12AJB42AO1 WEATHERKING MODEL12AJB4LAO1 208 1PH DRAWING APROXIMATELY 6.5 KW, IS THIS A 3 TON UNIT OR WHAT AND WHAT KW IS EXPECTED TO RUN THE UNIT


Answers :

Hi, \015\012 Check the mod # again. They don't have a 4L. If it is a 12AJB42AO1 it is 3.5 ton, If it is 12AJB48AO1, Its 4 ton. Not sure of the KW but it should have the Amp draw listed on the name plate although it probably wont draw that much. If you want to see if it has a proper charge in it, the suction line should be sweating all the way to the compressor but the compressor should stay pretty dry. If no sweat back or if its froze, its probably low, If compressor is all wet, Its overcharged. Hope I have helped. If not, please go into more detail on what you need.\015\012kstfas

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

12AJB42AO1 WEATHERKING MODEL12AJB4LAO1 208 1PH DRAWING APROXIMATELY 6.5 KW, IS THIS A 3 TON UNIT OR WHAT AND WHAT KW IS EXPECTED TO RUN THE UNIT


Hi, \015\012 Check the mod # again. They don't have a 4L. If it is a 12AJB42AO1 it is 3.5 ton, If it is 12AJB48AO1, Its 4 ton. Not sure of the KW but it should have the Amp draw listed on the name plate although it probably wont draw that much. If yo ... Weather King 10AJA6001AH Air Conditioner

Hello, I have goodman 3 ton a/c that runs ok for about a half hour or so then the condenser stops running because the circuit breaker pops off. The a/c tech check the units draw ( 13 amps) and thought it was ok. We thought then it was a faulty breaker. We then put a new breaker (30 amp). Later same result. a/c works ok then trips breaker. Wait awhile then reset breaker and it runs again. What would cause the breaker to trip like that. Any ideas? Thanks


First of all, let me caution you to remove the 30 amp breaker and put back the 20 that was there. It's not to code. It's too big for the wire size. Second, you will need to monitor the circuit with a 'clamp on' amp meter to verify the current d ... Goodman CKL36AR36 Air Conditioner

Hi, we have a problem with our Weatherking heating unit/ air conditioner. We had it installed 07/20/06. It really never has worked properly. For the last 2 summers in run's constantly. Which of course makes our electric bills outragous. Our house is around about 2200 square feet. This unit is a 4 ton unit. What could be the problem. Please help. Thank you. The model # is 13AJA48A01


Lets look at the whole problem. Did you have a new unit inside. Is the charge correct for unit. 1 lb of refrigerant makes difference. Four tons should be big enough if you have proper insulation. I have three tons in a 2100 square foot house. Its ple ... Weather King 12AJA4801AH Air Conditioner

Brand new unit have 3 ton inside and out but unit runs all day and will not hold temp i run my ac on 76 but as the day get hot the temp inside will not hold at 76 ARS says they dont know whats wrong but they installed the unit said i would have lower light bill but unit runs all day light bill 900 can someone help please with a solution


Call them back something is wrong if it is that new it is likely under charged. how big is your house square feet and what part of the country down south 400 square feet per ton if your house is more than 1250 square feet the unit is under sized ... Weather King 10AJA3601AH Air Conditioner

This is for a Friedrich QStar SQ06J10 AC unit - When switch is normally shifted to the 'cool' position ('on' mode), it seems to not complete the circuit. Jiggling or pressing hard on the switch will make the unit run, but one has to hold the switch. Can a DIY-approach fix the connection, so the unit will run as expected? or does the switch panel need to be replaced? Relatedly, might it be 'better' to simply swap out this unit for a newer, possibly more-efficient unit?


... Friedrich QStar SQ06J10 Air Conditioner

I have a 1993 Model SRHF48U01A (The 0 might be a O (zero) When the thermostat calls for cooling, the inside unit (fan) starts up and continues to run but the outside unit wants to start (it comes on for a second and then trips the breaker that is located behind the outside unit. I can turn the breakers off that are inside the house and let them stay off for a short time and then reset the outside breaker and then turn the inside breakers on and the unit starts and continues to run until the te


Well the trouble is surely at the compressor side. Dont know what kind of repair man you invited. He should have atleast diagnosed the problem. Following can be the causes\015\012\015\0121. Capacitor is slightly faulty (As you said). If t ... Amana Air Conditioners

Earlier this week, I noticed that the house felt "stuffy" but the thermostat showed everything to be cooling as expected. Last night, the house was definitely warmer than expected when we got home. My husband did some checking and found that the outside unit was running as normal, but there was no cool air coming through the vents inside the house. turning the a/c unit off at the thermostat did NOT turn off the outside unit...was only able to do this at the circuit breaker. It seems that the fan


If both fans runs (inside and outside), check if the compresor runs , if does probably the unit is low in freon and needs to be recharged after the freon leak has been fixed (remember this is a seal system and it shouldn't leak), but if the compresso ... Ruud UBHC Air Conditioner

I recently bought a 4 ton 14.5 SEER Rudd Spilt system using R-410 and matching Rudd furnace. This system replaced a Lennox 10 SEER 4 ton unit. Now that it has gotten hot in Baton Rouge LA 90-93 degrees. I have a programmable thermostat see bottom. It takes the one hour to drop the temp. 1 degree so starting at 5:00pm the unit runs non stop until 11:30 at night. The Lennox was about 3 times better and it was 15 years old. The installer told me all high SEER units take longer to cool in comp


Sounds like the Unit might be low on charge.But without correct readings not sure.\015\012The new unit with 410 will actually cool better due to higher boiling point temp. of freon type.Poor air circulation could also cause problem.Such as dirt ... Air Conditioners

Earlier this week, I noticed that the house felt "stuffy" but the thermostat showed everything to be cooling as expected. Last night, the house was definitely warmer than expected when we got home. My husband did some checking and found that the outside unit was running as normal, but there was no cool air coming through the vents inside the house. turning the a/c unit off at the thermostat did NOT turn off the outside unit...was only able to do this at the circuit breaker. It seems that the fan


Nope, nope, sounds like a stuck contactor in the electrical compartment of the condenser, but there are actually several things that could cause it. ... Air Conditioners

We had a new American standard furnace and A/c unit installed. A 2 ton compressor and a 2 and a half ton A coil. The unit is not cooling the charge was checked and it is ok. Unit is on and blower working and in cooling mode. At start up it was producing 49 degree air at the coil now it is running 68?


Make sure orfice used was for two ton unit and correct refridgerant also make sure that the elect auk heat is not pulled in check the psi on out door unit should be close to 225 hi side and 70 suction if heat pump switch the reversing valve man by o ... Air Conditioners

I have a Rheem heat pump/air handler; it draws 2.9amps with only the fan running, 13amps when the heat pump is running and 38amps with the heat strips on. My question is why the unit draws that many amps when in heat pump mode? Isn't all of the work being done by the compressor outside?


You gave us some good clues, and figures to work with-- THANKS!!To answer your question: Your unit switches the one compressor, from cooling, to heating, by reversing some valves-- Same compressor-- just routing the refrigerant i ... Air Conditioners

I have a Duo Therm unit on the roof of our 1995 Nomad camper trailer. I think the contactors are stuck closed..here is why. When the AC unit satifies the thermistat, the fan turn off, but the compressor (Humming sound)keeps running...until I hit the AC 15 amp breaker. Even if I put the thermistat up passed the current temp, the compressor still keeps running. Where are the contactores / relays? Shal I take the cover off, and start looking around? I would expect a low voltage relay for the thermi


You can get a manual for this in the library section of the Hi-Lo Trailer Forum. I know this isn't a Hi-Lo but the AC unit is the same. www.HiLoTrailerForum.com ... Air Conditioners

Have 3.5 ton scroll compressor, single phase, that will not run. Checked start, run, common windings all ohmed ok. Checked for case ground/short, none detected. Replaced contactor and capacitor with new. Still will not run. Force contactor closed to energize leads to comp and voltage is there, but comp will not kick off. Checked amp draw on incoming line is 4.5 due to only condenser fan running. If comp was locked amps would be very high and if internal wiring were shorted it would show open


Hi!!\015\012\015\012\015\012Wire your compressor the following way, run new wires if needed, forget about bypassing sensors, check electrical terminals to be tight and clean.\015\012\015\0121. Have L1 going straight to t ... Air Conditioners

I have a Carrier Synergy 2000 38tda048300 4 ton/2 ton unit it is a 2 speed unit. It is 8 and a half years old. The unit keeps running on the inside but the fan stops and the outside unit stops. Seems to be the same time daily. AC man came and said it was the compressor. We got a new compressor. The very next day it did the same thing. The only way to make it start again is to flip the switch leave it off for 15 or so min and restart. This was exactly what happened prior to replacing the


... Carrier Air Conditioners

Weatherking 3 ton Run Capacitor


Could be; age,lightning,power surge,defective wire,loose wire,tight compressor. Capacitors fail sooner or later. They are like batteries they do not last for ever. ... Weather King Air Conditioners

Outside unit is running however it is not cooling.I cut off the circuit breaker wait 20 or so minutes and turn it back on and the unit works perfect for a while (no set amount of time ranges from hours to days) any ideas?It is a new unit and did the same thing when it was turned on for the first time.Worked 2 weeks before starting again.Unit is a little low on freon.It is a Goodman 3.5 ton ac only(gas furnace)


Sounds like there is a Freon leak and has been since it was installed and is going off on because of low charge, you will need to call a competent A/C repairer, more then likely the leak will be in the air handler, should cost under a $100 to fix. Go ... Goodman CKL42AR42 Air Conditioner

I have a blown BDP 7.5 ton Condsor unit. The old unit is R22. I want to replace it with a new BDP which has R410A. Question: I am being told that If I flush my old R22 Air Handler Coil & install a TXC valve. I can run the new R410A unit on the old handler. Is This True ?


I've done what you are describing - "however" you could void the warranty on the new condenser - by not having 'matching' coils (inside/outside). I would do some serious checking with whoever you are buying the new condenser from. \015\012\01 ... Air Conditioners

I have a Tane 2 ton condenser unit that has high head pressure(290) and high suction pressure(150). The unit is properly sized but no cooling. Unit has been installed probably 4-5 years and has not been run for over a year.


Has anyone added some freon? The unit has way too much freon inside it. You need someone to reclaim the freon and weigh in the right amount of freon. If you run the unit the way it is will cause some very serious damage. Let me know ken ... Air Conditioners

I have a Goodman 3.5 ton, CKL42-1 outside unit. It was not cooling properly so I cleaned the fins because the were quite dirty. When I turn the system on it will run fine for about 20 minutes and then the fan will stop running but the consenser continues to run and it makes a horrible loud sound. Any ideas?


How did you clean the fins if you powerwashed the chances are you bent all the fins over so the fan cannot pull in air and is shutting of on overload when it cools down it will come back on then heat up and shutoff again ... Air Conditioners

Home unit 3 ton won't run


The small capacitor is for the fan motor the other for thecompresor .You can try conecting a booster (or hot start) in paralel to the comp.capacitor .If this doesnt work you have to replace the compresor. ... Air Conditioners

What wire size do I run for a 3 1/2 ton AC unit?


It depends on the distance from main power source # 8 if more than 40 feet look at starting amps then google a wire sizing voltage droop chart ... Air Conditioners

Need to purchase the wire and breaker switch for a Hitachi A/C Unit 30 ton unit. RUA-30HS. I need the tecnical specifications for this installation do you have them. Or can you help me with three questions: Starting Voltage and load? Average Running voltage? Recommended size of Breaker Switches? The Amperage is 3 phase so what size of cable is required? Thank you so much for your help.


Get an electrician you trust in your area. He will need probably need to physicially look at the unit. Then he can answer all your questions on this matter ... Air Conditioners

I have a Carrier 38tra048340 ac 4 ton unit outside, heater in attic. Thermostat is Totaline P374-1100. Power went out than back on after a few hours due to vehicle crashing into power pole. AC was running at time of power outage. Power came back on, ac would not come back on. Checked house circuit breakers, none tripped off. Turn ac 40amp breaker and heater 20amp breaker off and back on. Voltage ok. Checked fuse box by ac unit on wall, fuses and voltage ok. Went into hot attic to check for powe


Blank screen sounds like a fried thermosat. Abrupt outages can affect certain types of thermostats. Make a jumper wire and jump across R and G. See if you get any action from anywhere. If a fan or compressor kicks in you know you have a burned out th ... Carrier Air Conditioners

I have a RUDD AC 5 ton and the inside unit is running and blowing but the air is not cooling and the outside unit is not turning on. I checked all the breakers and tried pressing the reset button on the bottom. Is there a trick to pressing that button....nothing seems to be happening...do I need to hold it down for a certain amount of time? Thanks! It is getting hot in here....


Is the contacror pulled in? If not check the low voltage to see why it isn't, if it is, check for voltage out the other side with a meter. ... Ruud UBHC Air Conditioner

I am trying to get an electrical schematic of my RUUD 3.5 Ton condensing unit UAKA-042JAZ. The one that is attached to the inside of the unit's cover is not readable. Where can I get another drawing to follow? Thanks.


Thers 2 sides of power in the entire unit besides the 24 volt control wires! what are you trying to make run? theres a fan and compressor, both operated off the same contactor!! ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1166 seconds