Low discharge super heat

\015 Carrier 19 xr evergreen I had too rebuild this chiller and after complete i had this problem from the get go.I know the charge is correct I changed the screen on the float and running out of things too do i also lowered the flow on the condensor side just nothing working.\015

Answers :

Hi, Its been a long time since I have worked on one but maybe the chilled water is having problems and not circulating good. Could be airlocked somewhere if its been down for a while. Hope I have helped.\015\012kstfas
Try to shor tcirquit the flow swich/

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Low discharge super heat


Hi, Its been a long time since I have worked on one but maybe the chilled water is having problems and not circulating good. Could be airlocked somewhere if its been down for a while. Hope I have helped.\015\012kstfas ... Air Conditioners

Hi, there is a Ductless LG Model # LA180CP that has freez up problem. Sometimes it freez up after 3 days working and some times after couple of hours working. Freez up start from indoor unit. Average of super heat is 10, but it is changing all time between 6-15. suction line Temp 45F, Discharge 53F, On Gage 35F, Supply Air Temp 8.2C and Return Air Temp is 22C. What do you think about this issue? THanks


What refig and where are the pressures. freeze up is always low charge or lack of air flow and always occurs at the evap. Once it starts and you loose surface area you have to defrost manually ... Air Conditioners

100 Ton Chiller With EXV. Controls Triping On Low Suction Super Heat


... Air Conditioners

High suction press (98psi), normal head press (140psi); full sight glass;low super heat (10 degrees);normal subcooling (13 degrees) new txv, new evaporator, new condensing unit 70 degree air from vents no breaks in return air duct 100 ambient have tried another txv and still same problem; good valves in compressor


Lower fan speed.....and double check head pressure, sounds very low!!! should be around 250-275.....also make sure the return air grill is large enough. ... Goodman CLQ36AR49 Air Conditioner

This is a heating and cooling through the wall heat pump. It works normally when heating is selected - the heat pump runs and both speeds of the fan blow warm air. But nothing runs when cooling is selected. In other words the unit works normally when "High Heat" or "Low Heat" is selected but nothing runs when "High Cool", "Low Cool" or "Fan Only" is selected. The position of the Fan Cycle Switch has no effect - behavior of the unit is the same in both positions of the Fan Cycle Switch.


You have a bad board or bad switch. I would say board. You can have service tech check this out. There is only so far you can go without knowledge of Controls ad electricity. Russ ... Air Conditioners

Zoneline AZ28E15DABM1 indoor fan works on heat hi ,low ,air hi,low and fan ,hi ,low , when on heat or ac the compressor or heating element comes on for a few seconds then goes off , fan kepts running . I think its a switch on the main circut board but not sure ?


... GE Zoneline AZ25E12D3B Air Conditioner

I have a 6 year old Carrier Performance 38yza. Having a problem with heat. First no heat at all heat pump or AUX. Found AUX heat strip were grounded out and have now been replaced. Second no heat pump, Compressor comes on for only 1 to 2 minutes then shuts down. Service call yesterday Tech says no signal from Carrier Programable T-Stat, jumper heat pump, low freon adds. Says T-stat bad, but puts back together. Heat pump works blowing 90 plus degree from vent works great all afternoon and into ni


This sounds like you have a freon leak. Most units never lose freon. So that is one problem that needs to be addressed. Here is some more solutions for you: Other things that will cause or aggravate\015\012ice are clogged filters, bad fan moto ... Air Conditioners

Central heat pump unit isnt keeping house warm and runs all night long - low temp has been in teens last few nights - noticed the outside unit is making a constant noise like whump-whump-whump - is it low on freon? should i switch it over to emergency heat only? any ideas what might be wrong?


