Having problems with your Air Conditioners ?

Fan will not start

\015 This is a brand new unit. The compressor will start but the blower will not start?\015

Answers :

Some things you could check first would be to make sure you got all the packing out of it. May just be something blocking the fan blades. Make sure you have the right power supplied to it. Probably 110v 60 cy with a ground which is the normal house plug in the USA. If that's not the problem, I would call the place you bought it from and tell them what's going on with it. If you don't get help there, call the manufacture. In most cases they will have you return the unit for a new one.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Furnace fan won't turn on sometimes. The fan will start and when house reach set temperature, fan turn off, and will not start again. On the control panel I move the switch from Auto to On and hear a loud noise for about 3 sec. fan will not start. I will wait for about two hours and the fan start right up. I have to do this each time.


... Air Conditioners

The outside unit is no0t able to start the fan spinning on its own. I have been able to manually engage the outside fan by turning the unit off, turning it on, and then manually spinning the fan when it starts up. The unit will then engage the fan and runs fine until the next cycle when it cannot start the fan on its own again. Can you tell me what part needs to be replaced and about how much it will cost?


Hi!!\015\012\015\012The part you need is called STARTING CAPACITOR and it is located in the same compartment where the electrical connectors are in the outside unit. MAKE SURE THE POWER BREAKER IS OFF before opening the compartment. and befor ... Air Conditioners

I have a Dometic 579 Series Brisk Air AC. The model Number is 57915.531. When I turn the fan on, nothing happens. If I reach up and turn the wheel blower the fan will start up and everything works. I replaced the fan motor and put on a new capacitor part # 3100248.412 was supplied. The fan still will not start on it's own. I still need to turn the wheel blower to get it started. Help!


My sheet shows part # 3100248.420 as fan run capacitor.You may have an updated number. Check voltage outputs labeled on it are same as on old one, and double check wiring is correct, to and from capacitor. Be careful not to mistake compressor start c ... Dometic Rooftop RV Air Conditioner

My compressor unit outside runs and cools Freon but the inside blower has a problem running. the model # is 2TEE3F31A1000AA. The fan control, in fan run control mode, shows a bright green for the fan LED and the CFM selection LED varies with the rotational speed of the fan. The motor tries to start showing , initially, a jerky back & forth movement. It squeaks some and may, or may not, start rotating. If it starts the CFM LED goes bright/on no flicker and the motor runs briefly (5 seconds) then


Hi, from what you have told me, you are loosing the bearings in this blower motor along with windings. This motor is rubbing the blower housing, tight when you turn it, and when it jerks when it tries to start tells me that you have burned or very we ... Air Conditioners

Our evaporative cooler fan does not start when we turn on our unit - it will run if I get up on the roof and start the fan blades spinning... We could smell a burnt motor smell when the problem started. Is it just a fuse? or is it a new fan motor? We just spent $600 to replace the circuit board and the solenoid - hoping to avoid another big bill...


Hi,It is just the circuit problem.Not fuse not motor.From the circuit board to the fan there is no start flow of current passing on to spin or to make it start.Check the flow of volts out of the board.Please do rate the solut ... Air Conditioners

The fan on the condensing unit isnt working it works for awhile and then shuts off,then the compressor starts to work by itself really hard and the whole condenser heats up really fast so I turn off the breaker and start it again but the fan makes and electric humm and I have to push start the blades to get it to spin and then it will work for awhile and then the fan will stop again after about an hour and then same thing happens


Does the fan turn freely or is it hard to turn by hand? If it is hard to turn the fan motor may need to be replaced. If it isn't hard to turn then check the fan capacitor. You can test it with a multimeter or take it to a heating and air supply and g ... Goodman CLT36AER36 Air Conditioner

Amana Portable AP125D mine is doing the same thing as another person said i noticed the exhaust fan would occasionally start to speed up to fast go into warp , then start banging around. i stopped using it, before the fan broke up, but unsure what the problem is. or what needs replaced. the blower fan or some circuit controller? and no nothing was dropped into the fan . its been it the same place and never moved. I think this is a problem with this unit. whether its the amana name or under


... Amana Portable Air Conditioner

When calling for cold air, the fan in the cooling unit hums, but does not spin. With a nudge, the fan does spin. Looks to be smooth and normal speed. However ambient outside air 80 degrees. the air through the register is 72 degrees. Is there a switch that will not allow the fan to start on its own if the coolant is too low? Do I have two problems, fan starting AND insufficient cooling? Unit worked well the last two days.


