Compressor shutsoff I live in the desert and when the ambient temp reaches 110F the compressor shuts on and off even though the room temp is in the 90's. It is on the highest setting. it's shaded and everything is clean. any ideas??teck rep says to take to auth. service center 80 miles away. service center refuses to work on Goldstar even under warrenty.


Answers :

Does it only shut off at 110F or will it work ok under that temp?

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Compressor shutsoff I live in the desert and when the ambient temp reaches 110F the compressor shuts on and off even though the room temp is in the 90's. It is on the highest setting. it's shaded and everything is clean. any ideas??teck rep says to take to auth. service center 80 miles away. service center refuses to work on Goldstar even under warrenty.


Does it only shut off at 110F or will it work ok under that temp? ... Goldstar R5050 Air Conditioner

We have recently had three problems with our three year old Carrier 24 ACA airconditioner that I believe has led to it no longer producing the low temp. chilled air it did when it was installed. !. water pump quit for taking water to to sewer, 2. blower fan quit(replaced under warranty we paid service call), 3 compressor froze up and service man ran cold water over it to lower temp. We live in southern In where we didn't use the unit much last year and this year we are hot. What temp. should


Your air temp should be at least 20 degrees cooler than the indoor air temp. This is ideal. But it sound like your unit is low on freon. When units get low they will freeze up. They will also freeze up if air flow is restricted on the inside coil or ... Carrier 38CKC024 Air Conditioner

I have a Duo Therm unit on the roof of our 1995 Nomad camper trailer. I think the contactors are stuck closed..here is why. When the AC unit satifies the thermistat, the fan turn off, but the compressor (Humming sound)keeps running...until I hit the AC 15 amp breaker. Even if I put the thermistat up passed the current temp, the compressor still keeps running. Where are the contactores / relays? Shal I take the cover off, and start looking around? I would expect a low voltage relay for the thermi


You can get a manual for this in the library section of the Hi-Lo Trailer Forum. I know this isn't a Hi-Lo but the AC unit is the same. www.HiLoTrailerForum.com ... Air Conditioners

The outside compressor and fan will not shut off. I have turned the thermostat system to Off and even to heat, but it will not stop. I went on a trip, increased the room temp to 80 on the thermostat and left. When we returned 2 1/2 days later, the coils were frozen and no air was comiing through the vents, even with the blower motor working. So I turned the unit to furnace and melted the ice on the coils, but had to pull the fuses on the outside box to get the compressor to shut off. Is there a


Sounds like the contactor is stuck. That's why nothing will stop the fan and compressor except killing the power to it. You should be able to get one fairly cheap. ... Ruud UAKA037 Air Conditioner

AC Compressor My A/C Compressor is not starting. My Mechanic says he has to flush nitrogen into it, remove the gas inside and then try starting it.He did this and then topped up the gas, Now he is charging me heavily for the topped up Gas. Is it right what he did to start the compressor? My compressor was fully loaded with gas prior to the service.


Sir I have lg ac split tpe 1 to 4 coomprssar and indoor raning. Only 5mint cooling only than indor unit cantny billing wat prpalm ... LG Heat cool Window Air Conditioner

HAVE A HOLIDAY RAM PUSHER HAS THREE DOMETIC 15000 A/C UNITS PROBLEM IS SOMEONE HAS GUTTED OUT AND REMODELED ENTIRE INTERIOR INCLUDING CELING . IVE BEEN ASKED TO FIND PROBLEM WITH CENTER A/C (ZONE 2) FRONT A/C HAS BEEN INSTALLED FROM FACTORY ON ITS OWN THERMO (SAYS CUSTOMER)NOW REAR A/C IS ZONE 1 AND CENTER IS ZONE 2. HIS COMPLAINT IS CENTER A/C DOESENT COOL, SO I CHECK IT OUT AND FIND FAN RUNNING COMPRESSOR RUNNING AIR MOVING A LITTLE WEAK BUT DEFINANTLY NOT COOLING. HERES THE STRANGE PART, ON


Yes, the extra ducts can certainly decrease the force of the airflow dramatically. It sounds like someone was trying to use the center AC to cool all three zones. \015\012\015\012Yes a compressor can run and not cool. You are correct in t ... Dometic Rooftop RV Air Conditioner

Room temp 78 degrees with unit setting at 68 degrees. The unit is running (i.e. compressor) but unit not pumping out cold air. To be specific the unit is pushing out cool air just not cold with such a difference in room temp and temp setting. Any suggestions other than having an HVAC service contractor out.


