Having problems with your Air Conditioners ?

Central air frost buildup on my coolent coil and air is not turning on neither is the blower.Can some one help me with this?


Answers :

First turn your thermostat to the fan on selection, if this allows the blower to run then replace the stat. If blower will not run in on selection it is either a bad control board or blower motor. I can walk you through getting the blower on if the board is bad so it will operate until you replace it.\015\012\015\012Thx\015\012RepairUSA

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Central air frost buildup on my coolent coil and air is not turning on neither is the blower.Can some one help me with this?


First turn your thermostat to the fan on selection, if this allows the blower to run then replace the stat. If blower will not run in on selection it is either a bad control board or blower motor. I can walk you through getting the blower on if the b ... Carrier 38CKC042 Air Conditioner

I have two Friedrich PDE15KSB-C units. When trying to turn on the heat neither will kick into the heat mode. They both blow cold air only. When they are first turned on the air blows, and there is a click sound as though the unit is trying to start the heat pump, but then nothing really happens...just the fan continues to blow cold air. Any help would be appreciated. BTW the dip sticks are all in the positions of 1234 ON, 5678 OFF - factory setting. I did try to turn 7 on for the emergency


Keep +10 degree from your room temp and also thermostat in "heat" . And then check. But in your case, I think RV not energized. If no proper voltage in RV in heat mode, check the wiring to RV. If voltage in means RV not working properly. You have to ... Friedrich PDE15K3SB Portable Air Conditioner

Hi there, iwant some help in duct type air condition (trane)60000 BTU .when i was gave the out door freon i recognized that the high pressure fans were off and the compressore was on ,so i turn off the air condition for seconds then turn on i found that the high pressure fans run for one minute and then turn off and the compressore still running ,so what i shell do????


I hate to say this but it sounds to me like you need a professional. You may hear some other advice but it's not safe for anyone to work on the outside compressor unless they really know what they're messing with. The fire and death by electrocutio ... DeLonghi Trane 5t Rooftop Air Conditioner Ycy060g1m0ad

I have an Ager split system in my bedroom and lounge, the one in the lounge works find but the one in the bedroom shows F2 and when I turn it on it is just blowing out room temperature not cold air, then one is the lounge is fine, can anyone help me with this problem please....Maree


... Haier Energy Star ESA3183 Air Conditioner

Hi, I have Samsung AQ18U Air conditioner split unit, i have it installed only 10 days ago, and the warranty as bad as possible, the problem description as follows: 1- i turn it on it works for approxmitly 30 to 40 minutes 2- then suddenly it closes the fan exit and a green light flashes from the smart saver indicator. 3- i turn it off , then turn it on and the cycle repeats again. Please any one help me


Change the thermister ... Samsung AS18A6RB Air Conditioner

My air conditioner was barely blowing air out of the vents when i looked down stairs the filter was dirty but only a month old. i also noticed condensation on the pipe with black foam/rubber insulation on it. also a sopt where the rubber was ripped had frost i turned my a/c off but have no ideal what the problem is please help


Hi,\012You have a leak in your A/C unit and the system is low on freon...\012Get a pro to look at it fix the leak and recharge it...\012\012Here is a tip about troubleshooting your air conditioner...There are many ... Air Conditioners

Can't turn my Mitsubishi Air conditioner on - just moved in with one installed and it won't turn on via remote or override - run light is on, timer light keeps flashing x 3 Model number skm25ya1 - live in Townville Nth Qld is hot - help please


... Mitsubishi Air Conditioners

The fan for my air conditioner will not turn. When we cut the system on it makes a humming sound and the light go dim for just a moment and this goes on repeatedly. No heat or air. We have a dual system. One outside and the other is in the attic. Can you help. I am on a fixed income at this time and no money for a repair man.


If the humming noise is coming from the attic it would indicate that the blower motor on the air handler is trying to start but the rotor is locked.If the humming noise is coming from the outside unit and the fan runs but the compressor d ... Air Conditioners

Hello sir, i am using a electrolux-eaw18crp window ac..te problem is ..whenever i turn on my ac...all lights are on,but no air blows,neither fan works nor the compressor..i dont know wats wrong..can u please help me or give a easy solution...because i am scared of opening the ac...


