Having problems with your Air Conditioners ?

High Pressure Shut Down

\015 I have a UAMB-042 JAZ unit. Sometimes the A/C will kick on and within several seconds the outside unit will stop and the inside unit will keep running. If you go outside and push the high pressure reset button the unit will start and continue to run. I have had it cleaned and checked for freon. They also changed the fan motor and drained the freon to see if the expansion oriface may be clogged. The unit still has the same problem. The problem is intermitent and hasn't occurred with gauges attached to troubleshoot. Any ideas or help are appreciated.\015

Answers :

Hi,\015\012 If the outside fan is running when this takes place and the condenser is clean, I believe its the High Pressure Control that is bad. There is a possibility that if the unit was opened and air was allowed to get into the refrigerant part on the system that it could cause this problem but unless the system was worked on just prior to this starting, I don't think this would be the case. The part about draining the freon to check the orifice doesn't sound right, This could be done with a pump down by closing the suction line valve at the condensing unit which leaves the freon in the condensing unit. If they charged you to replace the freon, I would question them about this procedure. Hope I have helped.\015\012kstfas

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Air flow indoors good.I cleaned condenser, found outdoor TXV not responding, Tested sensing bulb w/Heat&cool. M#-UFMAo36jaz 1995. In the cool mode temp. & pressure was good.But in heat mode pressures were within three PSIG of each other and compressor would shut off on high thermo. What is your suggestion


SOUNDS LIKE THE COMPRESSOR S NOT KICKIG IN OR THE REVERSING VALVES NOT KICKING IN.. ... Ruud UBHC Air Conditioner

High Pressure Shut Down


Hi,\015\012 If the outside fan is running when this takes place and the condenser is clean, I believe its the High Pressure Control that is bad. There is a possibility that if the unit was opened and air was allowed to get into the refrigerant part ... Ruud UAMB Air Conditioner

Do the H series Hayward heaters have a low water pressure shut off valve and or a high temp limit switch?


Yes..... they have both. The limit switches are located near the inlet/outlet water manifold. The water pressure switch can be found from the front of the unit. Find the device at the end of the 1/4" copper tubing. It will have 2 wires connected to ... Air Conditioners

I have a Carrier HFC-134a commercial chiller unit model 30HXA076RY-561AA. It runs 2 sides which are labeled A1 and A2. Over the past few weeks now the A1 side keeps shutting down (almost daily sometimes more often) with an alarm that says "A1 Failure - High Pressure Switch Trip". We've had a local hvac company come in to look at it a few times... One of them they were here for nearly 2 full days. They replaced some filters and did some diagnostics... Racking up a huge bill... But haven't solved


... Air Conditioners

New heat pump amana asz 5 ton. cooling works perfectly, heat pump shuts down on high pressure? any solutions


Ck your inside are flow filters vent dan ... Amana Air Conditioners

Uamb 060Jaz condeser unit shuts down press high pressure switdh turns on again for a few days than same thing again


... Ruud UAMB Air Conditioner

We had our furnace replace this winter, our air was only about 8 years old and working fine so we didnt change it, well now , the air coming out of the vents are cold, but the condenser NEVER shuts off and the thermostat never reads what it is set on, it stays 2 or more degrees higher, the company that installed the furnace checked the air and said everything is working fine, and leaves me high and dry and HOT... the freon level is good, the pressure reading is good, but the house is hot and the


Hi, if the new furnace they put in did not have the right size coil to match the outdoor unit, it would run all of the time and not cycle off. Lets say if it is a 3 ton condenser, the indoor coil must be a 3 ton coil as well. If they put a 2 !/2 coil ... Air Conditioners

What should the high pressure line read to be fully charged on my RUUD UAKA-042 a/c unit? The specs on the unit has a design pressure of 300 PSI on the high pressure line and 150 PSI on the low pressure line. Is that the operating pressure for the high pressure charge or the maximum value that the system can with stand before rupturing a line or component?


That is a desing pressure not an operation pressure. opperating pressuers will vary with load so pressure alone will not tell you if you have the proper charge. the proper method is with superheat or subcooling, depending on the type of metering devi ... Ruud UAKA042 Air Conditioner

Extremely high head and suction pressures


Disconnect the blower and turn on the ac.see if the coil frosts evenly.when you had the system open,you should have changed the liquid line drier. ... Air Conditioners

1994 corolla-I charged the air cond., and it was cooling fine. After about a mo., it was not cooling very good. I assumed it had a small leak. I put my guages on it and the low pressure was running 15 to 20. The high side was reading about 150.I put a can of stopleak and detector in it. Then I put a can of freon in it. While I was putting the freon in it the pressure started to drop on both the low side and high side. Now the low side pressure is running about 15 and the high side is running 0.W


Hi\015\012\015\012\015\012Thanks for using FixYa. This has happened because of the low side pressure on your AC pump isn't kicking on, because when the pump is off, the pressures equal out and the low side shows a high ... Air Conditioners

Heatline boiler pressure is very high, exceeds normal pressure (arrow is shacking at level 4 which makes a lot of noise). By opening tap in the bathroom, lowered the pressure down to 3.5 (noise is vanished but there is still a high pressure).How to low a pressure down? Heatline boiler is turned off.


... Air Conditioners

Rheem split system condenser high pressure limit/safety needs resetting frequently before it reaches the set temp of 76 degrees faren. what's wrong and what do i need to check?


... Air Conditioners

High Pressure cutoff


YOUR OUTDOOR FAN MOTOR SHOULD NEVER SHUT OFF IN THE AC MODE. IT IS SUPPOSED TO SHUT OFF IN THE HEAT MODE WHEN ITS IN DEFROST. IF THE UNIT IS RUNNING IN COOL AND THE OUTSIDE MOTOR QUITS ,THE COMPRESSOR WILL QUIT SOON AFTER. EITHER THE RUN CAPACITOR FO ... Air Conditioners

Ruud uprl-036jez is tripping on high head pressure. Indoor coil seems to be clean, filter is clean. ref charge is good. Indoor txv was replaced. Fan is on high speed. Hooked up to a 10yo olsen direct vent oil furnace with direct drive blower. This coil is on the return. I have another hp, same model number that is on another oil furnace buts its on the supply side and its doing the same thing but doesn't always trip. The pressure goes really high and then it just drops back to normal. Neither un


Check your TXV outside just like you do inside. Strap temperature sensor to outlet of TXV, disconnect the bulb.and let run 5 min, Get temperature reading, then put the bulb in your hand and watch the bulb open up. Next stick in a cup of ice water ... Air Conditioners

A/c switch I am trying to find out how to replace the high pressure switch in my, RUUD central A/C unit. The system is empty, as the high pressure switch was leaking.I am having trouble where the copper line, on the switch, goes into the high side line. I can see it is not soldered.Do you need some kind of special tool and if so how and where I can buy one. Thank's for your HELP!!!!


If it is an AUTO RESET pressure switch you can use wrench to remove it. ... Ruud UBHC Air Conditioner

In 30gtn,gtr040-420 ther have error cod 51(High-pressure or loss-ofcharge


... Carrier Air Conditioners

Low Pressure reads HIGH. High Pressure reads LOW??? Not cooling much.


Stuck in heat mode \015\012\015\012tap on reverse valve lightly ... Carrier 38CKC042 Air Conditioner

I have a two and half ton heat pump, works perfect in cooling. when in heat it trips high pressure switch whitch locks out cond. for a couple min then runs for about 30 seconds and trips on high pressure again


... Air Conditioners

I have high head pressure and high suction pressure?


This is usually a sign that the system is over charged but can also be the compressor going bad or a restriction in the copper line set. I would start will the easiest and go for the refrigerant charge. Hope this helps! ... Air Conditioners

Hi there, iwant some help in duct type air condition (trane)60000 BTU .when i was gave the out door freon i recognized that the high pressure fans were off and the compressore was on ,so i turn off the air condition for seconds then turn on i found that the high pressure fans run for one minute and then turn off and the compressore still running ,so what i shell do????


I hate to say this but it sounds to me like you need a professional. You may hear some other advice but it's not safe for anyone to work on the outside compressor unless they really know what they're messing with. The fire and death by electrocutio ... DeLonghi Trane 5t Rooftop Air Conditioner Ycy060g1m0ad

I have a 1993 yellowstone camper with a coleman wall thermostat. on the bottom of it- it has a heat/cool switch on one side and the other side has a low-high-fan switch. when we run it on low or high it gets cool but the fan never shuts off.if we put it on fan it shuts off with the compressor but it doesn't blow cool air. any advise?


Thank you so very much for your answer! I'm glad I came to this website before I began a new project. I was about to re-wire my unit based on my ex-husbands advice!!!! ... Coleman Air Conditioners

I have a Tane 2 ton condenser unit that has high head pressure(290) and high suction pressure(150). The unit is properly sized but no cooling. Unit has been installed probably 4-5 years and has not been run for over a year.


Has anyone added some freon? The unit has way too much freon inside it. You need someone to reclaim the freon and weigh in the right amount of freon. If you run the unit the way it is will cause some very serious damage. Let me know ken ... Air Conditioners

Low pressure reads High. High Pressure reads low???


Your gages are hooked up backwards, try switching them ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

Insufficient cooling in my mercedes 300e 1989. When i hook the manifold gauge and turn on the AC, the low side pressure shows ~70psi and high side 200 - 230psi(low side pressure stays constans and high side not to)


1989 year would indicate the system uses the Old CFC R12 refrigerant. 70 PSI equals about 70°F . This is not enough pressure difference to give you any cooling. Sounds like your compressor has bad valves. Replace compressor. ... Air Conditioners

When i was tested an air condition (trane 60000BTU duct type )i noticed that the high pressure fans of the out door unit were turned off and the compressor was running ,so i turned off the ac from thermostat for a second then turned on ,and look for the out door unit. I discovered that the high pressure fans turnned on for a one minute and then stopped, but the commpressor still running . What should i do ???/PLZ


... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"