The fan in the outside part of my AC doesn't run

\015 When I open my LG, the fan in the outside part of my AC doesn't run. The inside part provides some air for few minutes and then my breaker overloaded and turned off. Is is the fan on the outside part that is the problem???....What can I do to resolved it?\015

Answers :

If it is the compressor at fault it will be at the discretion of the manufacturer as to what they replace. I would suggest you contact an aircon engineer who can help you diagnose the problem because a professional will have to be in touch with the manufacturer. As you are getting in touch with the contractor who supplied the equipment that will be the correct route to go. Hope this helps.
On most air cons there is a time delay before the outside unit starts and LG are no exception. This function means that erratic power supplies wont kill the compressor (outside bit). If the internal fan runs for a few minutes and then the trip goes then it sounds like you have a faulty compressor. This tends to be a scenario for a failed compresssor. What you can try is putting the unit on FAN ONLY (no cooling) and see if the power stays on. \015\012\015\012If you are more technically competent you could isolate the power to the compressor on the external unit (AFTER ISOLATING THE POWER TO THE WHOLE SYSTEM). And then try putting it on cooling to see if the external fan works. If the trip is not thrown then you have a faulty compressor. \015\012\015\012I would also like to point out that most A/C manufacturers offer a three year parts warranty so you may have some sort of cover depending on the age of your unit. In which case get an aircon guy out who knows what they are doing (personal reccomendation is always a good starting point).\015\012\015\012Hope this helps.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

KELVINATOR KSR20C Our split systeme air con does not heat or cool the outside fan run when on but the inside fan doesnt run the little led on the circuit board on the outside unit is blinking on for 3 sec ond off for 3 sec do these air cons have a fault codes ??


One might think so, YES! look on one of the door panels that you can remove! Thank-you-very-much! ... GE Zoneline AZ38H12DAD Split System Air Conditioner

The outside unit is no0t able to start the fan spinning on its own. I have been able to manually engage the outside fan by turning the unit off, turning it on, and then manually spinning the fan when it starts up. The unit will then engage the fan and runs fine until the next cycle when it cannot start the fan on its own again. Can you tell me what part needs to be replaced and about how much it will cost?


Hi!!\015\012\015\012The part you need is called STARTING CAPACITOR and it is located in the same compartment where the electrical connectors are in the outside unit. MAKE SURE THE POWER BREAKER IS OFF before opening the compartment. and befor ... Air Conditioners

The fan in the outside part of my AC doesn't run


If it is the compressor at fault it will be at the discretion of the manufacturer as to what they replace. I would suggest you contact an aircon engineer who can help you diagnose the problem because a professional will have to be in touch with the m ... LG LS-L1210CL Mini Split Air Conditioner

I have an Interthem / Nordyne heat pump model E2EB-015HA. On the outside unit the fan does not turn on when the unit comes on. If I spin the fan it will come on and will run well. With the unit off the fan blades spin easily. I suspect the capacitor, but can not find a part number for it. The capacitor itself is rusty and any writing is unreadable. Please help.


Not sure what Country you're in but the Part No for the Run Capacitor is 1499-4461 and can be purchased from the following link.\015\012\015\012htt ... Air Conditioners

Hi the outdoor unit turns on ( fan runs) the indoor unit does open, no heat or cold air blowing. In just fan mode the unit works fine etc speed setting ok. Its a sharp split type air model # ae-a244j outdoor,ay-a244j indoor unit what would be the problem, theres only two parts in the outside unit behind the side plate where the wires info is,small black box three wires and a round unit with wires. I hope this is help full cheers andrew


My gut says that this is evidence of a bad control board(circuit board). As usual, double check that your batteries are good in the thermostat. I have seen some weird things happen when the batteries are low. This one may be a job for your local con ... Sharp Air Conditioners

I have a goodman spliit system clj42-1c. Outside fan does not run. I removed it and gave it power and it came on. Then with fan removed I powered up the unit the compressor hums for a minuite then cuts off but it never seemed that it was realy working. Thear is freon in the system. I need to know if the capasitor is at fault or if the compressor is bad. I am an air craft tech so I have a multimeter and enough know how to find the problem. I just dont want to purchase the wrong part. Can u tell m


If your multimeter has a Capacitance Meteryou can test the capacitor. There are ways to broadly test a ca ... Goodman CLQ36AR49 Air Conditioner

Sometimes, when the inside blower shuts down, the outside compressor and fan motor continue to run for some time. Other times, when the inside fan motor is running, the outside fan and compressor motors are not ... if I press the outside reset button, it starts up When both inside fan motor and outside fan and compressor motors are running, it works fine ... warm air blows out of registers. Other than that problem, both units work great!


