Having problems with your Air Conditioners ?

FAN DOESN'T GO ON

\015 The unit turns on, but no fan.\015

Answers :

I think the connection from pcb is lost so fan is not switching on so i think you should not try to solder it rather try to change the fan

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

It is not cold. The fan works but when the cold air should come on it doesnt. You can hear it trying to kick on for a moment but it doesnt, it just keeps blowing as a fan. Thanks for any help. I would even buy another one of the same model if I could find it but that doesnt seem possible either.


If compressor is not shorted out to the ground and between each leg of compressor multimeter reads resistance You could try to install 3 N 1 hard start kit. But most likely compressor is weak, be prepared to replace compressor soon. Here is my situat ... Frigidaire FAS185M2A Air Conditioner

I have a goodman Air conditioning unit CKL49-1. The fan motor connects to the top lid. Recently the metal cracked and broke and the fan fell down inside. I purchassed a new lid mounted the fan back on to the lid. It doesnt seem that any major damage was caused. I put everything back together the way it was. When I turn it on it will only go on for a sec then a switch inside turns it off. When i looked at the electrical on the ac i noticed when i turn it on a little spark on a switch and the swit


Sounds like it is overloading and tripping the circuit breaker (that thing that pops up). More than likely when the fan fell down it stopped the blade from turning which caused the motor to overheat, melting the windings insulation which caused them ... Goodman CKL49AR49 Air Conditioner

Our Furnace doesnt seem to be working correct. We an: Air Pro BGM075128 and is Natural Gas. It will turn on when we turn up the thermostat.. but we never get any heat through the vents. There is a switch on the side that is "on" and one that is "fan". If we turn on the "fan" only cold air gets blown through. It looks like this is for cool air. So, if we leave the fan off and the "on" swith on, we get the furnace firing up, but no heat ever comes through the vents. I tested out the thermo


Sounds like the blower motor is not working, if the furnace is actually lighting up and the burns are ignited. You should set your thermostat to auto, as if it is on fan then the fan runs all the time until you take it off of fan. I am a little confu ... Air Conditioners

COLMAN TSR I JUST BOUGHT A HONDA EU 3000 IS THAT I WAS TOLD SHOULD RUN MY AIR CONDITIONER WITCH IT DOES FINE UNTIL THE COMPRESSOR STARTS CYCLING. WHEN THE COMPRESSOR TRIES TO TURN BACK ON IT TRIPS THE OVERLOAD ALARM. I HOOKED IT TO THE HOUSE AND IT DOESN'T TRIP THE CIRCUIT BUT WHEN IT TRIES TO CYCLE THE FAN DIES ALMOST ALL THE WAY OUT FOR ABOUT 5 TO 10 SECONDS THEN THE FAN STARTS RUNNING OK AGAIN BUT NO COLD AIR FOR ABOUT 30 SECONDS THEN IT CLICKS FAN DOESNT CHANGE AND COLD AIR RESUMES. THAT LAS


3000 Watts is a little short on the power necessary for the compressor to restart. When it compressor starts it may draw 27 amps or more for a split second. 3000 / 120 = 25 amps. when the fan slows down it is telling you the voltage has dropped and i ... Coleman Mach 15 Air Conditioner

Compressor kicks on but fan doesnt turn on. Fan freewheels fine


Need to look at the name plate glued to the unit, most units are 220 volts AC. ... Dometic Rooftop RV Air Conditioner

My Carrier Home Central Air Conditioning Model Number 38CKC036 340 fan out side the house is not working it gives oout a low humming sound and fan doesnt rotate Serial Number 4698E05846 Manufacturer CARRIER Model Number 38CKC036 340


Hi,\012If the fan is humming and not running them it has gone bad....it will need to be replaced...not all that difficult a job...most pro's do it in less then an hour...\012\012Here is a tip about trouble shooting your ... Carrier 38CKC036 Air Conditioner

Carrier Aircon WCARG010EE 1 HP (remote) It seems the fan doesnt work, and the remote doesnt work. and there is an Fr that keeps blinking.


You must check if there is power to the fan to confirm if there is failure of the fan motor. Since the FR display indicates there is possibility that the power is initiating.\012If the remote unit is not powered from t ... Carrier Air Conditioners

KELVINATOR KSR20C Our split systeme air con does not heat or cool the outside fan run when on but the inside fan doesnt run the little led on the circuit board on the outside unit is blinking on for 3 sec ond off for 3 sec do these air cons have a fault codes ??


