\015 1. it was making some loud noises and then stopped. now it blows hot air but when the thermastate is turned up to cool it tries to turn on but can't. so all i get is hot air. 2. on second air unit, there's water not ice just cold water built up on the inside fins behind the filter and it is constitently cutting on and off when on power saver. it does cool somewhat.\015

Answers :

Where is the air filter for the ruud ( #uak037jaz) air conditioner
Hi, Give the first unit about 15 minuets and try it again. The pressures have to equalize it the system before it will restart each time the compressor kicks off. The second one sounds like its doing what it needs to do. There should be water on the fins but no ice.\015\012Hope this helps.\015\012kstfas

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

KELVINATOR KSR20C Our split systeme air con does not heat or cool the outside fan run when on but the inside fan doesnt run the little led on the circuit board on the outside unit is blinking on for 3 sec ond off for 3 sec do these air cons have a fault codes ??


One might think so, YES! look on one of the door panels that you can remove! Thank-you-very-much! ... GE Zoneline AZ38H12DAD Split System Air Conditioner

Working on a heil m#gde075b12g1 downflow when thermostat is satified everything turns off except blower keeps running to a point where it starts to blow cool air. doesnt do it all the time checked limit switch ok checkedall switches ok need to turn off power to stop it .


Hello, sometimes this can happen if the relay on the intergrated contol board sticks, Im assuming the blower off settings are correct since this happens intermittently. When this happens again try tapping the relay with the handle of a screwdriver an ... Air Conditioners

This is a heating and cooling through the wall heat pump. It works normally when heating is selected - the heat pump runs and both speeds of the fan blow warm air. But nothing runs when cooling is selected. In other words the unit works normally when "High Heat" or "Low Heat" is selected but nothing runs when "High Cool", "Low Cool" or "Fan Only" is selected. The position of the Fan Cycle Switch has no effect - behavior of the unit is the same in both positions of the Fan Cycle Switch.


You have a bad board or bad switch. I would say board. You can have service tech check this out. There is only so far you can go without knowledge of Controls ad electricity. Russ ... Air Conditioners

Fedders Model No. A7U12W2A-A, 12000btu airconditioner. The unit has been cooling satisfactorily for two to three years. Today the unit was cooling and suddenly there were a couple of reasonably loud knocks and the compressor stopped cooling. The fan continues to run. In about five minutes the cooling comes back on. The compressor runs for abut four minutes and shuts down. Earlier today we had a power dip without losing all power.


Hi, the power dip when translated means low current actually affected the relay starter which is situated beside the compressor. Now the relay starter works and stop intermittently which is why the Compressor cools whenever it works and does not cool ... Fedders Air Conditioners

Air conditioner runs for a few hours and it works - it cools the house. Then it stops cooling - the fan still runs but it doesn't blow out cool air any more. It seems like it's overheating or something. It will blow out cool air if it has not been turned on in a while but once it's on too long it stops. I was told it could be the fan motor and the a/c guy changed the fan motor today but that didn't fix the problem. Now he says it might be the compressor or that I need a new system. I'm jus


The things I would check:\015\012Is the system properly charged with freon? Sytem may be overcharged.\015\012Is the compressor out on internal overload at the point of failure? If the overload isnt tripped and the compressor is having tro ... Air Conditioners

I have a 8 years old window ac. It's working quite ok. I just want to know which mode is safer low cool or high cool when humidity is high but temp. is about 32-34 degree celcius. Technican advised me to run in high cool mode for some time n then switch is off, but i want long hr. running in low cool mode which is quite comfortable. Kindly advise.


Its not a mater of safety. Its only a matter of witch is best for you. If you want to maintain the temp then leave it on low temp. If you want to save money then you can switch it to power saver mode on high to bring the temp down. Hope this helps. G ... Air Conditioners

Fan Runs, AC Doesnt, Blinks 5 times


Need to look around and should have an error code and give more detail of what the problem is. If you post that i can maybe help you more. I need to know...... ... Dometic Rooftop RV Air Conditioner

19 seer infiniti system, system will run for 2 mins. and then cut off and it will not show a code to the outside unit board or the thermostat. Replaced the thermostat and the outside low voltage wiring, then went to test mode on thermostat. Turned high cooling for 15 mins, it will run for 10 mins and then cuts off. It still does not show a code. If you go to the thermostat and turn it off, and reset it to cooling it will run for 2 mins and will cut off.


