Having problems with your Air Conditioners ?

The unit has stop cooling

\015 The unit runs but does not cool\015

Answers :

Does the compressor start at all?

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Hi. I recently installed 1.5 T, 3 * Split AC, LG. Whole day the AC works fine and no problem in cooling too. But once in 2 day outdoor unit start making thudding noise continously and does not stop for 4 to 5 second and after that indoor unit stops cooling and just fan runs. No cooling is done after that and room temperature keep increasing. The green LED of compressor in indoor unit is ON, compressor does not work. To achieve cooling again I have to switch off whole unit for like half an hour a


HelloSounds like the compressor is shuting down on high heat.There could be a couple reasons for this.1 Check that proper voltage is being supplied to compressor.2 Freon level may be low.This would be a service call.3 Ba ... LG Air Conditioners

Cools for few minutes then stop cooling....Hi my unit GE (APH10AA) Air Conditioner, only cools for 10 minutes and then stops then is the fan that runs forever , with out getting to cool again,plus the back of the unit ,the vent takes out lots of VERY HOT AIR, my room will get so hot ,what I can do to fix it? please help


... GE APH10AA Air Conditioner

Unit leak at high pressure port. repair man replaced valve charged unit.cooled for a short time then stopped cooling.another repair man found low coolant,thought evoperator leak to be the cause. injected stop leak [944 kit super seal hvacr 1 ton to 5ton]. unit cooled for short time. now does not cool. runs and sounds good but no cooling.


Sorry about your problems.The StopLeak is expensive and does not work on leaks larger than 8 ounces per year.Neither of these "technicians" confirmed the location of the leak and repaired it.When the vacuum was done on the system a ... Ruud Air Conditioners

Unit cools for a few minutes then stops cooling. Even fan stops blowing air but the unit remains 'on'


Unit may be short of gas. will run for a few mins before low pressure switch turns the compressor off. you will need to get an engineer to check gas pressure ... Samsung AW1003M Air Conditioner

I have a problem with split-type ac unit, when the unit stops due to cooling, the unit doesnt turn on to cool operate again. I have to set the control to start the unit again. Someone recommends me to change the capacitor of the outdoor control unit. Or maybe I have to replace the a/c unit?


First of all I would change out the thermostat since you say you have to turn the unit on at each use. The capacitors only assist in the start of the compressor and fan. You main issue seems to be the activation after the unit has been off. I thin ... Carrier BCA101R Air Conditioner

My unit stopped blowing cold and started blowing hot.i turned off unit looked into furnace and saw pilot was still lit.i put out gas pilot and turned unit back on and it is blowing semi cool air (like fan)but not cool as it should.checked outside ac and it is running....munual says to turn unit off for 2 hrs and if it does not do right then it is compressor.we are currently in the 2 hr process. Any help would be helpful at this point.is there a reset switch or anything I could do to troubleshoo


100 degree temps/high humidity puts an extreme load on air conditioners - but if everything is right with the AC - 'overheating is not a big problem.\015\012\015\012The first thing I would check is whether or not the compressor is running ... Weather King 10AJA4201AH Air Conditioner

Fedders Model No. A7U12W2A-A, 12000btu airconditioner. The unit has been cooling satisfactorily for two to three years. Today the unit was cooling and suddenly there were a couple of reasonably loud knocks and the compressor stopped cooling. The fan continues to run. In about five minutes the cooling comes back on. The compressor runs for abut four minutes and shuts down. Earlier today we had a power dip without losing all power.


Hi, the power dip when translated means low current actually affected the relay starter which is situated beside the compressor. Now the relay starter works and stop intermittently which is why the Compressor cools whenever it works and does not cool ... Fedders Air Conditioners

My cocept 1000 ac unit quit workimg last night .the unit was very hot and the fan outside stopped turning.i let it cool and restarted the unit ,but the fan turned slowly and stopped again.what can i do?


