schematic?? Hi, Here is our problem:  We have this unit installed in our desert vacation home in the wine "cellar" room, at times when we are not here, the electricity has gone out (even just for a second) and this unit shuts down and doesn't come back on until we come here and physically turn it on again. We are looking to bypass this so we don't have wine ruined while we are away.  How can we get this unit to come back on by itself?   Another problem is: this unit is installed in su


An easier solution would be to connect it to an UPS. May not be the cheapest though. ... Hitachi RAS-09UH Air Conditioner

I have a Vaillant combicompact VCW GB 242 EH . The hot water is not consistent. I can be having a shower or just washing my hair, when the water starts to come through to hot, I turn the cold on a little after a little while its freezing turn off both taps and turn hot back on and its cold for ages... turn off turn on again... then after a while its hot then the same problem happens again. Any Ideas ? Thanks in advance Emma


... Air Conditioners

At 30,000 miles my then 8 or 9 month old chevy 2500hd 4wd pickup truck air conditioning started blowing hot air on the driver side (the passenger side was still cold). I turned the truck off and back on and it began blowing normally for a few days and then it would do it again. A year or so later the heat on the driver side went out totally (passenger side worked properly). So now the driver side blows cold air constantly. A few months after that the blower quit working all together. Now at 185,


What year truck is this? This is actually a very very common problem on those chevy trucks. Most times it is the door blend actuator that has failed. and the default for this failure is driver side blowing hot. There are a million posts out there on ... Air Conditioners

My fedders aircon compressor does not turn on again whenever its thermostat turns it off. what i had to do is unplugged the power cord and turn it on again to work. i already replaced the capacitor. what i observed is that the big normally open rely does not switch on. maybe a board problem? if i turn it off and turn it on again, only the fan rotates and not the compressor. i had to unplug the power and put it back again for the compressor to run again.


You have a time delay build in on the pc board of 3 minutes. If it takes longer than 3 minutes check your compressor overload protector, Maybe the compressor is overheating, check your coils for proper air flow. ultimately if the compressor checks ok ... Fedders A6X05F2D Air Conditioner

My hydropool spa is tripping the circuit breaker. I moved my hottub off the deck onto a concrete pad next to the deck last summer. No problems, then over the first winter I went out one day and the breaker had tripped. I reset the breaker, no problems, happened two more times during the winter. I reset the breaker - no more problems. I should say that I was using the hottub during the winter and into the spring time with no problems. Now the breaker tripped and wouldnt turn the tub back


It sounds to me like your hot tub has bugs take the control panel apart and clean the bugs out of it. if you have ants in the area they will get into the controls and cause it to trip out. i had similar problem with apump until i found the ants ... Air Conditioners

I have an Amana central air/heat unit. Model PHCB10C1 Serial # A040900070 Manufacture # P1219409C, Cat # 81K95. The problem I am haveing is the unit will not kick in(heat). When I turned off the main pwer and let off for about a hour and turned back on the unit ran fine for a couple days. Now the unit will not kick in at all even after turning the main power off and on to reset the unit. I have a brand nre thermostat in the house. When I turn the fan from auto to on the fan runs and blows out


... Amana Air Conditioners

I have the mitsubishi mr slim indoor model msz-a09na in my living room and bedroom, upon awaking this morning the living room was noticably cooler than the 64 degree setting ,i then noticed that the left indicator light was blinking, when i turned on the bedroom unit the same thing happened, i turned both units off for 5 minutes when i turned them back on they appeared to be working ok, this also occured about a week ago... i notified my landlord but he doesn't think this is a problem?


... Mitsubishi MS09TW Air Conditioner

Shut unit down for cleaning, outside unit will not start now, I have line voltage at the contactor but the contactor will not engage.one wire from the thermostat runs to a little black box next to the contactor (white) the red one runs to a device down by the dryer on one side and back to the black box on the other side. Both of these wires come out of the box and attach to either side of the contactor.Could this piece be the problem or is it the black box.If I manually engage the contactor the


You are talking about the low voltage transformer ... Ruud Handle Air Conditioner

Our Carrier 38ckc036350 is not working - the outdoor unit was very hot to the touch and will not turn on -turned it off at the thermostat - later when the unit cooled down turned it back on via the thermostat and it would start to kick on, but then stop - no breakers were thrown. Unit will be 7 years old in the middle of July '10 and am wondering: 1. what could the problem be & 2. will any of this be under warranty?


The first thing I would check is to see the condensing coil is clean. Take a garden house and wash it thoroughly. If it is severely clogged you may need to remove the top and clean it with water pressure blowing from the inside out. This may stop the ... Carrier 38CKC036 Air Conditioner