Having problems with your Air Conditioners ?

Air Conditioner malfunction

\015 Central Heat (Gas) and Air system is blowing 3 amp fuses on control board. Unit specs follow:\015\012Carrier Product 58GP-050---111EA\015\012Model 58GP050-EA\015\012Serial # 2791A02092\015\012\015\012Have replaced fuse, checked Ckt Brkrs and other fuses, manualy engaged compressor relay (outside), searched for any frayed or loose wires, replaced thermostat, bypassed Hi/Lo limit switches. Blower runs continuously, even with unit set to "OFF".\015\012Any Ideas????\015

Answers :

Hi, Sounds like you have a short in the control circuit to me. Turn off all power going to the unit. Write down or otherwise mark the wires leaving the control board going to the thermostat. Remove them from the control board. Replace the fuse. Turn power back on and see if the fan still runs. If it does, check and or replace the heat limit switch that brings the fan on during the heat cycle. It may just need adjusted. If the fuse blows, I would think that the control board is probably bad. If it doesn't blow, Remove the thermostat. Leaving all thermostat wires open check them with an Ohm meter. There should be no continuity between them. Twist all the wires together at one end and ohm them again at the other end. You should have complete continuity on all wires. If the wiring checks out, down power the unit. Double check your wire colors and rewire the control board. With all wires open at the thermostat, turn the power back on. Touch the RED wire to the YELLOW wire. The Condensing unit should come on. Touch the RED wire to the GREEN wire. The fan should come on. Touch the RED wire to the WHITE wire. The heat should come on. Down power the unit. Replace the thermostat. Test unit. If the fuse has lasted ok but blows now it is either wired wrong at the Thermostat or the thermostat is bad. I hope I have helped. NOTE: If you can not understand these instructions. Call a licensed Heating / Air conditioning company.\015\012kstfas
Geiger-Air conditioning includes both thecooling and heating of air.
It also cleans the air and controls themoisture level.
Air Conditioning Contractors Directory for Cincinnati,
Prescreened Home Improvement Professionals for Cincinnati.
<a rel='nofollow' href="http://gogeiger.com/"> gogeiger</a>

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Re : Carrier Xpression P1/P2 Plus series I have a query about the above Air-Conditioner. I have removed the Air Filters, and cleaned them. I have also removed the optional Photo-catalyst filters (2). I had not realised until I cleaned them that they were slightly different. One has a green mesh-like back, and the other has a black backing. Can you please tell me which sides these should be placed back in the air-conditioner please, as I don't want to cause a malfunction in the syste


These filters should have a arrow on the perimeter that points in the direction of the air flow. Most all filters do, so look it over good.From working with these filters in the past, the green mesh would be the way the direction of the return air wo ... Air Conditioners

My portable air conditioner Model # AP077R, is not functioning correctly. I just opened it last night and now it is malfunctioning. Once plugged in, it will act as if it is cycling between blowing air, then stopping, and starting again. I can not turn it on or off. It runs through this cycle by itself and the only way to stop it is to turn it off. Do you have any suggestions, or is it just defective?


Yes it sounds defective from fatory and should be exchanged. ... Amana Air Conditioners

Air Conditioner malfunction


Hi, Sounds like you have a short in the control circuit to me. Turn off all power going to the unit. Write down or otherwise mark the wires leaving the control board going to the thermostat. Remove them from the control board. Replace the fuse. Turn ... Air Conditioners

The main power supply was cut off but after it was back,my Fuji air conditioner RSW9CB can't be switch on. The red 'Öperation' light blinks twice(continously) and the green ' Timer' light blinks continously. Main connections and the remote controller are all in good working condition. My guess,it could be from the malfunction from one of the sensors. Pls help me. MSF Tq


Check input connection in indoor unit, may be loose contacts. And also your room thermostat sensor may be defective. ... Air Conditioners

Daikin malfunction codes j5 - Air Conditioners


... Air Conditioners

Friedrich air conditioner stopped running. I was trying to find what the air conditioner was causing to vibrate near the unit. I moved the power cord while the air conditioner was running, pushed the wall plug to make sure that it was tight. THe air conditioner stopped running. I am a woman with no mechanical knowledge. My instinct tells me that I might have blown a fuse or short circuited something within the air conditioner.


