Having problems with your Air Conditioners ?

Fedders Window AC Unit

\015 When I plug in my Fedders Thru Wall/Window unit, it runs through all the functions with all the little green lights lighting up, turns on for a second, and then shuts off. \015\012Then, after remaining plugged in for approximately 30 seconds or less, it stops working altogether. \015\012\015\012Alternately, sometimes it cycles through the temperatures and starts at around 72, then walks up all the way to like 88, while still doing that whole shut off thing in between each temperature. \015\012Then it shuts off altogether. \015\012\015\012Possible power shortage or what? Any ideas?\015

Answers :

I would try to start the unit with only the fan running at first. If it stays running then cycle on the compressor and see how it does. If the unit does not operate when compressor is turne on then we have to dig deeper into that.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a fedders window unit ac model a6y12f2bj. Last night it was running perfectly when all of a sudden uit shut off and the LED readout, which usually just says the 2 digit tep now says


... Air Conditioners

Error code E3 on fedders window unit. unit will only turn on for a few seconds, fan and compressor both when you hold the power button down for a few seconds but then turns off almost immediately.


Looks like micro controller problem. Contact service center for assistance. ... Fedders AED24E7F Wall/Window Air Conditioner

I have a problem with my 8000 BTU Fedders AC window unit. Error code EE comes preventing the unit from running. What part does this indicate to bad?


... Fedders D Chassis A6D24E7A Air Conditioner

I have a fedders window a/c unit, it has been stored for several years. I plug it in the power to the timer comes on but the unit will not turn on?


... Fedders X Chassis A6X05F2B Air Conditioner

We have a fedders AED24E7CG window air/heat unit. The left side is blowing cold air--when on heat setting. It looks like there is a coil in it cuz the right side is glowing orange & pushing heat but the left side isn't glowing & is pushing cold air. Unit was here when we bought the house so I don't have a book & am having trouble finding any info. online.


... Fedders AED24E7F Wall/Window Air Conditioner

Fedders Window unit


The capacitor's for running, too. The resistor across the capacitor is supposed to be warm but not hotter than boiling. Just disconnect the capacitor and check for a short if you suspect it; but it would be warm someplace. The timer unit is ... Fedders D Chassis A6D24E7A Air Conditioner

Fedders Window AC Unit


I would try to start the unit with only the fan running at first. If it stays running then cycle on the compressor and see how it does. If the unit does not operate when compressor is turne on then we have to dig deeper into that. ... Fedders J Chassis A6J12E7A Air Conditioner

Fedders window unit won't blow cool air


Hi There,\015\012It needs to be re-charged with freon. ... Fedders Q Chassis AEQ08F2E Air Conditioner

I have a Fedders window unit air conditioner and when I plug it in a get an EE on the display. can you tell me what this means?


... Air Conditioners

What is the btu of a fedders window ac unit model number A1Q05F2D


5 thousand btu ... Air Conditioners

Fedders window AC unit, model: A2Q10F2BG-AC dimentions


... Air Conditioners

I have a fedders 25000 btu window unit, it will come on, get cool for a few seconds and then start to roar .. and then the air turns warm. What is the problem?


Possible compressor problem. ... Fedders AED24E7F Wall/Window Air Conditioner

Fedders window model A6Y12F2B "New Unit",,only 10 days in use! Just stopped working No Power To Master Panel Air Conditioner Not Working Fuse Panel/Breaker ok,Outlet ok,,power to plug ok(lights up) Reset button on plug functions normally Master Panel is dead, will not light up, non functioning controls


Take it back to the store. Manufacture defect if it died after only 10 days. Attempting repair or disassembly will probably void warranty. ... Fedders Air Conditioners

I have a Fedders window AC unit, model: A2Q10F2BG-AC. It works in the Cool position. When switching to the HI FAN position it shakes and then stops. Changed the capacitor because it was not doing anything. I am not sure what to do next.


... Air Conditioners

Water leak i have a fedders window unit that is leaking water into my house


Make sure the unit is tipped to the rear slightly. Do not drill holes in the base! ... Maytag NMPEB08F2A Air Conditioner

I have a fedders a6q10f2d window unit about one year old. One day while it was raining the fan quit blowing. Is there something I should check before replacing the motor?