This cut off is very likely being caused by a defective compressor module thermo limiter (prevents overheating the compressor), replace it. ... Air Conditioners

1994 corolla-I charged the air cond., and it was cooling fine. After about a mo., it was not cooling very good. I assumed it had a small leak. I put my guages on it and the low pressure was running 15 to 20. The high side was reading about 150.I put a can of stopleak and detector in it. Then I put a can of freon in it. While I was putting the freon in it the pressure started to drop on both the low side and high side. Now the low side pressure is running about 15 and the high side is running 0.W


Hi\015\012\015\012\015\012Thanks for using FixYa. This has happened because of the low side pressure on your AC pump isn't kicking on, because when the pump is off, the pressures equal out and the low side shows a high ... Air Conditioners

1996 Coleman Model 7333C8876. Have 2 units on our Motor Home one day it was hot so I had both units running controlled by a Electronic Climate Control system. It got cool in the evening so I turned them off. The next day when i fired them both up on high the rear was fine. But the front will only cool on Low. The fan will not run on high and you can hear a slight noise coming from the unit. But the fan will not run on high.


Check to make sure the drain tube is clear. It sounds like the blower fan is dragging in water buil-up. ... Air Conditioners

I also forgot to add in my last question that when its dry the AC will run cool and we are able to get the house down to 82the degrees. Only when it's humid does it not work right. Its not always cool usually when everyone is home we run it its usually over 100the and we kick it on to82 it will cool the house down then when it kicks off it blows room temperature after that.


In dry mode the compressor on and off frequently. If you want full comfort keep it in cool mode. ... Air Conditioners

A/c will not continue to cool.. Starts fine, runs fine.. but shuts down cooling ( comp shuts off but fan still runs) after anywhere from 5 min to multiple hours. No circuit breakers or fuses blow. CAN usually reset by cycling wall thermostat if that does not work can unplug 12v. connection to thermostat and it will most often start cooling again when asking via the thermostat. Have replaced computer board in a/c unit on roof and wall thermostat


One amateur test is to place your hand on the compressor and see if it\015\012is too hot to hold your hand on it. You may have a restricted condenser coil \015\012If it is too hot then the condenser coil is restricted inside the unit ... Dometic Rooftop RV Air Conditioner

I have a carrier Modle No. 38YXA042300. I am getting an H5 error message on my Thermistat Control. I have run the Fan only mode and the fan in the air handler unit works fine. On the unit when I ingage the manual override, the condener unit and fan motor runs and cools. The unit will not run when I put the Thermidistat on Cool mode. Can you help me. Andrew Construction Mangement Speicalthes, Inc.


On some carriers they have a lock out feature outside to reset shut down power to furnace for 90secs. and then restart ... Air Conditioners

I have a duo therm a/c roof top unit that is not cooling properly it has been approx 2 years since the unit has been run I have checked breakers and fuses in breaker box I removed the cover from unit the compressor is running and getting hot the lines are cool but not cold the fan is running I am thinking that the unit is low on freon can some type of self tapping ports be installed to add freon or have ports soldered in place or could there be another underlying problem that can be checked or i


You have a leak in the system that needs repair. If you have to add freon to system there is a leak. You need a service tech to do the repair. If it is out of gas you may to replace it. Leaks do not correct themselves. Russ ... Dometic Rooftop RV Air Conditioner

Trying to cool but units run and run and run.


It sounds like you maybe low on freon ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

HAVE A COLEMAN MODEL DRHSO601CB --- THE UNIT WILL RUN FINE FOR SEVERAL HOURS WITH GOOD COOLING AND THEN PERIODICALLY THE TROUBLE LIGHT WILL COME ON THE THERMOSTAT AND THE UNIT HAS SHUT DOWN. TO RESTART - YOU MOVE THE THERMOSTAT TO OFF WAIT 5 MINUTES OR SO AND PUT IT BACK ON COOL -- IT WILL RESTART ALMOST EVERY TIME AND RUN FOR SEVERAL HOURS. IN THE PAST IN THE PAST I REPLACED THE DEFROST CONTROL BOARD BUT WHEN I DID THAT THIS TIME IT STILL SHUTS DOWN - WHAT OTHER PROBLEMS ARE YOU AWARE OF ON TH


You may have a low pressure or high pressure switch tripping out the board as well. You might try cleaning both the indoor (evaporator) coil and the outdoor (condensing) coil. Be sure to turn off the power source before servicing this. ... Coleman Air Conditioners

My RV AC unit was runs good on high cool last night but this morning it was only running on low fan(some what cooling it Seems)What should I check first. thermostat,fan ???


Low medium high speed of fan iscontroled by selector switch on the thermostat or recheck the thermostat if ok check control wirnig from thermostat to the fan relay on control borad and from relay to the motor. ... Dometic Rooftop RV Air Conditioner

LG AS-W2463 SERIES(LSZ 24) SPLIT INITIALLY THE SYSTEM SHUT DOWN DURING COOLING WITH AN ERROR MESSAGE 'C06'. iNVESTIGATED AND FOUND THE CONDENSOR FAN NOT RUNNING. CHECKED VOLTAGE TO FAN MOTOR - OK. REPLACED MOTOR, STILL NOT RUNNING. WITH PORTABLE EXTERNAL FAN BLOWING THROUGH CONDENSOR, COOLING NORMAL.


Check the simple things first, did you changed the run compasitor to the fan motor that should power up the fan ... Air Conditioners

I have recently purchased a Dimplex GDC18RBA portable airconditioner and it blows out cool air, however it doesnt cool down the room and the thermostat temp doesnt go down to the temperature I set it at. I had it on all night long last night and the lowest temperature it got to was 29 degrees. Please help


The air is cool but doesn't seem cold enough and does cool the room to specified temperature ,then check the following:--\015\012 \015\012If the air doesn't seem cool enough it is ... Air Conditioners

Have a 5ton straight cool ac system. It's a Payne puron split sytem. metering device,txv. It will run for about 5 miutes during that time u can feel some cool back on the suction line. after that run time it will start to make a hissing noise. Over amp and shut off on internal overload. Any suggestions? Complete system is brand new and was put in around November.


Brand new systems won't require cleaning. Debris could get trapped inside the internal parts/lineset and break loose and cause a blockage which could cause high head pressure, hissing and over amp. It is possible that the charge requires readjustment ... Air Conditioners

Hi guys, I try to solve this problem i have with my AC unit American Standard YCC048F. Short: The heating and cooling are ok, the only problem is the fan doesn't turn off even if heat or cool turns off. Some times even if i put the thermostat is on off the fan starts running. I try to find a relay for the fan but i don't know what can be the problem. Please help, for now i am switching on/off the unit to have it run. Thank you. Costi


If the unit has printed circuit board the relay maybe in it which has probably welded contacts, must change the pcb then or try tapping it, it might help or even, try off and on power at circuit breaker it migt reset the pcb. ... Air Conditioners

Carrier thermostat Hello, My Carrier electronic thermostat is connected to a heat pump.  It was set to the COOL position during a summer thunderstorm when the AC suddenly began running no matter what the SET temperature was.  It works normally when I change it to the AUTO position.  The HEAT and EHEAT positions work normally. I tried cutting power to the unit for 2 days, after which it worked normally even on COOL, but after a short power failure it resumed the problem of running the AC continuo


I hate to say it but Ive had trouble with Carrier's Tstats doing similar improper things. Unfortunatly the only repair is going to be replacement of the whole tstat. I recommend Honeywell's FocusPRO or VisionPRO tstat. Ive yet to have one fail and th ... Air Conditioners

Ecm motor runs fine in cooling mode and when stat calls for no cooling motor still runs slow and smells as if burning


Replace motor! ... Carrier 38CKC036 Air Conditioner

HAVE A HOLIDAY RAM PUSHER HAS THREE DOMETIC 15000 A/C UNITS PROBLEM IS SOMEONE HAS GUTTED OUT AND REMODELED ENTIRE INTERIOR INCLUDING CELING . IVE BEEN ASKED TO FIND PROBLEM WITH CENTER A/C (ZONE 2) FRONT A/C HAS BEEN INSTALLED FROM FACTORY ON ITS OWN THERMO (SAYS CUSTOMER)NOW REAR A/C IS ZONE 1 AND CENTER IS ZONE 2. HIS COMPLAINT IS CENTER A/C DOESENT COOL, SO I CHECK IT OUT AND FIND FAN RUNNING COMPRESSOR RUNNING AIR MOVING A LITTLE WEAK BUT DEFINANTLY NOT COOLING. HERES THE STRANGE PART, ON


Yes, the extra ducts can certainly decrease the force of the airflow dramatically. It sounds like someone was trying to use the center AC to cool all three zones. \015\012\015\012Yes a compressor can run and not cool. You are correct in t ... Dometic Rooftop RV Air Conditioner

Amana PTAC Unit is not producing heat. Fan works fine. can not locate manual reset for heat although a label on the unit says there is one. I have an Amana pth153b35ae ptac unit that the heat will not come on. The compressor will run in the cooling mode but not in heat mode. I verified the switching valve is working and the capacitor seems to be fine as the compressor will run in cooling mode. The thermostats seem to be functional because relays can be heard clearly when changing temperature se


I know this is late but I had to add a solution to this problem since I had the exact same problem and was able to solve it. The probelm is not your control board. On these units, the heat pump compressor will not kick in unless the temperature you ... Amana PTH123B25AJ Heat Pump Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific