Air conditioner constantly shuts off

\015 One day I smelled smoke coming from the AC outlet. I have a extention cord coming from the unit into the AC outlet because it isn't long enough. I immediately move the plug to another outlet. Now the AC runs for about 10 minutes than breaks the circuit breaker. Can anyone help me resolve this issue?\015

Answers :

Are you saying that you have plugged the aircon into an extension lead then into a socket in the wall and that the smoke was coming from the extension lead part. If so I would suggest checking all your plug in connections and chenge the extension lead. A quick way to check the compressor is a cause is to put the aircon to fan only and see if it fails to trip out the circuit breaker, then put it back onto cooling and see if it trips (if it does on cooling then its a good possibility). Most aircons have a three to five minute time delay for starting the compressor to protect against power fluctuations (ie power cuts). Hope this s of some help.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Air conditioner shuts down constantly, need to


Sorry but you are just going to have to keep emptying it. These types or air conditioners are also use as de-humidifiers and unless you can place it somewhere where you can connect a drain hose it is going to require many trips to dump ... LG LP1200DXR Portable Air Conditioner

Constant cycling My RV air conditioner cools then shuts off. In less than a minute it starts again, runs for a minute, shuts down and repeats this until it gets on your nerves. Doesn't seem normal. What's up?


Do you use a inverter.. or any protection circuit>if so remove it and connect it directly ... Dometic Rooftop RV Air Conditioner

I have a CS-E24FKR Air Conditioner,, Timer light constantly on ,,Blinking 60 blinks per min Turn Power off at Supply.Turnback on Remote w2orks allOperation details.. Shuts down aftewr 8 minutes runnin


... Panasonic Air Conditioners

Air conditioner constantly shuts off


Are you saying that you have plugged the aircon into an extension lead then into a socket in the wall and that the smoke was coming from the extension lead part. If so I would suggest checking all your plug in connections and chenge the extension lea ... Frigidaire FAC107P1A Wall/Window Air Conditioner

The electricity went off in our neighborhood yesterday. It came back on. I do not run my central air this time of year so the air conditioner is in off position. My fan is on auto but this usually means it is also in off position. When the electricity came back on yesterday the fan came on (not the air conditioner) and is continually running. I cannot get this darn thing to shut off. I have looked on the internet and made serveral attempts to get this fan shut off. I do not want to pay for


Hello Sounds like runaway blower.The relay in the blower unit is stuck/welded & should be replaced.In the mean time you can turn off the service switch at the unit.If you tap the relay it will shut off (for now) untill the next demand and get stuck a ... Air Conditioners

Sometimes, our furnace will start blowing cold air when it should be blowing hot...I know it is normal that it blows hot air and then will blow cool air as it cools to shut down. This is not what I am talking about. I am talking about while the furnace is blowing hot air to heat, it will quit blowing the hot air and start blowing cold and it it like the air conditioner kicks in. It will then continue running cold air...I usually have to shut the furnance off and when it kicks back on it will


Do you have an automatic change over thermostat? this would switch it from heating to cooling. ... Air Conditioners

I have a goodman furnace and air conditioner. When the air conditioner is running, it runs for about 10-15 minutes, then shuts off for about 5 seconds, then restarts. Could you tell me what would be wrong? I think also associated with this problem, when the heat is running, the furnace will run for about an hour, then shut down, even though the temperature has not been reached. Resetting the breaker, or depressing the reset switch in the thermostat will start the furnace running again. A third p


Try running viniger through it , clean or replace filter , if filter was real dirty you may want to have your evap coil cleaned ... Air Conditioners

I have a new motorhome and the air conditioner only reduces the inside air temperature by 2 degrees on a hot day. e.g. outside air temp 26 degrees inside temp 29 degrees. After 2 hours of a/c running with door and windows shut inside air temp is 27 degrees. Dealer says the air conditioner is ok as air coming out of ducts is 3 degrees as required. I believe a larger a/c is required.


Can you tell me what size/make of motorhome you have? Certainly doesn"t sound right to me, and I've been working on them for over 15yrs. Whether it's a 13,500 BTU or 15,000 BTU, it should be plenty as long as motorhome has any insulation at all. I a ... Dometic Rooftop RV Air Conditioner

Error code on Enigma SLR-35 air conditioner. The error code is L1, air con will come on for a minute or two and then shut down displaying this error code. I don't have the manual for this air conditioner as it was in a house I just purchased and was just wondering if anyone knows what this error code means before I call in a repairman to investigate. I have tried cleaning the filters and resetting my circuit breakers for the house. No success obviously. The air that does come out for the minute


... Air Conditioners

Water tank full light keeps coming on an shuts the AC off after about 10 minutes on a Amcor A12000E Nanomax Portable Air Conditioner. I drained all the water out of it I could and it does turn back on after I turn it back on and will run for about 10 minutes. Then it beeps 6 or 7 times and the water full light comes back on and shuts it off. There is no more water coming out of it and there is a buzzing when it comes back on but it will blow cold air until it shuts off again. Please help!


Dod u get any help with your problem because i am having the same problem and ofcource the company is no longer around ... Amcor A12000E Nanomax Portable Air Conditioner

Air conditioner unit outside, fan not going but air is coming out of the vents. The thermostat is on 50 degrees. If it is shut off for a while and turned back on it will turn on but after and hour it will shut off. Sometimes it will run a day and then shut off but will not go on again. Any suggestions?


Is the fan out side running when you are getting cool air? IF so check the out door coill is it clean, If not the fan could be over heating because it is pulling to hard. you should be able to feel the air 2' above the unit. ... Goodman CKL24AR24 Air Conditioner

I have a Coleman Central Air/Heat System. This year, the outside compressor (or whatever it is called) is shutting off within minutes of the air conditioner coming on. This is resulting in the home never cooling down. I can reset the system by shutting the air off inside the home for a few minutes and the outside compressor comes back on, but again, only for a minute or two, and the unit only blows what seems to be room temperature air.


Do you know the devices model. It would help in locateing the manual. also I beleave you have the manual?\015\012\015\012As micromaster already said, check for sleep timer.\015\012\015\012has the system worked fine before has ... Air Conditioners

I have a comfort control 2200 thermostat. I changed the batteries and the thermostat is set to 80 degrees. The air conditioner stays on and the temperature on the thermostat is stuck at 80 degrees but the house temperature is down to 75 degrees and the air conditioner will not shut off unless I turn the thermostat setting to 81 degrees.


May be the location of the thermostat. Try another thermometer right beside wall thermostat & see what it reads. ... Dometic Rooftop RV Air Conditioner

I have a Goodman CKL24-1k air conditioner. I live in a townhouse in Louisiana on the 2nd and 3rd floors. I set the temperature to about 73 degrees during the day so I can sleep bc I work the graveyard shift and the temperature never reaches 73. It stays between 85-90 on the 3rd floor where my room is located. The unit will run all day and never shut off. this air conditioner equip to cool and split level apartment about 960 sq ft?


... Goodman Air Conditioners

I cant get my air conditioner to work without the remote ..once i plug it in ..it stays on for 10 seconds and shuts off and will not operate using the buttons manually on the air conditioner itself


... Haier HWR08XC7 Air Conditioner

Hi, Our Moretti Elite Portable Air Conditioner unit shuts off after 1 minute and will not run continually. Can you please help? Also where can I download a manual for this air conditioner? Thanks Jacqui Briant


It's based on error code of E-2.It's problem with indoor coil sensor.Replace. Helpful? ... Air Conditioners

I have an Edgestar Portable Air Conditioner AP12000HS. The Air Conditioner works wonderful, however I can't get it to heat, I put the Mode Button on red which is supossed to put the heater on, it will run for a few minutes and then shut off and it does not take the chill out of the room I have the unit in, is there some kind if thermostat internally which can be set? The way it runs now does not do me any good as a heater.


The unit has a built in thermostat in the front control panel, this is what maintains the set temperature, it is very likely that this control is defective, all the controls for the unit are contained in the CCU (central control unit) ... Air Conditioners

The air conditioner is cooling but it does not seem to be cycling correctly. The air conditioner runs constantly when the temperature is over 85 degrees outside.


Hi,\015\012There can be a couple of things that could be happening...\015\012The first and easiest thing is to check the air filter. Make sure that it is clean... clean it or replace it. Next check the air vents to make sure that they are ... Air Conditioners

I have a Comfort-Aire Model RAH-123A Room Air Conditioner and Heat Pump. When depressing the low or high heat control button, the unit hums like it wants to start but shuts off in about 3-5 seconds. My suspicion is that the compressor is trying to start but a thermal cutout shuts it down when it does not start. The unit was installed as part of a sun room addition and the remodeler is no longer in business. If I cannot solve this problem through the internet, I need a local contact fro servic


Hi!\015\012Before I give you a possible solution to your problem you need to check the heating temperature Control, set it to a warmer setting, if problem persists, check the power cord.\015\012\015\012To test your power supply cord:\015\012\0 ... Air Conditioners

My SM18J30A air conditioner runs for a couple of hours then automatically shuts off and I get an E2 message in the air conditioner window. What does this mean


Clean both coils(fins)and drain///use a non-detergent non additive oil(not motor car oil) for fan motor take cover off compressor relay and inspect wires(clean plugs and pins of oxide) you may need a hard start kit if it has a hard time starting you ... Air Conditioners

I turned on the air conditioner and forgot to remove the cover from the winter. The air conditioner shut off and now won't go back on after cooling down.


Hi!!\015\012\015\012It probably trip the breaker, or blew a fuse. if these to are OK, open the return grill and inspect wiring.\015\012\015\012Don't forget to rate this post!!! Good luck!! ... Dometic Rooftop RV Air Conditioner

I have a Feddders A7T12FA air conditioner. It was just put in for this summer and it is now not working. When I first plugged it in, the control panel would light up, air would come out briefly and then it would shut down. This happened twice. I then got it turned on after taking the plug out and putting it back in. It was turned on less then 5 minutes before it shut off and now I can't get it to start up again at all. Please help!


Unplug the AC remove the casethen follow the plug wire until you see a fuse this is probably burned out but, is only a symptom not the problem next look carefully at the silver cans with the wires on top these are the run and, start capacitors one sh ... Air Conditioners

Comfort-aire wpc30 air conditioner: water control valve does not shut off completely when compressor shuts down.


Dirt most likely. ... Air Conditioners

My maytag M7D24E7A's compressor runs for 15 minutes and shuts off and doesn't come back on until we restart the air conditioner. How do we fix it so we don't have to restart the air conditioner every 15 minutes?


... Maytag M7D24E7A Air Conditioner

My air conditioner keeps shutting off and on - Frigidaire FAC127S1A Air Conditioner


Hi Brittany - When was the last time the filter was clean? Restricted air flow from dirty air filter can caused air conditioner to turn on and off rapidly. Make sure there is nothing blocking the airflow to the unit like blinds, drapes, furniture, ... Frigidaire FAC127S1A Air Conditioner