... Fedders A6Q10F2D Thru-Wall/Window Air Conditioner

I have a fedders window ac unit where the compressor will turn on sometimes and others will not. When I shut it down and restart later it usually will run for a while. What is wrong?


You could have dirty coils on the outside of the unit. You can clean them with compressed air, water hose or get a can of a/c coil cleaner. If you get coil cleaner you will still need the hose. ... Fedders A6X05F2D Air Conditioner

My fedders ac window unit turns on and gets cold for ten minutes then the compressor turns off and dont turn on until i turn it off for about 20 minutes


Make sure you air filter is clean and check you evaporator coil also. If there isn't enough airflow across the coil the head pressure of the compressor will build up causing the compressor motor to heat up and cut off or trip on overpressure. You can ... Fedders D Chassis A6D24E7A Air Conditioner

My Fedders model AEJ12E7AG ices up. This is a combo AC/Heating window unit. The heat works fine. Has it leaked out the freon or is there a circulation proble? Is it repairable?


The most common cause of icing in these category of units is a dirty air filter or partiallly dirty condensing or evaporator coil. If the unit is over 5 years old or has been operating in a dusty environment or hasn't had much service, then also che ... Air Conditioners

I have a Fedders Model A7Y15F2B-A,14500 BTU window A/C unit.. I am not sure what is the parts call but I found out part # CBB65A-1 and I have been search it from Ebay or Web didn't find a same one with 45+6uF +/- 5% , 50/60Hz..my question is can i using other different one to replace it? and some cable are burned. can I make my own cable from HomeDepot?? plz help


That is a dual capacitor - 2 capacitors in a single casing. Replace it with 2 separate capacitors , which you can buy here\012\012\012http://www.talonix.com/shop/category.aspx?catid=1Just make sure to match the voltage rating and the pola ... Fedders Y Chassis A7Y15F2A Air Conditioner

Missing exhaust kit. Need window adapter, hose and connector/adapter for back of unit hot air exhaust port. NMPEB08F2A Rev B made by Maytag / Fedders


Try duct tape , pvc pipping and cardboard, Tape the pipe to the back of the ac and them use a cardboard piece with a whole cut out for the pvc pipe in the window ,coat the cardboard with several layers of tape inside and out..It should work for awhil ... Maytag NMPEB08F2A Air Conditioner

We have a Fedders window unit and we do not have an owners manual. When we plug it in it beaps and then blows air for 2sec and then it goes off with the signal E3 showing in the digital box. We need to know what that means so we can get our house cooled down.


Without the model number, I can't point you to the exact manual for your particular unit. However, here's a link to a web site that has about 38 manuals for various Fedders models. You can download a manual and/or users guide for free and look at the ... Fedders Appliance Air Conditioner Wall

We recently replaced an old window unit with a westpointe a/c mwk-08 unit. The old unit was dripping water in the house but the new unit doesn't seem to be dripping any water? Could this possible be a drip "less" unit or is it installed incorrectly? I've heard the horror stories about mold building up in window units & causing MAJOR health issues.


If the old unit was dripping condensate into the house, it was installed incorrectly. The replacement unit may have been installed correctly so the condensate drains outside. ... Air Conditioners

I have a thru-wall unit that is draining out of the back and cooling just fine. My problem is the hole in which the ac goes thru. There seems to be some condensation on the bottom of the unit that drips down onto the board below(would be the window sill if I had taken it thru the window). I have thought about taking the unit out and placing a piece of insulating foam in the bottom of the unit or closing the 1/2 inch gap between the bottom of the unit and the board with insulation or expand-a-


You are correct the gap needs to be closed, i would suggest the double taped insulation they use on pick up truck when you put a topper on, as if you ever need to remove unit it would be easier then the expansion foam. Hope this helps Tim ... LG Electronic Window Air Conditioner

Have kenmore plasmaire window airconditoner. I think the fan just went out. I only get a humming noise. I have had this unit for about 6 yrs. I admit, that the filter was filthy when I opened it up. the unit stays in window all year, but is covered on the outside during the winter. what do I do? is it worth having repairman out or just getting a new unit. unit is at least 10,000btu.


My Kenmore Air Condition Window Unit, my daughter turned it on & then turned off & then on again real fast, then it wouldn't do anything. Now nothing lights up, I checked for power with circuit tester & it has power. However, the lights d ... Kenmore 75085 Air Conditioner