IF THE FAN TURNS FREE (USE A SMALL STICK TO PUSH ON THE BLADE) there is a\012 capacitor also, that runs the motor that could be bad size is on it \012average size is 5 -7 UF . these motors are expensive nowadays so you \012want to take care of them ! ... Air Conditioners

I have a a/c unit mitsubishi electric ms-12rv r22 when starting it on cooling or heating mode it stops after 30sec and the operating light flashes and the otdoor unit does not run the indoor unit fan stops can you help thanks


Hi,Here is where you can find all the info you will ever need about Mitsubishi Air Conditioning units...Check out this tip that I wrote about that...Mitsubishi Air Conditioner Troubleshooting and Repair ... Mitsubishi MS12TN Air Conditioner

I have a 2 year old Duo Therm 15,000 btu Heat Pump AC unit in my RV. The compresser will not come on or even try, in either cool or heat mode, the fans runs in either auto or on position. I have a wall thermastat, all wires & connections at the thermastat and the controll box look good. The units was running fine, with no prior symptoms and then it just stopped cooling. I have a strong electrical background with all the meters, I am just not famaliar with RV AC units. Bud De Fore don


Hello Bud,First of all, is your wall thermostat a digital thermostat, like a 4 or 5 button Comfort Control Center? Is the ambient temperature under 40 degrees?Is your fan still able to run, are you able to control ... Dometic Rooftop RV Air Conditioner

Duo-therm 1350 ceiling, ducted AC(model 57915.622) in a 2000 HR 29' 5th whl. original unit worked fine but just failed - ''compressor leaking oil''. replaced with a used unit with a new or rebuilt compressor. this replacement stops cooling after about 30 minutes. turn it off and wait a while and it cools again for a while. day temps in the mid 80's and mid to high humidity as in michigan. repair guy sticks his hand up inside the unit and sez ''no icing''. he wants to install a new duo therm and


... Air Conditioners

Hello, I have a Ruud 10 seer unit in the condo i rent...it frequently stops cooling. The fan inside never shuts off, but the unit outside won't come on often enough to cool to the temp on thermostat. When the A.C. guy comes all he does is drain some water from the inside unit and it works fine for awhile. Can you explain how I can do that myself...as it's very hard to get him here. Thank you.


It sounds like the air cond is freezing up, and as he melts the ice off he evaporator coil you will have air flow again. When the evaporator, (which is the coil that absorbs the heat from your condo) is frozen over, no air flow can pass through it. ... Ruud Matching Split Air Conditioner

I have a Friedrich 13,500 BTU WallMaster. The air conditioner stops generating cold air and seems to use the fan only on a regular basis. The front panel shows that the unit is still in cooling mode but the the unit just blows out warm air no matter how low I set the temperature. Then out of nowhere the unit will start cooling again. I know the problem is not the filter. Does anyone have any ideas? Thank you.


I'm having the same issu!!! It's horrible! ... Friedrich WallMaster WS07A10D Air Conditioner

The cooling unit outside is not working. Its a Midea split system and the indoor fan unit works for a bit until all the lights flash together and it stops responding. The external unit (that does the cooling) is not working


Your compressor may have seized up or burned up or blew a fuse. you may want to call an ac tech cause you cant really do much yourself with it. if the compressor is seized you may be able to unstick it by taking the back off the ac unit and hitting t ... Midea MWB-05CM1 Air Conditioner

I have a frigidaire wall mounted ac unit. It isnt cooling like it should be and when the motor tries to come on my lights dim and there is a humming noise for just a few seconds before the hum stops. The fan runs and will blow "cool" air but not as cool as it should be. What is my problem here? I dont know the model # for my ac unit, it is probably 8 yrs old though.


... Frigidaire FAS155K1 Air Conditioner

My ac will blow cooled air, but then the ac unit will stop cooling and just blow hot air for a while. It'll switch back and forth instead of just blowing cool air. An ideas on what the problem i


... LG LXA1230ACL Air Conditioner

I have a Daikin 4mxs32 with 4 indoor 9K wall mount units. About 3 months old. All of a sudden it stopped heating or cooling in all rooms. It works in the closest room to outdoor unit. Not at all in furthest room but does work somewhat on unit directly on other side of the wall and also somewhat on unit directly on other side of wall behind closest unit. Then I also noticed that when I turn the furthest unit that somewhat works off the close unit that somewhat works goes up in discharge temp in A


... Cfm Daikin R410a Split System Air Conditioner

Amana Cooling Condensing Unit fan stops spinning after 15 mins


Capacitor, dirty condencer coil causing the motor amps to run too high. But most likely worn bearing on blade side of motor causing it to pull to one side causing it to over heat and shut down. Sleve bearings should have no side play. ... Amana PTH123B25AJ Heat Pump Air Conditioner

We have a split system model number S24AHP-ND6 its 7.5 kw cooling and 7 kw heating. We have been having problems with it for a while ,it has only been delivering about half the amount of air flow on cooling mode, and now it has stopped delivering cold air altogether and is only blowing uncooled air, also the outside unit seems to have stopped working too.


... Air Conditioners

Our 10,000 BTU window air conditioning unit has stopped cooling air. It will blow air in from outside, but it does not cool it. The unit is a few years old, but has very few miles on it. Shot in the dark, what might the problem be?


The fan runs but there's no cold air?. Is the thermostat\015\012knob turned to the proper setting? Is the compressor motor running? The\015\012compressor is a football-sized case with no apparent moving parts. It\015\012is located insid ... Air Conditioners

My LG art cool units stop frequently and show a code of C8. I turn the unit on and off again and then works until the next time....This has been going on for several years now, is annoying/concerning, but each time I have a professional come to visit they tell me the same thing....that the C8 means the internal fan is blocked, but if by turning it on and off the problem is solved then the fan is not really blocked and I should not be concerned. I have two art cools and this happens on both of


... LG Art Cool LA121CNP wall/window Air Conditioner

Interkool 900 stopped cooling - what to check before calling for service? The unit has worked fine for 4 years. The fan runs, but the unit does not cool the wineroom anymore.


T seems like there is a problem with the thermosat, or the compressor. Its not sensing the temperature being to warm to kick the compressor on and cool it down. OR the compressor itself id dead. Hope I could help.\015\012 \015\0 ... Vintage Keeper Interkool 900 Air Conditioner

I have a CAPF4860C6AA air cond. I emailed your tech about a problem I have but I sent it in under the wrong model.My unit doesn't cool properly. It stopped working recently. The out side fan was working but the in side one wasn't. I shut it off for about 12 hours after which I changed the air filter and cleaned the overflow unit(pump). I turned it on and it worked but not cooling right. It's freezing or something to the touch on the outer cabinet. I recieved an email from you but I wasn't sure w


May I suggest? or ask, can you feel air being pulled into the front of the unit? If so, you may have a baffle or shutter misdirecting the air flow and it is not being channeled through the vent outlets into the room. The unit may need to be slipp ... Air Conditioners

Ramsond split system ac ( 9000/12000) showing error codes P4 & P8 in cool mode . initially units operate correctly for a few minutes and then stop cooling and show the codes. continues to blink error codes after unit is shut down.


HI\015\012\015\012YOUR BROBLEM I THINK IS THE SENSOR FOR THE ROOM TEMP \015\012\015\012OR\015\012\015\012Indoor/outdoor c ... Air Conditioners

Americool WAM18 Single unit (heat/cool); operates perfectly well except that lately it started displaying an E5 error code every now and then and naturally stops cooling. Switching off and ON again generally clears the problem, but sometimes it will stop again for the same flashing error code E5. When it runs well, it really cools fast and is very efficient; has been installed since 2000 (13 years, yes!) - never had problems before this one.


... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific