Having problems with your Air Conditioners ?

FAN ISNT TURNING ?

\015 Hello,, I have a fedders window unit, \015\012Series 6X07F2B i cant find tech info any where .\015\012\015\012the compressor turns on when i power on the unit but the fan does not turn , no nothing \015\012as well no cool air , and keeps turning off\015\012\015\012is there any info online onwhat is wrong ? or how to take front off and inspect inside ?\015\012Thanks in advance\015\012Mir*\015

Answers :

You won't see much when you take the front off just the evaporator coil and air output ducting. You'll need to remove the whole back cover to get at the workings. The evaporator and condenser fan are one motor with a double shaft. the double shafted motor may have dry bearings - they are oil-lite bearings, sintered bronze set in a felt holder. there may be a small capacitor on the outside of the motor. with the back cover off, locate the wires going to the motor. if you have a meter to read voltage, proceed. If you have no meter STOP, visual inspections won't get you very far. the motor probably is a multispeed motor. If you are squeemish about taking voltage measurements don't go any further. Get someone with knowledge of electricity.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

The fan on the condensing unit isnt working it works for awhile and then shuts off,then the compressor starts to work by itself really hard and the whole condenser heats up really fast so I turn off the breaker and start it again but the fan makes and electric humm and I have to push start the blades to get it to spin and then it will work for awhile and then the fan will stop again after about an hour and then same thing happens


Does the fan turn freely or is it hard to turn by hand? If it is hard to turn the fan motor may need to be replaced. If it isn't hard to turn then check the fan capacitor. You can test it with a multimeter or take it to a heating and air supply and g ... Goodman CLT36AER36 Air Conditioner

FAN ISNT TURNING ?


You won't see much when you take the front off just the evaporator coil and air output ducting. You'll need to remove the whole back cover to get at the workings. The evaporator and condenser fan are one motor with a double shaft. the double shaft ... Fedders A6X05F2D Air Conditioner

I have water chiller i bought it in may ,when it is ready to use the blue light is supposed to turn white but this isnt happening you can hear the fan working and you can feel air comming from the vent but the blue light remains blue and the water isnt cold the model no is R/H 14116


Sounds like a bad compressor,should be under warrenty for a least a yrear ... Air Conditioners

My Carrier 43B00HP - 1 is not blowing cool air. The fan is working but the cool air isnt coming out. If you turn it on and leave it on for awhile it turns off by itself


Please check your compressor whether it takes correct amphs. Due to weak in capacitor and also less rpm of fan motor the compressor gets overheated and it turns the unit off. If capacitor weak change it. If less rpm on fan motor change fan capacitor ... Carrier Air Conditioners

Carrier unit runs all the time, never shuts down and the fan in the house will not shut off ' the house isnt getting beloe 80 degrees inside, even though I have the thermostat set at 76, I turned the thermostat on 70 about an hour ago and the temp inside still isnt falling


Ya need preventive maintenance preformed evaporator clean condenser cleaned and the blower wheel clean unit could be under charged have it tuned up and your electric bill wont surprise you leave it running like it is and you will have a very large b ... Air Conditioners

My portable LG (model LP0910WNR) AC keeps shutting off the a/c but keeps the fan on. when i turn on like normal and select cold (meaning a/c on) i hear it kick the compressor on and cold air is flowing then approx, 3 minutes later ill check on it and it blowing ambient (room temp) air only. and the a/c compressor isnt on just the fan. only 6 months old


... Air Conditioners

My inside air conditioner fan isnt turning on whats wrong?


If the in side blower motor turns off with the out side unit normal operation if the thermostat in the auto position set for cooling If the out side unit run with out the in side unit the out side unit will be wrecked . sounds like you need service a ... Air Conditioners

The Fan on my a/c unit isnt turning. Whats wrong with my a/c unit?


Check power supply, check supply circuit fuses, if all good trace wire to fan motor itself check for current, if voltage is present check ground circuit for open.. if all checks good fan motor is bad or fan blade splines are stripped cause motor shaf ... Air Conditioners

I have a Dometic rooftop Air conditioner in my RV When I turn it to low medium or high the fan run the same speed and when I turn it to AC it will run for about 5 min then the fan will shut off but the compressor keeps running I turn it off for a min or so and everythings comes back on. Turn it to the fan only side and the fan will run for 5 min then shut off a min later it comes back on then back off and on in fan only side.


