Having problems with your Air Conditioners ?

Problem with this unit

\015 When I turn the unit off, the motor keeps "humming", also when on, the compressor runs continually. The coils are NOT iced up. Thanks for any help you can offer.\015

Answers :

The controll board for the unit is faulty. The contacts for the compressor are stuck closed.\015\012\015\012The humming is the compressor running when the unit is off.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a carrier 38ckc060370 that runs but the air is not cold coming out of the vents. i checked the copper line coming out of outdoor unit and is not cold either. does this mean that i need a recharge, or could there be some other problem? recently, i've had problems getting the unit to turn off, and had to use the breaker because it would not shut down on its own, but other than that, the unit has never had a problem. the unit is about 4 years old.


If the unit is not shutting down, then there is a chance the contactor has gotten stuck. This is not a good thing. If the contactor were to weld itself shut and the outdoor unit were to continue to run without the indoor fan running for an extended ... Carrier 38CKC060 Air Conditioner

I have a carrier 38ckc060370 that runs but the air is not cold coming out of the vents. i checked the copper line coming out of outdoor unit and is not cold either. does this mean that i need a recharge, or could there be some other problem? recently, i've had problems getting the unit to turn off, and had to use the breaker because it would not shut down on its own, but other than that, the unit has never had a problem. the unit is about 4 years old.


Hi, since you claim that the a/c is working but the air coming out is not cool, then you have a very low freon in the compressor and you need to refill the compressor, Or look for an air restriction. Check your filter first of all..Concer ... Air Conditioners

I built a house in Sept. 2007. I purchased 2 rheem air/heat units. I have had a lot of problems with one of the units. Unit Rheem rpne 036jaz. I have had four different repair men out to fix the unit and still have the same problem. I have had the circuit boad replace in the outside unit three times and replaced the thermostat and the contactor on the outside unit. The inside fan will kick on but the outside unit will not. I can reset the unit inside and it will work for a little while but then


... Air Conditioners

Hi there, I have two Fujitsu DC Inverter split units to heat my flat (england). The temperatures have dropped significantly -2 and below. This causes the outlet pipes to freeze up and when the units are on defrost the excess water gushes out of all other joints in the units. This causes two problems - the units are wall mounted one on top of the other, so the top unit freezes the bottom unit. The second problem is the bottom unit 'dumps' in on the floor of the area which when defrosted s


Normal cool temp 23 to 25 and heat mode 29 to 31. And regrading defrosting your pipelines no need any tray. You can insulate with Armaflex tube which is mostly used for best insulation. Hope there won't be further water leak. ... Air Conditioners

NOT COOLING I AM HAVING A PROBLEM WITH THE UNIT. I HAVE WARM AIR BLOWING INSIDE, BUT WHEN I GO OUTSIDE TO CHECK THE UNIT THE FAN ON THE UNIT IS NOT RUNNING. I CHECKED THE BREAKER TO SEE IF IT WAS TRIPPED, BUT IT WAS FINE. I WENT BACK TO THE UNIT AND GOT REAL CLOSE TO IT. I CAN HEAR A LOW HUM NOISE AS IF POWER IS GOING TO IT, BUT THE FAN ON THE UNIT IS NOT TURNING. I PLACED MY HAND ON THE TOP CENTER OF THE UNIT, AND IT WAS REAL WARM. I DON'T KNOW WHAT THE PROBLEM IS. NEED HELP


A/c unit refrigerant charge is possibly low due to leakage, call a a/c engineer ! ... Air Conditioners

My frigidaire air conditioners spit dirt all over the floor. My window unit and my through the wall unit in a sleeve both do the same thing. I called Frigidaire two years ago and they told me there were no reported problems. I keep the filters clean and don't know what is causing this. My rugs and furniture are full of dirt particles when I use these units. I have had air conditioners for many, many years and have never experienced a problem like this. Please advise me if this is a problem with


1. Turn units off\0122. Remove Filter\0123. Spray a foaming cleaner on the coils (Dow Bathroom Cleaner)\0124. Use a spray bottle filled with plain water\0125. Replace Filter and Grill ... Frigidaire FAC124 wall/Window Air Conditioner

I had a rheem r-22 old system that has been replace by a Ruud R-410A. This unit is always wet outside.The company that installed the unit, according to them they have move the bold inside of the unit, then they raised the pressures to 150[?], then they sealed the unit in the inside with some grey paint. Im still having the same problem with the unit sweeting alot. How can this problem be solve.


Is the unit outside the one sweating ? If it is that means it is working really well. Pressure should only be set by maximum efficiency and nit to change condensation. ... Rheem Air Conditioners

Compressor problem I have a 3ton goodman unit about a month ago my unit started blowing hot air found out compressor wasn't running turned unit off technician came out turn unit on got pressure readings found low charge added refrigerant the unit did well, then the problem started again i called a company out to look @ it and from what I can see he didn't have alot of experience he stayed on the phone with his boss to walk him through the situation (remember compressor is not running) he runs wa


Sounds to me like the capacitor is no good. ... Goodman CKL60AR60 Air Conditioner

I have a problem with my central heat / air unit. As it is getting cold now, I am using the heat. My problem is that I must turn the thermostat to the on position to get the unit to come on. In the auto mode, nothing happens. I can get very cold but not ever kick on until I move the switch to the on position. In the on position it works fine. Thinking that my problem was with the wall thermostat, I replaced that. I do not remember having this problem with the A/C. What should I look for to fix t


Look on your thermostat one switch (for the fan) will say off/on/auto. The other switch (for operation mode) will say off/ac/heat. The switches should be set at fan auto and mode heat. Some have an auto for the heat/ac if that is the case your thermo ... Air Conditioners

Our unit is now 6 years old. I have had a continuing problem with the fan unit rubbing on the enclosure. The only way I have been able to stop this is by partially unscrewing the top screws on the outside of the unit. The problem seems to be getting worse though, now I was forced to put a spacer between the inside and outside frame to force the inside unit away from the fan enclosure.


Is the fan actually hitting or could it be a vibration from the fan being out of balance ... Haier HWR08XC1 Thru-Wall/Window Air Conditioner

Sharp Air Conditioner AC09RLCSYS isnt cooling properly. Very moderate to low cold air from unit. At one point small bits of ice came out of indoor unit when on auto cool. Unit was switched off immediately and then turned back on after a few minutes with no additional problems, however still is not cooling properly. Unit is only eight months old. First used for cooling with no problems and great cold air, then for heating during winter. Now back to cooling and not getting the cold air like p


Unit may be freezing up if blowing ice crystals. Let thaw 24hrs try again. Make sure condensation drain line is cleaned out. ... Air Conditioners

In hottest part of day it starts blowing hot air. We turn it off for 2-3 hours and comes back on anabnd blows cold air again. Technician unable to determine problem. Says we should buy all new unit. Current unit 10 years old. Coolent level ok. Coils clean. This is a 2 ton small unit cools our master suite only. Our other unit is 4 tons and cools rest of house with no problem.


For this case, either the AC needs cleaning or the compressor may be week.  You may want to check on the thermostat, it may send signal to the unit to stop cooling.  If it is a split type AC, you may want to check for leaks in the tubes tha ... Air Conditioners

I have a Coleman roof mounted AC unit on a travel trailer. The unit model is 83338715. The unit just blows cool air not cold air like it should. I was told to replace the "Hard Start Capacitor" and "PTCR Start Device" which I did. This did not remedy the problem. Any thoughts would be appreciated. Could the problem be the "Compressor Run Capacitor"? Reason being that I hear no change in the blower sound when the unit kicks on???


Blowing 'cool air' could mean - room temperature air or it could be 'cool' because the system is low on refrigerant, and just barely doing any 'cooling' at all.\012\012To determine which is which - you need to know "for sure" if the compressor ... Air Conditioners

I have a carrier desert master Model No.38HKC24US70-01 the problem is after switch on the unit...it will work at least 5 minutes and will be in a stand by (the green light in the inner unit is blinking)for another 5 minutes and the same continues for at least half an hour.After this the unit in stand by mode rest of the full time. It was't working in the rest 23.5 hrs.Is there any serious problem for the unit or can i manager it myself


Split unit all are in timer mode we need to cancell timer mode and menual on off mode ... Air Conditioners

I have central air ( Dimond 80 York Heating Air conditoning Unit ) My air conditoning unit has stopped working. The board has checked out ok.but there seems to be a voltage problem some where from inside to the the air conditoning unit outside, the voltage reading is 26 inside and only 10 outside not enough to start the unit . Do You have any idea as what the problem might be? Thank you, drewskie


Try the following step.....On a call for heat, the 24 volt thermostat sends a signal to the\015\012control module. The control module will indicate a call for heat with a\015\012light on the control either blinking or remain solid d ... Air Conditioners

Electrical Schematic?? Hi, Here is our problem:  We have this unit installed in our desert vacation home in the wine "cellar" room, at times when we are not here, the electricity has gone out (even just for a second) and this unit shuts down and doesn't come back on until we come here and physically turn it on again. We are looking to bypass this so we don't have wine ruined while we are away.  How can we get this unit to come back on by itself?   Another problem is: this unit is installed in su


An easier solution would be to connect it to an UPS. May not be the cheapest though. ... Hitachi RAS-09UH Air Conditioner

My Carrier AC model 38CK036 fan will not spin. Unit buzzes but no spinning. fan moves freely when pushed, and no problems with furnace or thermostate. I had this problem on my 2nd Carrier unit a yeat ago. Tech replaced something in the service panal (just not sure what). I assume this is the same problem and if possible I would like to fix myself


Most likely the fan start capacitor is defective which is near the fan itself ... Air Conditioners

I have a Sanyo khs1271 that is about three years old. For the last six months it has been making a high pitch chirping sound in both heating and cooling modes. I suspect the problem is the fan on the indoor unit as the chirping only occurs when the fan speed is on high. So far, the only solution to the problem has been to turn it on quiet mode, which reduces the fan speed and thus makes the unit's ability to heat or cool less effective. Does anyone know how to access the fan on the indoor unit


Hi You can try to check this link it has the user manual.Thankshttp://www.sanyohvac.com/assets/documents/user/Use ... Sanyo Air Conditioners

Hi guys, I try to solve this problem i have with my AC unit American Standard YCC048F. Short: The heating and cooling are ok, the only problem is the fan doesn't turn off even if heat or cool turns off. Some times even if i put the thermostat is on off the fan starts running. I try to find a relay for the fan but i don't know what can be the problem. Please help, for now i am switching on/off the unit to have it run. Thank you. Costi


If the unit has printed circuit board the relay maybe in it which has probably welded contacts, must change the pcb then or try tapping it, it might help or even, try off and on power at circuit breaker it migt reset the pcb. ... Air Conditioners

My Sharp CV-P12PX air conditioner seems to have a vibration / noise problem with some insulation and/or the fan. The unit is brand new and is the second one as I had the first replaced for the same problem. Tilting the unit solves the noise problem but of course that is not a final or proper solution. Any ideas?


... Sharp CVP12PX Air Conditioner

Intertherm I have a package unit that has stated dropping out the cond. fan and comp, but contiues to run the blower motor. when I opened panel I noticed that the contactor will pull in and then drop out . this happens every few mins. The unit did this for the 1st time night before last. When I checked it yesterday morning I replaced the contactor and still had same problem. while checking voltages the contactor pulled in and the unit worked fine all day. then last night the problem returned. I


Check the board for a cold soldered joint. If you can move the spade that the line connects to it should be re-soldered. A cold soldered joint can give intermittent service because it can make contact at one time then loose contact by even a change i ... Air Conditioners

Hi, we have a problem with our Weatherking heating unit/ air conditioner. We had it installed 07/20/06. It really never has worked properly. For the last 2 summers in run's constantly. Which of course makes our electric bills outragous. Our house is around about 2200 square feet. This unit is a 4 ton unit. What could be the problem. Please help. Thank you. The model # is 13AJA48A01


Lets look at the whole problem. Did you have a new unit inside. Is the charge correct for unit. 1 lb of refrigerant makes difference. Four tons should be big enough if you have proper insulation. I have three tons in a 2100 square foot house. Its ple ... Weather King 12AJA4801AH Air Conditioner

I have a ten year old carrier heat pump unit. I recently replaced the indoor tstat. the outside contact and the transformer. Had a tech put freon in the unit also. I have to problems one is the airflow is minimal coming out of the vents it has new air filter and I cleaned the inside and outside unit coils. And the second problem is the ac with not get cold.


Two things are the most likely culprit. First check ytour inside coil with the unit running for 10 minutes or more and see if the coil is sweating there should be water running off of it. Also after one hour is there ice forming on it. These problems ... Air Conditioners

I have a mitsubishi air conditioning unit model MUH-12v. The fan on the machine outside has stopped and of course inside the air is not cold. Could this be a problem with replacing the gas or could it be a technical problem with the outdoor unit. Also I have noticed when I switch on the unit on the inside with the remote control that instead of two green lights comimg on I only have one green light flashing. Does that mean anything?


Hi,Here is a tip about Mitsubishi Air Conditioners and how to get the manuals for all of the mitsubishi line. The manual include both troubleshooting and installation. ... Air Conditioners

A/C repair problem, I have Carrier central air yntit that has stopped. Unit is 5 years old. Main Breaker/not unit is tripped and wont start unit. Madel #38CKC048360, could the problem be the easily changed Dual Capacitor part# 29-HC98KAO51D-82CWW?? Please help its 106 here!!


Yes, the problem "could" be the capacitor but we need to do some diagnostics to be sure.\015\012\015\012Is the blower motor working? (Is uncooled air coming out of the vents?)\015\012Is the contactor closed? ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"