Fan no trabaja en alta velocidad

\015 Ok tengo un sansum ms09tw y el fan no corre en hi, que devo de hacer . gracias\015

Answers :

No Fan problem could be Cleaning problem. Check to see if dust build up around fan and flanges are clear of dust.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Fan no trabaja en alta velocidad


No Fan problem could be Cleaning problem. Check to see if dust build up around fan and flanges are clear of dust. ... Haier Energy Star ESA3183 Air Conditioner

Broken Fan Good Day! My problem is about my fan..though its a McQuay brand..can I change the fan even if its in different brand? I can see that the LG fan the split type AC is really the same as the McQuay. AS of now I just put a mightybond to connect the fan because it was broken. And I need the cover too for the fan? Can you help me with my problem? Hope to hear an answer very soonest. Mr K


Send fan cover size i will try2 send u ... LG LS-L1210CL Mini Split Air Conditioner

I installed Minka remote controlled Ceiling fan for a friend. The fan itself has 4 wires, black,orange,white, & blue. The remote unit has black, white, & blue wires to connect to black, white, & blue wires on fan, and black & white wires to connect to electrical wires in attic. The remote operates the fan functions correctly, but the lights on the fan stay on all the time, with no effect from the remote. I have no manual, and had no place for the orange wire on the fan to go to.The model number


The connections you need to make are \015\012\015\012\015\012Motor to Receiver Electrical Connections: Connect the WHITE \015\012wire from the fan to the WHITE wire marked "TO MOTOR N" from the \015\012Receiver. Connect the BLACK wire from t ... Air Conditioners

Replacing a o smith fan fse1026sv1 into York ac unit model H2RA036s06A. Old fan had two hot legs, one from capacitor, and grnd. New fan has two brown, old fan one, that go to capacitor. Tried wiring browns together put fan shut down after about 5 minutes. And it was hot all around the top above the coil. Any suggestions?


... Air Conditioners

Noisy fan grinding rolling sound when fan runs.. assuming rusty ball bearings since it was outside.. and manually turning fan replicates noise. any advice? i also see a clip on the forward facing fan that is oxidized or rusted. seem to be a stopper on the fan axle. not sure


... Kenmore Single Room Air Conditioner

I have a split system sanyo heat pump model # kmh0922. The evap. fan will not come on when called for in fan mode. When i put it to heat the indoor fan will also not come on. The compressor runs but the reversing valve seems to stay in the cooling mode. When it is put into cooling the indoor fan goes off after 15 seconds and will not come back on. (The condenser fan and compressor seem to act normal in cooling.) Any ideas as to what the problem could be? Thank you, Mike


Sounds like the blowers capacitor has gone bad ... Sanyo Air Conditioners

I have a U-42 Janitrol gas furnace that will not start the exaust fan nor will it light the burner but the blower fan will come on. I have two identical units. I've swaped the exaust fans and the unit that was working strarted the other exaust fan - put the known working fan in the non-working unit and it still didn't come on. I switched the thermostats and still no positive results. Any suggestions?


... Air Conditioners

I have RUUD and just replaced the condensor fan motor with a 5 wire Protech....the old fan was wired with black connected to contactor, orange to one side of cap and brown to the other side of the cap.....The new motor is a five wire...I have black connected to the connector, orange to one side of cap and purple(to change direction of fan) instead of brown...now i have a yellow and brown wire left over....Now when I start the unit the fan will not spin unless i turn the fan blade manually....am


Look on the side of the motor it will have a wiring diagram your fan supplies voltage to the capacitor its self so two of your wires go to the capacitor not just one. good luck ... Air Conditioners

I have a Coleman Presidential 7670 furnace in a mobile home. customer said it came on a couple of times by itself. I ran new wire, fan won,t shut off. Replaced fan switch, fan still won't shut off. Replaced t-stat, same problem. This is an older unit and has no board it has a fan switch a low limit switch, i,m guessing the other is a high limit and a fan relay. I have no schematic and am very frustrated can anyone help me please. Thanks. Brian from california


Brian, it sounds as if possibly the fan relay is stuck however, if the fan will not shut off I would suggest the following, Follow the wires from the fan to the relay on the relay disconnect the fan wire there and see if the fan shuts down if so t ... Air Conditioners

The outside unit is no0t able to start the fan spinning on its own. I have been able to manually engage the outside fan by turning the unit off, turning it on, and then manually spinning the fan when it starts up. The unit will then engage the fan and runs fine until the next cycle when it cannot start the fan on its own again. Can you tell me what part needs to be replaced and about how much it will cost?


Hi!!\015\012\015\012The part you need is called STARTING CAPACITOR and it is located in the same compartment where the electrical connectors are in the outside unit. MAKE SURE THE POWER BREAKER IS OFF before opening the compartment. and befor ... Air Conditioners

The light fixture needed to be repaired. It never worked when I bought the house. New light bulbs didn't worked. I replaced the two ceramic light switches that had corroded wiring and reconnected blue to black and white to white. I have a dual wall switch that controls the fan and light. Now the light only works when the fan is on. The light on my other identical fan works without the fan on. Is the wiring problem in the fan or switch. The switches are different.


If its a duel switch that controls lights, and the fan seperately. sounds like the power for the lights is going directly to the fan, and therefore making the lights work also. also check out switch, make sure power is only going to the lights, with ... Air Conditioners

I have a Dometic rooftop Air conditioner in my RV When I turn it to low medium or high the fan run the same speed and when I turn it to AC it will run for about 5 min then the fan will shut off but the compressor keeps running I turn it off for a min or so and everythings comes back on. Turn it to the fan only side and the fan will run for 5 min then shut off a min later it comes back on then back off and on in fan only side.


Bad fan motor I suspect The windings are bad causing the motor to over heat sending the motor into thermal overload. would suggest the replacement of motor. Good Luck on repairs\015\012\015\012Dave ... Dometic Rooftop RV Air Conditioner

I have a Honeywell oscillating quiet cooling tower fan that was bought two years ago. Loved it, till yesterday it just stopped working. the oscillating feature still moves, but the fan does nothing. the buttons still beep and turn on and change while plugged in, and it sounds like something is working...but obviously not everything cause the fan doesn't fan. Is it fixable? Should I send it to the manufacturer? Or just eat the cost and buy a new fan?


Could be fixable but until someone determines the problem there is no way of knowing if it is fixable. Could be a broken wire between the selector switch and the motor or the motor itself could be bad.When you are trying to operate it does the ... Air Conditioners

Intertherm model P853A5 older style AC unit fan will not start to rotate when thermostat control set to cool.I have a feeling that it might be the electric motor. I removed the screen and rotated the fan manually looking for a bearing problem but found the fan rotated smoothly without any problems.When I set the unit to cool I obsereved the fan motor trying to turn and then it stopped aplost like it could not handle the load of the fan.


This is most likley the capacitor. Be very careful when changing it out!!!!! Make sure to use an insulated device to discharge it first before touching it!!!!!!! To discharge it place insulated device across the two spade connectors on top. ... Intertherm Air Conditioners

I had a Panasonic bath fan installed the week before Thanksgiving. It was represented that this fan was virtually silent. It is however, noisier than the 22-year old fan it replaced. My contractor tells me that the problem is that the vent exiting the fan is vented by a 3" (too small) flexible hose that travels into the ceiling and ties into a larger duct that isn't reachable. Panasonic fans are at their best when they have a 4" vent hose that travels with a minimum of bends for a total lengt


Vibration noise is usually due to inballanced, or damaged fan blade. \015\012\015\012Take off the coveer, make sure its installed properly, the blade is not cracked, and check for ballanced motor/bracket/blade.\015\012\015\012 ... Air Conditioners

Sometimes, when the inside blower shuts down, the outside compressor and fan motor continue to run for some time. Other times, when the inside fan motor is running, the outside fan and compressor motors are not ... if I press the outside reset button, it starts up When both inside fan motor and outside fan and compressor motors are running, it works fine ... warm air blows out of registers. Other than that problem, both units work great!


Sounds like you have a dirty condenser. You are going to need to disconnect the power at the outside unit on the wall by pulling the fuse block out. Take a good look at the louvered covers that are attached to the outside of the unit. Remove the scr ... Ruud UAKA060 Air Conditioner

A mate has a fujitsu ast24rba-w, the outdoor unit runs but the indoor fan won't go. Found indoor board buggered so I replaced it, fan still no go. Got hold of a fan that I know works and still won't run!! Checked the start capacitor and that meters ok. It won't even run on fan only. From what I can see the fan should run, there is nothing left to replace. Any advice would be greatly appreciated!!!


... Fujitsu 24C1 Air Conditioner

Furnace fan won't turn on sometimes. The fan will start and when house reach set temperature, fan turn off, and will not start again. On the control panel I move the switch from Auto to On and hear a loud noise for about 3 sec. fan will not start. I will wait for about two hours and the fan start right up. I have to do this each time.


... Air Conditioners

I purchased a Hunter fan model "Regalia". This fan does not come with a remote. I purchased a Hunter remote control and installed both the fan and remote. My problem is that the light and also fan turn on and off by itself. I was told that the remote could have a problem, so I replaced the remote with another Hunter remote model and the problem is now worse. Should I replace the fan? or what do you suggest I do.


... Hunter Air Conditioners

No Fan Somebody junked this thing, I guess because the fan doesn't work. Does anybody have any experience with the fan? I figure it has to be the relay (but I hear a click), the capacitor, or the fan motor (fan rotates freely). Before I perform surgery, I'd like to clarify the diagnosis. Thanks.


Danby DPAC8399Aftermarket (Post Warranty)Parts 800-496-6049 CanadaAsk for the motor start capacitor, cost me $38 with shipping ... Danby DPAC8399 Air Conditioner

I have two Harbor Breeze Triton (Item #233576) ceiling fans purchased approximately 3 years ago. Neither have pulls, so the only way I can change the fan speed or dim the light is with the remote (the light can be shut on or off with a light switch, and I can also turn the fan off completely, if I want). A few weeks ago, one of the remotes stopped working...replaced the battery, etc., and nothing worked. I took the remote from the lesser used fan, changed the dips, and use it for that fan


... Air Conditioners

Ihave a Day & Night Furnace M/N:58GS050-3 Series 301 S/N:Z33A65482. My problem is with no wiring whatsoever landed @ terminal strip fan runs @ high speed constantly.With stat wired up & a call for heat I get no spark,just fan(fan switch -auto). 24vac is present into circuit board from transformer, but drops out to 15.xx @ R & C.If I apply 24v directly to R along w/other wiring,fan stops,but after ignition main burners light,fan never runs.


... Carrier Air Conditioners

I have a ceiling fan with lights, last night the fan was turned on for the first time since summer, the remote is over the light switch. The remote to turn on the lights is used normally. Since turning the fan on last night there is now a humming noise even without the lights or fan on. Is this a problem with the fan or remote. pleas help the noise is low but consistent.


There is a small relay in the ceiling fan causing this noise, try turning off all power to the ceiling fan and allow it to set for a couple of minutes. Turn it back on and see if it goes away. If it does great. if not, it may not be worth the repair ... Hunter Air Conditioners

Indoor fan motor continue to run even if the thermostat is in auto position with the cool and heat switch in the off position. The furnance don't have a fan on and off switch in the furnance like most. The only way to turn the fan motor off is to turn off thr high power switch. I change indoor fan relay but the problem still exist.


Try this, disconnect the fanwire (green) on the furnace, if it shuts off then the hot wire from the thermostat is touching the green wire or bad thermostat. Thank-you-very-much! ... Intertherm Air Conditioners

I have an intertherm electric furnace FEH-A020, with multispeed blower installed when A/C added. My problem is blower operation. at the end of the cooling season with fan set to auto operation the fan ran continuously. Now that I've turned the unit back on for heat the blower will only function with the switch in the on position (continuous operation), in auto mode the heating elements come on with the signal from the thermostat (Honeywell CT3400), but the fan does not. I checked the fan relay p


The model of T-stat you gave comes up as a discontinued model on Honeywell's web site, but it looks to be a manual stat that type of stat would have to be wired with a summer winter switch with electric heat, allowing it to turn on the fan with a cal ... Intertherm P3RA-048K Air Conditioner