Bad fan motor I suspect The windings are bad causing the motor to over heat sending the motor into thermal overload. would suggest the replacement of motor. Good Luck on repairs\015\012\015\012Dave ... Dometic Rooftop RV Air Conditioner

I have a Carrier 5 ton Air Conditioner -five years old. I turn on the thermostat and the blower comes on in the house then the compressor engages, but the fan does start. I can manuelly, start outside fan by using a long screw driver to turn the blades. Then the fan begins to turn slowly until it reach a faster speed. But I do not beleive that the fan is turning as fast as it use to. I go back into the house and after 15 to 20 minutes the temperture has not dropped. It apprears to stay a th


... Carrier 38CKC030 Air Conditioner

I have a ceiling fan with lights, last night the fan was turned on for the first time since summer, the remote is over the light switch. The remote to turn on the lights is used normally. Since turning the fan on last night there is now a humming noise even without the lights or fan on. Is this a problem with the fan or remote. pleas help the noise is low but consistent.


There is a small relay in the ceiling fan causing this noise, try turning off all power to the ceiling fan and allow it to set for a couple of minutes. Turn it back on and see if it goes away. If it does great. if not, it may not be worth the repair ... Hunter Air Conditioners

I have a Dometic 579 Series Brisk Air AC. The model Number is 57915.531. When I turn the fan on, nothing happens. If I reach up and turn the wheel blower the fan will start up and everything works. I replaced the fan motor and put on a new capacitor part # 3100248.412 was supplied. The fan still will not start on it's own. I still need to turn the wheel blower to get it started. Help!


My sheet shows part # 3100248.420 as fan run capacitor.You may have an updated number. Check voltage outputs labeled on it are same as on old one, and double check wiring is correct, to and from capacitor. Be careful not to mistake compressor start c ... Dometic Rooftop RV Air Conditioner

My 38CKCK24330 Unit stopped running, it will try and turn on every 10 or 15 mins you can here it outside buzz, I looked outside at the unit and the fan is not running. The system has power, the breaker switches are working, the furnace turns on fromt he attic. What do I need to trouble shoot, someone told me to check the switch on the unit by pressing it in to see if the fan will turn on once the button is pressed in. I did this but the fan did not turn on. Any help would be appreciated it, I


Hi angelagaddy,With the fan not running and you are hearing a buzzing noise outside this is more likely that the fan motor needs to be replaced or the capacitor ... Air Conditioners

I have the delonghi retro fan heater. when i plug it in and turn the dial, the red light on top goes on and then sometomes the fan turns maybe for 1 minute then the fan stops. the red light remains on but it won't turn anymore and just stops responding to any movemnt on the dial except when turned to 0 when the red light goes out. I haven't use either of them in about 4 months but they worked perfectly before when i used them. Please help!!


It indicates fan motor problem .servicing urgently required too. ... DeLonghi Air Conditioners

The bard geothermal (open loop) furnace will not produce heat. I will turn on the heat and the furnace will begin to turn on. The water will start to flow and then the furnace turns off. A green light on the top of the bard thermostat will then turn on. The fan unit will not turn on when the fan control is turned to ON not auto. Help.


... Friedrich WY12A33G 11300 10900 BTU HEAT PUMP AIR CONDITON IN STOCK Air Conditioner

Hi, I have a goldStar GA 1866VHR split Airconditioner, (5050w cooling and 5040w heating capacity). Today I noticed that compressor/condenser unit was still running after I turned off the aircond: from the remote control. The fan unit turned off as normal. I had to turn off the isolation switch to turn off the compressor/condenser unit. After about 2-3 hrs I turned on the isolation switch and the compressor/condenser unit came "on" stright away without the fan unit. Went inside and turned on fro


Thanks for your detailed information. But solution is very simple. The compressor contactor in out door unit. Struck. And hence, when you power on, without indoor commanding, the out door starts running. Replace same type Contactor relay ... Air Conditioners

I have a Haier HWR05XC7 that will NOT work. The compressor turns on, but the fan won't work. The fan moves freely because I tried moving it with a screwdriver, but when I turn the unit on, the compressor kicks on, but no fan. I have been fighting with this thing for weeks and am about to chuck it out of the window. Also, the red error light stays on and there is nothing in the manual on how to troubleshoot it (other than making sure it is turned on and plugged in!). No support from Haier or Circ


HEY< If you start out having problems , what do you think the future of that unit will be! ... Haier Air Conditioners

Turned on the a/c for the first time this year and no fan. The compressor turns on but no fan. The fan works when turned to heat and t-stat cranked up. This is a BDP CO. 2085C02135. Is there a relay or limit switch that only works with cool?


Depending on the thermostat you have, there may be an issue there. Some stats have a subbase that controls the fan for AC. I would like to know the model of your stat ... Air Conditioners

I have a 10-year old Carrier Gas pack Model #48GS024060301. Turned on the heat for the first time this season and the unit did not turn on. I was able to turn on the house circulation fan and since it was a warm day today I also tested the A/C side and it worked fine. The inductor motor and fan were replaced last year. All the fins on the fan blade basically flew off on the first start up attempt last year. The entire unit, heating and A/C, were serviced within the last year by a certified p


If the induction motor ain't going I would look for a blown 3 amp (purple) fuse on the control board. If that was good I would check if any of the roll out switches were tripped. If a rollout switch was tripped check or air restrictions somewhere. ... Air Conditioners

Problem I turned on my air conditioner this spring. I turned the switch to cool on and the air conditioner fan not going. I took cover off and got new capacitator didn't work. I took fan motor into electric shop and checked out fine. When I turn switch on the contact switch engages and there is a humming noise. But the fan does not work. the compressor doesn't start up. The model is at least 10 years old. How do we tell what the SER rating is?


Hi,\015\012There are two things to check....\015\012\015\012Do you have power coming into the contactor???\015\012\015\012Do you have power coming out of the contactor???\015\012\015\012If you have power goin ... Air Conditioners

I have a CH&A Goodman AC outside. My Fan and heat work properly. My A/C wont turn On or the Auto Fan. But works with heat. Can push the 24V copper connector to turn on the A/C but when i let go it disconnects. Replaced the thermostatAlso even holding the Connection the auto fan on the pump wont turn on...


You need to check to see if the voltage is coming to pull the contact in, if not then you will have to check for the voltage at the air handler/furnace on the main board for the voltage. If the voltage is at the contactor then the coil is bad and you ... Goodman CKL49AR49 Air Conditioner

Our Furnace doesnt seem to be working correct. We an: Air Pro BGM075128 and is Natural Gas. It will turn on when we turn up the thermostat.. but we never get any heat through the vents. There is a switch on the side that is "on" and one that is "fan". If we turn on the "fan" only cold air gets blown through. It looks like this is for cool air. So, if we leave the fan off and the "on" swith on, we get the furnace firing up, but no heat ever comes through the vents. I tested out the thermo


Sounds like the blower motor is not working, if the furnace is actually lighting up and the burns are ignited. You should set your thermostat to auto, as if it is on fan then the fan runs all the time until you take it off of fan. I am a little confu ... Air Conditioners

Hello, I have a Heater/Furnace problem. I have a Carrier 58RAV095-16 Natural Gas Furnace. My furnace keeps restarting it's heating process. Upon turning the heater on, a small fan will engage and run for about 60 seconds, then the fan turns off and the gas engages and the igniter clicks and you hear the gas combust and the flames spew out onto the heating rods(?) and after a minute or so, the big fan will turn on and begin circulating air throughout the house. Sounds all good so far? Well


... Air Conditioners

Turned on AC was running fine. 30 minutes later began to hear a strange noise. Opened AC/Furnance closet & heard a sound best described as air letting out of a tire. It seemed to be coming from copper pipe. Minute later sound stopped & air was suddenly hot. As if AC was turned on fan not cold. Went outside & neither fan nor motor was running. Turned fan manually. Ran for about a minute then stopped. Outside unit was making what could best be described as a buzzing sound.


Hi!!\015\012\015\012This means that the condenser fan motor (outside unit) failed, this caused to build hi pressure and either activated a safety valve to release the extra pressure or blew a line and R22 Refrigerant escaped from system. ... Goodman CKL42AR42 Air Conditioner

I have a goodman Air conditioning unit CKL49-1. The fan motor connects to the top lid. Recently the metal cracked and broke and the fan fell down inside. I purchassed a new lid mounted the fan back on to the lid. It doesnt seem that any major damage was caused. I put everything back together the way it was. When I turn it on it will only go on for a sec then a switch inside turns it off. When i looked at the electrical on the ac i noticed when i turn it on a little spark on a switch and the swit


Sounds like it is overloading and tripping the circuit breaker (that thing that pops up). More than likely when the fan fell down it stopped the blade from turning which caused the motor to overheat, melting the windings insulation which caused them ... Goodman CKL49AR49 Air Conditioner