How do i bleed a junkers eurostar 24kw combi boiler


... Air Conditioners

I have a 48 year old Bryant Boiler in my home for our heating system. I need to bleed the boiler as there are not any places to bleed the radiators. How do I bleed the boiler


Why do you need to bleed the boiler. this just means drain it. if it is air locked at the rads you need to get rid of the air ... Air Conditioners

Please can someone help me!! We purchased 1 year agao a Viesmann Vitodens 100 Combi Boiler and have had major problems with the flow switch sticking. We have had 3 sub contractors come out and replace the flow switch and a Viesmann engineer come out very recently blaming the water for the problem with the flow switch!! Their are around 70% of combi boilers sold throughout the uk and water is a big part of a boiler working, we also found out that we should have a filter fitted to the main


I am pleased to suggest that you try to following. i would wager that the switch is installed in the horizontal position. try replumbing so that the switch or valve is verticle to the ground. . that way particles will settle down with water flow an ... Air Conditioners

Vokera PRO Combi 85 HE Condensing Combi Boiler hot water is fine but boiler doesn't cut in to heat the rads. please advice


... Air Conditioners

We have a Worcester Bosch Highflow 400 (10 year old) combi boiler. Over the last few weeks when we have put on the heating the boiler kicks in and fires up and the heating comes on (the water comes on fine too) but the boiler keeps clicking off after a few minutes so the heating goes off (but the water seems to be still on). The radiators remain just slightly warm but we can't seem to get the boiler to stay on. Th heating and water lights are on and it sounds like it is working but the heating k


The by pass pipe may be limed up. This apparently causes a reduced flow which will stop the heating side of the thing working. Call out Worcester Bosch engineer. It costs £210 including VAT and most parts and they almost guarantee to get it wor ... Ruud Matching Split Air Conditioner

Hi,i have a vaillant turbomax combi boiler,the radiator side is working well but when running hot tap the boiler kicks in for about 5 seconds ,hot water starts to flow then boiler cuts out,water runs cold agin then boiler starts and this cycle repeats.can anyone help?thanks in advance.mark.


Which turbomax, as there a two different models. The more modern one, with the brass CPL diverter valve, located at the front left of the boiler, was very prone sticking & jamming, this would restrict flow through the hot water circuit in the boi ... Air Conditioners

Rhino 90 oil combi boiler.


... Air Conditioners

I have a Myson Midas boiler, got hot water but no central heating, the fan is working as is the c/h pump, the boiler trys to fire but fails to do so. The property has ben empty for at least 12 months, i don't know if the system was drained so what is purging the system does & the instructions say to vent the boiler by removing a screw at the top & vent the radiators, is that the bleed screw at the top of the radiators & do I undo one at time or all at the same time, thanks.


... Air Conditioners

Combi boiler goes to lockdown.think problem lies with the gas flow.the boiler is supplied with lpg bottles with automatic change over regulater.is there a simple way to check gas is reaching the internal gas valve


... Air Conditioners

ENGLAND, UK. DOMESTIC HOUSE CENTRAL HEATING; i recently fitted a thermestate valve on one of my radiators, it works fine. but since I have turned it all back on i seem to have air in the system, that makes a loud sound in the boiler. We have an old back-boiler system (behind the fireplace). how is it best to get rid of the trapped air? Re-drain the system? Bleed one radiator at a time? which radiator should i start with?


Hi you need to bleed each radiator one at a time start with the rads up stairs first then work your way down make sure all the rads are turned on at the valve when doing this but make sure the boiler is off so you dont have boiling water coming throu ... Air Conditioners

Bled my radiators yesterday, and now the water pressure gauge on the bioler is at zero - it wont start up below a pressure of 0.5. I suspect the boiler is air-locked. Any ideas on how to bleed it?. Its a vokera 20E boiler


You boiler is more than likely low on water. There is normally an automatic water feed. When you bleed a system the pressure naturally drops but is compensated by additional water feed into system. You have a problem in the pressure make-up water fee ... Air Conditioners

We have a vaillant combi boiler model 824 plus, it is hit and miss if it fires up for hot water.The pump runs the fan runs but no flame. when it doesnt fire the diagnostics on the front of the boiler show S13. Can you help


... Air Conditioners

Switch heating on, hear a click that we normally hear then boiler fires up. Then goes off after about 30 seconds. Then won't come back on, though we still hear the click. Wait a while before trying again and it fires up and goes off. Won't stay on. It is an Ideal boiler, not a combi. We are replacing soon but could do with it to keep going for a few weeks more. Any ideas please?


Could be a number of things, it could be cycling on the high limit switch, (lack of water flow, or pump) this would be my guess if you are not resetting power and the unit is trying to restart. It also could be the flame sensor not proving ignition. ... Ruud UBHC Air Conditioner

I have a vitodens 100-w combi boiler and tried to turn the heating on just to give it a working as was advised. However, I have no heat coming to my radiators. The boilers seems to be working as my hot water is fine and no fault displays are being displayed. Have turned it off at the mains and restarted it, but has done no good. Any ideas?


Here's the deal: If your Vitodens 100 has outdoor temperature sensing capability, either built in or via external aftermarket control such as Tekmar or other, and the temperature outside is above warm weather shut down (WWSD), then the boiler will no ... Air Conditioners

Hot banging i have a evo he c22/24 combi boiler when i use the hot water and turn it off the boiler bangs but only when turning off.


It sounds like water hammer, you need to install a water hammer device at the water outlet of the boiler. aviliable from any plumbing stores. ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

I have a Baxi combi boiler 105e and a Honeywell ST6100C programmer/controler, and i wish to add a Seimens wireless digital room thermostat RDH10RF/Set. the RCR10/433 unit needs to be wired to the boiler/controler above so that the thermostat switches the boiler on and of when demand for heat is called for by the room thermostat unit RDH10RF. can you please advise on how to connect the wiring or if it is possible to get a wiring diagram many thanks Paul


... Honeywell Air Conditioners

Have fixed previous problem I had with my Britony Combi SE but I now have a new problem. Boiler resets OK and all is showing as it should. However, as soon as I try the heating or hotwater the boiler fires up for about 15 seconds and then blows the trip switch on my fuse box. Any ideas.


Either too much current draw or breaker is to small. What size breaker do they recommend? What size do you have?If the breakers are sized right then there may be a problem with the heating circuit. ... Air Conditioners

I have a Honewell CM921/927 wireless programmable room thermostat that is operating the combi boiler in AUTO mode even when the time setting is meant to be off (no output). The target temp is 20 deg and the room may be 21 deg for example, but still the flame icon appears on the lcd screen of the thermostat and the radiators are luke warm continuously. Once the time reaches a preset the boiler kicks in fully to give proper heating and the radiators become very hot. Any help to allow the therm


... Honeywell Air Conditioners

Combi boiler wont re-pressurize when i turn the little valve under boiler it just seems to run and run and the pressure gauge dosent go up at all? there are no leeks. but a minute a go it went right up to the red and wouldnt close then shut off,it restarted fine now it wont go up at all?


Check to see if your pressure relief valve is partially open. This is about all it could be unless you are losing flame under the boiler vessel.\015\012\015\012Thanks\015\012Zerko ... Air Conditioners

I have a alpha CB28X combi boiler which was working this morning came in a hour ago went to put heating on and noticed red and green light flashing. I have noticed red on own before and just set reset which worked this time reset does nothing. There is no response from boiler i.e no noise can you help?


... Air Conditioners

Ariston micro genus combi boiler central heating works okay but domestic hotwater fails to rise but burners seem to be lit and the boiler doesnt appear to cycle dhw temp gets to about 30 degrees instead of max 56,baffled thinking temp sensor?


Having found a circuit diagram, realised that the divertor valve was electrically operated.i unplugged this then unclipped the motor from the valve body,the diverter valve is spring loaded and once i'd removed the motor the spring raised the valve to ... Air Conditioners

Have a combi boiler and the hot water from my taps are running cold to luke warm. My British Gas engineer has told me it is nothing to do with the boiler but is caused by a faulty thermostat cartridge in my shower mixer. Is this right?


Hydro line b24 hot water running hot cold ... Air Conditioners

Baxi Bahama 100 combi boiler. The flame failure light comes on, boiler will not run. There are sparks at the elctrodes. Center row on burner lights up but weakly. Other burners do not ignite then shuts down. But if I take off the combustion box door panel it works perfectly. Door on, no flames.


... Air Conditioners

Radiant combi boiler put hot water tap on boiler fires up then goes out then lights up again and keeps on doing that


Either defective sensors, or check the flow temperature going into the plate heat exchanger, if this getting very hot, but not circulating out the other side, it will probably be a blocked or restricted - replace ... Air Conditioners

I am trying to get a user manual for my combi boiler,i do not know the make,it as on the front express ac30 combi can you please help thank you.