Troubleshooting My window unit is 3 years old. It is spitting water out of the vents and sounds like it is shaving ice. Could my coils be freezing up, and what do I need to do to resolve this problem? I have turned it off for over 8 hours, but after it runs for less than one hour it starts up spitting water and making noise again.


Answers :

First I would check your air conditioner to see if it is tilted backwards it should drain to the back (outside) . also check to see if the evaporator tray is clear of debris. if it is pluged up water may back up.. let me know and if this don't help we can go deeper..Thanks

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Troubleshooting My window unit is 3 years old. It is spitting water out of the vents and sounds like it is shaving ice. Could my coils be freezing up, and what do I need to do to resolve this problem? I have turned it off for over 8 hours, but after it runs for less than one hour it starts up spitting water and making noise again.


First I would check your air conditioner to see if it is tilted backwards it should drain to the back (outside) . also check to see if the evaporator tray is clear of debris. if it is pluged up water may back up.. let me know and if this don't help w ... LG LB8000ER Air Conditioner

I have the fujitronic 1400 portable a/c. The problem is when I turn it on it will run for half an hour sometimes more some times less and then it just shuts off. Also I noticed that some times when I touch the side of the unit it will cause it to turn off or on and im not touching anywhere near the control panel. not sure if that is related to the problem. any help is greatly appreciated.


... Fujitronic FA1400 Air Conditioner

My air conditioner keeps filling up with water on the inside and spitting it out. It happens usually when it is running for a few hours and it is very nosiey. how do I fix it?


... Air Conditioners

We have a FERROLI F30 combi boiler and our DHW runs hot and cold, the boiler is working ok. But when we turn on the hot water tap to run a bath, the water gets hot for a short time before running cold again, we then have to knock off the tap and run it again {normally by running the hot water tap in the wash hand basin until its hot before transfering then to running the bath tap} sometimes it works and other times it doesn't Please can you tell us whats wrong and how to fix it?


Did you find a solution? ... Air Conditioners

Spitting water Just one night I turned my unit on and it started rattling and spitting out water. I just turned it off.


... LG Electronic Window Air Conditioner

Duo Therm dripping water in camper when shut off. My Dometic Duo Therm Ducted AC drips quite a bit of water when shut off after running for several hours on hot humid days. The condensate lines are open. The lines drip steadily while the unit runs. When shut off the lines flow a great deal of water, suggesting that the pan is full. At this point I notice water dripping from the duct work. Thank you for your help!


Remove the filter at ceiling and run the AC on cool etc, and see if you can feel cool air leaking across to return air inlet where the divider between cold and return is. Check along all edges, etc for any cool air . Careful of wiring, but you should ... Dometic Rooftop RV Air Conditioner

On a aquastar 125 vp, after the water is turned off on any of the house faucets, the burners continue, and water streams out the pipe on the side of the house.(A pressue relief, pipe I think) I can turn the water on and off a few times, and get the system to shut off. But if no one does that, hot water shoots out side for a hour or so


... Air Conditioners

Water tank full light keeps coming on an shuts the AC off after about 10 minutes on a Amcor A12000E Nanomax Portable Air Conditioner. I drained all the water out of it I could and it does turn back on after I turn it back on and will run for about 10 minutes. Then it beeps 6 or 7 times and the water full light comes back on and shuts it off. There is no more water coming out of it and there is a buzzing when it comes back on but it will blow cold air until it shuts off again. Please help!


Dod u get any help with your problem because i am having the same problem and ofcource the company is no longer around ... Amcor A12000E Nanomax Portable Air Conditioner

No water We have not used the air conditioner for a couple of years.  It is not producing any water.  It has been running for 12 hours, and as I recall, it is suppose to fill up with water after several hours.


If the air conditioner is putting out cold air, don't worry about it making water. You may not have enough moisture in the air to produce more water than it requires. \015\012\015\012In some types of air conditioners, the water taken from ... DeLonghi CF210 Portable Air Conditioner

My window air conditioner in my home is spitting out water from the vents. My husband took it apart and emptied and cleaned the water and dirt and debris out of it but after a day or so of running it, the water comes back...and starts spitting out again thru the vents onto the floor. Does any1 know what to do to fix this problem Thanks and God bless


Your window unit is probably not draining like it needs to. As it sits in the window, there should be a slight tilt to help the water move towards the drain hole. Most newer units now sling condensate onto the condenser coils to help improve effici ... Air Conditioners

I have a new furnace with a humidifier. Both work fine. The trouble is, the water running through the hose to the drain makes a LOUD dripping noise when it runs into the drain. Is there some way to stop the noise besides turning everything off..I have of tying a string to the hose and then the water will run down the string, but I am afraid the string might break and help clog the drain. any suggestions


Not seeing exactly what you have. I am guessing...does the humidifier have a trap on it coming out of the furnace?. Is this some type of over flow from the humidifier? If so...\015\012\015\012 I would suggest run ... Air Conditioners

Furnace I have carrier 8000. We were told the batteries were dead and that was what was causing the furnace to kick off and not run at night, When we get up its 63 degrees but set on 69. If you turn the thermostat off and then on again it will work ok for a few hours. then it happens all over again. you can start it manually but it won't come on by itself, then it runs for a few hours ok and repeats at night it goes off...We repalced the thermostat, but it still is the same.


Change indoor sirkit board. ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

Air Cools well but after about an hour, water starts coming into the coach through the discharge air side. Unit does not freeze up but if I shut the unit off, the tray that holds the water drains quickly, but doesn't drain well when the A/C is running. I always run it at high speed initially, though when you put the AC on Auto fan, it starts at high speed anyhow. This unit is in a Newmar Mountainaire 40' diesel pusher motor home


Your evaporator is probably dirty and is blocking some of the air flow so the air has to move around the coil and starts coming in through the condensate drain holes. That stops the condensation (water) from draining out the holes because the air is ... Dometic Rooftop RV Air Conditioner

Hello I have an LG window unit, model LWHD8000RY6 I hooked it up yesterday after having it in storage for the winter- dry, clean storage in my basement. It worked for about 2 hours, then the compressor turned off. The fan still runs, all of the display lights & switches function. I can hear the compressor trying to turn on, but it gives a quiet click-hum and then stops. The fan is still running, but no cold air. Any ideas?


... LG BG8000ER Air Conditioner

Leaking When I turn the air conditioner on and let it run there seems to be a hug puddle of water on the floor when I come back to check on it. The dehumidifer is not turned on. What could be causing the water?


... Haier HPM09XC5 Portable Air Conditioner

My LWHD8000R LG windows unit just started spitting water. It's been operating just fine for quite awhile. I checked the drain pipe area and cannot see any clogging where the pipe attaches (though I have no pipe attached). I opened it up and cleaned it up as well as I could, but it will not stop. It starts building up water again spitting after running for about 15 minutes. It is tilted properly in the window. Any ideas? Can I make some sort of makeshift drain pipe for it?


Thanks for your question!\015\012I'm sorry that you haven't received an answer yet.\015\012The response rate on FixYa FREE questions is usually over 80%, but sometimes questions go un-answered when:1. the question is unclear, incomp ... LG LWHD1800R Wall/Window Air Conditioner

Outside inverter unit keeps running hours after the ac unit has been turn off - Try shuting down the mains supply but it keeps running after the switch is turned on.


Did the indoor unit ice up also?sounds like the compressor contactor/relay has become welded&stuck.change contactor. ... Panasonic Air Conditioners

My Delonghi DEM10 compact dehumidifier has stopped collecting water. The unit starts and runs fine with no change in noise, but after I left it running for 3 hours in my bathroom, it had not collected any water and the air in the room still felt damp. I have checked and cleaned the air filter, but this has made no difference. Any advise gratefully received.


Hi,\012There are many reasons why a dehumidifier will not work or collect water.\012Here is a tip that I wrote to help ... Air Conditioners

Excessice Drainage I have had my portable airconditioner since 2004. It cools perfectly fine but the problem is, recently when I run it, within an hour of running there is a large puddle of water on the floor and it continues to pour ot water if I dont shut it off.


This may be normal for your area if there is excess humidity.Try finding the drain hose and redirect it somewhere.If the air conditioner is working (cooling) then that would be the problem.If not cooking well, then most likely you n ... Air Conditioners

Model ASH 06LLs1 Serial # GR29518 2 years old. Was freezinfg up in front grill. Water in pan, so we made it tilt much more so water drains quickly. Befoe it would run, cold air and freeze. Defrost, wait 1-2 hours and then run cold for 1.5 hrs and then freeze up. Now AC not going on at all, no fan or warning? We re-set buttons on cord..no good ? BTW, what is the BTU size of this A/C ?


Hi\015\012\015\012The issue with your Air Conditioner can also be due to thermostat failure or due to a blown fuse. The thermostat is connected to the compressor. It won't cool if thermostat is bad. \015\012The usual terminals on th ... GE AJCQ08ACB Air Conditioner

We have a weather king select 90plus not really sure of the model number but when we turned it on it was running fine then all of a sudden the outside temp was 90 and inside temp was 81 and it could get cool inside then we went downstairs and saw water at the bottom of the unit and the unit was sweating so we thought maybe it froze up,cut off unit for a while then cut back on and still water running from unit, company can in and said we have a leak somewhere and might need a new coil not sure th


Is this an upflow furnace? If it is, there needs to be a "P" trap in the condensate drain line. You need to check to see if there is. A "P" trap is a "U" shaped\015\012tube or fitting in the condensate drain line. The first time you run your un ... Air Conditioners

Re: Bosch Highflow Water Heater - model YS2433R. Hot water runs for 1-2 mintues and then turns cold. Burners turn off. Display flashes "14" (error?). Started when winter set in. Ph. 64 4 5666948


Q. \015\012 Burners Do Not Ignite When Hot Water Is Turned On?\015\012 \015\012\015\012\011\011\011\011\015\012\011\011\011\011\011\011A. \015\012\011\011\011\011\011\011\015\012 ... Air Conditioners

AC Condenser motor will stop at 1pm but inside unit is still running but no AC. If I turn the AC unit breaker unit off and then an hour later turn it back on. The unit runs fine all day until 1pm. Had a tech out and he checked the system and it's fine. He said I may have a thermostat problem and he would need to see the manual. My theromastat is programable (Carrier, 4 zone, Comfort II) with 3 remote temp sensors. How do I troubleshoot this?


I am having the same problem. The unit out side is off and I can have the thermostat off and it keeps blowing in the house. The weird thing is it turns it self on and off inside every 15 sec or so.. How can I stop this or why is it doing it? ... Carrier 38CKC060 Air Conditioner

Im using panasonic split ac cs-pc12jky and my unit turn off after half an hour with timer blinking when i turn on the unit it runs for half an hour and it tuns off again with timer blinking.......and the service person dunno whats the prob, they changed the sensor still i m facing the prob.........what to do?


... Air Conditioners

I have an Amana central air/heat unit. Model PHCB10C1 Serial # A040900070 Manufacture # P1219409C, Cat # 81K95. The problem I am haveing is the unit will not kick in(heat). When I turned off the main pwer and let off for about a hour and turned back on the unit ran fine for a couple days. Now the unit will not kick in at all even after turning the main power off and on to reset the unit. I have a brand nre thermostat in the house. When I turn the fan from auto to on the fan runs and blows out


... Amana Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0805 seconds