Hi,Is it a Compressor that is making Noise? If yes, this is a Bad News. More often you need to Replace the Compressor.Usually when it comes to Warm air, usually that shows that AC is low on Freon.On Both Cases, yo ... Air Conditioners

Reversing valve Model: PHJ030-1A Seral: 9705062008 The reversing valve is not reversing to heat. I found a small hole at the condenser coil, with oil residue around the "U" shape joint. When the heat stop, the condenser froze up. I think the a/c part will continue to cool with low pressure. Could low freon keep the reversing valve from switching. Reversing valve need more pressure to work. I check coil, the ohms is 17.6, and I do have 24 volts going to the coil, but I did not check it in cool fo


The first thing you need to do is fix the hole in the coil. It will only get worse no matter what you do. The reversing valve is controlled by the thermostat, then to the defrost board, as it has a timer, sensor ... Air Conditioners

Zoneline 2100 does not get very warm, it stays the same low warm temp in low heat or high heat and also turns on by itself after being swithched to stop position


... GE Zoneline AZ55H09D Air Conditioner

I have a Lennox model CB19-51-1P air handling unit with HP19-511-1P compressor heat pump unit. I just turned the heat on for the first time this season. And I am getting low heat volume. The heat pump unit is running for long periods. I am getting enough heat to maintain the 70 degrees setting with constant cycles, shutting off for short periods, running long periods. When the thermostat is turned to a cooler temperature, the unit shuts off as it should. Could you please help trouble shoot po


First thing you need to check is if the reversing valve is working you maybe running your A/C with the heat strips on depends on the t-stat your using some heat pumps will bring the strips on with a high d ... Air Conditioners

I am trouble shooting a Bryant Hi-bred system that uses an air cooled heat pump with high efficiency gas furnace for backup and low ambient operation. How does the system decide whether to use the air cooled heat pump or the gas fired high efficiency furnace. It appears to be outdoor air temperature related, but I can't find the setpoint for it. The main zone Bryant thermostat appears to control the system, but it doesn't always bring the backup heat if the heat pump doesn't function.


If you are using honeywell vision pro 8000 t-stat you need an outdoor sensor program on t-stat would have to look up ... Bryant Air Conditioners

Heat... On low or high heat, the unit only heats for a few minutes then blows only cold air even with the temp turned all the way to heat. The status light on the board shows ok. Any ideas what to look for?


It sounds like the thermostat bulb has moved or the unit is getting an immediate air recirculation due to a partial blockage or air diversion close to the unit causing the warm air to get back to the thermostat bulb too soon, heating only a very smal ... Amana PTC153B35AE Air Conditioner

Fugitsu ART45LUAK ducted airconditioning. To heat the house I set the fan low, heat manual and thermostat 24C, the temperature keeps creaping up to 27C. The you can hear the thermostat being reached but the heat comes on agin, then agin till its really hot. Same thing happens when using the cooling setting, but in opposing temp ie set to 24 will drop to 20. If the select temp and fan is set to auto, it will heat up too much and then will then auto cool down too much like its fighting itself.


... Fujitsu Air Conditioners

Amana PTH153B35AK This unit is less than 30 days old, heats fine cools fine, but when i have it in heat mode,set @ 70 or so, as soon as the room heats up, the unit will cycle into a/c mode and blow super cold air for about 5 minutes than return to heating. Sometimes it will reach the desired temp. and turn off like it is supposed to do, but for the most part it just cycles back and forth from hot to cold...Amana has the worse help/service i have ever seen, i was on the phone for an hour,everybod


This often happens if the unit is oversized or to close to a wall or object. ... Amana PTC153B35AK Air Conditioner

I have a Tempstar model NFCP3600A1 (style # FCP3600A) ICP Heat Pump. Starting last week, the unit kept heating well over the set temperature. I swapped out the thermostat thinking it went bad, but it still continued heating and the "off" wouldn't work at the new thermostat either. Next, I checked for shorts in the thermostat wires and they seemed OK. I then replaced the TI 26FC-2 circuit board. Once the unit heated the house to the set temp, it continued running up to 75 degrees. "Off" and lowe