Sounds as if there is an electrical short at the on off switch. Would recommend having a qualified tech look at unit. Good Luck\015\012Dave ... Air Conditioners

I have a window air conditioner in my living room. It runs constantly because my asthma acts up when it's too hot or muggy outside. When I went to bed last night, I had the AC on low. When I got up this morning, it was deader than a door nail! Nothing ... nada ... zip! I tried turning it on and off a couple of times, but still nothing. I'm on social security so I can't really afford to buy a new one or even have a tech come to look at it. Can you help me?


Might just be a broken wire. OR it could be a failed cap. If all of th ... Kenmore 6000 BTU Single Room Air Conditioner

Air Handler: I have two 24V supply lines one from the transformer the other, I think from the condenser fan. Both wires are connected to a relay which operates the indoor blower. When the 240V power supply is turned on I get a buzzing sound from the relay. Can anyone help me with this problem. Mickey


You have 24 volts from the indoor thermo to the transformer in the air handler then 24volts from air handler to the contactor when this is energized it goes to 240 volts to run the compressor and outdoor fan. Sounds like the contactor is not enegizi ... Air Conditioners

Ok so I have know replaced the control board air handler board today the unit also has a new transformer and a new blower motor and the heating elements test good not burned at all and it still continues to burn the 5amp fuse out worked for about 30mins now blows fuse out as soon as new one is inserted and breaker turned on....I'm lost and have no other ideas with all new parts this should not be happening, Can anyone Help!!!!!


... Carrier Bryant Control Board Air Handler HK61EA006

I purchased a commercial cool room air conditioner by Haier (7000 BTU) and I set it up and turned it on and used the remote and everything worked accordingly. I came back in the room to adjust the settings and the remote would not work. I changed the batteries (though they were just out of the package 3 hours ago) and was able to adjust one setting and the remote would no longer work. Unfortunately with this model, all settings except the on/off switch are on the remote. Please help!


I am assuming that this is the same thread that I just answered only with a different title. ... Air Conditioners

I have a split unit and the one wall unit does not work at all. I called an air conditioner contractor and he replaced the circut board and blower motor. When he turned the unit on it blew the new parts. Now he is telling me that it cannot be repaired. Can you please help ?


Hi,I have no idea, how they replaced the circuit board and blower motor without running the diagnostics or inspecting different components. It would be really hard without looking at the AC that what's wrong with it. It could be a problem ... Samsung AS18A6RB Air Conditioner

I have a 2011 Wildwood travel trailer. I tried to use the air conditioner for the first time this weekend. When I turned the themostat to cool and 65 degrees the air unit "clicked" one time but the unit did not start. I tried various settings but nothing. When I turned the thermostat off the unit clicked one time again. This is a brand new trailer and the first time I tried the air. Any thoughts?


First thing to check is that the breaker for hydro to AC unit is in the on position. The clicking sounds like 12 VDC is OK but hydro may not be on to it. ... Dometic Rooftop RV Air Conditioner

We have a new house and it came with central air. I have turned on the air and turned on the circuits and noticed that the outside fan on the outdoor unit was spinning round (good) now, I checked and the fan is not turning. Turned the unit on and off, still no turning and checkecd the circuit breakers...Any help please. Model is Aire_Flo Outdoor unit AFAIR12B30-A P I hear a low hum to the unit outside. I see trouble here.


First check to be sure the circuit breaker for the outside unit is not tripped. Turn the two pole breaker all the way off all the way off and then back on. If the outside unit still does not run you may have fuses in a disconnect box by the outside ... Air Conditioners

Our Carrier central air is unresponsive, nothing at all, no noises, air handler and condenser unit will not turn on, please help me before I lose more weight in my 150 degree attic. The serial # for the air handler is 0695803341 and the product # on AH is FB4ANF030000ACAA / we only have central air, system is not connected to any heat source Early sunday morning I turned the T stat to the off position, when i came home a few hours later I turned it back to the on position and nothing at all, no


I think you need to slow down and start fresh. \0121) You have 115v at Transformer-You are reading from Red to White\012 on windings?\012\0122) If that checked out OK are you reading 24v out of Transformer?\0123) If ... Air Conditioners

Our air conditioner came on by itself this morning. we have been unable to turn it off all day and we are still unable to turn it off. we did however have a wee bit of luck this evening, when we pushed the off button the air conditioner turned off then about 5 seconds later it turned itself back on again. please help as its not even running cool air and it has been 40 deg today and is still very humid tonight and my 2 year old son is having major difficulty sleeping!!


Hi,\012\012Please check the auto programmed ON/OFF on your remote commander. May be the auto programming is running that run your air conditioner all time without stop. Check also your temperature setting.\012To hard reset your remote , remove ... Air Conditioners

I recently purchased a used ac for my rv. it has two and one had gone out. the air coming out of the new one only gets down to 60 degrees while the air out of my old one is 50 degrees. they are both the same brand. does this mean the new one has something wrong with it or is it normal for some ac's to blow colder air i dont know is is should take it back or if it is working like it is suppose to help


No it means you 50 degree one is working better than perfect. Clean the one that is only getting down to 60 degrees but remember if a unit is dropping the air temp by 20 degrees its working fine. You ck this by cking the air at the intake where the f ... Dometic Rooftop RV Air Conditioner

My new house has an Amana Distinctions unit outside, actually 2 of them, one for upstairs, one for downstairs. It has worked the last 2 years but today we turned the upstairs on and no cold air came out. We turned the unit off and hit the reset button but still no cold air.


Check the breaker or the outside disconnect ... Air Conditioners

Our Furnace doesnt seem to be working correct. We an: Air Pro BGM075128 and is Natural Gas. It will turn on when we turn up the thermostat.. but we never get any heat through the vents. There is a switch on the side that is "on" and one that is "fan". If we turn on the "fan" only cold air gets blown through. It looks like this is for cool air. So, if we leave the fan off and the "on" swith on, we get the furnace firing up, but no heat ever comes through the vents. I tested out the thermo


Sounds like the blower motor is not working, if the furnace is actually lighting up and the burns are ignited. You should set your thermostat to auto, as if it is on fan then the fan runs all the time until you take it off of fan. I am a little confu ... Air Conditioners

I have two indoor condensores, one with both lights on, but not blowing cold air, and the other with only one light flashing, but blowing cold air. History; 5yr system, did blow 100amp breaker during storms, just usually reset and no problems, initial problem one light flashing and no cold air, and other unit with both lights on and blew cold. Any help, thanks Darrick


You need a new pc board. You can buy one from http://paylessminisplit.com ... Mitsubishi MSH09TW Air Conditioner

I have two compressors-one for the upstairs and one for the down stairs. Both compressors are working but the air flow for the upstairs basically does not come out. You can hear the unit running but no air upstairs. Down stairs the air is working. Is there any way to turn the airflow up or adjust it to send more air upstairs. I had the capacitor replaced in the down stairs compressor a few weeks ago and for the upstairs about 1 1/2 years ago. when the air downstairs started working a few d


Hello,Thanks for using FixYa.I suggest that you try to have the fan that routes air upstairs checked. Its possible that the motor is already going bad.I hope this helps. Thanks and good day.HotRatchet ... Air Conditioners

Our air conditioning was working during the day. when one family member turned the air up from 72 to 75 she saw the screen process what she wanted and walked away. when another family member went to turn it down, the screen was off. i have a honeywell visionPRO thermastat but no air conditioning at the moment. is my air conditioning not working because the honeywell theromastat needs to be trouble shot or is it not working because the machine that produces the air conditioning itself not wor


Open the thermostat and look for batteries, 3 AAhttp://www.heater-home.com/photos/2129-5b.jpghttp://www.heater-home.com/manuals/th8321u1006manual.pdf ... Honeywell Air Conditioners

One of my AC units froze up. I cut the unit off. after it defrosted I turned it back on soon after we smelled wires burning. I turned the unit off. Now when I turn the unit on the outside comp. goes on but the air handler will not turn on , I checked the low volt fuse it is fine and ther is no reset switch, what could have happened there are no burnt wires inside the air handler.


You may have a couple of problems now. The original issue of icing up is most commonly due to low refrigerant in the a/c. For this you will need a professional to correct.The second problem sounds like it may be a bad capacitor for the in ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific