On/off cooling when I turn air conditioning on it blows cold air for a little while then turns warm.I noticed the outside fan wasn't running all the time. when it's running the air is cold, when it's not air turns warm.


Answers :

You will need to replace the outdoor fan and capacitor before it cause damage to the compressor.\015\012\015\012Thx\015\012RepairUSA

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

On/off cooling when I turn air conditioning on it blows cold air for a little while then turns warm.I noticed the outside fan wasn't running all the time. when it's running the air is cold, when it's not air turns warm.


You will need to replace the outdoor fan and capacitor before it cause damage to the compressor.\015\012\015\012Thx\015\012RepairUSA ... Intertherm P3RA-048K Air Conditioner

UNIT RUNS AN EXCESSIVE AMOUNT OF TIME AND AIR IS COOL NOT COLD COMING OUT OF VENTS CARRIER 58DLA / 58DLX CENTRAL AC FAN AND COMPRESSOR ARE OPERATING BLOWER IS WORKING UNIT IS TURNED ON TO AC TEMP SET AT 76 UNIT RUNNING FOR OVER AN HOUR OUTSIDE TEMP 80 THERMOSTAT REGISTERING 77


DOES THE HOUSE FEEL DRIER IF IT IS 80 OUTSIDE WITH ALOT OF HUMIDITY THE UNIT WILL RUN FOR A LONG TIME TO REMOVE THE MOISTURE(HUMIDITY) OUT OF THE HOUSE BEFORE TEMP DROPS DRAMATICALLY IS THERE WATER COMING OUT OF THE DRAIN PIPE OUTSIDE ... Carrier Air Conditioners

I have a Danby DPAC10030 air conditioner. It was working fine until yesterday, when we moved it to another room. Now it blows cold air for 5 minutes and then the air turns hot. The a/c motor continues to run even though the air is no longer blowing cold air. The current ambient temperature is 25 degrees C and I have the a/c set to cool to 17 degrees C. The timer has been turned off (0:00 on and 0:00 off). I noticed that the hoses (exhaust) feel quite hot. Not sure if that it normal within


Clean you filter and clean the area under the intake duck it will solve your problem ... Air Conditioners

Ac problems i have a goodman ac system. i can not get it to cool one side of the house. i have it turned down to 72 and the thermostat says it is 80 in the room. i can hear the return vent sucking air and the ac unit outside is running but no cold air is coming inside. the unit outside has cold air coming out the top when the fan inside it is turning


Hello from KOOLBREEZES, this is a simle problem and easy to fix. You have 2-lines going to / from your outside unit. a SMALL COPPER -line and a LARGE COPPER line with insulations. The fat line is suppose to have moisture on it wheres it,s not insulat ... Air Conditioners

I have a maytag nmpeb08f2a portable ac, just started it up for the season. cleaned the filters and coils by wiping down . I also emptied bottom resevior. Im not getting cold air when on cool setting, tried lowering temp all the way. when i turn it on it will be cold for a short time, doesnt fell cold like befor, the temp will go down maybe 1 degree then, no more cool air. can i add refrigerant to this unit?


Frank, refrigerant is what it needs, but it should be done by a pro. Unless you have experience with this sort of thing, it's not a DIY project, ... Maytag Portable Air Conditioner M6P09S2A

Central air unit out side will run non stop in hi temp cond and not cool very well, coils have been cleaned along with condenser and evap. it will run and turn off in early morning hours, freion is wher it sould be put in buy hvac tec. termostat is set @ 72 deg. apt will not cool under 77 deg during hot condtions. not sure what air out put sould be @ vents, or return cold air intake sould be.


Here is what you need to do to make sure your system is charged correctly go to the furnace take the temperature of to supply temp and take the return temperature at the furnace. You should have 18-20 degrees temperature difference if your return tem ... Goodman Air Conditioners

I'm having a problem with my heating and air system, my heat only works on emergency heat ( and run 24/7) if i turn it to regular heat it only blows cold air. i dont think my outside unit fan is turning( i could be wrong about this one) how can i fix this problem so i dont have to run my emergency heat all the time


If your Heatpump's fan isn't running but your compressor is, your fan motor is out. If nothings happening at all ensure your getting power to heatpump (ex: breaker tripped, fuses blown on outside power switch, or fuses blown in breaker box?) ... Air Conditioners

Warm Air My Fleetwood motorhome Dash air is giving me problems. After I turn on the controls Blower, outlet position, AC on button and re circulate button I may or may not get cold air. After continually operating the controls mainly blower & AC button, I can some times get the AC to cool down. When it is warm it's about 80 degrees, when I do get it to start cooling it will go down to about 60, Checked with an IR thermometer at the vent. Once it does cool down it may work the remainder of the d


... Air Conditioners

Once you turn on aircon with fan with high speed, the air blown doesn't get cold even after a while. The fan makes some wierd high pitch sound as if like metal against each other. The fan stops once in a while and makes that same sound once it start turning again. This goes cyclic through out the time it is turned on but not cooling the air from the aircon.


Your AC needs a good overhauling as the fan seems struck on the bearings or the blades are rubbing the sides. Also the compressor fails to cool as there can be low gas, low pumping pressure or a blocked condenser.\012You need to remove clean th ... Air Conditioners

Weather King 8PJ10NDR01 When I turn the heater switch to ON position the furnace runs what sounds like an internal fan. Second, the igniter glows and when it reaches it's hottest stage the fan thrusts air through the air ducts / vents and the burners light for about 30 seconds to a minute blowing cool air. After a period of about 30 seconds to a minute the burner turns off. After the igniter and burners repeat this about 2 times the heater shuts down by it's self, even when the temp gauge has no


The gas valve is not sensing flame, and the unit shuts down on safety.\015\012\015\012Chances are the flame sensor is bad, its a common problem.\015\012\015\012If its a thermocouple you can buy one for 10 bucks, If its a newer ... Weather King 12AJA4801AH Air Conditioner

I have a Goodman Split Air Conditioner and the outside condenser fan was not working. relay tested ok breaker wasnt tripped, then discovered 1 leg of the 220 line was out. Replaced the breaker, cleaned the unit turned it on, cooled the house 2 degrees then it stopped working. Turned the stat off ,pulled the 220 block waited 10 minutes, turned it back on and it is currently running. Can the relay and/or start-run cap behave in this kind of intermitent way ?


Run cap may be badthumbs up ... Air Conditioners

My unit stopped blowing cold and started blowing hot.i turned off unit looked into furnace and saw pilot was still lit.i put out gas pilot and turned unit back on and it is blowing semi cool air (like fan)but not cool as it should.checked outside ac and it is running....munual says to turn unit off for 2 hrs and if it does not do right then it is compressor.we are currently in the 2 hr process. Any help would be helpful at this point.is there a reset switch or anything I could do to troubleshoo


100 degree temps/high humidity puts an extreme load on air conditioners - but if everything is right with the AC - 'overheating is not a big problem.\015\012\015\012The first thing I would check is whether or not the compressor is running ... Weather King 10AJA4201AH Air Conditioner

I have a york hvac system that is 5 years old. I have the thermostat set at 74 and when it turns on only the fan runs circulating the existing air in the house about 20 percent of the time. The ac works great when it is running but i'm wondering why it doesn't always come on. Just replaced the thermostat thinking that was the problem but it did not help. Sometimes after the fan runs for a half hour or so the ac will finally kick in and start blowing cold air. The lines are not frozen at a


It sounds to me like you have a delay on start timer on the compressor that possibly is starting to fail or someone may have adjusted the time band up on it. I myself would remove it and install a delay on break timer and a 5 minute setting would be ... Air Conditioners

Airconditioner is on all the time now, but frosty ice is forming on the coils. The air coming out then becomes cool, but not cold and then we have to turn it on to fan in order for the ice to defrost...as soon as that happens then the airconditioner is able to blow out cold air again.


Most airconditioners will have a cutout or something called a defrost cycle, which turns it off for a while to let the ice melt. And if you run it flat out all the time this may happen too (happened to me in Thailand once, so I just turned it on when ... Air Conditioners

I have a Kenmore window air conditioner unit. It turns on, the motor runs, but the fan does not turn on, and the front gets cold to the touch. I have taken it out a couple times and cleaned it and that has no affect. It was jolted and then ran for a day and a half, then quit. Is there anything I can do to get it back running? Thanks for your input!


99% of the time when a motor just hums on a window A/C is the motor itself thats bad. Jump to test if work fine, if not, here, for your model you can order parts replacement: ... Kenmore Air Conditioners

I have an electric furnace and heat pump that will at times blow only cold air during the heating season. I have checked the filter and don't believe that to be a problem. I usually have the temperature set to 74 degrees. When the outdoor temp. is extremely cold the axillary heat indicator will be on and still no heat. I can turn the heat pump off by switching to emergency heat and will get some heat from that but not as warm as I think it should be and even that will at times only blow cool


You are losing operation to your heat strips.\015\012\015\012In heat pumps, there is a secondary heat source. Usually electric heat strips. (Sometimes a gas furnace, this is known as a "dual fuel" system)\015\012\015\012The he ... Carrier Air Conditioners

I have a ruud achiever uaka outdoor central air system, the first time i ran it this summer it tripped the breaker. It stayed on for a good hour as it cooled the house to the desired temp. then it turned off, when it attempted to run again it tripped the circuit breaker. when i reset the breaker it started to buzz, then tripped it again, and i reset one more time and it tripped agin right away. Now just to see what the problem was i turned off the thermostat and reset the breaker again, i then w


Start components are likely bad causing comp to pull high amps tripping breaker careful resetting the breaker they can explode stand off to the sideyou need service all so have preventive maintenance done on the unit ... Ruud UAKA037 Air Conditioner

Unit is running, but is no longer cooling. Fan is blowing, but air is not chilled (or cold). Unit has been running fine until a couple days ago. It has been turned off for the last 12 hours and tried again with still no chilled air. Any suggestions?


Not sure if it is a package system or a split but this is what you do.go outside where your outdoor machine is, after it has been shut off for awhile, and you should hear 2 distinct noises.1 is the outdoor fan, you should see it spinning.the other is ... Fedders A6P09S2A Air Conditioner

SAME PROBLEMS 18k btu mini-split sys turn on blowing cold air for 3 mins, then turns warm for 3 mins then shuts down however the run lite blinks at 4 times intervals. outdoor unit fan alway runs at slow speed, even at start up. cleaning outdoor fan cleaning dont help. whats next? maybe the caps? thanks mike (us navy) at [email protected] in norfolk,va FAN MOVES FREELY, EVEN BY WIND BLOWN.


Glad to hear the issue is resolved.\015\012\015\012With regards. ... Air Conditioners

Water tank full light keeps coming on an shuts the AC off after about 10 minutes on a Amcor A12000E Nanomax Portable Air Conditioner. I drained all the water out of it I could and it does turn back on after I turn it back on and will run for about 10 minutes. Then it beeps 6 or 7 times and the water full light comes back on and shuts it off. There is no more water coming out of it and there is a buzzing when it comes back on but it will blow cold air until it shuts off again. Please help!


Dod u get any help with your problem because i am having the same problem and ofcource the company is no longer around ... Amcor A12000E Nanomax Portable Air Conditioner

Purchased a fedders a/c 18000 unit still under warranty. called the 800# they said company had filed bankruptcy and were not responsible for repairs. 350$ mistake. Fan runs too slow for unit to kick in. Fan will pick up speed some times when you turn it on, will start to blow cold air but only runs for a couple of minutes before fan stops turning.


Check the capacitor for the fan motor. You can do that with a multimeter with the capacitor test function or if the capacitor looks swollen then it is probably bad. Also, make sure the fan rotates freely by hand. Let me know if you need more help. ... Fedders 12,000/10,200 BTU Heat/Cool Room Air Conditioner - White

Im not getting enough cold air in my house to keep it cool during the day my air runs 24/7 but it remains hot the only time it cools down is at night


Hi, I will give you some things you can do as far as some service on this unit. What happens, is when the ambient temperature rises, so does the internal freon pressures in the system which in turn, causes the unit to work much harder and at a 95f de ... Intertherm P3RA-048K Air Conditioner

My ac stopped putting out cold air and I noticed the fan had stopped turningand was hot. I let it cool down and turned it back on, the fan was not turning but with a little push it started turning but very slowly, Is this the start run capacitor


It's run capacitor your unit has a dual one. One for fan and one for compressor. Make sure you get the right size when replacing it. ... Goodman CKL36AR36 Air Conditioner

Hotmail.comHi my Dimplex Dehumidifier only blows cool air sometimes it will kick over and blow really good cold air for about 5 minutes or so then whatever that part is, well it turns off and just blows room tempreture air for most of the time, I was thinking it might be something to do with a thermostate but I don't know if it even has one, (cause I was thinking I would diconnect it) Best Regards :) Michael.


... Air Conditioners

My indoor fan comes on but the compressor does not. I checked voltage, fuses and wiring and everything was ok. When I depressed the contact (single pole) the compressor would run and make cold air. When I did it a second time it held in and ran so we cooled the house down. Thinking the contact was bad I got a new one but it wouldn't come on but would run if I held it in and would shut off if I let off of it.. It has control voltage to the coil on the contact. The contact just wont kick in or sta


As u written here that the power is their in coil voltage than check for the neutral connection of the coil ,if it potential voltage across the coil is normal change the contacts coil & buy a new one with the same potential that u have in your ho ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific