Mea # for goodman gch95 - Air Conditioners


... Air Conditioners

My son has a Goodman Manufacturer Corp Heat Pump/air conditioner. Forced air I believe. The air conditioner quit. A repairman indicated that in order to replace the air conditioner the furnace will have to be replaced also. The air conditioner unit outside is Model No. CPE30-1-AB. Any thoughts?


I don't see any reason to change the furnace unless it's an air handler and not a furnace with a coil on top or bottom. And then, the only reason to change the inside unit when you change the outside unit is because it's a R-22 system and your going ... Goodman CKL30AR30 Air Conditioner

We have a Goodman Furnace and Air Conditioner approx 7 years old. When I put the Cool on thermostat and lowered the temperature for the air conditioner to come on the furnace fan started but the outside air conditioner only made a humminging sound. How long does it take for the air conditioner to start? I thought in previous years it came on quickly. I changed batteries in thermostat and reset the brakers on the main electrical panel. Could you please give me some advice. Thank you.


Hi, You are right. The outside unit starts quickly. The humming will either be the evaporator fan or the AC compressor itself. If you can reach into the evaporater fan with something narrow and stiff you may be able to see if the fan turns. Sor ... Air Conditioners

Goodman air conditioner parts - Goodman CKL36AR36 Air Conditioner


... Goodman CKL36AR36 Air Conditioner

Clj30-1 goodman air conditioners - Goodman CLJ30AR32 Air Conditioner


... Goodman CLJ30AR32 Air Conditioner

Goodman CK60-1C Air Conditioner Manual - Goodman Air Conditioners


... Goodman Air Conditioners

My new goodman air conditioner is not putting out cold air the air is bearly cool. Is it the thermastat or the air conditioner. Please help.


Your condensor sounds like its not working check the breaker box ... Goodman Air Conditioners

AIR CONDITIONER MY GOODMAN AIR CONDITIONER IS NOT WORKING WELL. IT IS NOT GIVING OFF ANY COOL AIR. I ALREADY CHANGED THE FILTER HOPING THAT WOULD WORK BUT IT IS STILL DOING THE SAME THING. MY UNIT IS ONLY ABOUT A YEAR OLD. WHAT COULD BE THE PROBLEM?


Do you have any frost on the lines going to the outside unit. If the large line is frosted your evaporator (Cooling coil in the furnace) could be frozen up. Operating it with the fan in automatic with the cooling on will sometimes be the cause of thi ... Goodman CLQ36AR49 Air Conditioner

Air conditioner blows out hot air - Goodman PHKJ048-1 Air Conditioner


1. Change the filter. Then turn on the A/C "fan" switch from AUTO to ON. What has happened is the cold air that was being produced by the A/C until couldn't push the air through the vent because the filter was too dirty. Clogged. Thus creating ... Goodman PHKJ048-1 Air Conditioner

My air conditioner air handler humsbut moter does not turn on compressor runs ok Goodman air conditioner


Either bad motor ....or.... if you are lucky a bad run capacitor. you will need some sort of capacitor checker and multimeter to diagnose it further. ... Goodman CLQ36AR49 Air Conditioner

Fuse for goodman air handler - Goodman CKL36AR36 Air Conditioner


... Goodman CKL36AR36 Air Conditioner

GOODMAN WMC241KFAJ AIR CONDITIONER MANUAL - Air Conditioners


... Air Conditioners

Goodman air conditioner CLJ42-1C - Air Conditioners


... Air Conditioners

Wiring diagram for goodman air handler - Goodman CKL36AR36 Air Conditioner


... Goodman CKL36AR36 Air Conditioner

I have a Goodman CKL 49-1 air conditioner. It keeps tripping the circuit breaker in my fuse panel. Any idea as to why it started doing it, could it be a bad breaker in the fuse panel or a fuse somewhere located in the air conditioner.


Usually its a bad motor, compressor or even contactor like a dead short your breaker trips to tell you there is a problem ... Goodman CKL49AR49 Air Conditioner

Air conditioner tripping circuit breaker - Goodman CLJ30AR32 Air Conditioner


... Goodman CLJ30AR32 Air Conditioner

Goodman air handler a24-10 wiring diagrm - Goodman Air Conditioners


... Goodman Air Conditioners

Check capacitor on goodman air - Goodman Air Conditioners


Inside the electrical panel, silver or gray capacitor. It will have the numbers printed on it, like 35/5 or 45/5. Usually, you can visually see if the capacitor is swollen or blown. To actually check the capacitor the correct way, you need a meter th ... Goodman Air Conditioners

I have a goodman furnace and air conditioner. When the air conditioner is running, it runs for about 10-15 minutes, then shuts off for about 5 seconds, then restarts. Could you tell me what would be wrong? I think also associated with this problem, when the heat is running, the furnace will run for about an hour, then shut down, even though the temperature has not been reached. Resetting the breaker, or depressing the reset switch in the thermostat will start the furnace running again. A third p


Try running viniger through it , clean or replace filter , if filter was real dirty you may want to have your evap coil cleaned ... Air Conditioners

I have a Goodman CKL24-1k air conditioner. I live in a townhouse in Louisiana on the 2nd and 3rd floors. I set the temperature to about 73 degrees during the day so I can sleep bc I work the graveyard shift and the temperature never reaches 73. It stays between 85-90 on the 3rd floor where my room is located. The unit will run all day and never shut off. this air conditioner equip to cool and split level apartment about 960 sq ft?


... Goodman Air Conditioners

Goodman air fan hums wont turn - Goodman CLQ36AR49 Air Conditioner


Either has a bad start capacitor or bearings have gone dry, and shaft is stuck. Motor would probably have to replaced. ... Goodman CLQ36AR49 Air Conditioner

My air conditioner doen't start. I have a goodman air cond.


Check to make sure that the power is on to the outdoor unit and the furnce. Check breakers and fuses. There may also be a disconnect outside located by the condenser. It is probably a gray box, loft the cover and make sure the shitch is on. Otherwise ... Goodman CLQ36AR49 Air Conditioner

Goodman 12 seer air conditioner. Initally turned


... Goodman Air Conditioners

Air condition not blowing cold air - Goodman CLJ36AR42 Air Conditioner


Large copper line coming from outdoor unit should be cold,If not you need recharge or compresser is turning on. ... Goodman CLJ36AR42 Air Conditioner

Goodman air conditioner model #PC036-1a; when you put on heat the unit kicks on and blows out air with no problems but when you try to turn ac on, you can hear the motor click on like it's trying to start but no air blows out of the vents. thought it might be the relay switch? any suggestions


Try replacing the control board most the time its a relay stuck open for high speed on your fan ... Goodman Air Conditioners

A detailed question is important to get you a relevant answers