This is very possible. Whenever a compressor is unplugged it should rest for about 5 minutes before turning it back on. This is because the refrigerant needs to balance. Otherwise a large amount of amperage may be required to start the compressor as ... Haier hwr10xc6 Air Conditioner

My 3-year old LG air-conditioner was leaking water. So i called some 'experts' to come fix it. This is the first time I called for maintenance service on the air conditioner. The 'experts' dismantled some parts of the air-conditioner and washed out a lot of dirt and sticky stuff. After they put the air-conditioner back, there was no more water leaking but I noticed 2 new problems. When I switch on the air conditioner, the mouth does not immediately swing open, it takes about 3 minutes before it


White snow.. I had this issue when 2 inside unit electrical lines were hooked up backwards at the compressor. The compressor would pump too often and overcool the inside unit, because it was using the wrong temperature sensor. But you could have a ... LG LS-L1210CL Mini Split Air Conditioner

Air conditioner Model MSH-RV18 when using the remote to switch on and select heat the air conditioner expels cool air not hot air. But when I select the emergency heat button, the air conditioner expels hot air Many Thanks Julie


Hello,Please, change the battery of the remote, if the problem continue, there is a reset button on your remote, reset the remote.If the problem continues, then, your remote sensor receiver on the ac unit is bad, you \015\012 ... Mitsubishi Air Conditioners

My son has a Goodman Manufacturer Corp Heat Pump/air conditioner. Forced air I believe. The air conditioner quit. A repairman indicated that in order to replace the air conditioner the furnace will have to be replaced also. The air conditioner unit outside is Model No. CPE30-1-AB. Any thoughts?


I don't see any reason to change the furnace unless it's an air handler and not a furnace with a coil on top or bottom. And then, the only reason to change the inside unit when you change the outside unit is because it's a R-22 system and your going ... Goodman CKL30AR30 Air Conditioner

We have a Goodman Furnace and Air Conditioner approx 7 years old. When I put the Cool on thermostat and lowered the temperature for the air conditioner to come on the furnace fan started but the outside air conditioner only made a humminging sound. How long does it take for the air conditioner to start? I thought in previous years it came on quickly. I changed batteries in thermostat and reset the brakers on the main electrical panel. Could you please give me some advice. Thank you.


Hi, You are right. The outside unit starts quickly. The humming will either be the evaporator fan or the AC compressor itself. If you can reach into the evaporater fan with something narrow and stiff you may be able to see if the fan turns. Sor ... Air Conditioners

Hi, My remote won't work for my air conditioner. Batteries changed. Can't tell if it's just remote or air conditioner unit as well that aren't functioning. Can you tell me if there is a manual way of operating the airconditioner without the remote? If it is the air conditioner, what do I try to get it to work? I have taken filters out and cleaned them and that's all the ideas I had. My air conditioner is a LG Model LST 244H-2 split system. At least 6 years old. thanks for your help


Here is the main ONLINE SUPPORT page for your LG model LST 244H-2: ... LG Air Conditioners

Air conditioner LG SPLIT AIR CONDITIONER LSA18U1RPL1 AA32DRA IS NOT RESPONDING FOR REMOTE AND THERE IS NO DISPLAY IN THE AIR CONDITIONER ALSO.IF WE PRESS MANUALLY IN THE AIR CONDITIONER ALSO THERE IS NO RESPONSE.PL TELL THE REMEDY. THANKS


... LG Air Conditioners

I have a model AR DL10 remote for a Fujitsu air conditioner. The air conditioner's model is AOU18C1. The air conditioner wont respond to the remote after I changed the batteries. How can I fix this or at least find me a cheap replacement. Im currently using the manual button behind the air conditioner's cover.


After changing the batteries you have to depress the RST button and if the remote has the abcd slide switch ensure it is set to A. ... Fujitsu 18C1 Air Conditioner

Bryant air conditioner - outside unit will not run - before it quit running, air temperature in house rose from 65 degrees to 75 degrees. Inside fan continued to blow - air smelled like a car air conditioner that ran out of Freon. Bought Freon - need to know where to add it. The heat pump model # BF-163S bi directional but also coming from unit is another line that runs same direction with same type of valves. Air conditioner model # 697CN030 - B


... Air Conditioners

How do I know if compressor of my house air conditioner is turning on when I start my air conditioner? When I start my air conditioner the fan outside the house turns on, the air is blowing from the vents in the house but the air is not cold at all.


If the compressor is starting there will be a very small dimming in the house lights,if you go outside to the unit and start it from the outside disconnect when the compressor starts you will hear a whine type noise coming from the outside condenser ... Air Conditioners

We are selling our house and have been leaving the air conditioner on for the last several days at 70. It has been keeping the house cool for visitors when we are at work. Yesterday I came home from work and the house was warm. I checked the air conditioner and it felt like it was blowing just air. Checked it throughout the night and still blowing just air, not cold anymore. I am thinking it ran out of coolant. I am not an expert or know anything about air conditioners. If you could give me your


It can be many things like a loose connection. It can be low of refrigerant or it can be the condenser fan has stopped working. Considering you are selling the house just call a qualified HVAC repairman and have it repaired. ... Air Conditioners

My portable air conditioner is running, it seems like the compressor comes on, but the temp in the room does not decline and the air from the air conditioner is not cool. I purchased this air conditioner 7/1/06 so it is still under warranty.


A few basic principles for air conditioner troubleshooting. For both central home air conditioner or window air conditioner,\015\012 the first thing to check is whether the unit is getting proper power. \015\012If the unit ... Maytag M6P09S2B Portable Air Conditioner

We have a fujitsu reverse cycle air conditioner. Last night when we went to turn it off with the remote it did not respond. We needed to turn it off at the switch outside the house. We replaced the batteries in the remote. We get a display on the remote but it does not appear to communicate with the air conditioner. The air conditioner continued to send out warm air when we swithed it back on from the outside. We then found a manual on / off button under the inside flap of the wall mounted sys


Check if the remote control if still good, using the camera of your cellphone point remote control to the cellphone camera and press the "on" button of your remote and you can see the light emitting from your remote control transmitter. If the lights ... Fujitsu Air Conditioners

I have a new motorhome and the air conditioner only reduces the inside air temperature by 2 degrees on a hot day. e.g. outside air temp 26 degrees inside temp 29 degrees. After 2 hours of a/c running with door and windows shut inside air temp is 27 degrees. Dealer says the air conditioner is ok as air coming out of ducts is 3 degrees as required. I believe a larger a/c is required.


Can you tell me what size/make of motorhome you have? Certainly doesn"t sound right to me, and I've been working on them for over 15yrs. Whether it's a 13,500 BTU or 15,000 BTU, it should be plenty as long as motorhome has any insulation at all. I a ... Dometic Rooftop RV Air Conditioner

Air handler Is a 3 1/2 ton air handler too big for a 2 1/2 ton air conditioner? air conditioner FT3BA 030KA air handler B3BV 042k BB Also duct work in garage has a gap bringing in air from garage.


Yes and that's dangerous as fumes and exhaust may enter the house ... Air Conditioners

I need replacement parts for the Amana Comfort Zone Air Conditioner. I need the plastic exhaust vents that exist on the front of the air conditioner. If your are looking at the air conditioner, they are the vents on the right side.


... Amana Comfort Zone 12M32PBEH Air Conditioner

My air conditioner will not turn on. (See below for a more detailed description.) I recently bought a used Kenmore Room Air Conditioner Model 580. 76129. It worked well for about a month (running almost continuously, usually on either energy saver or cool). About a week ago, I walked out of my room when the air conditioner was on, and it was off when I walked back in about an hour later. (The display was unlit, and it was not making noise.) The power button still does not work. The outlet


If you have a GFCI plug on A/C unit it may need to be reset at the plug. ... Kenmore 76129 Air Conditioner

Hello - I have a heater/air conditioner; when I run the air conditioner it blows water and leaks water into the house. I was told by an air conditioner technician that I need to replace the unit; however it blows super cold air the only issue is that it leaks water. Not sure what I can do? It is a Fredrich Twintemp Model#EL25J35-A Cooling BTU/AR 24600/24000


When the filters, or heat exchanging coil, are dirty or blocked, this causes a restriction in air flow. This in turn can then cause the temperature of the coil to drop. If the coil temperature drops below zero, moisture in the air that is ... Friedrich Air Conditioners

Installing an 24,000btu air conditioner. The original wiring at that outlet has an double pole 20amp circuit breaker. The old air conditioner that was their was plug into an outlet box that sat on the face of the wall that had 30 and 250 on it. I had purchased an outlet that had 20 and 250 on it. The instruction for the wiring of the new air conditioner said 208/230 volts; 0 to 12amps; 20amp time delay fuse or circuit breaker. So tell me if I am doing the right thing with that 20amp and 250 volt


Yes your ok if they say the unit doesn't need to be changed in the incomimg power from 208 up to 230 volts or vice-versa,normally they classify motors as120/208/ 230 /460 volts, instead of 120/240/480 volts,but all line voltage varies in this voltage ... ACE -Air 24,000BTU Heat Pump A/C Free DVD Install it yourself Air Conditioner

We purchased a Whirlpool portable air conditioner in 2005 from Best Buy. Near the end of last summer the air conditioner started leaking water. We started using it again this season and it is still leaking. When my husband drained the water out of it, the water came out of the upper part of the back side of the air conditioner and no water was coming out of the drain at the bottom. When it appeared to be empty, we plugged it in and used it again and it continued to leak water on our carpet.


Check to see if the drain is blocked by particles/debris of any type. Also make sure that the unit is level--as level as possible. I have my Whirlpool Portable AC in 4 inch bed risers so I can drain it really easily. I slip under a small low rise p ... Whirlpool Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0867 seconds