Sounds like it could be low on freon I believe these units have about 1.5 pounds of freon in them and are critical in not undercharging or overcharging them if it is a freon 410 ac unit the pressures should be about 135 and both lines cold if is l ... LG LAN240HSV2-LAU240HSV2 24000 BTU 20 SEER Art Cool Ductless Heat Pump Air Conditioner

I have a 2 year old compressor and about 4 year old furnance. The Evaporator coil is as old as the house at 20 yrs. My blower had burnt out and my ac was running for a long time and cause the compressor to form ice in the lines.I would say that the blower was not working for about 12 hours and the compressor never shut off due to not reaching the cooling temp in the house. I replaced the blower but notice that the air was not blowing as cold. So I had a tech come out to look at it and told me th


It's gonna be difficult to get a matching evap coil for a 20 year old ac system. Since 2006 all of the evap coil were made to be 13 seer and that caused the size to increase making it hard to install sometimes. If you are g ... Air Conditioners

Have NEC RIH-2667 Inverter Split system.I set to Heating mode,set temp to 25 degrees.The compressor light comes on.The run light flashes for about 30 seconds.Then the vent opens,the fan comes on and starts blowing out heat.Within 5-10 mins the temp on split displays starts going up.when it gets to 26-27 the run light flashs,fan stops,no heat coming out.The temp on system keeps going up to 30 degrees.it takes approx 40-60 mins to come down to 25ish the will come on again and repeat.I have an inde


... Air Conditioners

I have a Coleman rooftop rv ac unit. THe air it blows is not as cold as it used to be. the compressor shuts off frequently even if the thermostat is set all the way to coldest. The compressor will start again after several minutes and runs_air is not very cold_then it shuts off again and the cycle repeats. Is there anything that can be serviced for this. Can it be recharged with freon? Could it be the thermostat? Why is the compressor shutting off?


Try to check the condenser coil fins, there should be no clogged areas on fins so that it could properly discharge hot air which is needed to complete the refrigerant cycle. If the condenser heat is not discharged properly, hi refrigerant pressure wi ... Coleman Air Conditioners

My McQuay console water source heat pump compressor vibrates creating a noise problem. the Mcquay tech rep says this is normal. I want the compressor or unit replaced. Please advise.


... Air Conditioners

My Danby Portable AC has a flashing BLUE light Sometimes it displays a message ER04 The unit works fine then randomly the compressor turns off. We recently had a national disater here in California with a lot of smoke from fires in the air. Could this have clogged something in the unit. To take it in is impossible for me as I can not physically lift or move this device other than roll it. I really need a answer aside from the one I got that was basically saying ''take it to a tech.'' with no con


THE ER04 error is for two reasons.one for water bucket full and other is for power supply getting short in between.\015\012------\015\012IF THE WATER BUCKET IS THE FAULT the switch is more likely the cause try removing bucket and pressing ... Danby DPAC120068 Air Conditioner

Compressor outside will not kick on ?? even when i drop temp setting lower than what the actual house temp is....


Check the circuit breaker for the out side unit make sure it has power check the disconnect to see if it was put in properly if not have a service tech come out to check the unit ... Air Conditioners

Always running I just bought this house with an existing Ruud system installed and have noticed that the air is ALWAYS running. It never pushes the heat past the set temp to make it turn itself off it just runs at the set temp forever. Needless to say this is a killer on the electric bill and I am seeing if I can fix it hear before having to call in someone to service it.


Some newer high efficiency units using variable speed DC motors are designed to maintain a temp and wonrt shut off by design. Does it maintain a temp you desire ? It may be normal hard teling without seeing it. ... Ruud UBHC Air Conditioner

I have a Haier portable AC model HPAC99ER. The tank full light came on and the AC turned off. Trouble shooting guide in the operating manual says to call for service. Is there anything I can do/check before calling a service rep? this is an older unit I've had since 2004.


This unit has a tank in which the water that was condensed from the air accumulates prior to being evacuated. Normally the water in it is eliminated by evaporation thru the exhausted air but the the air is very humid the water that condenses overwhel ... Haier HPAC99ER - 9000BTU Portable Air Conditioner

I've been using this Danby Premiere DPAC11010 for months. There are no instructions for draining it, although it came with a drain spout and rubber hose. The sticker on the front says it doesn't need to be drained - the liquid cools the compressor. The troubleshooting guide says to drain it if a certain warning light goes on. I tried draining with the hose and even rolling it out onto the deck to drain it. However, it runs for an hour or so and I get the same error and the unit shuts down again.