... Air Conditioners

Low Volt wiring for a two stage heat pump as primary heat with a gas boiler as back up heat the out door unit has a sencor on it with a honeywell 8000 t stat


Ok?? what is the problem? ... Amana PTH123B25AJ Heat Pump Air Conditioner

Installed model 48203A876 s/n 061007181 ac in my enclosed trailer. added 9330A6151 heat strip converson kit. The kit came with a new thermostat, wiring diagrham, thermostat button and main control button that is the same as the one on the unit. Neither has low heat on it as an option. Is my original unit ready fot the heat strip or should I have to replace the thermostat, button, or anything?


... Coleman Mach III Air Conditioner

Goodman heat pump model CPKJ421B. Tripped breaker for outside unit two weeks ago. Reset breaker, tripped again today. Unit won't run now. Did some basic checks and found that the 28 vac from the inside unit was not going through the low pressure switch to pull in the 220 vac contacter for the compressor. Possibly either the refrigerant is low or the low pressure switch is bad. Could a faulty switch, maybe losing and regaining contact quickly, trip the breaker? Could the refrigerant, just before


... Goodman Air Conditioners

I have a pane heat pump during the summer it worked great but now the heat pump dont seem to be heating the temp on the suction line is 160 f out side air is 58 and in door temp is68 f . on my gauges the low side is 125 psi and my hi 135 psi. acording to the cover my hi side shold be over 300 psi. this is a puron 410.


Hi,Is the reversing valve sliding ok?sometimes they get sticky you can try taping it to free it into correct position to allow full heating mode. ... Air Conditioners

Goodman AC Unit with Heat Pump - Works great cooling when switched to heat the outside unit does not come on - inside comes on and uses emergency heat? What can I check? I first checked the contactor and it looks fine, the inside thermostat had low battery voltage...replaced batteries but still not working? Any help? Thanks


Because the outdoor unit works in cooling, it sounds as though the contactor and other components outside are working correctly. The problem sounds as though it might be somewhere in your thermostat. Has the thermostat been replaced recently? If so, ... Goodman CKL60AR60 Air Conditioner

I have a Carrier Weathermaker Infinity furnace model 58MVP100-F-1-20 with 3 zones and Carrier Comfort Zone II programable thermostat. I recently installed ageothermal heat pump system which includes a hot water coil in the furnace plennum. The heat pump is sized to meet loads except for the coldest days of winter - (below 0 F) - when the gas furnace is expected to kick in. My problem appears to be the Weathermaker's characteristics don't accommodate the low heat /slow response provided by


Http://www.hvac-talk.com/vbb/archive/index.php?t-85094.html here is a site i found very useful ... Carrier Air Conditioners

Heat pump shut off 1 to 2 minutes, service yesterday for same problem told low on freon. Added freon, worked fine until it went thorugh first defrost, now back to same thing. Tech says compressor not getting signal from thermostat. After resetting T-stat, unit came on. Unit works on cooling and Aux heat, but no heat pump.


It is possible that you have one or a combination of a few different problems here.If your heat pump will not come on but the air handler works, the first thing you want to check is that the circuit breaker and disconnect for the heat pum ... Carrier Air Conditioners

We have this air conditioner in our sunroom. From the beginning, the temperature set is not maintained. When the unit is set to cool, no matter how high a temperature I select, the unit cuts on approximately every 10-15 minutes, and cools the room to about 66 degrees. When set to heat in the winter, no matter how low a temperature I select, the heat cuts on about every 10-15 minutes, and the room will heat to a much higher temperature than selected. Any idea what the problem is, and how I ca


Change thermostat. ... Amana PTH153B50AM Air Conditioner

My comfortmaker heat pump blows the 5 amp low voltage fuse after a few minutes of heating time.


... Comfortmaker C4H436GKD 3 Ton 14 Seer R410A Heat Pump W/ Air Handler

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0541 seconds