Having problems with your Air Conditioners ?

Emerson Quiet Kool 6GC53 Air Conditioner

\015 Turned air conditioner on.\015\012\015\012Fan started normally.\015\012\015\012But thermostat refused to kick in and start the compressor.\015\012\015\012Steps taken:\015\0121. Tried various fan speeds.\015\0122. Tried various thermostat settings.\015\0123. Tried various combinations of 1. and 2.\015\012\015\012Result: Fan still running, but no cooling.\015\012\015\012At first, changing thermostat settings from MAX to MIN, there wasn't even a click, nothing.\015\012\015\012After running it for an hour or so, it now clicks (at the compressor on/off point), but still no compressor start, no cooling.\015

Answers :

Chesapeake, given your symptoms you'll be looking at installing a new Selector Switch. But, before you go there... \015\012\015\012UNPLUG THE UNIT OR SHUT OFF THE BREAKER!!!\015\012\015\012Your selector switch does two things at a time, It energizes the fan motor (which it IS doing) and energizes the compressor at the same time. The voltage to your compressor goes from the wall into the selector, out of the selector, through the temp control then to the compressor. When the temp control is satisfied, it interrupts power to the compressor. The click you hear is the temp control being NOT satisfied and trying to send power to the comp. But if there is "no power" to send (i.e., the selector switch has failed)the compressor won't know to engage.\015\012\015\012Remove the front panel and filter. Remove the control box housing. Remove the knobs from the controls. You will now see the selector switch. Remove the 2 screws that fasten it (don't remove the wire yet!) and install the new switch. Then, one wire at a time, remove the wires from the old switch and install them on the new one.\015\012\015\012***If you have an OHM meter, check the temp control before ordering a selector because this may be the problem and NOT the selector! To do this... remove the 2 wires from the temp control, set the control to "coldest". Then with your meter, test OHM's between the terminals. If you see "zero" OHM's, it's good. If you see no change in your meter, it's bad and THIS is the source of your problem.\015\012\015\012If you don't have a meter... you can test using this procedure... cut a 6" length of wire and strip the ends to about 3/8", twist the copper ends tightly. Remove both wires from the temp control, then insert one end of your jumper wire into one terminal and the other end into the other terminal. Make sure the "jumpered" wires are away from anything metal!!! And plug the unit back in. Now turn the unit on. If the unit fires up? It's the temp control, If not? it's the selector switch. Here's a link for parts...http://www.repairclinic.com/0080.asp

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Need side curtain for emerson quiet cool a/c - Emerson Quiet Kool 6GC53 Air Conditioner


... Emerson Quiet Kool 6GC53 Air Conditioner

Emerson quiet kool 12GD44 air conditioner - Emerson Quiet Kool 12HT13 Air Conditioner


... Emerson Quiet Kool 12HT13 Air Conditioner

Emerson quiet kool 12GD44 air conditioner - Emerson Quiet Kool 12HT13 Air Conditioner


... Emerson Quiet Kool 12HT13 Air Conditioner

Emerson Quiet Kool 6GC53 Air Conditioner


Chesapeake, given your symptoms you'll be looking at installing a new Selector Switch. But, before you go there... \015\012\015\012UNPLUG THE UNIT OR SHUT OFF THE BREAKER!!!\015\012\015\012Your selector switch does two things at a time, It energizes ... Emerson Quiet Kool 6GC53 Air Conditioner

Compressor emerson quiet kool 12jw42k air.. - Emerson Quiet Kool 12JW42K Air Conditioner


... Emerson Quiet Kool 12JW42K Air Conditioner

Compressor will not come on. - Emerson Quiet Kool 6GC53 Air Conditioner


... Emerson Quiet Kool 6GC53 Air Conditioner

Emerson Quiet Kool 6GC53 Air Conditioner finding parts


... Emerson Quiet Kool 6GC53 Air Conditioner

How much do i tilt the emerson quiet kool - Emerson Quiet Kool 10GV13 Air Conditioner


... Emerson Quiet Kool 10GV13 Air Conditioner

Replacement screen for a emerson quiet kool - Emerson Quiet Kool 10MW42K Air Conditioner


... Emerson Quiet Kool 10MW42K Air Conditioner

Emerson quiet kool drain - Emerson Quiet Kool 10NW16K Air Conditioner


... Emerson Quiet Kool 10NW16K Air Conditioner

Emerson quiet kool not heating - Emerson Quiet Kool 10MW12K Air Conditioner


... Emerson Quiet Kool 10MW12K Air Conditioner

Emerson quiet kool air conditioner


... Air Conditioners

Removing front panel on Emerson Quiet Kool Window Air Conditioner


... Emerson Quiet Kool 6GC53 Air Conditioner

EMERSON AIR CONDITIONER QUIET KOOL


... Air Conditioners

1990's Emerson Quiet Kool window air conditioner


Hi, It opens a flap that allows fresh outside air to come in. The opening it screen covered on most units so no insects get in. To get the most cooling it is best to leave it closed. If you want fresher air, open it. Please rate my suggestion if it h ... Emerson Quiet Kool 10GV13 Air Conditioner

I need a new filter - Emerson Quiet Kool 12GJ14 Air Conditioner


Hardware store item. ... Emerson Quiet Kool 12GJ14 Air Conditioner

I have a 1985 Emerson Quiet Kool model 19LD4E window air conditioner, and I need a replacement filter, mine is the original factory filter and has crumbled from age.


You may have to buy a cut to size filter from a hardware store ... Emerson Quiet Kool 10GV13 Air Conditioner

How to clean filter in 24JD44 - Emerson Quiet Kool 12HT13 Air Conditioner


... Emerson Quiet Kool 12HT13 Air Conditioner

Front panel replacement - Emerson Quiet Kool 10NW16K Air Conditioner


... Emerson Quiet Kool 10NW16K Air Conditioner

Emerson quiet kool 12gj14 air conditioner


... Emerson Quiet Kool 12GJ14 Air Conditioner

Shows a code e1 - Emerson Quiet Kool 10NW16K Air Conditioner


E-1 air filter block. Cleani it. ... Emerson Quiet Kool 10NW16K Air Conditioner

18jc4e-a comes on but won't cool - Emerson Quiet Kool 18HT43 Air Conditioner


Check for a burn wire, open overload, or swollen leaky capacitor. ... Emerson Quiet Kool 18HT43 Air Conditioner

I have a Emerson Quiet Kool 10GV13 Air Conditioner the knob broke and I need a new one help!


1-800-673-1262 ... Emerson Quiet Kool 10GV13 Air Conditioner

I have an Emerson Quiet Kool air conditioner (Watt Watcher) and need to order a filter. However, I can't find a Model Number on the unit. Do you know where I might look?


... Emerson Quiet Kool 12GJ14 Air Conditioner

My emerson quiet kool Air conditioner is not cooling properly. Does it use freon or is there something else I can do to service this problem?


To get proper cool, keep the tips as follows:1. Check air filter is cleaned. 2. Check indoor coil is cleaned. 3. Checkindoor blower motor is working. 4. Keep in cool mode. 5. Set temp minimum 3degrees less than room temp.6.Check compressor is w ... Emerson Quiet Kool 10GV13 Air Conditioner