Having problems with your Air Conditioners ?

Cooling well it starts just fine cools for about two minutes then the compressor shuts off unexpectedly? i thought it might be the thermostat? i bypassed the thermostat completely but no luck? i can here the compressor come on when the unit is switched on and it does appear to cool down before the compressor shuts off and the fan keeps running.


Answers :

Check if the condensar ( outside fan unit) is getting enough free ventilation. IF there is no free air flow you will mostlikely be triping the unit due to short cycling. Ie the unit is pulling its own discherge air causing the compressor to trip due to high back pressure

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a camper with a Dometic rooftop air conditioner. The Model No. appears to be 3310700.012. The thermostat it the type that fully shuts off the unit (compressor and fan) when the set temperature is reached. The problem I am having is that the "dead band" (time between unit shutting off and coming back on) is too long, allowing the camper to become uncomfortably warm. A. Can the band width be adjusted to cause the unit to cycle sooner. Or, better still... B. Can the thermostat switch be bypa


No both the options A and B which you gave cannot be done.yes option B is possible in some form.but in this case fan will not shut down and this will burn the fan motor and even make the fan wirings short/.so option B is also not advisable.but the pr ... Dometic Rooftop RV Air Conditioner

Cooling well it starts just fine cools for about two minutes then the compressor shuts off unexpectedly? i thought it might be the thermostat? i bypassed the thermostat completely but no luck? i can here the compressor come on when the unit is switched on and it does appear to cool down before the compressor shuts off and the fan keeps running.


Check if the condensar ( outside fan unit) is getting enough free ventilation. IF there is no free air flow you will mostlikely be triping the unit due to short cycling. Ie the unit is pulling its own discherge air causing the compressor to trip due ... Haier HPAC9M Air Conditioner

I turn on the Central A/C unit with the thermostat. The attic fan unit goes on and the system cools the house. When the system shuts down the fan unit shuts off but the outside compressor keeps running. The only way the outside compressor goes now off is when I flip the 240 switch on the main box. This just started. Is it a thermostat problem? Thanks.


Could be a thermostat problem but even more likely the contactor on the unit outside is stuck. In order to change this part you will have to get in to the outdoor unit. The contactor is the automatic switch that the thermostat energizes when the t ... Air Conditioners

This is about a 15 YEAR OLD Trane XE1000 30,000 BTU A/C unit. The A/C was not working, but right after I called to have someone come fix it, it started working again all by itself. When the unit was not working (for about 18 hours). The house got up to about 80 degrees with the thermostat set on 70. When the HVAC tech got here (next day), he told me the compressor is shot because the thermal limit switch inside the compressor is overheating. The area where the thermal switch is getting warm, but


You can wait just buy a capaciter start system theat will override the old start capaciter, this is a common problem for all ac systems. just bu the ac start replacement and yo should be good to go for a couple more years. and if you want a reference ... Air Conditioners

COMPRESSOR I HAVE A 13,500 DOMETIC ROOF TOP UNIT ON MY RV. THE COMPRESSOR COMES ON EVEN IF THE THERMOSTAT IS IN THE OFF POSITION. IT WILL COME ON AND RUN FOR APPROX 5 MINS. THAN SHUT OFF. IF YOU PUT THE THERMOSTAT ON COOL AND LOWER IT BELOW ROOM TEMP. IT WORKS FINE.


Thermostat is badReplace it ... Dometic Rooftop RV Air Conditioner

Amana PTAC Unit is not producing heat. Fan works fine. can not locate manual reset for heat although a label on the unit says there is one. I have an Amana pth153b35ae ptac unit that the heat will not come on. The compressor will run in the cooling mode but not in heat mode. I verified the switching valve is working and the capacitor seems to be fine as the compressor will run in cooling mode. The thermostats seem to be functional because relays can be heard clearly when changing temperature se


I know this is late but I had to add a solution to this problem since I had the exact same problem and was able to solve it. The probelm is not your control board. On these units, the heat pump compressor will not kick in unless the temperature you ... Amana PTH123B25AJ Heat Pump Air Conditioner

I have a Duo-Therm Penguin model#610115405 that cools and the fan changes speed(slower) when the room gets cooled and the compressor kicks out, but the fan will not shut down.I have the same unit fwd in my RV that works fine. I tried switching the thermostat,ptcr relay and the capacitor that is below the ptcr. Any other suggestions ? Dont see anything that else that I can easily switch to check.Still not shutting down?


Hi,\015\012the relay that is suppling the power to the fan is welded shut and is not opening. This often happens with relays, the contacts get pitted and then they heat up and weld fast. The relays that run the fan faster and slower are still w ... Dometic Rooftop RV Air Conditioner

Hi there, My compressor unit outside runs constantly. The fan inside will not come on unless the on/off switch on the thermostat is switched on and off several times. I have replaced the thermostat and the problem remains.


