Air Conditioning I have a ruud system with the air conditioner outside and the air handler upstairs in the attic. My systems appears to be running, and I can feel cold air at the vents, but I can barely feel it. Like there is no flow. The fan outside is running and the unit in the attic is running. I have no clue what the problem is. The large coil coming from the heat pump outside is cold and has condensation on it. It also seems to have a little ice. It has been extremely hot here in Ge


Answers :

Open the access panel on the air handler in the attic and take a look at the evaporator coil. If you have no airflow, and you just changed the air filter, then you probably have a buildup of airborne crud on the coil that's blocking airflow. \015\012\015\012If you do have a layer of buildup blocking airflow through the coil in the air handler, just take a $5 fin comb and scrape all the crud off the coil fins. This can make a dramatic difference. \015\012\015\012Hope this helps! ;)

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Air Conditioning I have a ruud system with the air conditioner outside and the air handler upstairs in the attic. My systems appears to be running, and I can feel cold air at the vents, but I can barely feel it. Like there is no flow. The fan outside is running and the unit in the attic is running. I have no clue what the problem is. The large coil coming from the heat pump outside is cold and has condensation on it. It also seems to have a little ice. It has been extremely hot here in Ge


Open the access panel on the air handler in the attic and take a look at the evaporator coil. If you have no airflow, and you just changed the air filter, then you probably have a buildup of airborne crud on the coil that's blocking airflow. \015\01 ... Ruud UAKA030 Air Conditioner

No heat We had the mini split installed and have not needed the air conditioner yet. But now that I want the heat on, I can't get any. The indoor unit lights up and the fan comes on but only blows cold air. I have checked everything I dare to, and noticed that the outside unit doesn't seem to be running. I am reluctant to call the guy who installed it because he was not a happy guy to do it in the first place. But he was the builders choice. Any suggestions of things to check into myself?


From my experience, when a new heat pump unit doesn't switch over from one to another, its most often the thermostat isn't wired correctly. The reversing valve needs energized or the common is ... Sanyo 09KHS51 Ductless Mini Split Air Conditioner

I have a Inter therm Model# FEHB015HA central heat & air unit that I had problems with in the summer as the out side unit would not come on but the blower would kick on but nothing on the outside unit(No cold air).Ok I fixed that as it was the the transformer that switched it down to 24 volt to go to the outside.Now I have noticed that when the heat is on it will not kick the outside unit on?It has been very cold here in Georgia but right now as I type it is 50 degree's and the outside unit is s


Hi, if this is not a gas fired split system, it is a heat-pump with aux heat strips. The outdoor unit must be on to warm you're home by way of the reversing valve. The strips in the indoor unit are for emergency and auxiliary heat only. ... Air Conditioners

Wall A/C only SPORADICALLY blowing cold air. Turn it off and back on, you can feel it's cold, but only if you're 5 inches from it. After a couple of minutes, fan is only blowing warm air again. Vacuumed front of A/C, still doing the same thing. Filter is clean. It is over 100 degrees outside with very low humidity the last few days.(Los Angeles) ; since it's a wall a/c, of course 1/2 of it is outside in the heat. As I noted, if you put your hand right up against the front, you can feel cool air


If it blows be not with force like it used to it can be fan motor capacitor not boosting fan speed. but if speed is not the issuse. remove and clean both coils water hose ... Air Conditioners

Ac problems i have a goodman ac system. i can not get it to cool one side of the house. i have it turned down to 72 and the thermostat says it is 80 in the room. i can hear the return vent sucking air and the ac unit outside is running but no cold air is coming inside. the unit outside has cold air coming out the top when the fan inside it is turning


Hello from KOOLBREEZES, this is a simle problem and easy to fix. You have 2-lines going to / from your outside unit. a SMALL COPPER -line and a LARGE COPPER line with insulations. The fat line is suppose to have moisture on it wheres it,s not insulat ... Air Conditioners

I'm having a problem with my heating and air system, my heat only works on emergency heat ( and run 24/7) if i turn it to regular heat it only blows cold air. i dont think my outside unit fan is turning( i could be wrong about this one) how can i fix this problem so i dont have to run my emergency heat all the time


If your Heatpump's fan isn't running but your compressor is, your fan motor is out. If nothings happening at all ensure your getting power to heatpump (ex: breaker tripped, fuses blown on outside power switch, or fuses blown in breaker box?) ... Air Conditioners

On my heat pump, my thermostat is on heat the fan is running but no heat is coming out.just cold air, I even tried it on emergency heat also and its just cold air...


I am assuming you have electric heat as a back-up.\015\012If you do make sure thre breaker switch to the electric heat is turned on for starters. ... Air Conditioners

I recently had a new outdoor unit installed on my central heat and air conditioning sytem. I have had the installer out 3 times and the system still does not operate correctly. Sometimes when it cycles (every other time or every third time) the unit does not blow cold air. Sometimes the unit comes on not blowing cold air and the compressor fan is running but not the compressor. Sometimes after 15 minutes of this the compressor will come on. What is the problem.


It sounds like the compressor needs starting components installed on it. All a/c units have a run capacitor for the compressor and another one for the condenser fan motor. These motors use these capacitors all the time when the motor is running. H ... Air Conditioners

Bryant air conditioner - outside unit will not run - before it quit running, air temperature in house rose from 65 degrees to 75 degrees. Inside fan continued to blow - air smelled like a car air conditioner that ran out of Freon. Bought Freon - need to know where to add it. The heat pump model # BF-163S bi directional but also coming from unit is another line that runs same direction with same type of valves. Air conditioner model # 697CN030 - B


... Air Conditioners

I have an AR32-1 with an emergency heat switch on the thermostat. The heat pump runs and runs and runs and blows cold air when it's freezing outside. If I turn on the 'emergency heat', nothing happens. We do have three 220V breakers in the panel box. One is labeled 'heat pump', the other two are labeled 'furnace'. What could be wrong that the 'emergency heat' does not work?


... Goodman Air Conditioners

My coleman Mach Rv air conditioner with built in heat strip keeps tripping it's internal circuit breaker when running for any length of time. Just replaced heat strip with new one experienced same issue. I ended up with the fan continuing to run but only cold air comes out of the vents! When I removed the old unit and reset the circuit breaker it too worked again. Have no idea what is causing this to happen. The airconditing part of unit works just fine??? HELP! Ron


There should be an overload protection device in series with the low voltage wiring(t-stat wiring) Is it resting on the heat strip or too close to it? It is a saftey device to shut off the heat strips if the fan quits or a fire in the heat strip sec ... Coleman Mach III Air Conditioner

Turned on AC was running fine. 30 minutes later began to hear a strange noise. Opened AC/Furnance closet & heard a sound best described as air letting out of a tire. It seemed to be coming from copper pipe. Minute later sound stopped & air was suddenly hot. As if AC was turned on fan not cold. Went outside & neither fan nor motor was running. Turned fan manually. Ran for about a minute then stopped. Outside unit was making what could best be described as a buzzing sound.


Hi!!\015\012\015\012This means that the condenser fan motor (outside unit) failed, this caused to build hi pressure and either activated a safety valve to release the extra pressure or blew a line and R22 Refrigerant escaped from system. ... Goodman CKL42AR42 Air Conditioner

After a cooling cycle, when the thermostat call for more cooling, it take up to 5 minutes after the air handler starts for the compressor motor to restart. The top fan operates on the outside unit, but since the house is not circulating cold air, only the room tep air the house heats up about 3 degrees before the compressor comes back on and cool air begins to come from the ducts. Yes. I know there is a safety feature to protect the compressor, but can the cycle be shortened?


No, this cycle cannot be shortened due to the simple fact that this feature is in place to protect your system. Even if it could be, I wouldn't recommend it.Mat ... Coleman Air Conditioners

If the weather outside is cold and you are running the heatpump/aircondition. Is the fan motor on the outside suppose to stop running. I notice the there is heat coming from the unit after it as been running awhile but the fan is not running


Yes the fan will shut down during the defrost cycle. But the fan only shuts down during this cycle....other than defrost the outdoor fan motor should be running during a call for heat. ... Amana Air Conditioners

I have a Toshiba Heat pump. 220-240V 50HZ 40 watts. I have lost the manual and do not know how to get it to give me hot air. I put the temp at 22deg but seem to just get cold air blowing in on me all the time. Surely when it is 5deg outside I should be able to get hot air coming form the stupid machine. However said heat pumps were good obviously hasn't got one of these!!!


It's in the wrong mode ... Air Conditioners

I live in Florida, my a/c system, I believe it is a Rheem, has been heating the house fine all of this winter no problem. With this last recent cold spell, I turned on the heat and all that is blowing from the vents is air that feels a few degrees warmer than the air in the house, it does very slowly start to raise the temperature in the house but is taking a very long time. I have stopped using the heat for fear of damaging the inside and outside units, need help


I would call someone that knows how to check the pressure in the outside unit. I would run emegency heat if it gets to cold. Switch the thermostat from heat to emergency. If the outside unit was running when the temperature was to cold and not going ... Ruud Central System Air Conditioner

My heat unit will not blow hot air unless we go outside and hit a button on the back bottom of the unit. Once we do that it will blow hot air for that cycle. when it is time for it to come on it is cold air again and the unit outside is not working.


If it does not have a furnace or heating elements for heating, then it is a heat pump, which is rare for a central AC system, but makes sense of the fact that it blows warm air when you reset the pressure switch, which may indicates freon pressure ch ... Ruud Central System Air Conditioner

The air conditioning unit outside is running but there is no cold air coming into the house. I hear the inside unit turning off and on but no cold air. I also smell a burning odor. I have turned off the unit via the thermostat.


If unit is going on then off within a few minutes needs service can be needing freon,outside dirty causing overheating,power supply if 220 not getting full power ,to compressor going bad ... Goodman CLQ36AR49 Air Conditioner

I have a goodman cpk j42 -1b ac unit on the outside and a central heat and air unit inside. the ac unit come on and runs fine but when it hit the temp the thermastat clicks and the fan outside goes of but the one inside stays running and will not turn off unless i hit the breaker. is it he fan relay at the outside ac unit?


Hello BWOOD Check the thermostat FAN button is in AUTO position not ON position.That might be it .The relay is in the blower unit but they RARELY become frozen/welded stuck on. ... Air Conditioners

Airflow We have a new ducted PEH-MYB reverse cycleairconditioner. We set the temperature at 20 degress for heating. Once it reaches it it then blows out cold air. We have had someone come 4 times already to fix various problems. It is not nice to sit near a duct and feel cold air. I thought the air flow was meant to stop, then start uo again when the temperature dropped just like our gas heaters? Am I wrong?


Go to www.mrslim.com. Look under the tab for library. Ib there you will find the troubleshooting guide for this model. Make sure the remote is set for cool and make sure the fan setting is not on automatic. ... Mitsubishi Mr. Slim MXZ30TN Air Conditioner

Did not use air conditioner for 2 years .Model #sck 7500 dr/kc-22y.started it and let it run for 4 hours . All functions are working including fan ,no cold air coming in,outside temperature is 70 degrees F,setting on air conditioner 65 degrees F.Does the temperature outside have to be warmer ?


... Sunbeam Air Conditioners

I have a Trane XE 1100 outdoor unit. I had to refill the freon gas 3-4 times in 3 years. The technician mentioned that I need to replace the outdoor unit. last night, the outside unit was running and the unit in the attic was running and the copper pipe was cold and wet, HOWEVER no air was coming out of the vents all over the house. Do you have an idea WHAT IS THE PROBLEM ? My question: Do you have an idea How much it costs to replace the outside unit ?


... Air Conditioners

In heat mode thermostat set for 68 and room temp on thermostat reads 68, but unit contines to run. The air coming through vents is cool air. Unit never shuts off, runs constantly. This is the case when outside temp is 30 degrees or 45 degrees.


Could be under sized unit or fan relay on unit. ... Goodman PHKJ024-1 Air Conditioner

AC is running outside and the big pipe is cold and the little pipe is warm. fan is running inside the unit (Trane) and test light is blinking normal. thermostat is set at 75 but no cold air is coming out of the vents anywhere in the house. any thoughts?


The A coil is froze up the low pressure side is too low, add freon ... Ruud Central System Air Conditioner

Have an amana central air duelfuel heat system.when aux heat[gas] heats the house and shuts off the fans still blow for 3 to 5 minutes with the last couple of minutes being cold air which cools the air it just heated. also heatpump will start heating when it comes on then after 3 or 4 minutes it starts blowing cold air like when the air conditioner is running.i have had problems from day of install 4 mounths ago with problems that keep coming up. please i need help fast i do not think comp


Change your heating delay to shut off sooner, you can find this in the installation manual. Also the Thermostat may have delay after heat as well. It is true there could be many variables, but it also sounds like the Heatpump is not charged properl ... Amana Air Conditioners