Furnace will not light, but there is gas to the house

\015 Yesterday i ac shut down, first was blowing hot air, then furnace shut doen and cannot light it, but we do have electricity and gas to the house.\015

Answers :

This problem will need to broken down in several steps. First, reset all the breakers that operate the furnace and ac. Turn the thermostat to on and the ac to off and see if the furnace blower starts. Get back with me.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I am looking to buy a house in forclosure. It has a Tappan gas furnace about 9 years old and there is no manual. Can you advise as to whether the following problem is serious and estimate what the cost of repair will be? Exhaust blower is always on; red light on circuit panel is constant. Then gas flame is ignited and burns for a couple of seconds; yellow light on circuit panel comes on. When blower motor begins, gas flame goes out, yellow light goes out, and red light repeats sequence of 2


HelloSounds like the flame sensor is bad.Or possible photo eye.Worst case would be a new circut board.Anywhere from $100.00 to $300.00 depending.Legally a home you purchase has to have a heater that works and a hot water ... Air Conditioners

I bought a forclosesure this summer and not all that familar with the furnace in the guest house. I'm use to having a furnace with a pilot light(yes, it was 34 years old)now I,m trying to get a goodman furnace going. I know it was sitting around for atleast 2 years. The home inspector said everything works.The model number is gmnt040-03. The gas is turn on the outside line. When I start it she begins to hum and then the ignition light goes on. then a blowing noise but then I get no flames-after


Hi,A few things to check...Is the gas line valve on at the unit....follow the gas line back a bit sometimes the gas valve can be out of view.Also check the gas valve in the furnace... it may also be in the "off" position.... ... Air Conditioners

Honeywell thermostat; Lennox elite series furnace thermostat reaches and exceeds temperature setting but frunace continues to run, remove trermostat from wall and furnace continues to run. Not just fan- entire system, I have removed both panels from the furnaced itself and as soon as power is supplied the furnace immediately lights (gas) and begins to heat house. Current inside temperature is 77; set to heat to 70.


When the furnace exceeds the temperature set by the thermostat, this could be indicative of several issues. The thermostat mounted crooked. When a thermostat isn't level on the wall, it can affect the automatic on/off function. To fix this pro ... Air Conditioners

Furnace will not light, but there is gas to the house


This problem will need to broken down in several steps. First, reset all the breakers that operate the furnace and ac. Turn the thermostat to on and the ac to off and see if the furnace blower starts. Get back with me. ... Haier HWF05XC5 Air Conditioner

Thremostat reaches and exceeds temperature setting but frunace continues to run, remove trermostat from wall and furnace continues to run. Not just fan- entire system, I have removed both panels from the furnaced itself and as soon as power is supplied the furnace immediately lights (gas) and begins to heat house. Current inside temperature is 77; set to heat to 70.


... Air Conditioners

Gas heat does not always come on when it is switched on, when it does it works fine when it does not, the house is filled with a bad smell, I'm assuming unused gas. we have had the burners scrubbed with a wire brush before and no problems for 2 years. Can the burners just be replaced? Pilot light works fine. The furnace tries to come on, i can hear it clicking to ignite. Thanks Ronnie from Atlanta


You need to check gas vent ASAP. You should not be getting any odors from your furnace. Have a technician check your furnace. Could have hole in Heat exchanger. If so you and anyone else there are in danger. Please do not operate till it has been che ... Air Conditioners

My mom has a Holly Duo trol gas furnace that clicks on and off all day and night, barely heating the house and I'm having to relight the pilot light every other day. Is there some maintenance that I can do myself before calling in the experts. I am fairly handy and mostly desperate.


Hello\015\012First check the draft on the flue,the big pipe that goes to the chimmney.\015\012\015\012Make sure the flap is free to move and clean any dirt away from it.\015\012Turn heater off to do this.\015\012\0 ... Air Conditioners

Condensate pump Installed pump 2 years ago. Today, while a gas fitter was replacing some gas piping, the furnace was off for about 2 hours. After a leak test, the gas was turned back on. Furnace works well, but condensate pump has all lights on and the motor is hot. Is not pumping. What does the red alarm light mean, exactly? How can I reset it?


... Horticulture Source Air Conditioners

I have an 8 year od York furnace model P1XUC20N09501C 90%. The problem is the ignitor comes on, the left burner lights, but the other burners won't light. I can light the other burners manually with a lighter and the furnace works fine. My furnace repair guy was at my house and told me to remove all the burners and clean the ends of them. I took the first one out next to the one that lights and cleaned it. (What a challenge and time consuming) It still won't light. Obviously after the rema


... Air Conditioners

I have an amana dual fuel heat pump with LP gas furnace. the furnace will not light. the ignitor heats up, acts like it's not getting LP to the burner and i don't get 24 volts to the pressure switch just above the gas valve, or to the gas valve itself. i cut the power to the unit, removed pintle to the gas valve to ck for gas to the valve and it's o.k.,. what do i need to check next, i don't know how to get codes out of self diagnostic system and don't know if these codes would effect the furnac


... Amana Air Conditioners

Jan 10, 2010 - i should probably give some more info.. it's a ruud silhouette II gas furnace that had been giving me problems with the furnace starting up and shutting down immediately.. i solved this by cleaning the flame sensor rod, although i didn't replace it.. now it starts with a very weak flame and will only light one burner sometimes.. when it does light with all 4 burners they seem to kind shrink in size every few seconds like the gas isn't steady.. this is a new issue, is it possibly


It is possibly related to the flame sensor giving a week signal to the gas valve. You really nee to have the gas pressure checked and the flame sensor checked if you have a multimeter that checks miliamps you will know if it is the flame sensor. You ... Air Conditioners

We are planning to add several natural gas appliances behind our house. One being a 10KV Generator,the other a gas fire pit.Also Possible a small gas furnace in a work shop. I already ran a one inch black gas pipe through the back wall of my house about five feet above ground. I stopped after adding a 90 degree elbow pointing down. I would like to step it down to 3/4 in. pipe to the generator, fire pit, ect. How would you confiqure the pipe so I could make three connections. Thanks Al.


Hello It is IMPORTANT to keep the entire run 1".When you get close to the appliance use a 1"X1/2"X1"bull tee.Right now you need 2.Use a 1"plug at the end for future furnace hook up.You need to maintain 1" for pressure during demand reasons.You can us ... Air Conditioners

I have a dayton furnace with a honeywell vr8440p-2088 gas control. The ignition works fine but the problem is I am getting no gas it seems to light the pilot. I checked the orifices at the end of the pilot gas tube and could see light thru it so it was not blocked. Could this mean I would need to replace the gas valve completely? Any help appreciated [email protected]


Actually, after exhaustive troubleshooting and testing, all testing told me the gas valve was defective. I then replaced it. Problem was still there. I then took a shot for what it was worth and went down to purchase a new thermocouple to sense the p ... Honeywell Air Conditioners

Hi , I have a Electronic pilot lighting system on my RUUD package unit. The pilot light flame keeps blowing out or is not working properly. I removed the panel to look and see what was wrong. I could not see any faults. The sparker worked just fine, the gas line tubing was fine no blockages( took it off to inspect it) every thing looked good. Worked fine for the last couple of weeks and now it will not ignite the pilot light to light the rest of the propane gas to heat the house. I tested the fl


Sounds like you have checked most things. A pilot will go out if it is dirty, if the gas valve is not holding or if the senser is dirty or bad. Remove the pilot and clean out the small orifice inside. Check all electrical connections, clean the senso ... Ruud UBHC Air Conditioner

Gas adjustment. I have 2 screws inside my furnace on the gas control box. both screw out and leave ajustmentscrews inside. one of them is for the pilot light and the other one i have no clue. I think it is for gas pressure but how do I adjust it??? My furnace is a AMANA AIR COMMAND GH SERIES HIGHBOY. THANKS!!!


To adjust gas presure you need a wg presure gauge ... Air Conditioners

I have a Rheem RGDA-100A-AR gas furnace, and I believe the pilot light is out and needs to be re-lit, but I'm not sure where it is. Any ideas where it might be or what it might look like? And do I have to light it with a match? The instructions on the inside of the cover just say to "light it" while depressing the manual gas switch in the Pilot position.