The compressor will keep operating tell reaches the temperature that been set for, also the comp. needs cut off to stop working, so you have the cut off & thermostat that controls the comp. you replaced the thermostat that leave you with the c ... Whirlpool ACQ122XK Air Conditioner

Heat would not come on and fan would not cut off even when thermostat was set to off. Took off the outside panel of the unit and red light was blinking 7 times - rollout switch fault. Since fan would not shut off, took out the disconnect to shut off system. What does this mean?


This means that the rollout switch was tripped by a flame coming from burners. could be a plugged fue or bad inducer motor, or a bad rollout switch. the fan will not shut off as a safety feature it keeps running incase the heat exchanger is to hot to ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

I have a Duo Therm Quick Cool, model 59516331, mounted on a 2001 Dutchman. With the A/C on it cools great but the compressor does not kick out or cycle. The unit runs until it freezes and can't blow air. When I shut the unit off manually from the thermostat the compressor continues to run, the only way to shut it off is to shut the breaker off. I am wondering if it could be the thermostat? I have checked everything I can think of. Any advice for me?


... Air Conditioners

We installed a Honeywell RTH230B thermostat on a Trane XE60 Air Handeler this winter. When we put the system on heat it works fine. However, when we put the system on auto for cool the compressor fan comes on but not the air handeler fan. On the air handeler the terminal strip from left to right is R W Y G B/C. The red wire on the R terminal comes from the contactor on the compressor unit. The other wire from the compressor unit is connected to a gray wire that goes to the thermostat. The W


I ran into this before and had to call Honeywell for help in the wiring...it seems the wiring was not done to standard, and they were able to help me get it straight in about 10 minutes and at no charge. ... Air Conditioners

I was running the genarator with the a/c on and the genarator stopped with the a/c on.No power to the a/c. I plug in the motor home to 120 current and tried the front a/c and the compressor comes on without the fan when the thermostat is in off position. the only way I can shut it off is change the switch to rear air position. I check the fuses and circuit breakers and all are ok It seems to me maybe a relay is sticking. what can I do John


You are right! When thermostat off, no out door fan or compressor should run in out door unit. Replace Compressor contactor relay immediately Thanks. Helpful?. ... Dometic Rooftop RV Air Conditioner

I have a heat pump system with gas as auxillary heat. What outside temperature should I switch my thermostat to "Emerg Heat" to run only gas? I also have a dial that appears to be some sort of temperature control on the lines that run outside the house to the compressor unit (currently set at approx 32). Is this for defrost control or does it tell the heat pump to shut down when the outside air gets below where this dial is set and then use only gas heat?


The dial thing you are talking about is a low ambient control that will not let the heat pump run below the set temperature should be set between 32 and 40 degrees farenheit. The heat pump is not effiecent below 32 degrees as I would reccomend only r ... Air Conditioners

I have a Coleman rooftop rv ac unit. THe air it blows is not as cold as it used to be. the compressor shuts off frequently even if the thermostat is set all the way to coldest. The compressor will start again after several minutes and runs_air is not very cold_then it shuts off again and the cycle repeats. Is there anything that can be serviced for this. Can it be recharged with freon? Could it be the thermostat? Why is the compressor shutting off?


Try to check the condenser coil fins, there should be no clogged areas on fins so that it could properly discharge hot air which is needed to complete the refrigerant cycle. If the condenser heat is not discharged properly, hi refrigerant pressure wi ... Coleman Air Conditioners

My unit's compressor will intermittantly stop working. The thermostat seems to keep the intake unit working but since it can't get the temperature down it never shuts off. We have been removing the batteries and letting the thermostat reset for 20 minutes. (thermostat Honeywell RTH23110B). After the reset the compressor will work again but will fault within a day. I am pretty sure that the compressor and fan are functional as if I press the contactor down it begans functioning. I also, to he


If the air handler coil is clogh , the air won't go through and the compresor will shut off on overload because of high head pressure, also this will happend if the condenser coil (outside) is blocked or if the fan dosn't work .Also if the outdoor un ... Air Conditioners

Compressor problem? My outdoor unit comes on with the fan blowing just fine. Then I hear a buzzing sound for about 2-3 seconds which I believe is the compressor trying to come on. (Incidentally, a couple of lights inside the house seem to dim at the same time that the buzzing sound occurs.) The buzzing sound reoccurs every couple minutes while the outdoor unit fan and the indoor blower both continue to run. I have shut down both the outdoor and indoor units for a couple hours and tried restarti


The buzzing is your compressor trying to start. It is going off on internal overload caused by heating up of the motor windings.If you have an amp meter you could check the amp draw of the comp against the locked rotor amps listed on the tag You cou ... Ruud UBHC Air Conditioner

I had to change the compressor of my 2 ton bio-sleep split AC from samsung (6 months old- but stopped working at 5 months). Now when the ac is powered on the compressor starts instantly, without the 3 minute delay. When the indoor unit is switched off with the remote or switch, the compressor continues to run. The only way to shut it off is to shut off the circuit breaker. Help please.


