Compressor hesitancy when the compressor want to starter, it has one or two attempt before begin.


Answers :

Possible run capacitor fault. Call a repairman.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Compressor hesitancy when the compressor want to starter, it has one or two attempt before begin.


Possible run capacitor fault. Call a repairman. ... Panasonic CW-C101MU Air Conditioner

My Carrier gas furnace (ser. 1903A41848) located in the attic, is five years old and suddenly won't light. IT cycles the fan when I cycle the power to the unit and seemingly attempts to ignite through 3 auto-attempts, (I can smell the gas), yet no continuous operation with heat occurs afterwards. Two lights exist on the exhaust vent both begin green yet one turns red after the ignition attempt. Please let me know your thoughts. -Doug


The igniters bad or if unit ignites the flame sensor is bad try this first ... Air Conditioners

I HAVE A TWO DOMETIC DUO- THERM 630035.321 ON MY R.V. SERIAL# 21631255 & 21631244 THEY WORK MOST OF THE TIME & SEEM TO COOL ESPECIALLY THE ONE IN THE BEDROOM BUT SEVERAL TIMES A WEEK THE COMPRESSOR JUST WONT CLICK ON YOU CAN WATCH THE AMP GAUGE ON THE WALL OR JUST LISTEN FOR IT TO KICK ON THEN IT COOLS FINE. IS THERE A STARTER CYCLOID FOR THE COMPRESSORS THAT COULD BE GOING OUT THANKS, BILL SHIPP


Check the capacitor for the compressor. It may be getting weak. You will have to remove the cover on top to find it. It will be an oval or round shaped cylinder. If it looks swollen it is bad. You can test it with a multimeter with the capacitor chec ... Dometic Air Conditioners

Zoneline 3100 I have a zoneline 3100 , and it seems at a certain temp. the unit shutts down , no fan , no heat . After a few days the unit will begine to run normal again . I have attempted to have it looked at by several heating and plumbing co. but no one wants to work on it . I'm thinking it may be a sensore issue ? Can you help please ! It'a very cold here in Weastern NY . The temp it seems to quit at is around 30-40 degrees .


Check on / off switch.\015\012wiring of unit\015\012there is loss connection ... Air Conditioners

Sometimes when the humidifier attempts to start it just howls for a minute or two and then quiets down and runs normal -- OR If I hit it with my hand it also quits howling and begins running normally. It doesn't do this every time it starts - only occasionally. I though it might be the motor temporarily getting out of alignment, but then what do I know. I just don't want to buy a new motor for nothing. .


Yes, you got it spot on - the bushings on the motor have worn out and the fan is slightly out of balance. When it rotates at high speed it autocenters, this is why you hear this only during startup.Before replacing the motor take it apart, you ... Air Conditioners

I have to replace the start/run capacitor (97F9971 - Duel Capacitor/ 50, 7.5 370 VAC). I have marked the terminals before removing and purchased the new capacitor. The new capacitor has minor difference with the old one. The hermatic has 3 terminals, The Fan has two terminals The Compressor (C) has 4 terminals. Now in the old unit, two wires were connected to two opposite terminals on C, one in Herm and one in Fan. My question is: How will I know which terminal to connect in the new one


All the terminals are connected together so it won't matter which terminal you use, just as long as you have the Herm, Com, and Fan wires correct. Hope this helps! ... Air Conditioners

A) I am trying to obtain a manual for a model #HWR12XC6-RB air conditioner. Can you send me one via email? B) Although it seem to run, the compressor only seems to run for a minute or two before shutting down for a time. Then it restarts. The temperature display seems to decrease while the compressor is running, and rises again when it is not running. The temperature never seems to aproach the set temperature. C) There are two types of noise I wasn't expecting. One seems to be a kind of klunking


... Haier HWR12XCB Air conditioner

I Have a outside A/C unit I have replaced the fan and I need to know which Capacitor leads go to the Fan, the compressor and the contactor. the capacitor is a 35/5 with one lead with 4 male blade connectors-one with two and one with only one lead. There are also two brown(one with a stripe)wires from the new motor instead of the one on the original motor.


The 2 brown wires go to the capacitor, the solid on the positive or colored dot side, the striped one goes on the other side. ... Dayton Air Conditioners

I have a Goodman Co. air handler model #AWb24-OBC REV E. I had to replace the fan motor and want to make sure it is wired correctly. There are five wires one red, one black, one purple and two brown. I know the two brown go to the capacitor and the purple to the 30 amp breaker. Does the red or the black go to the BTDR?


... Goodman Air Conditioners

I have two compressors-one for the upstairs and one for the down stairs. Both compressors are working but the air flow for the upstairs basically does not come out. You can hear the unit running but no air upstairs. Down stairs the air is working. Is there any way to turn the airflow up or adjust it to send more air upstairs. I had the capacitor replaced in the down stairs compressor a few weeks ago and for the upstairs about 1 1/2 years ago. when the air downstairs started working a few d


Hello,Thanks for using FixYa.I suggest that you try to have the fan that routes air upstairs checked. Its possible that the motor is already going bad.I hope this helps. Thanks and good day.HotRatchet ... Air Conditioners

I HAVE A HEIL HEATPUMP.CONDESING FAN MOTOR WENT OUT, WHEN I WENT TO UNHOOK IT I NOTICED A BURNED CONNECTION ATABIG CAP. GOT THE CAP AND MOTOR NOW THE BLOWER MOTOR DOESNT COME ON. THE GUY SOLD ME A TWO PRONG CAP AND THE ONEI HAD WAS A THREE PRONG. TWO WIRES GO TO THE COMPRESSOR AND ONE APPEARS TO BE GOING TO THE CONTACTOR. BIG BLACK PLASTIC BLOCK, THE OLD CAP HAD THESE NUMBERS ON IT 60+7.5uf 370v 50/60hz 70c the new one says 60uf+- 5% 370vac 50/60hz sh po 40/75/21. My question is could this new c


A commom wire comes from the top of the contacter , attactch this wire to two prong cap, then attatch what is usually a brown wire to the other side of the cap , find coommon wire from fan motor and attatch it to the same side you attatched the commo ... Air Conditioners

AC Out. Two year old house. Goodman A/C, two units one for upstairs. Cleaned coils of both outside unit, replaced filters, re-set breakers. Upstairs is cooling. Downstairs unit is running outside, not circulating air inside (inside temp 87). Vents inside are cool to touch, no air. Outside unit fan is pulling, but air exhaust is cool. Compressor ? Should air be circulating even if compressor not functioning. Is there anything in attic exchange that would affect downstairs circulation. Thanks.


Assuming that the 2 systems are isolated, that there isn't any cross over between the systems...It is normal for an air conditioner system, from window unit to central, to be able to circulate the air, even if not cooling. This is known ... Air Conditioners

Hi, I have a 1.5 ton Coleman Central AC for almost 9 years now. The AC stopped cooling one day. The fan is still working, and I can still hear the compressor "compressing" but no cool air. Does that mean that it is not a compressor failure? A technician tried to put refrigerant into it, but it won't absorb. He still wasn't able to fix it. I just wanted to know if I should spend more money to get more technicians to try to fix this, or if this is a classic compressor failure problem, then


Hello,the problem of the AC system is a little thing that can be fix up in a little time the fan is OK and the compressor is also in good condition base on experience and also collection of date from your statement however, w ... Air Conditioners

We have a Goodman CKL49-1 - 10 Seer - 4 Ton Condenser. One of the wires that fires the compressor keeps burning and, of course, the compressor won't come on. It is beginning to happen every couple of days. Should we bite the bullet and go ahead and replace the compressor or could something else be causing this problem?


A bad connection in the power wiring, the circuit breaker, disconnect, capacitor(s) or in the compressor contactor (worn contactor) can cause this due to very high resistance and subsequent heat production. If the unit will run, it should be amped c ... Goodman CLQ36AR49 Air Conditioner

I have GE AJES12DCBM1. Recently after one of the storm, it stopped cooling. Fan motor comes on. Compressor is also kicking on but it kicks off within a minute or two. Is it possible that the capacitor may be a problem or compressor itself?


Check inside and outside coils for cleaning with coil cleaner sprayCheck capacitor(remove and take to appliance parts dealer. They will checkit)If this was helpful please rate me.Leo Ponder Appliance-Tyler,Texas ... GE J AJCS08AZ Air Conditioner

My Gibson 3.5 ton heat pump died (might be compressor); however, the air handler is just fine. I've found a Westinghouse 3.5 (HS042ABS) (same voltage and handler requirements) and I want to know if I can ''hybrid'' the two units together. Never mind warranty warnings and all that. Just can I hybrid the two units?


Hello,By all means you can! The airhandler will not mind at all.The freon used MUST be the same.If the old compressor had a BURN OUT please install new filter/driers in refrigerant piping.Hybird meaning just different ... Air Conditioners

I have a Panasonic 11,500 BTU Window A/C for my bedroom. It does not condense any water on humid days and the thermostat keeps cycling on/off. The model is CW-XC120VK. My living room model compressor is on constantly trying to make up for the larger model and I can see the water dripping out the back. The compressor on the big one does come on, but just then shuts off and my bedroom temperature rises above the set 23C. This is a two year old model. Help!


\015\012Compressor starts and stops in seconds\015\012There are Five Main reasons that this will happen\015\0121 - A bad run capacitor (silver or metal capacitor)\015\012It’s either shorted, grounded or open.\015\0 ... Air Conditioners

There are two wires,brown and blue to control ac unit. One to start compressor and one to start blower motor in furnace.They are not labeled and do not match terminals in furnace.


Some times field wiring will be of different colors. Green is always for ground. White or gray is neutral and almost any other color can be hot. This is only for higher voltage. The furnace is supplied mainly with 110 volts and transformed to 24 for ... Air Conditioners

Hi i h have gree airconditioner but is alredy has been fixed on outdoor but the problem is if i want to take of but is two pipe going on side ways there is one is gas but other one liqut. But i dont know whats is liqut can you tell me please


The liquid is the thin line and the gas is the thicker one. ... LG LS-L1210CL Mini Split Air Conditioner

I have 2 kenmore air conditioners, each has a power cord whose plug has a built-in ground fault/reset device. I wanted to shorten the cords, so I cut off the plugs and installed regular heavy-duty three-prong plugs. They are wired in correct polarity. However, on one a/c the compressor will not turn on. On the other, it's working but there is excessive fan noise. Did i do something wrong?


That ground fault ... Air Conditioners

Hi,I am really hoping to find someone to help me if possible. I have a one year old carrier infinity 4ton 17seer condenser and a 5ton variable speed air handler. I has worked fine but now i am getting a SYSTEM MALFUNCTION on the thermistat. When this message appears the air handler continues to blow and only the fan on the condenser continues to run but NOT the compressor so it is not cooling. At times it begins cooling again but then later stops cooling and shows the same malfunstion message. I


Hi,\015\012If this si what I am thinking it is, it will be very hard to find and prove.... \015\012The compressor windings have aflat spot and if the motor stops at the right place it will not atart. The voltage goes way up and kicks out ... Air Conditioners

One of my customers had a goodman vsc060 compressor installed and I wanted to know if that is used in commercial also and how reputable of a unit it is compared to trane or other well known names.( His tenant had it installed without checking with him first) He has a service contract with ECM but it was fourth of July weekend and they own a restaurant and thats the brand thats in the restaurant. I really need to tell him if its good or bad


Goodman is are decent (builders grade) equipment. Not as good as Trane or Carrier but if it's installed correctly it should be fine. Goodman is mainly a residential brand but they do make some light commercial equipment which again is decent as long ... Air Conditioners

My AC wouldn't come on 2 months ago. I called a company to look at it. They said that the capacitor had gone out. When they went to replace it, they didn?t have the right size so they used two capacitors instead of one. A month later my compressor went out completely ? burned wires and everything. My question is could the previous fix have caused this latest problem?


Previous fix would not have caused the compressor failure. Most likely the compressor on its way to failing actually caused the original capacitor to fail. The 2 capacitors together is the usual fix when a dual capacitor is not in hands reach. ... Air Conditioners

Fan nor working on the outdoor unit.Hisense HFR 0922 split cycle air con. Double checked the wiring and is OK according to instructions in manual. Compressor working, but fan won't start. This is the second unit we have intalled. The first one replaced straight away by ''The Good Guys''. Replacement appears to have same problem. Beginning to suspect we've missed something in the wiring? Has anyone experienced the same problem please?


Check capacitor and the fan control board. Do you have active and nutral from the board or does it get power from the comressor contactor? ... Air Conditioners

Where can I find a compressor for my Ruud Achiever 10 seer? Been waiting for the service guy to come back with one- been two days and with inside temps avereging 87-89 degs- cant wait any longer lol


... Ruud Matching Split Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0812 seconds