Hello and thanks for inquiring. Take the front covers off the inside unit. This is where you will find the Gas Valve. Next locate the pilot assembly. This can be done by following the thermocouple from the gas valve to the end where you will see a li ... Air Conditioners

Intertherm gas furnace 80 % mod# MMHA-070ABHR-05 will not open gas valve and light <changed gas valve <control board<ignitor all three limits and still not working I have been in the hvac buisness for 10 years but cant solve this one ,the board is flashing a 3 code < i have called a fellow tech who had the same problem on the exact same model last year and he spent 10 hrs trying to repair this unit but was unsuccesfull also<i can make this furnace burn by wiring 24 volts direct t


... Intertherm Air Conditioners

We have a Intertherm MAC 1378 gas furnace in out mobile home and it has shut off on us. There is still gas coming in, we checked the meter outside to be sure. But when we try to reignite the pilot light it wont ingnite. We can't smell any gas when we try. We've followed the instructions on the furnace on how to reignite it and it still wont work. It's well below frezing with a **** load of snow we have 2 kids, one of which is a newborn and its getting really cold. So anything you can tell us wil


Check to make sure the roof vent is not covered over with snow.\015\012Very deep snow can block the intake to the furnace. You may need a ladder and a broom (or shovel) to clear the snow.\015\012Hope this helps.\015\012Matt ... Air Conditioners

Hello, I have a Heater/Furnace problem. I have a Carrier 58RAV095-16 Natural Gas Furnace. My furnace keeps restarting it's heating process. Upon turning the heater on, a small fan will engage and run for about 60 seconds, then the fan turns off and the gas engages and the igniter clicks and you hear the gas combust and the flames spew out onto the heating rods(?) and after a minute or so, the big fan will turn on and begin circulating air throughout the house. Sounds all good so far? Well


... Air Conditioners

Hi, i am on a pre pay gas meter and when the gas runs out it shuts everything off, which means i have to relight the pilot on my boiler. the ignition won't spark and it takes me ages to get the pilot to light, when it does it stays on. was wondering if it woukd be safe to light pilot with a gas lighter? i know the obvious solution is to have the ignition fixed but can't afford this at the moment, but i don't want to end up blowing my house to bits either, hope you can help.


I use the extended gas lighters for grills all the time. Its safer and keeps me from getting burned while lighting the pilot. ... Air Conditioners

Intertherm mac 1199 furnace, pilot lights OK but when main burner lights, gas is shut off to both pilot and main burner immediately


... Air Conditioners

The yellow light on our Gibson furnace is flashing. The furnace lights but does not get up to the temperature and goes off only to kick back on a little later and do the same thing. I know this is a low flame warning. We recently had a piece on our gas meter replaced. Could this be the problem?


... Gibson Air Conditioners

I have an coleman evcon furnace that was working fine until a switched propane companies, now my furnace won;t light the surface igniter works but no flame but my gas stove works fine,so i no i'm getting gas into the home


Check the gas valve and circuit board for poor connections. Have gas company check gas pressure under load. ... Coleman Air Conditioners

Im trying to figure out how to light my neighbors 7900 series gas furnace. Followed instructions pressing pilet light etc. Just cant figure where to ignite inside furnace door.


Hi, Just follow the pilot light tube back, the aluminum tube, back under to where it stops at the pilot burner. You may need to open the door to reach back there or you may have that piece of metal that you put the match in to reach back far enough t ... Coleman Air Conditioners

I have a Goodman GMP100-4 furnace. Recently, I replaced the circuit board and the thermostat, and the system worked well for about three weeks afterward. On Saturday, the furnace ceased to come on, no flame. Electronic ignition glows as it should when the call is made, but gas will not light. Gas is on for sure-I disconnected and checked the line. Can the regulator be repaired, or is it a "replacement only" part. Flame sensor does not exhibit corrosion, but I haven't disconnected it to l


I would recheck my connections to the thermostatIf they are connected and in good shape the I would suggest trying one other thing before purchasing a regulator (replacement only part). Try taking the power cord from the wall and where it connects t ... Air Conditioners