I see no solution do I have to be a member to view or has it not been solved? ... Danby Air Conditioners

My lg wall unit (LWHD1009R) 10,000 btu the compressor keeps turning off after it gets going. even though I have it on a low temp. the comressor turns off after 5-10 minutes even though the room is not cold


My window ac 1.5ton cut off with a **** at 28 deg temp with in 3 minute .room temp is 31 deg. ac is 2years old and i bring in good working condition from my brother. it was kept idle for 1 year ... LG Art Cool LA121CNP wall/window Air Conditioner

We have: AmcorAire Duo Ductless Split Air Conditioner 24,000 BTU Cooling & Heating UCHW-H24CF2 by Pridiom. The tech says the compressor is shot, but Pridiom (who bought AmcorAire or what Amcor changed their name to or whatever) will not honor the parts warranty (even though their own web site indicates that they will honor parts warranty but not labor: http://www.pridiom.com/pdf/Pridiom%20End%20User%20Warranty%20Procedure.pdf). The new compressor will be close to $400 and the warranty on


Amcoraire Closed their doors Aug/Sept 2009. Pridiom Group started operations October 2009, Pridiom purchased Amcor parts/equipment at bank sale. ANYTHING PRIDIOM SELL'S, PRIDIOM WARRANTS to be free of defects parts 3 years/5 years compressor. It is t ... AmcorAire UCHW-H24AF2 Split System Air Conditioner

I have a new duo-therm 13500 hp a/c. When the A/c reaches the desired temp, the fan and compressor stops. Is there any way of keeping the fan on, even though the compressor has cycled off for a few minutes. Thanks Greg


Turn your fan on the termostat to on (manual) it will continue to run untill you set it back to auto ... Air Conditioners

I have a lg 1.5 ton split ac , problem is compressor trip in 5 to 10 minutes ang agin start in 10 min..i will call service centre , he wl change capactor and service indoor n outdoor unit ,but problem will same, then he will say the problem in relay (pcp) circuit. tell me solution..


First check the compressor amps and the condenser fan rotation are correct if ok check power come to the compressor without interuption (from control in the indoor unit)if the remote setting are ok correct voltage to the compressor may high pressur ... Air Conditioners

I have a 6 year old Carrier Performance 38yza. Having a problem with heat. First no heat at all heat pump or AUX. Found AUX heat strip were grounded out and have now been replaced. Second no heat pump, Compressor comes on for only 1 to 2 minutes then shuts down. Service call yesterday Tech says no signal from Carrier Programable T-Stat, jumper heat pump, low freon adds. Says T-stat bad, but puts back together. Heat pump works blowing 90 plus degree from vent works great all afternoon and into ni


This sounds like you have a freon leak. Most units never lose freon. So that is one problem that needs to be addressed. Here is some more solutions for you: Other things that will cause or aggravate\015\012ice are clogged filters, bad fan moto ... Air Conditioners

AC Out. Two year old house. Goodman A/C, two units one for upstairs. Cleaned coils of both outside unit, replaced filters, re-set breakers. Upstairs is cooling. Downstairs unit is running outside, not circulating air inside (inside temp 87). Vents inside are cool to touch, no air. Outside unit fan is pulling, but air exhaust is cool. Compressor ? Should air be circulating even if compressor not functioning. Is there anything in attic exchange that would affect downstairs circulation. Thanks.


Assuming that the 2 systems are isolated, that there isn't any cross over between the systems...It is normal for an air conditioner system, from window unit to central, to be able to circulate the air, even if not cooling. This is known ... Air Conditioners

COMPRESSOR I HAVE A 13,500 DOMETIC ROOF TOP UNIT ON MY RV. THE COMPRESSOR COMES ON EVEN IF THE THERMOSTAT IS IN THE OFF POSITION. IT WILL COME ON AND RUN FOR APPROX 5 MINS. THAN SHUT OFF. IF YOU PUT THE THERMOSTAT ON COOL AND LOWER IT BELOW ROOM TEMP. IT WORKS FINE.


Thermostat is badReplace it ... Dometic Rooftop RV Air Conditioner

I have Carrier mod#24ANA760A300 Infinity system. 1.5yrs old. Compressor nor fan outside will start. The controller on unit flashes an error for low pressure switch open (error #32). Gas pressure is normal! My technician says that he will have to order a new compressor because of some checks he has done. What I need to know will the controller show low gas pressure if the unit has never started even though the low pressure switch is closed as it should be with proper levels (checked the switch an


No unless there is a loose connection of the wires or terminals between switch and controller ... Air Conditioners

I have a Nanomax Amcor CF14000E and for some reason, when i have it running, after i set the temperature to say 73deg F the digital screen then goes back up to 90 deg F, This is not the room temperature (which is 80 deg F), but for some reason the temp setting keeps going up to there. Over and over I reset it and then set the guage to 73 and sure enough it then goes up to 90 deg C, then while at 90 with no compressor on it beeps every 10 secs. It is like the temp setting button is compr


It sounds like your sensor failed. You'll need to disassemable the unit to find and replace the sensor. Chances are it's just a 100 OHM sensor and it cost about 10 bucks to replace. Do you have the manual and does it have a schamatic? ... Amcor PLM-14000E Portable Air Conditioner