I would say control board. Get on Samsung web site and go to technical support and get there 800 number. I have called several times and they can walk you thru it. Just have your m They model number handy. They can also tell you wether you need a ser ... Samsung AW0503B Air Conditioner

Model(MC42B-1A) The unit stoped working. Now it will not come on. There is 240v at the outside unit. When the contactor is pushed in manualy it starts and runs untill released. Filters are new, thermostat is set below room temp. Settings are on cool, fan(auto). Tried to switch fan to manual and it did not come on. Swithced it over to heat and it still did not come on. All breakers are good. I am at a loss. Why will my unit not come on and run.


Hello. It appears that your thermostat is bad. Change it and you should be up and running again. J. ... Air Conditioners

HAVE A COLEMAN MODEL DRHSO601CB --- THE UNIT WILL RUN FINE FOR SEVERAL HOURS WITH GOOD COOLING AND THEN PERIODICALLY THE TROUBLE LIGHT WILL COME ON THE THERMOSTAT AND THE UNIT HAS SHUT DOWN. TO RESTART - YOU MOVE THE THERMOSTAT TO OFF WAIT 5 MINUTES OR SO AND PUT IT BACK ON COOL -- IT WILL RESTART ALMOST EVERY TIME AND RUN FOR SEVERAL HOURS. IN THE PAST IN THE PAST I REPLACED THE DEFROST CONTROL BOARD BUT WHEN I DID THAT THIS TIME IT STILL SHUTS DOWN - WHAT OTHER PROBLEMS ARE YOU AWARE OF ON TH


You may have a low pressure or high pressure switch tripping out the board as well. You might try cleaning both the indoor (evaporator) coil and the outdoor (condensing) coil. Be sure to turn off the power source before servicing this. ... Coleman Air Conditioners

The outside compressor and fan will not shut off. I have turned the thermostat system to Off and even to heat, but it will not stop. I went on a trip, increased the room temp to 80 on the thermostat and left. When we returned 2 1/2 days later, the coils were frozen and no air was comiing through the vents, even with the blower motor working. So I turned the unit to furnace and melted the ice on the coils, but had to pull the fuses on the outside box to get the compressor to shut off. Is there a


Sounds like the contactor is stuck. That's why nothing will stop the fan and compressor except killing the power to it. You should be able to get one fairly cheap. ... Ruud UAKA037 Air Conditioner

I have a Coleman Central Air/Heat System. This year, the outside compressor (or whatever it is called) is shutting off within minutes of the air conditioner coming on. This is resulting in the home never cooling down. I can reset the system by shutting the air off inside the home for a few minutes and the outside compressor comes back on, but again, only for a minute or two, and the unit only blows what seems to be room temperature air.


Do you know the devices model. It would help in locateing the manual. also I beleave you have the manual?\015\012\015\012As micromaster already said, check for sleep timer.\015\012\015\012has the system worked fine before has ... Air Conditioners

Frigidare window air conditioner with remote control about 3 yrs old. All controls seem to be working except when the energy saver mode is suppose to shut down the unit / the display goes dark but the units compressor seems to be still running after shutdown?? Unit will not shut completely off unless we unplug entire unit. Unit also has a built in safety breaker switch on plug which works fine. Any suggestions?????


Hi,There might be many reasons. One of them would be Thermostat. If there is an issue with thermostat, ac would show the above symptoms.Check and let me know.Hope i helped you.Thanks for using ' Fixya ' ... Air Conditioners

Mit.hp model MUH24WN Unit was working fine shut off at night went to turn on during day and would not come on it was tripping the circuit (replaced circuit) still tripping we know it is definately compressor unit but I don't believe it is grounded tech. telling me we need a new unit other sources that work on these units say something may have gotten into the compressor, If you could tell me the possible answer to this problem?


... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

I have a Lennox model CB19-51-1P air handling unit with HP19-511-1P compressor heat pump unit. I just turned the heat on for the first time this season. And I am getting low heat volume. The heat pump unit is running for long periods. I am getting enough heat to maintain the 70 degrees setting with constant cycles, shutting off for short periods, running long periods. When the thermostat is turned to a cooler temperature, the unit shuts off as it should. Could you please help trouble shoot po


First thing you need to check is if the reversing valve is working you maybe running your A/C with the heat strips on depends on the t-stat your using some heat pumps will bring the strips on with a high d ... Air Conditioners

Reversing valve not switching over to air on heat pump. compressor will come on for about 10 minutes, then shut off. Hot air comes out vent.


Look for any refrigerant leaks - no or low refrigerant can cause problems in both modes. The unit may be going off on low suction.\015\012\015\012-OR-\015\012\015\012The unit may be stuck in the heating mode. \015\012 ... Ruud Matching Split Air Conditioner