Having problems with your Air Conditioners ?

My indoor unit airconditioner located in my basement

\015 It seemed to be just dripping water so i cleaned it up 1 day while cleaning basement i noticed that alot of water was coming out the base. i pushed it with my hand and tons of water came out. why and what is wrong\015

Answers :

Hi, all a/c's produce water as condensation. Portables have a hose connector near the base. Wall mounted have a permanent hose that allows water to vent out. This pipe can get blocked by dust and fluff usually at the elbow joint. Try useing a small drain cleaning wire or extract all the water out ( i use a big syringe ) and put half a cup full of kettle boiled water in, or a drain cleaner. be sure to flush out well.\015\012Good luck. steve, UK

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

My indoor unit airconditioner located in my basement


Hi, all a/c's produce water as condensation. Portables have a hose connector near the base. Wall mounted have a permanent hose that allows water to vent out. This pipe can get blocked by dust and fluff usually at the elbow joint. Try useing a small d ... Danby DPAC10031 Air Conditioner

A/C Unit SAMSUNG -Outdoor unit model= MH080FXCA 4A was connected to 3 indoor units: · B location – indoor unit model MH035FNCA · C location – indoor unit model MH035FNCA · D location – indoor unit model AQV18JA (This unit has no rotary switch SW02, so I don’t know how to set it for communication with the outdoor unit) I set the outdoor SW01 to 3, because 3 units are connected of possible 4. I moved the dip switch of the outdoor unit to “off” position. I set the indoo


... Samsung Air Conditioners

Several years ago I purchased 2 Split-Type Room Air Conditioners--Models RSW-17 (Indoor Unit)/ROW-17 (Outdoor Unit) and RSW-12S (Indoor Unit)/ROW-12S (Outdoor Unit). The airconditioners themselves are fine, however,the Remote Controls for both these units, Model AR-DJ15, have gone bad and may not be repairable. How/where can I purchase replacement remote units? Alternatively, where/how can I send my remote units for repair? Chester D. Copemann [email protected] or [email protected]


Type in the mfg. name in the search bar and see if you can find resources. ... Air Conditioners

LG airconditioner LM-2166E2L Split unit. Indoor unit flashing 5 flashes after power surge. Indoor board was replaced , zener diodes were blown after surge.fault still remaining. Please advise James the fisherman


How do you shout it of ... Kenmore 6000 BTU Single Room Air Conditioner

When srart the unit from remote control 1)indoor unit running 3to4 min and then stop automaticaly. 2)i canot get 12vDC output for outdoor unit. this is mitsubhisi airconditioner please explain about this problem.


Its verry simple if your compressor did not run with in 5-10min it mean it has a defective thermal fuse....\012cos the thermal fuse is the protective current for the ciol winding of the compressor. ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

My LG unit cannot start. There is power going to the unit. i suspect it is the fuse in the indoor unit but I can't locate the fuse


Switch of the power. Lift front cover and unscrew seating cover and remove it. Remove your PCB and check where there is a 1.5mg fuse is there. Check for continuity. If not replace and check for loose wiring to find why the fuse blown. Thanks. ... LG LSC091PMA Split System Air Conditioner

I have a 2.5 ton ac outside. the indoor unit downstairs in the basement is a goodman. a new a coil was put in about a month ago. which is a goodman product. ive heard goodman is not a good product. a


The inside coil and outside unit should be matching in tonages another word if you have 2.5 ton outside the inside sould be the same. it don't matter what brand name or who made it. ... Goodman CKL36AR36 Air Conditioner

Is there a filter on the outside unit to be changed on model #38TZA036321? We know we have to change the indoor filters but unsure if there is one to change located on the outdoor unit. Recently bought the house and no guidance from previous owners. Thanks


No, there isn't anything to change at the outdoor unit.\015\012Best regards, --W/D-- ... Carrier Air Conditioners

Heat pump is 10 years old. No vibration sound in A/C mode. Loud 60 cps vibration sound in house near compressor when compressor is on. Compressor is not making a lot of noise when I open up the outdoor unit and put my hand on it. All compressor rubber mounts are tight and not broken. Looked for vibrations in copper tubing in the basement from the outdoor wall to the indoor unit. It is vibrating but seems loudest by the compressor. How can I isolate the source of noise?


Hi,\015\012\015\012\015\012Overcharged ? that's a possibility but also the vibration could be originating inside the heat pump - either at the main contactor or at the reversing valve ,or like I mentioned simply vibrating against the wood where ... Air Conditioners

A MITSHUBISHI PACKAGED AIRCONDITIONER MODEL:FDC71VNX FOR OUT AND INDOOR UNIT FDU71VD REGISERING ERROR ON THE WIRED REMOTE CONTROL INDICATING E 09,WHAT COULD BE THE FAULT?


... Air Conditioners

Hello, I need drawings for how to change motor on indoor-unit, AIRCONDITIONER Model; Fujitsu ASYB09LDC. PLEASE HELP ME. Regards VIK SERVICE Norway


Hi,\015\012\015\012Please try this document. \015\012\015\012http://www.tosh ... Fujitsu 24C1 Air Conditioner

Amana cool/heat unit PTH093B35AM gives error code F1, ( indoor ambient thermister reading out of range...... repalce thermister) I can't seem to locate a replacement part.


Fixed in the middle of evaporator coil. ... Amana PTH093B35AM Thru-Wall/Window Air Conditioner

Where are the air filters located on my 2005 Winnebago Journey 34H with Coleman Mach basement air conditioning unit (True Air residential air conditioning). I need to change them.


The filter is under the bed in rear. ... Coleman Mach 15 Air Conditioner

I have a Mitsubishi split system with 2 indoor units (MS09TW) and one outdorr (MU09TW). The evaporator coil on one of the indoor units has been diagnosed by a A/C repair company as having a pinhole leak. I would rather repair the entire indoor unit but I can't find an avaialable replacement unit. Is there a model that will directly replace my existing unit. The evaporator coil PN is E02 462 620


The following link includes service manuals for your air conditioning system: http://usa.mylinkdrive.com/uploads/documents/2388/document/MS-09~17TW,TN__MU-09~17TW,TN_Service_Manual.pdfI'm sure you find the solution inside the manual. ... Mitsubishi MS09TW Air Conditioner

The control for the compressor is not turning on when the remote is set on cool, but the indoor fans turn on. This is a C4822N outside unit and a RS 2422A twin indoor unit. there is 220 volt being sent down on black and white to the indoor unit but nothing comes back to the outside unit on red


... Sanyo Split System Air Conditioner

I purchased an Amcoraire split system unit for my 2 story garage. Licensced electrician did the wiring and licensed HVAC co. installed the 2 indoor units and outside unit. Outdoor unit is Model # AOM 243 HX 24000 BTU Indoor units are both Model #AWM123 HX, 12000 BTU each When I turn the unit on, it runs for about 60 seconds and then I get an error code on the inside wall unit that says P7. My manual says this has something to do with voltage. I had the power company come out and they show the


Since the manual says the error code has something to do with voltage it means the voltage is either too high or too low. And as the electric company says the voltage is within limits the the error is as a result of the voltage fluctuating. All you h ... Amcor Air Conditioners

Have a Multi Split Indoor unit ASU9RD - 2 units and Outdoor unit AOU18RD. Operation blinking GREEN; Timer blinking RED. Remotes not responding, Turn off units at circuit breaker, units still blinking the same. Both indoor units went down at same time. Had unit serviced in June 2010. What are the blinking lights telling us (Code)?


Hi.Here error codes:ERROR CONTENTS ... Fujitsu 12C1 Air Conditioner

I have a sanyo split air conditioner unit. The indoor unit is a rs2422b and the outdoor unit is a c4822. The #26 led is flashing which indicates a communication error between indoor's main and sub unit. I checked and cleaned all the connections. The unit worked for a couple days, but now I am getting the same error code. Is there a problem with the board in the unit.


... Sanyo Air Conditioners

Hi the outdoor unit turns on ( fan runs) the indoor unit does open, no heat or cold air blowing. In just fan mode the unit works fine etc speed setting ok. Its a sharp split type air model # ae-a244j outdoor,ay-a244j indoor unit what would be the problem, theres only two parts in the outside unit behind the side plate where the wires info is,small black box three wires and a round unit with wires. I hope this is help full cheers andrew


My gut says that this is evidence of a bad control board(circuit board). As usual, double check that your batteries are good in the thermostat. I have seen some weird things happen when the batteries are low. This one may be a job for your local con ... Sharp Air Conditioners

If indoor units power supply sopposed to be 220 and the output power supply going to the indoor units is 214, can the indoor unit work


Yes manufactures figure power to the unit can fluctuate 5% plus or minus. You are within 3% of stated voltage any higher may be a problem. ... Air Conditioners

I have carrier split unit the problem is the when switch it on indoor unit runs but when outdoor unit runs it make cool just for 5 mins and all unit indoor and outdoor go shutdown and green light start blinking and after 5 mins unit starts again after 5 mins again shutdown . any sugges please.


... Carrier 38CKC036 Air Conditioner

Uneven air distribution through indoor unit


You should remove the indoor unit and send the gas to outdoor unit and remove the pipe line and start cleaning it. ... Air Conditioners

I have a Sanyo Split System the indoor unit is a KHS0921 and the outdoor unit is a CH0921. When i first turn the indoor unit ON the fan will run for a few minutes and then go off. The outdoor unit never comes ON when there is a cll for cooling. The only way to get the fan to come ON again is to turn the breaker OFF and then back ON. The Operation loght will come ON when the fan is running but it will start flashing when the fan goes OFF. What should i look for?


... Sanyo Split System Air Conditioner

Hi. I recently installed 1.5 T, 3 * Split AC, LG. Whole day the AC works fine and no problem in cooling too. But once in 2 day outdoor unit start making thudding noise continously and does not stop for 4 to 5 second and after that indoor unit stops cooling and just fan runs. No cooling is done after that and room temperature keep increasing. The green LED of compressor in indoor unit is ON, compressor does not work. To achieve cooling again I have to switch off whole unit for like half an hour a


HelloSounds like the compressor is shuting down on high heat.There could be a couple reasons for this.1 Check that proper voltage is being supplied to compressor.2 Freon level may be low.This would be a service call.3 Ba ... LG Air Conditioners

I have a Daikin 2 x Daikin outdoor unit RZP125DV1 and 2 X Daikin indoor unit FHYCP125DVE - 1 for upstairs 1 for downstairs. On the upstairs remote controller i have got display "U4" (believe this means indoor unit not talkiing to outdoor unit) It works ok when Op Mode icon is on "fan".When I press "test" button code "5JC" displays. What does this mean ?


... Cfm Daikin R410a Split System Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0846 seconds