Fredrick heat pump p-tac window unit

\015 When outdoor tempeture is cold, and A/C is being used,defrost thermostat locking out compressor. Only way to reset is to pull unit out of case, take thermostat in hand and warm, after doing so compressor will come back on, but will not run long in cold weather. Is there any thing that I can do to resolve the problem. I have several units doing the same thing. I have checked all the electrical, and all parts seem to be check out fine. But still the defrost thermostat is locking out compressor. \015\012\015\012 Thank You,\015\012 Greg\015

Answers :

Need thermostst emerson quiet kool a c
I don't believe that's a defrost T.stat but a outside air lockout. it's there to save unit from slugging refrigerant. if they don't have a low ambient kit. most are adjustable.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Fredrick heat pump p-tac window unit


Need thermostst emerson quiet kool a c ... Kenwood KW85 Air Conditioner

I have a westinghouse window unit and I think it has heat strips for the heat. How do I tell if it is a true heat pump or if it has heat strips and how do I get to the Heat strips in the unit to check.


If it is a heat pump, the compressor will be running both in cool mode and in normal heat mode.\015\012\015\012Confirm the current indoor temperature. Turn the thermostat up one degree at a time until it comes on. This will typically be 1 ... Air Conditioners

I have a Rheem A/C Heat Pump split with gas backup. The gas unit is mounted in the air flow directly before the A/C HP coil. Should the gas unit be wired as stage two heat, or is it OK to wire it as just aux/EM heat? There is no other heating unit. What is the difference between stage two and aux? Please note that the aux gas heat cannot come on if the heat pump is running or it may hurt the heat pump due to the gas heat units location.


Stage 2 is okay as long as there is a fossil-fuel kit accessory wired in the field control wiring. EM heat would only allow gas furnace operation if the thermostat is set for EMER HT mode.......this is not ideal and not recommended. Dual-Fuel applic ... Air Conditioners

I have a Kewanee model#1736 hot water boiler furnance which is gas fired.I had to change the heat pump and the heat pump switch.The heat system is wired through a Webster Heating Contol unit which has three settings,Run,Auto,and Off.Normally when the heat control unit is in the Auto position the furnace and heat pump will start and run automatically until it reaches the desired thermostat temp. Then both the pump and the furnace would shut down at the same time until the thermostat falls below t


The thermostat turns the Boiler and the Heat Pump on simultaneously???....That doesn't sound right...normally the Thermostat brings on the heat pump first and if the temp continues to fall (Its Cold out) then the Boiler would kick in about 2 degrees ... Air Conditioners

We installed a Daikin heat pump in June 1996 Model FVY453CBV1 in Dunedin NZ. It stopped and a repairer said the compressor unit is rusted through & recommeneded a new heat pump. I am looking at whether there are alternative solutions and want to check whether it is economical to replace the compressors, or alternatively whether a new external unit can be purchased. Do heat pumps have a life in years? Is it risky to marry a new external unit to the existing internal unit? I appreciate your help


Don't waste your time and money repairing a 15 year old unit you will just create more \015\012headaches for yourself, And a new outdoor unit would not be compatable with your \015\012old indoor head there have been to many changes over t ... Air Conditioners

I have a Lennox model CB19-51-1P air handling unit with HP19-511-1P compressor heat pump unit. I just turned the heat on for the first time this season. And I am getting low heat volume. The heat pump unit is running for long periods. I am getting enough heat to maintain the 70 degrees setting with constant cycles, shutting off for short periods, running long periods. When the thermostat is turned to a cooler temperature, the unit shuts off as it should. Could you please help trouble shoot po


First thing you need to check is if the reversing valve is working you maybe running your A/C with the heat strips on depends on the t-stat your using some heat pumps will bring the strips on with a high d ... Air Conditioners

I have an NewAir 12000H Portable Air conditioner with a heat pump. The problem is that the heat pump no longer seams to be working. The desired temperature is 79 degrees. the unit never gets above 75 degree. when it actually gets that high it because my heat from the house has turned on. once the heat goes off then the unit goes down to 72 degrees and stays there until my heat comes back on. whats wrong with the unit? is there anything that i can do?


It sounds like the actual control module, the "brain", of this heater / air conditioner has failed and can't sense when to kick on the heat any longer. Have you tried just unplugging the unit for a good 5 minutes minimum and seeing if it will help " ... NewAir Air Conditioners

I replaced my outside unit with a 3 ton goodman heat pump unit. My old unit was a 3 ton bryant and the compressor burned up in it. I left the old unit under the house since it seemed to be in good condition. the pump worked fine on ac to start off. But then you had to switch it in heat and back to ac for it to work. So the tech replaced the expansion value and put filters in both lines. I still have to switch it back to heat to get the ac to work. The tech told me that i would have to repla


You said it had rwo filers on the line. I know one is a liquid line drier. If you have one on the suction line it need to come out ASAP. The trash in the line can be removed by running in cool.pump down unit replace drier. While the unit is pumped ... Air Conditioners

I have a gas furnace that was to have a 10acc air conditioner unit installed with it. Instead of the 10acc unit a 10hpr48 heat pump unit was installed, The house is 4 years old and the reversing valve has failed. The unit is not wired as a heat pump but as an ac unit with only three wires. A independent air conditioner repair company has said this installation is inproper.Is this unit installed to code and would lennox guarante a unit installed in this manner?


It should definitly be warrantied. their is nothing wrong with your set up however id have the contrator pull a new wire and go dual fuel withh outdoor sensor and get the full benifit of dual fuel. you should use the hp above 40 ... Air Conditioners

One year old window heat pump unit will not power


Is it not coming on? If it isn't, is the control pad lighting up? Is any of the electronics lighting up? If not, then the control board is probably bad. You will need to check voltages to the control board. ... Frigidaire FAC107P1A Wall/Window Air Conditioner

I just need to know where i can get prices on a FREDRICK heat pump Ptac unit


Your local hvac outfit should give you pricing tell them you just want the part if your installing it, if you are an hvac company united refrigeration or possibly grainger will have pricing they only sell to contracters as far as i know hope this hel ... Air Conditioners

I have a Ge AZ28E12DABM1 Heat pump Window Unit Front Fan Motor Will not Come on


... GE Air Conditioners

This is a heating and cooling through the wall heat pump. It works normally when heating is selected - the heat pump runs and both speeds of the fan blow warm air. But nothing runs when cooling is selected. In other words the unit works normally when "High Heat" or "Low Heat" is selected but nothing runs when "High Cool", "Low Cool" or "Fan Only" is selected. The position of the Fan Cycle Switch has no effect - behavior of the unit is the same in both positions of the Fan Cycle Switch.


You have a bad board or bad switch. I would say board. You can have service tech check this out. There is only so far you can go without knowledge of Controls ad electricity. Russ ... Air Conditioners

I have a GE ptac zoneline 4000 that wont heat on resistance but will on heat pump. It will heat when the unit has been off and the temp is below 40 f. after it has been on for 5 minutes the heat goes off but the heat pump keeps going. Checked all sensors and they all read about the same 6 k. If i put ice on the room air sensor the resistance heat comes on so I changed the sensor but, the same problem continues. This unit was made about 1994. Help Paul


... GE Zoneline AZ25E12D3B Air Conditioner

I have a goodman heat pump (gsh 130241AA), it's 2 years old. the heat pump will not come on in either heat or cool mode. this is my downstairs unit, my upstairs unit works fine. the air flow is working fine, just nothing cool with the downstairs unit.


... Goodman Air Conditioners

I have a whirpool window a/c and heat unit. The model number is ACE184XL0. The unit is 8 years old. It no longer cools the air like it use to. The unit heats well. Do I have realistic repair alternatives? I have been told the window units have no easy way to re-charge the freon and it is cheaper to replace it.


Try cleaning the air filter on the unit. ... Whirlpool Air Conditioners

Amana #PTC153b50AJ ser 0410686783 Customer heard a pop in unit and it went off. Breaker was tripped. Reset breaker and unit runs in a/c mode but does not heat in heat mode. This is not a heat pump but electric heat strips. Unit says there is a manual reset for the heat but we have not located the reset. We turned power off to the unit to reset fault etc and still no heat. The flashing light just blinks once every 4-5 sec. Could use some help in diagnosis Thanks DK


... Amana PTC153B50AJ Electric Heat Air Conditioner

Friedrich YM18 230 volt heat pump. The unit has heated and cooled well for about 5 years. Just started heating mode recently and the unit no longer heats. Fan runs OK. Was able to get the heat strip to run for a few minutes (smelled the dust accumulated over the summer burning off). Now, no heating whatsoever. When in the "Money Saver" mode, nothing happens. Fan will not come on and unit will not heat. With "Money Saver" mode off, the fan runs.


... Friedrich Air Conditioners

Mitsubishi MUZ-A42ANA heat pump and MSZ-A42ANA indoor fan unit worked like a charm for over a year. Still does. But the condensed water removal operation (A wall mounted 2”x2” mini pump, Sauermann SI3100UN-23, 230v 50/60 Hz 18w, Made in France, removes water through plastic tubing from the indoor unit to the roof mounted heat pump 8 feet above) is making a vibrating noise each time it is activated, about every 30 seconds or so. Water is being sucked out, bubbles inside tubing and all, but the


... Mitsubishi Air Conditioners

Heat pump shut off 1 to 2 minutes, service yesterday for same problem told low on freon. Added freon, worked fine until it went thorugh first defrost, now back to same thing. Tech says compressor not getting signal from thermostat. After resetting T-stat, unit came on. Unit works on cooling and Aux heat, but no heat pump.


It is possible that you have one or a combination of a few different problems here.If your heat pump will not come on but the air handler works, the first thing you want to check is that the circuit breaker and disconnect for the heat pum ... Carrier Air Conditioners

I have a 10 SEER heat pump about 16 years old, yesterday I notice that the outside unit was making a loud click noise in the heating mode. It's very close to the defrost electrical curcuit board. The unit still was putting out heat inside but decided to turn off the unit and use the emerg. heating. What could that loud clicking sound be? concern, Gilbert


Depending on make and model sounds like a check valve clicking. It can sound like it is coming from that area. You say your unit is 16 years old. Honeywell did servey on unit 10 years and older and found out they loose 25% effeicency after 10 years. ... Air Conditioners

My sister has a Ruud Achiever High efficency heat pump Model UPLA-049JAZ Serial #6408-M389910353 they just moved into this house in ND and have no information on this system..Over the winter it was very loud outside and they discovered alot of ice frozen on the fan blades and under but inside the unit. Where can they info for this unit and any suggestions on the freezup problem. Owning a heat pump is entirely new to them


There are 3 possiblites \012\0121. you have a bad defrost board or defrost sensor. \012\0122. Your low on Freon.\012\0123. Your coils and/or your Filter is dirty. ... Air Conditioners

Window unit LG-LWHD7000HRY7 fan and a/c works great, but it does not heat well. It took over 30 minutes to notice a little difference with temp outside of 25 degrees. Ventilation lever is closed to keep cold air out. There is nothing in the manual on troubleshooting heating problem. Would putting insulation board around the outside of the window unit help? Appreciate your help. Brent T.


Hi,There could be many Reasons. But, more often it seems that the Reversing Valve is not working. More often, it would be inside unit by compressor. Check the wiring to it for proper voltage.Let me know, if needed further assi ... LG Heat cool Window Air Conditioner

I have a RUUD 13pja42a01 heat pump. The main breaker in the house was turned off about a week ago. We have not tried to turn on the AC until today and the outside unit will not come on. The main breaker in the house is on as well as the heat pump breaker. I was looking for a reset button but cannot find one. Also in the box outside connected to the unit it does not appear that there is a breaker in there.


Check the small wires going outside to the contactor for 24 volts. If you have 24 volts then mayb ... Air Conditioners

I have a Janitrol Heat Pump Thermostat HPT-18-60 and need assistance connecting my new Honeywell RTH7500D thermostat I have a Goodman Heat Pump System Indoor Unit Model#AWB24-05C REV D Outdoor Unit Model#CPLE18-1 Here is the wiring of the old thermostat Y-Yellow Wire G-Green Wire R-Red Wire O-Orange Wire W2-White Wire E-Blue Wire C-Black Wire Where should each of these be connected to the new thermostats terminals?


... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"