Sounds like you have a dirty condenser. You are going to need to disconnect the power at the outside unit on the wall by pulling the fuse block out. Take a good look at the louvered covers that are attached to the outside of the unit. Remove the scr ... Ruud UAKA060 Air Conditioner

I have a Coleman 5T 13 Seer Heat Pump. When the unit is running there is a lot of vibration (outside unit) and I hear a tinny sound (possibly like the fan hitting something). This seems to be worse during the hottest part of the day. When the unit had its last service they said it was low on freon and recharged it and it seems to be since then that the problem has occurred. Is it possible that the unit is overcharged? And if so is this dangerous, i.e. could it cause permanent damage or immi


I have a coleman mach roof air on the RV. It keeps blowing the 3amp fuse. Why?? ... Coleman Air Conditioners

I have an goodman model # gsc130241ae ac unit outside it will not come on, no hum, fan doesn't run thermostat control is good swaped out with downstairs unit. Gas heat unit is in the attic, I don't use this part of the unit during the winter because this is the #2 unit for upstairs. Downstairs unit works great circuit breaker is on


Does the blower indoors run and move air? if not it would mean that you don't have power to the furnace.\015\012The 24 volt transformer in the furnace is used to power the thermostat and the control circuit on the A/C unit outdoors. Or you coul ... Goodman CLQ36AR49 Air Conditioner

I have a Goodman Model number AR24-1 unit and the blower moter will not start with it turned on to fan or cool or heat. I have checked the thermostat and the unit runs outside. Just no blower. Can I jump the blower motor as I replaced the capacitor today. Hear are some numbers that may help. Part Number #15212-50 Volt 208/240 Amp 1.5 HP 1/5 No heat Kit It has a Goodman switch board # B1370735 that I can check with my meter if needed. I have checked the thermostat in the attic also. Seems like


... Air Conditioners

If the weather outside is cold and you are running the heatpump/aircondition. Is the fan motor on the outside suppose to stop running. I notice the there is heat coming from the unit after it as been running awhile but the fan is not running


Yes the fan will shut down during the defrost cycle. But the fan only shuts down during this cycle....other than defrost the outdoor fan motor should be running during a call for heat. ... Amana Air Conditioners

Rudd heatpump compressor runs outside fan dose


I don't think the fan on it' own crates the problem. Could you find out what should be and what actually is the flow through it. If you needed <!-- MOJAIZBA.COM LINK CODE START -->\015\012<a rel='nofollow' href="http://mojaizba.com/convert-u ... Ruud Air Conditioners

I have a goodman cpk j42 -1b ac unit on the outside and a central heat and air unit inside. the ac unit come on and runs fine but when it hit the temp the thermastat clicks and the fan outside goes of but the one inside stays running and will not turn off unless i hit the breaker. is it he fan relay at the outside ac unit?


Hello BWOOD Check the thermostat FAN button is in AUTO position not ON position.That might be it .The relay is in the blower unit but they RARELY become frozen/welded stuck on. ... Air Conditioners

My 38CKCK24330 Unit stopped running, it will try and turn on every 10 or 15 mins you can here it outside buzz, I looked outside at the unit and the fan is not running. The system has power, the breaker switches are working, the furnace turns on fromt he attic. What do I need to trouble shoot, someone told me to check the switch on the unit by pressing it in to see if the fan will turn on once the button is pressed in. I did this but the fan did not turn on. Any help would be appreciated it, I


Hi angelagaddy,With the fan not running and you are hearing a buzzing noise outside this is more likely that the fan motor needs to be replaced or the capacitor ... Air Conditioners

Turned on AC was running fine. 30 minutes later began to hear a strange noise. Opened AC/Furnance closet & heard a sound best described as air letting out of a tire. It seemed to be coming from copper pipe. Minute later sound stopped & air was suddenly hot. As if AC was turned on fan not cold. Went outside & neither fan nor motor was running. Turned fan manually. Ran for about a minute then stopped. Outside unit was making what could best be described as a buzzing sound.


Hi!!\015\012\015\012This means that the condenser fan motor (outside unit) failed, this caused to build hi pressure and either activated a safety valve to release the extra pressure or blew a line and R22 Refrigerant escaped from system. ... Goodman CKL42AR42 Air Conditioner

My compressor unit outside runs and cools Freon but the inside blower has a problem running. the model # is 2TEE3F31A1000AA. The fan control, in fan run control mode, shows a bright green for the fan LED and the CFM selection LED varies with the rotational speed of the fan. The motor tries to start showing , initially, a jerky back & forth movement. It squeaks some and may, or may not, start rotating. If it starts the CFM LED goes bright/on no flicker and the motor runs briefly (5 seconds) then


Hi, from what you have told me, you are loosing the bearings in this blower motor along with windings. This motor is rubbing the blower housing, tight when you turn it, and when it jerks when it tries to start tells me that you have burned or very we ... Air Conditioners

Outside fan not running, inside unit running fine. Compressor was running this morning, but no longer. Replaced fan motor, turned power back on, now fan or compressor not running. What else can be checked?


Hi,\012There may be a manual reset high limit... look for a red button on a round part hooked to the small copper line and push it in hard...\012Also the compressor may have kicked the overload and needs a few hours to cool and it reset, ... Goodman Air Conditioners

Airhandler fan runs and outside fan motor runs air handler lines


Low refrigerant will cause this issue, as well as plugged coils, and a failed compressor.\015\012Without gauges, all you can do to leak check is to examine the inside and outside coils for oily spots, indicating where the leak likely is. If yo ... Goodman CKL60AR60 Air Conditioner

When the unit is in heat mode is the fan on the outside supose to run? Capacitor on outside and inside have been replace fan was running when capacitor was first replaced.


Hi, and the outdoor condenser fan should not be on at all in the heat mode unless this is a heat-pump!! So, I can see that this is a 3-ton Carrier split system and I haven't pulled up any information on it, only if I need to. But if the indoor unit r ... Carrier 38CKC036 Air Conditioner

Goodman heatpump model cpke30-18 installed new in 1997. just replaced the condenser motor. new fan runs cloclwise but the fan blade is for counter clockwise. it is blowing down not up. part house said that i have the correct part. old and new parts do match up. has three wires yellow - cap, black-motor starter and purple to control board. is there any was to change direction of motor. also the new fan does have a arrow for counter-clockwise direction. thanks


Does your new motor have two sets of short wires with connectors in the middle of them? If so then it is reversible and the instructions for doing so are printed on the motor data plate on the side of the motor.If it does not have these wires then re ... Air Conditioners

Run capacitor Hello, my blower fan on the outside isn't working but, the indside blower fan is, so, if the run capacitor is bad will the blower fan on the inside still run? Thanks


Yes....they use seperate capacitors. ... Air Conditioners

The outside unit on our Ruud heat pump won't turn on. The inside fan blows but the unit outside sits idle - no fan turning, nothing. It was cooling earlier today, but when I came home from shopping, the house was warm, the inside fan was blowing, but the outside unit is silent, not running.


First look for red button neer the copper line set if has one push it second inspect thermostat wires for weed eater damage check disconnect for fuses check breaker at main panel pull disconect and remove cover check stat wire connections look at the ... Ruud UPMC036 Air Conditioner

Air Conditioning I have a ruud system with the air conditioner outside and the air handler upstairs in the attic. My systems appears to be running, and I can feel cold air at the vents, but I can barely feel it. Like there is no flow. The fan outside is running and the unit in the attic is running. I have no clue what the problem is. The large coil coming from the heat pump outside is cold and has condensation on it. It also seems to have a little ice. It has been extremely hot here in Ge


Open the access panel on the air handler in the attic and take a look at the evaporator coil. If you have no airflow, and you just changed the air filter, then you probably have a buildup of airborne crud on the coil that's blocking airflow. \015\01 ... Ruud UAKA030 Air Conditioner

Weather king model 13pja36a01 Heat pump The outside fan runs slowly, compressor starts then immediately stops. I replaced the run capacitor, I believe this might be the fan motor going bad but I can't tell. Could I test the resistance of the fan and what values should I get? Where can I find a replacement fan? Thanks Tom


If you have replaced the run capacitor and the fan still is running slow you definitley need to replace the motor no doubt. you can go online to Grainger.com or find one by your house. Your compressor is going off immediately because high pressure th ... Weather King 10AJA3601AH Air Conditioner

About to weeks ago my outside compessor and fan were not kicking on and the indoon furnace fan was running constantly i figured out were the voltage stoped and i reset the high pressure switch. the copressor kicked on right away. for about four or five days now the inside fan in the furnace runs consantly and the copressor keeps kicking on randomly as well as the copressor fan but it only stays on for 2 to 3 minutes then kicks off my thermostat never kicks off and the temp. inside my home neve


Hi,Sorry you are having trouble, with summer coming on we will need the cooling. Thank you for the details it helps a lot. I think we can safely eliminate the thermostat, the fuses, the controls from the furnace (air handler) ... Air Conditioners