Sounds like start capacator possibly bad ... Air Conditioners

I have a Carrier 5 ton Air Conditioner -five years old. I turn on the thermostat and the blower comes on in the house then the compressor engages, but the fan does start. I can manuelly, start outside fan by using a long screw driver to turn the blades. Then the fan begins to turn slowly until it reach a faster speed. But I do not beleive that the fan is turning as fast as it use to. I go back into the house and after 15 to 20 minutes the temperture has not dropped. It apprears to stay a th


... Carrier 38CKC030 Air Conditioner

The AC unit turns on and I can cycle through the options in order to adjust the fan speed however the fan does not start in any of the three settings. The ac unit produces cold air, however the fan does not run. The unit sounds like it trys to get the fan to start however instead of blwing air it produces a funny smell. Any suggestions?


You say the unit produces cold air ??? where are you getting the cold air from???\015\012If your fan does not run in any speed F1, F2 F3. and a funny smell sounds like the motor is bad\015\012Mine works in F2, F3 but not in F1 ... Kenmore 75085 Air Conditioner

My webasto diesel heater starts up, runs for a few minutes then pumps goes faSTER AND fan revs up. then the pump stops. after the fan winds down then the fan keeps going and the pump starts up again, it runs for a while then pump speeds up , fan revs up again and repeats itself 3 times then shuts off.


... Marine Systems Webasto FCF005000GS Air Conditioner

I have a goodman 2,5 ton outside unit, i cant get the compressor to start even with replacing the start capacitor and using a super start on the compressor side of the capacitor? normally i wouldnt have a problem with this kind of repair but im getting power feed back through the cooling fan motor even with it unhooked from the start/run capacitor enough to start the fan slowly. i havent seen this before


Check to make sure you have 220 on both sides of contactors, double check wiring at capacitor. you can also check continuity between all three post at compressor , make sure power is off and wires are disconected, if you do not get continuity between ... Goodman CLQ36AR49 Air Conditioner

My fan will not start, if I take a stick and spin it it starts. I have replaced the fan motor, capacitor and start relay. Even bypassed the start relay, all have same problem. I had 2 cousins that have been in the HVAC field for 20 plus years each and they dont know the problem.


Supply the fanmoter from a completely seperate source of power and confirm that it is working. If it works, look at your supply board and contactor relay if there is one. ... Air Conditioners

Turn the unit on, the fan runs, and when the compressor tries to start the fan slows down and the compressor will not run. After a few seconds the fan speeds back up. I put an amp meter on the compressor lead and when it tried to start I registeres 41 amps. Is this a compressor or capacitor problem?


Sounds like you have a bad capacitor, if it's not tripping the breaker it doesn't sound like the compressor is drawing LRA unless the breaker is oversized for the condenser. ... Air Conditioners

On the Heat Cycle, the compressor buzzes loudly before the fan starts. When the fan starts the compressor buzzes loudly then as the fan gets to speed, the noise stops.


Bad start capacitor or run capacitor. ... Ruud UPMC036 Air Conditioner

The condenser fan does not come on when the compressor starts. When the system calls for cool air the compressor starts but the condensor fan does not. I replaced both circuit boards and the condensor fan motor.


Most of the time the capacitor is faulty. or bad contactor. Circuit boards on a condenser unit? whats the world coming to? ... Goodman Air Conditioners

Fan will not start. Sounds like it is coming on, I see the relay pulling in for the unit, hear it start up, but the fan will not start.


You will need to check to see if fan leads(black and white) are getting there voltage at the top of the contactor. it should have a 5mfd capacitor to the left of the contactor make sure both leads are hooked to it. More then likely the motor needs to ... Air Conditioners

I have a Coleman Evcon gas furnace model# DGAT095ADA last year I replaced the T-O-D #60T82 - 313675 fan switch and works fine. This year the unit started fine, but slowly started taking longer & longer to heat up, then finally not heating up enough to trip fan switch. Manually tripping fan switch resulted in some warm air through system, but not enough to heat a house. Gas comes on and is blue what would be my next course of action ?


... Air Conditioners

Coleman mach fan runs fine but A/C hums intermittently like it wants to start but won't. I'm running it with a Honda 2000 generator. Generator ran out of gas, when I restarted the generator the A/C would not run - stalls out the generator. I replaced the start and run capacitors on the A/C, hook up the generator and it ran fine until the generator ran out of gas. The A/C would not start up only hum intermittently - same problem as before replacing capacitors. Waited several hours with the fan on


The issue with the generator that gets low and high when it start running out of gas that effect the A/C and result of high voltage getting to the unit and burn the capacitors and it should by saved by the fuse make sure that the gen not run out of g ... Coleman Mach III Air Conditioner

Fan won't start. I turn my thermostat down and the compressor kicks on, but the fan won't start and immediately get's hot. Is the fan motor burnt up, or is there another problem I should look for?


One of the first things to check if your condensing, or outside units fan wont come on, The capacitor, or the fan motor is usually the problem. Turn off the disconnect, open up your access panel and the capacitor looks like a silver cylinder, it ma ... Goodman CLQ36AR49 Air Conditioner

Fujitsu inverter air cond. Just stopped working properly. Model outdoor AOT30PMAL indoor unit AST30PBA-W. Code oper. Red led flashes fast continously green led (timer) repeats 13 slow flashes. After power reset it takes rem. Con. Commands however while inside it looks normal the fan in outdoor unit starts but compressor only makes attempts to start. After a number of series of 3-4 starting attempts it stops and fan stops. Three way resistance test does not indicate open or short circuit compress


It sounds like your inverter is at fault. You will need an inverter tester ( most good service techs will have one ) to prove that the output to the compressor is correct. If the inverter is okay then it will be the compressor at fault with a locatio ... Air Conditioners

I have a 561c central air unit. I just replaced the fan motor and capacitor 6 days ago. The unit ran great for just that long now the fan won't come on and the outside unit is hot to the touch, I can assist the fan and it starts and runs great until it reaches the thermostat temp. When it turns off it won't come back on. Is it the start relay switch?


Sounds like you need another capacitor since it will run if you turn it by hand to get it started. If you have a clamp on ammeter check the current draw on the fan motor. ... Air Conditioners

The fan of my ac home unit, doesn't start. I hear the noise and the fan start moving slow but doesn't go thru. I rmove the fuse, make some rounds to the fan, after that I plugged the fuse,and sarted working and cooling normal. but after 2 hours, stop and I've the problem again.


Most compressor units have a double capacator . If one half goes bad,\015\012either the compressor will run without the fan, or vice versa. Those big capacitors can be nasty. First step on any system with\015\012capacitors is to short them out. Use a ... Dometic Rooftop RV Air Conditioner

The interior unit comes on normally, but the exterior unit - compressor starts - fan does not. Fuses check OK - compressor stops in short time. Fan never starts, just a hum, and hot to touch. Could the fan be the problem, or starter relay??? Help please.


Make sure the fan turns freely. No obstructions or bad bearing. And check the capacitor ... Frigidaire Air Conditioners

Fujitsu inverter air cond. just stopped working properly. Model outdoor AOT30PMAL, indoor unit AST30PBA-W. Code oper. red led flashes fast continously, green led (timer) repeats 13 slow flashes. After power reset, it takes rem. con. commands, however, while inside it looks normal, the fan in outdoor unit starts but compressor only makes attempts to start. After a number of series of 3-4 starting attempts, it stops and fan stops. Three way resistance test does not indicate open or short circuit c


Hello, my name is Heath and it will be my pleasure to assist you. Try using a hard start capacitor on the compressor. It sounds like the compressor is having a hard time starting and overamping the circuit. If you get a hard start capacitor it may he ... Inverter Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific