Having problems with your Air Conditioners ?

When turned on, lights come on, but will not blow...

\015 I just installed a used Whirlpool ACQ122XK airconditioner, that has been stored for about a year. Anyways, I turned the unit on before I inserted it into its housing unit and it worked just fine. Then I inserted it into the housing unit and ran it for about 10 minutes and it ran fine, but the front radiator looking piece was sort of grimy, so I turned it off and vacuumed it, even though the bottom of it was sort of wet. I did not bend any of the aluminum pieces or anything, but now it won't turn on. When I turn the unit on, the lights come on and it sounds like it is going to start blowing, but then it clicks, behind the "power square" with the on/off switch and the cool/fan speeds, and the blower turns back off. Then about 30 seconds-1 minute, it clicks again, like if the blower is going to come back on, but then it clicks again and turns off. I have tried to unplug it and let it set for 3-5 minutes and try it again, but it does the same thing over. Do I need a new unit or is this a minor problem that can be fixed? Or even a solution, that I can possibly try, that might make it work? Thank you for any help that I can get!!!\015

Answers :

First off, I dont think you caused this problem by vacuuming the unit. It is possible that you did not leave much time before restarts but you then said you tried leaving it off for 5 minutes which should be adequate enough. f you let the unit set for a couple of hours before a restart that should be enough time for the compressor to cool down to ambient temp. I would then try restarting the unit, if it works leave it on for a while and make sure it is producing enough cooling. If there is no change in the situation I would suggest that it would need to come back out of the housing and check that the compressor is receiving voltage to it. It is possible a start capacitor or relay is the cause of the problem. If it started first time I would suggest it is worth having it checked by a professional as it could be the charge or the starting devices. First off though let it completely cool down and try again. Hope this is of some help.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Water tank full light keeps coming on an shuts the AC off after about 10 minutes on a Amcor A12000E Nanomax Portable Air Conditioner. I drained all the water out of it I could and it does turn back on after I turn it back on and will run for about 10 minutes. Then it beeps 6 or 7 times and the water full light comes back on and shuts it off. There is no more water coming out of it and there is a buzzing when it comes back on but it will blow cold air until it shuts off again. Please help!


Dod u get any help with your problem because i am having the same problem and ofcource the company is no longer around ... Amcor A12000E Nanomax Portable Air Conditioner

When turned on, lights come on, but will not blow...


First off, I dont think you caused this problem by vacuuming the unit. It is possible that you did not leave much time before restarts but you then said you tried leaving it off for 5 minutes which should be adequate enough. f you let the unit set fo ... Air Conditioners

I have an air conditioner Appliance AAC 1100 A-PTC that wos working for two days and now its not cooling or heating:-( Both outer and inner parts of the machine seems to be running but it wont heat or cool the room. When i try to turn it on there is a red symbol that lights up on the display (defrosting) this light goes off every 5 minutes or so,then the machine starts to blow air (not heated or cooled) for aprox 20 seconds then the red light comes on again and this procedure starts over again.


... Air Conditioners

E6 error I have a new Friedrich split A/C unit (ten days old). Just ran it for the first time and after a couple of minutes, E6 shows up on the display panel on the wall mounted unit. After some detecting, I discovered that the unit outside never comes on. The wall unit does blow but it seems to just be blowing air (yes, I have the remote set to "snowflake"...but the "snowflake" light on the display panel also turns off after the initial couple of minutes. I HOPE the problem is not in the wall (


... Air Conditioners

Every time my heat pump turns on, the blue auxilliary light comes on, and it only blows icy air. I do not want to use that much power, so I turn it back down a few degrees. Now, it is 50 degrees in the house. Tonight it will be around 16 degrees outside. How can I get my heat pump to produce warm air?


A heat pump starts losing efficiency below 30F or so. The aux. heat helps the heat pump keep up with heat demand. The Aux heat can be electric heat strips or another type of heat. Check to make sure you have power to whatever type of aux heat you hav ... Amana PTH123B25AJ Heat Pump Air Conditioner

I have an older Carrier Gas Furnace. I can't read the complete Model number. But since Thursday morning, the blower just keeps blowing cold air, the spark igniter won't spark and the air damper will not open. I replaced the spark igniter and the pilot assembly for $215 and the thing still just won't light. As soon as you turn on the power the blower comes on and just runs. I check my 24v supplies from the transformer, and I am getting voltage. What else could it be. There are no LED's on the PCB


Nothing will happen until the draft motor come on or the vent damper opens.  if that's happening, are you getting gas? ... Air Conditioners

Everstar MPA-08CR. The unit is blowing air, but the cool and dry functions are not working. The green light that indicates that the compressor is on (which normally comes on and stays on in the cool and dry function) blinks and then turns off. I can?t find my manual and do not know who to call for help. I understand that this is a generic model sold under different names. I bought mine at Home Depot. What should I do? How do I fix it? Who do I call?


Hi,from your problem it can be deduced that the problem is from the starter relay attached to the compressor which supplies power to the compressor.it's probably weak or bad hence the light that stays on in the cool and dry function blinks as a resul ... Air Conditioners

No Air My unit unit display light up showing a temp of 30, but nothing else come on, no fan, nothing turn at all or blow any air.


30 is too low. Raise the thermosta to 74 and see what happens ... GE Built-In Room Air Heat Cool Air Conditioner

My Mr Slim Model # MSH09TW suddenly is turn off in the middle of the night. Then comes back on for 5 minutes, then stop and blows nothing( with the green light on). I've had the HVAC people service the unit, tested and did a setback, replaced the batteries in the controller and the problem still exists! What needs to be done?


It sounds like the thermal overload it kicking it out. The thermal overload is to keep it from starting a fire. Something is getting hot inside the unit. ... Mitsubishi MSH09TW Air Conditioner

The power light is on, but the ac doens't turn on and doens't blow out air, it looks like its attempting to come on but its struggles. tried different power outlets still nothing.


First check for correct voltage at the wall\012Then remove the capacitor and take it to an appliance parts store .\012They will check it\012Be careful. The capacitor holds a charge even after it is removed.\012\012If thi ... Air Conditioners

I'm renting an apartment with what appears to be an old...very old furnace. I've gone to the leasing office and nobody has come to look at it yet and it's been nearly 3 days without heat in my place. So here's the problem. I lit the burner as it must have been out the whole summer. I figured lighting the burner would give me heat but no luck. When looking at the furnance there's a chain pulley on the left with a low/high speed. When I pull the chain the motor/fan turns on but blows cold/cool air


I got a solution.don't mess with it.\015\012just harrass the landlord till you get service.it's against the law not to provide you with heat.be patient though....we are coming off the holidays.any people are just returning to work.that includes ... Weather King 12AJA6001AH Air Conditioner

I have a Mitsubishi Mr Slim PK36FK3 and i get error 8 on the codes. I have cleaned the filters and checked to see there is nothing blocking the condenser fans. The fuses do not blow and the breaker does not trip. The unit stops and the green power light flashes with error P8. I can turn it off and on again and it will run for a while. Then the same error messages comes up. What is the problem????


Hi\015\012\015\012There are many things that can trigger that code. The most likely is a power problem...ie. Outage. Reset, and Recycle the power off and on and it take off and run.Other things to check are:1 Wrong wiring of I ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

Unit is a Samsung AS09A1VE Air conditioner Split System Unit turns on with remote, green light comes on with start bells. Another bell sounds yellow light comes on, unit switches off green and yellow lights start flashing, all in around 5 to 10 seconds, unit will turn off with remote, lights go out. I reset the unit by disconnecting power and reconnecting. Unit worked fine for several hours after that (although it did discharge some some small black debris. It then repeated the same proble


Hi,\015\012This sounds like a problem with it either being too cold outside or the unit is low in charge. What happens then is that the indoor coil getts too cold and the unit will shut down before is freezes over.\015\012The cold outside ... Air Conditioners

My goodman furnace (model gmp 108-3) is not working. If I turn off the unit and turn it back on the fan comes on and the little filament heats up, then the top burner will light, but it will not stay lit and none of the other burners will light. After a few tries, it turns off and doesn't come back on.


All of the burners should light. Could be a dirty flame runner. I recommend that you get a good clean and check.. Burners, flame runner, flame sensor should all be cleaned. If this does not solve your problem than the gas pressure nee ... Air Conditioners

The air conditioning will blow cold and then it blows hot and the a/c light blinks. i can turn it off and wait 5 minutes and turn it back on and it will work and then blow hot and a/c light blinks


Sound like you have one or 2 problems,, one the hight pressure switch may be bad,, or the compressor may be going out,, good luck ... Air Conditioners

Have NEC RIH-2667 Inverter Split system.I set to Heating mode,set temp to 25 degrees.The compressor light comes on.The run light flashes for about 30 seconds.Then the vent opens,the fan comes on and starts blowing out heat.Within 5-10 mins the temp on split displays starts going up.when it gets to 26-27 the run light flashs,fan stops,no heat coming out.The temp on system keeps going up to 30 degrees.it takes approx 40-60 mins to come down to 25ish the will come on again and repeat.I have an inde


... Air Conditioners

I am trying to find information on re-lighting my pilot light on my honeywell day and night furnace. I see switch for blower is off, pilot dial is on "pilot". Blowers not active and pilot light not lit. I think I just need to turn pilot dial to off to reset and leave for 5 minutes and turn back to "pilot" and re-light, before turning everything back on. I'm not sure where the gas is coming out of. Is it right above the dial. I have long matches to use. Please let me know. Thanks for you


Without knowing exactly who the manufacturer is and the model number of the furnace, most of us really don't want to reply to this question, for fear of you blowing yourself up. So, if you can provide that information, I'm sure one us can help you. ... Air Conditioners

My panasonic air conditioner system keeps turning itself off and the timer light comes on flashing. The remote hasn't had the timer set. I have tried reseting the unit via the remote controll however it comes on for a split second and then turns back off again with the timer light flashing again. Can you please help?


... Air Conditioners

My fridgedaire window unit A/C and heat won't come on. I had replaced an outside light fixture a couple of weeks ago and had turned off the circuit breaker that affected this unit too. Now the unit won't come on AT ALL. I've unplugged the unit, then flipped breaker off then on again. Then plugged back in and hit "Reset" Button on the plug, then waited at least 3 min. as instructed, but still no power. The light on the plug doesn't even come on when I hit the test button. Could it be a faulty cor


Plug a light into the outlet used for the A/C, if the light does not come on when reset then the circuit breaker that provided the power to the outlet need to be reset or replaced. ... Frigidaire FAS257S2A WallWindow Air Conditioner

RUDD Silhoette 2 model UGLH-10EBRJR ignitor won't ignite (glow). Exhaust fan comes on for about 30 sec. then the thing clicks, a small amount of gas emits then turns off, then the circulating fan comes in and runs cold for a while. I can light it manually 9with a lighter) and it runs OK until the house reaches temp but then, of course, it won't come back on unless I light it manually.


... Air Conditioners

Last night my husband turned off our window unit because it had gotten cold in the house, we got up this morning and went to turn the unit on and it won't come on at all. The light on the plug is on and when I click the reset button it lights up everything on the front panel but it turns itself back off. We always have to replace window units every year and this is quite costly and am getting tired of this. We have 3 other units that are older than this one which is only a year old but we also p


Must be a shorted capacitor. ... Air Conditioners

We had a terrible thunderstorm and I saw a flash of light near our transformer. All the lights in our house dimmed. Since this had happened before and we damaged our capacitor, I immediately turned the AC unit off(Amana Prestige II). When the power stabilized I turned the unit back on but the compressor will not come on. I tried turning the breakers off and on but it did not work.


Well, that;s not good. whenever there are thunder and lightning around, you should always UNPLUG, to disconnect EVERYTHING from the wall, simply turning OFF, is NOT sufficient. \015\012I would expect that the induced current from the lightning, will ... Amana Air Conditioners

MY frigidaire Air Conditioner model number: FAC107P1A2 has suddenly stopped blowing cool air. Check Filter light comes on but filter clean. Press Check Filter light button and blows out cool air for about a minute then blows hot air. Bought new at Lowes. Never had problem before with this air conditioner for 6 years! Please help burning up!


A few basic principles for air conditioner troubleshooting. For both central home air conditioner or window air conditioner,\015\012 the first thing to check is whether the unit is getting proper power. \015\012If the unit ... Frigidaire FAC107P1A Wall/Window Air Conditioner

My central heater is not blowing hot air, I am having to turn the thermostat on and off. I have the thermostat to 70, and the heater will blow hot air and then it will just circulate the air in the house, therefore bringing the temperature down. I looked at the unit and noticed that when the thermocople (heating element) goes red, the gas valve makes clicking and the flames come and then go out very fast. I noticed lots of clicking in coming from the gas valve. help please


Hi!!! relax your flame sensor is bad change and you will be fine..If it turns off and on change your flame sensor ... Air Conditioners

Fujitsu asu15rlq just installed timer light flashes twice every 10 seconds. Inside unit fan comes on outside unit does not come on. Timer light keeps flashing when inside unit is turned off . Please help


... Air Conditioners

A detailed question is important to get you a relevant answers