Having problems with your Air Conditioners ?

Why does the airconditioner keep turning off and giving the code C5?


Answers :

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Why does the airconditioner keep turning off and giving the code C5?


... LG LSC121PMA Split System Air Conditioner

My split system airconditioner made a bang when turned on and it threw the safety mechanism in the fuse box. When the safety trip was restored in the fuse box, the airconditioner displayed a code "CS" or "C5" (can't tell the difference). What does this code mean? My split system airconditioner made a bang when turned on and it tripped the safety switch in the fuse box. When the safety trip was restored in the fuse box, the airconditioner displayed a code CS ? Was unable to find any reference


Something has exploded. Look inside to see what it was. ... Air Conditioners

My Conia airconditioner keeps showing error code E3 and despite the power turning on nothing else is happening... I'm freezing!!! Thanks


... Air Conditioners

Panasonic airconditioner, keeps turning itself off, error code shows h-oo could you please inform me of sulution, thanks


Emergency operationPrimary location to verify\015\012H00 No abnormality detected - Normaloperation - ... Air Conditioners

Our airconditioner has the code C6 on it. It has cut out and displayed that code. We were instructed to turn it off at the power board and turn it back on, which we did. It went back on again and tried to work but it wasn't really cooling down the air and then after 15 minutes it cut out again and displayed the same code. We don't know what the code means as there is nothing in the instruction booklet which indicates any codes at all.


I previously asked you, if the C6 appear on the unit or on the hand held remote. I contacted a friend of mine who is a service technician for the LG Split System units and he advised that it's an error code that can only be solved by a LG trained ser ... LG LA185HV Split System Air Conditioner

Our airconditioner 5 way contol lights on the air conditioner are flashing and therefor the airconditioner won't turn on it keeps turing off. can you suggest a reason for it. the actual hand control does work and batteries are new. Thankyou...please reply soon as that our only way we are keeping warm!


Well i think problem with ur electronic board software..u have to put codes according to model no ... Samsung AS18A6RB Air Conditioner

Starway 3 phase air con shows e3 code when I turn it on & when its not turned on, I was told this is a voltage drop problem, can you please give me a list of the codes for future reference, thanks heaps, Debbie


... Air Conditioners

My split system airconditioner made a bang when turned on and it threw the safety mechanism in the fuse box. When the safety trip was restored in the fuse box, the airconditioner displayed a code "CS" or "C5" (can't tell the difference). What does this code mean?


It sounds like the compressor in the outdoor unit is shorted to ground. Checking this should probably be done by a qualified professional due to the dangerous nature of the high voltage that the outdoor unit uses. ... LG Air Conditioners

My panasonic cs-e12hkr airconditioner will only run for approx. 20 mins then always turns off and will not turn back on no matter how hot the room gets. I have the timer turned to off, but it still turns off after a short while every time. I checked for a fault code and got F95, with 18 beeps from the unit. It seems that the timer is set to run for 20 mins and will not alter or turn off. The timer shows 8.00 as a start time and no end time, even when turned to off.


My air-con will run for about 5 mins thens switches off with timer light flashing. i have tried to retrieve the error code but it doesnt work, not sure what Im doing wrong there. I have to reset the air-con for it to switch back on again but still wi ... Panasonic CW-XC243HU Air Conditioner

Furnace does not turn on from wall controller. If you turn unit off and on it will run for about 1 minute and then shut off never blowing heat. Was initially giving an error code of 31, so we replaced the pressure switch no help. Also replaced the module carrier, now unit does nothing. HELP!!!!


Hello my name is Heath it will be my pleasure to assist you. In front of the burners there is a flame sensor that has a wire attached to it you will need to take the flame sensor out and clean it with a piece of emery cloth or light grit sand paper I ... Air Conditioners

Well i have LG air condition and sometimes it working and other time the keep sending hot air while its in cold mood, and i change a motor in compresor but still it giving hot air and it keep on then automaticlly it turn off after that hot air, so what is a best solution?


... LG LS-L1210CL Mini Split Air Conditioner

I have a Carrier model # 58MXA080-F-15112. I think my furnace is 30 plus years old. it isn't heating properly. The blower turns on and sometimes the flames come on, but sometimes they don't. As a result, the temperature just keeps dropping and dropping in the house. A furnace repair technician has been out twice. The furnace was displaying code 13. He replaced the limit switch and a another switch, but I'm having the same problem, but with no current code on the furnace. Any ideas?


A 13 code means the furnace cycled on limit more than three times consecutively and is in a lockout for 3 hours. A 14 is ignition lockout. An ignitor does not intermittently quit working. I'm the service mgr at our shop, and I know that particular fu ... Air Conditioners

I have a DeLonghi CF210 and I'm getting the "E3 Fault" code on the main screen. It will not power up in Air Conditioning mode, but the fan mode will run. I saw where someone suggested it is a voltage problem, and have tried it in several outlets to no avail. This problem happened to me about a week ago and I turned it off for a while (10-20 minutes), then turned it back on and it worked again for a week before giving me the E3 Fault error today. I do not have the financial resources to sen


Remote controller comms error. Check wired correctly, if so check dipswitch in RC. Set to Sg for 1 unit, or Gr for group then reset power ... DeLonghi CF210 Portable Air Conditioner

My airconditioner, a Kelvinator inverter split system keeps showing P4 and won't respond to a remote to turn it on or off!


... Air Conditioners

ERROR CODE ON AIRCONDITIONER LG ART COOL INVERTER MODEL NUMBER LSZ244VM4


Hi,The first thing i'll say is you will need to get it repaired by a technician and i strongly recommend you not to do it by urself.Remote control units have diagnostic program in the ... LG LSC183VMA Split System Air Conditioner

Have a ILE vulcan central heating gas system. ignites and runs for about 3 mins, then turn off and keeps cycling like this .LED flashes a sequence of solid and erratic codes.


... Air Conditioners

Hello have a inverter LG Airconditioner and it keeps turning itself off and showing the letters C6? Any ideas


Error Code: C6 Problem: Inverter compressor run current high\015\012SOLUTIONS:\015\012- check [resistance of] compressor windings all equal 1 to 4 ohms\015\012\015\012- check [resistance] to earth 50 Mohm minimum\0 ... LG Air Conditioners

I have a clausen portable airconditioner model number KYR-44/ it keeps coming up with E4 and turning its self off


If unit displays "e4"1? Check whether the winding resistance andoperation current of the compressor are normal.2?Check whether the high and low pressure is normalwhen the unit is running.3?Check (whether the coil p ... LG Air Conditioners

My samsung Split AC has some red light blinking along with a green one and its giving a different sound when i turn it on and the air/cooling does not come. It stays numb and the light keeps blinking. I tried fixing it by taking out the main plug and connecting it again but of no use. How do i get my AC started?


... Samsung Air Conditioners

Have a clausen portable airconditioner model number KYR-44/B need to know mode settings and it keeps coming up with E4 and turning its self off


... Air Conditioners

I have 2 seperate controls ,1 for heat the old honeywell round turn styls and then i bought a new digital thermostat ritetemp and i have 3 wires for the airconditioner white,red and green, i just cant figure out how too hook it up it has so many pins in it give me some help please!


On the round its r g w hook that on the new stat if your using it for heat to then the rh and w are heat controlling baseboard or a boiler relay? the new stat has a jumper wire remove that it is hooked up to rh and rc un plug every thing good luc ... Intertherm P3RA-048K Air Conditioner

Ihave a l.g. lsu242he unit that is not working. The diagnostic light is fluttering and not giveing any code. Board has been replaced to no avail. Replaced board on inside unit. no change. condensor fan runs evan if inside unit is turned off. This unit ran perfect for aboutone month


Sounds like some of the low voltage wiring has shorted out. This will make the light flutter like that and will make the condenser fan motor run as well. If you replaced the boards and are getting the same issue, then the only thing is can be is a ... LG Air Conditioners

New airconditioner (installed 5 days ago) not working. Turned it on for first time (after installers's demo)yesterday, left the room after it had been running about 30 min. Returned within 10 min to find it had ceased functioning, timer light flashing orange, power light no longer illuminated. Followed procedure in booklet (flashing power light indicates fault) and error code F99 came up. What can I do (I'm waiting to get intouch with after sales service.)


Do nothing on a brand new unit but let the installer or service tech fix it for free, if you go messing with it you may camoflouge the real problem and when the repair tech arrives he wont be able to observe the actual cause or fault and it will do i ... Panasonic Air Conditioners

HAVE A DIMPLEX PORTABLE AIR-CON HAD IT FOR 6 MONTHS . LATEY WHEN YOU TURN IT ON AFTER 5 MINS IT BEEPS AND THE CODE E7 KEEPS FLASHING. CAN NOT FIND THE MANUAL SO DONT KNOW WHAT IT MEANS..PLEASE HELP


The E7 message indicates that the unit is full of water and needs to be drained. The drain plug is on the back of the machine towards the bottom on the right as you face the back of the machine. You can empty the unit by pulling out the black ... Air Conditioners

Danby dpac120068 blue light flashing with error code E04 and the compressor keeps turning off randomly. What is causing this? What does E04 mean?


Hi,E04 refers to Overheating. There might be plenty of reasons. You might have seen, if you shut down the ac for few minutes and again start it, It would work for few minutes and the same E04 display is there.This is tech's jo ... Danby DPAC120068 Air Conditioner