My unit is running but not cooling

\015 A couple days back I noticed the inside temp to be 90 degrees so I looked indoors and out, I noticed my outside fan not running. so I hit the circuit breakers and tries turning unit off then on and the fan would only turn on for moments, the unit is running but no cold air. I cannot reach the main unit-it is in the garage ceiling, this has never happened before. I only rent the place but if it is a easy fix Ill do it myself. Any suggestions?\015

Answers :

Hi,\015\012 Probably not an easy fix. Sounds like its shutting down on Low pressure or High pressure. Could be condenser fan motor. The easiest thing it could be would be a run capacitor on the fan motor. They usually swell up and or leak oil when they go bad. You could check on that but make sure all the power to the unit is shut off before working on it. I would just call the manager or owner myself if I were you. I'm sure he is charging enough rent for him to cover such problems. Hope I have helped.\015\012kstfas

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a carrier Modle No. 38YXA042300. I am getting an H5 error message on my Thermistat Control. I have run the Fan only mode and the fan in the air handler unit works fine. On the unit when I ingage the manual override, the condener unit and fan motor runs and cools. The unit will not run when I put the Thermidistat on Cool mode. Can you help me. Andrew Construction Mangement Speicalthes, Inc.


On some carriers they have a lock out feature outside to reset shut down power to furnace for 90secs. and then restart ... Air Conditioners

This is a heating and cooling through the wall heat pump. It works normally when heating is selected - the heat pump runs and both speeds of the fan blow warm air. But nothing runs when cooling is selected. In other words the unit works normally when "High Heat" or "Low Heat" is selected but nothing runs when "High Cool", "Low Cool" or "Fan Only" is selected. The position of the Fan Cycle Switch has no effect - behavior of the unit is the same in both positions of the Fan Cycle Switch.


You have a bad board or bad switch. I would say board. You can have service tech check this out. There is only so far you can go without knowledge of Controls ad electricity. Russ ... Air Conditioners

I have a duo therm a/c roof top unit that is not cooling properly it has been approx 2 years since the unit has been run I have checked breakers and fuses in breaker box I removed the cover from unit the compressor is running and getting hot the lines are cool but not cold the fan is running I am thinking that the unit is low on freon can some type of self tapping ports be installed to add freon or have ports soldered in place or could there be another underlying problem that can be checked or i


You have a leak in the system that needs repair. If you have to add freon to system there is a leak. You need a service tech to do the repair. If it is out of gas you may to replace it. Leaks do not correct themselves. Russ ... Dometic Rooftop RV Air Conditioner

1996 Coleman Model 7333C8876. Have 2 units on our Motor Home one day it was hot so I had both units running controlled by a Electronic Climate Control system. It got cool in the evening so I turned them off. The next day when i fired them both up on high the rear was fine. But the front will only cool on Low. The fan will not run on high and you can hear a slight noise coming from the unit. But the fan will not run on high.


Check to make sure the drain tube is clear. It sounds like the blower fan is dragging in water buil-up. ... Air Conditioners

Fedders Model No. A7U12W2A-A, 12000btu airconditioner. The unit has been cooling satisfactorily for two to three years. Today the unit was cooling and suddenly there were a couple of reasonably loud knocks and the compressor stopped cooling. The fan continues to run. In about five minutes the cooling comes back on. The compressor runs for abut four minutes and shuts down. Earlier today we had a power dip without losing all power.


Hi, the power dip when translated means low current actually affected the relay starter which is situated beside the compressor. Now the relay starter works and stop intermittently which is why the Compressor cools whenever it works and does not cool ... Fedders Air Conditioners

I have a 2 year old Duo Therm 15,000 btu Heat Pump AC unit in my RV. The compresser will not come on or even try, in either cool or heat mode, the fans runs in either auto or on position. I have a wall thermastat, all wires & connections at the thermastat and the controll box look good. The units was running fine, with no prior symptoms and then it just stopped cooling. I have a strong electrical background with all the meters, I am just not famaliar with RV AC units. Bud De Fore don


Hello Bud,First of all, is your wall thermostat a digital thermostat, like a 4 or 5 button Comfort Control Center? Is the ambient temperature under 40 degrees?Is your fan still able to run, are you able to control ... Dometic Rooftop RV Air Conditioner

Amana PTAC Unit is not producing heat. Fan works fine. can not locate manual reset for heat although a label on the unit says there is one. I have an Amana pth153b35ae ptac unit that the heat will not come on. The compressor will run in the cooling mode but not in heat mode. I verified the switching valve is working and the capacitor seems to be fine as the compressor will run in cooling mode. The thermostats seem to be functional because relays can be heard clearly when changing temperature se


I know this is late but I had to add a solution to this problem since I had the exact same problem and was able to solve it. The probelm is not your control board. On these units, the heat pump compressor will not kick in unless the temperature you ... Amana PTH123B25AJ Heat Pump Air Conditioner

Unit will cool for about 10 minutes and then compressor shuts off an unit blows warm air for about 10 minutes and compressor will start again blowing cool air and then compressor will shut down again and unit will blow warm air ... etc. the unit is running off a generator to cool down a 10x14 enclosed trailer and does not do the job of cooling


... Haier CPN10XCJ Air Conditioner

Hi. I recently installed 1.5 T, 3 * Split AC, LG. Whole day the AC works fine and no problem in cooling too. But once in 2 day outdoor unit start making thudding noise continously and does not stop for 4 to 5 second and after that indoor unit stops cooling and just fan runs. No cooling is done after that and room temperature keep increasing. The green LED of compressor in indoor unit is ON, compressor does not work. To achieve cooling again I have to switch off whole unit for like half an hour a


HelloSounds like the compressor is shuting down on high heat.There could be a couple reasons for this.1 Check that proper voltage is being supplied to compressor.2 Freon level may be low.This would be a service call.3 Ba ... LG Air Conditioners

Unit runs but will not cool. Fanruns fine but when turn dial to cool the compressor kicks in for about a second or two the kicks out. Fan works on cool but it will not produce cool air at any temp setting. I have cleaned filter and removed cometic facing and vacuumed the coil face. It was pretty dirty but after all that still would not cool, Unit is installed in a RV and power is provided from house. Gen4erator is also available for power. Unit is difficult to remove from RV and space to get at


You may need to install a hardstart kit if you can get to the compressor.\012go to your nearest appliance parts store to get the part and the instructions are usually on it. If not ask the parts man.\012\012If this was helpful pleas ... Air Conditioners

My AC unit is not blowing cold. I have two. One small and one big . I just noticed that My upstairs was not cooling off. So I turned both units on and went out sid to check them. The small one is running fine fan blowing cold freon running through. The big was not running at all. I sprayed them off and while doing that the fan on the big unit began to turn. Now it is running but every now and then it keep making a noise like a motor is trying to turn on. and the freon line is not as cold as the


The start capacitor is in question and the fan appears to be overheating, That is where the water camre into it. You may need a HVAC tech to make your repairs. Good Luck _Ned_ ... Air Conditioners

AC Out. Two year old house. Goodman A/C, two units one for upstairs. Cleaned coils of both outside unit, replaced filters, re-set breakers. Upstairs is cooling. Downstairs unit is running outside, not circulating air inside (inside temp 87). Vents inside are cool to touch, no air. Outside unit fan is pulling, but air exhaust is cool. Compressor ? Should air be circulating even if compressor not functioning. Is there anything in attic exchange that would affect downstairs circulation. Thanks.


Assuming that the 2 systems are isolated, that there isn't any cross over between the systems...It is normal for an air conditioner system, from window unit to central, to be able to circulate the air, even if not cooling. This is known ... Air Conditioners

I have a Duo Therm Quick Cool, model 59516331, mounted on a 2001 Dutchman. With the A/C on it cools great but the compressor does not kick out or cycle. The unit runs until it freezes and can't blow air. When I shut the unit off manually from the thermostat the compressor continues to run, the only way to shut it off is to shut the breaker off. I am wondering if it could be the thermostat? I have checked everything I can think of. Any advice for me?


... Air Conditioners

Ac units in apt. is fully charged,but it blows cool to cold air and will constantly run all day with out shutting off. at night when it cools off outside it will run like its supposed to. the fan unit outside said bryant on it.


Your ac thermostat is defective and not switching off the compressor resulting in excess cooling and need replacement. Also ensure that all doors and windows are closed. Could be some window is opened behind the curtain without your knowledge. ... Air Conditioners

I have an older ac roof top unit (1988) its made by Coleman. When you first turn on the unit as long as it is cool, it will run for about five minuets on the low speed cycle (very cold), if you switch it to high cool it will run for about one to two minuets then it will trip the house breaker (20amps), not the couch breaker (30amps). I replaced the start cap, motor cap and another unnamed cap. The only things left in the system are a start relay and a thermal cut off switch which sits on top o


Take a current reading on the compressor and the fan motors to see witch one is pulling the high current. ... Air Conditioners

Hi guys, I try to solve this problem i have with my AC unit American Standard YCC048F. Short: The heating and cooling are ok, the only problem is the fan doesn't turn off even if heat or cool turns off. Some times even if i put the thermostat is on off the fan starts running. I try to find a relay for the fan but i don't know what can be the problem. Please help, for now i am switching on/off the unit to have it run. Thank you. Costi


If the unit has printed circuit board the relay maybe in it which has probably welded contacts, must change the pcb then or try tapping it, it might help or even, try off and on power at circuit breaker it migt reset the pcb. ... Air Conditioners

HAVE A COLEMAN MODEL DRHSO601CB --- THE UNIT WILL RUN FINE FOR SEVERAL HOURS WITH GOOD COOLING AND THEN PERIODICALLY THE TROUBLE LIGHT WILL COME ON THE THERMOSTAT AND THE UNIT HAS SHUT DOWN. TO RESTART - YOU MOVE THE THERMOSTAT TO OFF WAIT 5 MINUTES OR SO AND PUT IT BACK ON COOL -- IT WILL RESTART ALMOST EVERY TIME AND RUN FOR SEVERAL HOURS. IN THE PAST IN THE PAST I REPLACED THE DEFROST CONTROL BOARD BUT WHEN I DID THAT THIS TIME IT STILL SHUTS DOWN - WHAT OTHER PROBLEMS ARE YOU AWARE OF ON TH


You may have a low pressure or high pressure switch tripping out the board as well. You might try cleaning both the indoor (evaporator) coil and the outdoor (condensing) coil. Be sure to turn off the power source before servicing this. ... Coleman Air Conditioners

I have a Mitsubishi MS-09D wall mounted air conditioner. The cooling function does not seem to be cooling. The fan is running but the it seems to be recirculating the air only. The defrost light is red on the wall unit. I don't recall this light ever being on before. Could a button or combination of buttons on the remote unit have been bumped somehow? Could you please tell me how to reset the remote control or wall unit to have the cooling operation to come on again? The air ducts are clean,


... Mitsubishi Air Conditioners

Good day! I am running my Carrier A/C Model 38EYG and it is running fine...the outside unit is running fine and the air coming out of the ceiling vents is cool. However, the inside unit (the one in the closet) is very hot. When I walked by the closet it felt like I was walking by an oven. I checked the temperature with my handy temp gauge and it was reading 120 degrees near the top of the unit...is this normal??


No its not normal. Check and make sure there is no flame inside the furnace. If not , turn the pilot light off it is a gas furnace and see if this makes a difference. good day to you too. ... Air Conditioners

Friedrich YM18 230 volt heat pump. The unit has heated and cooled well for about 5 years. Just started heating mode recently and the unit no longer heats. Fan runs OK. Was able to get the heat strip to run for a few minutes (smelled the dust accumulated over the summer burning off). Now, no heating whatsoever. When in the "Money Saver" mode, nothing happens. Fan will not come on and unit will not heat. With "Money Saver" mode off, the fan runs.


... Friedrich Air Conditioners

I have a Comfort Aire PE121A that will not cool or heat. It is about 3 yrs old, and it just barely cooled when I got it. It is a 12000 btu unit, but I have a window mounted 6000btu unit that will run cooling circles around teh PE121A. What is wrong with the unit, and is there a repair service in or near Eugene Or that can look at it. It acts like there is no coolant in it; poddibly has a leak???? What can you tell me? My e-mail is [email protected] Thanks in advance for your assistance.


... Comfort-Aire PAC-121 Air Conditioner

My unit is running but not blowing cool air. I went outside and the condenor fan was not moving. Took a stick and shoved a blade and the fan started moving but the air is still not cool inside. I did notice the air coming through the unit outside after fan was blowing was cooler than my 2nd a/c unit that was working fine. I wondered if the entire unit was frozen. I turned off unit at thermostat and figured I would see what happens tomorrow


Sometimes on new units it is common for the fan to not start until you give it a push. Did you happen to hear if the compressor was operating? If the unit was froze-up the Insulated Suction line would also be iced over as well. If it wasn`t it is mor ... Carrier 38CKC024 Air Conditioner

I have carrier split unit the problem is the when switch it on indoor unit runs but when outdoor unit runs it make cool just for 5 mins and all unit indoor and outdoor go shutdown and green light start blinking and after 5 mins unit starts again after 5 mins again shutdown . any sugges please.


... Carrier 38CKC036 Air Conditioner

Hi, I have a samsung aqv18ja series split type air conditioner (cooling and heating) wall unit. the unit was install in 02/12/2009. By "one hour heating and air conditioning". In this short time service the outside compressor has been replace, the system has check and recheck,for cooling leak. the inside unit fan motor has been change. but the problem still exists. The inside unit fan continues to run when the unit is "off" and with the remote off.


Simple, check in your remote. There is an option button "Blow". Just press it. Your unit gets completely off. Please write back if helpful? ... Samsung Air Conditioners

This is for a Friedrich QStar SQ06J10 AC unit - When switch is normally shifted to the 'cool' position ('on' mode), it seems to not complete the circuit. Jiggling or pressing hard on the switch will make the unit run, but one has to hold the switch. Can a DIY-approach fix the connection, so the unit will run as expected? or does the switch panel need to be replaced? Relatedly, might it be 'better' to simply swap out this unit for a newer, possibly more-efficient unit?


... Friedrich QStar SQ06J10 Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0756 seconds