One might think so, YES! look on one of the door panels that you can remove! Thank-you-very-much! ... GE Zoneline AZ38H12DAD Split System Air Conditioner

I have a Coleman Evcon Air Conditioning Unit....for the FAU ...I have to remove both front panels and manually have to turn the fan to get the unit working...my question is....would this be some kind of problem with the relay between the thermostat and the FAU ? when I spin the fan blades by hand...it doesnt seem like it is rubbing...I have never experienced this problem...can somebody please help me??? I would truly appreciate it ! :)


Hi,\015\012\015\012As you rotate the fan blade it start workin.This is not a realy or thermotat problem.The problem is with the motor of the fan.Replace the motor and it will work fine \015\012\015\012Thank You ... Air Conditioners

My ac unit doesnt cool anymore. I've cleaned the filter and its spotless but cool air doesnt come out at all, its like an expensive fan. Is it out of frion?


May be your compressor, a cap or freon ... Danby DPAC7008 Air Conditioner

AC UNIT RUNS AND ALL OF THE SUDDEN FAN STOPS AND COMPRESSOR WILL RUN A LITTLE WHILE AND STOP. THEN FAN STARTS AND COMPRESSOR KICKS IN AS NORMAL. ONLY HAPPENED A FEW TIMES, BUT I DONT WANT TO WAIT UNTIL IT DOESNT WORK AT ALL. ITS A 15000 BTU COLEMAN. COULD THIS BE A CAPACITOR PROBLEM???


Check the condensor unit. May be dusty. Clean it. If still problem replace capacitor. ... Coleman 15000 Btu Rv Roof Air Conditioner With Heat

My carrier indoor blower motor trys to engage but doesnt. slowly spins cw then ccw..even with heater or ac off..Just fan on..it does turn off if you turn fan off...model #fv4anf003


... Carrier Air Conditioners

When I turn my unit it on it makes a sound like its going to switch on but then nothing happens. The fan does not turn, the AC doesnt turn on, and the Heat turns on (cause I can feel in the inside), but it doesnt blow


Low on freeon ... Frigidaire FAC124 wall/Window Air Conditioner

My a/c stoppped working, model fas257s2a, compressor doesnt turn on I thought it was the boards replaced them still doesnt turn on fan works but comp. does not kick on, checked capacitor 40/8 reads 39


... Frigidaire FAS257S2A WallWindow Air Conditioner

Pentair DV 400 gas heater.. kicks on and cycles through but shuts right off. E04 fan failure message but fan is working fine. sensor tube doesnt have any holes and is patent. need help now!


... Pentair Air Conditioners

I have a ruud model # UAMB-030JAZ.The outside compressor kicks on when I push the high pressure reset button but the fan doesnt kick on. How do I test the capacitor and the fan motor if those may the problem?


I service HVAC systems pretty regularly as part of my job at a large apartment community... if you think the runcap is at fault just replace it, they cost about $7-10 (be careful they can hold a charge even when power is off)\015\012\015\ ... Air Conditioners

The fan ouside doesnt turn when the system requires, the compressor contactor clicks but does not set the fan motor running


Change fan capacitor. ... Air Conditioners

My problem is with frigidaire air conditioner model fah126r2t. the digital electronic panel doesnt work, power button doesnt work either (no buttons work on panel). but the fan will not stop spinning when unit is plugged into ac


I am not too familiar with these systems but, it sounds to me like it may be in a safety lock out mode. Possible failures:Fusible linkon board Surge protectorfaulty circuit board ... Air Conditioners

I have a heat pump and a new condenser Payne made by Carrier was installed 7/12. My problem is I live in east coast and I notice that the condenser is on but the fan doesnt turn on in synch with condenser. Called a contractor but they said it is motor problem in the blower and it was changed. That didnt solved the problem,I notice that the condenser will turn on and the fan will turn on maybe after 10 min.Need some advice pls.. t


... Air Conditioners

Everstar mpk10cr grinding compressor I think.... Fan works fine, will kick into cool mode (elevated fan level) for a few seconds then it sounds like the compressor has a loose mount or something... sometimes it rattles for a few minutes (and cools) but sometimes it shuts the rattling off as fast as it starts and doesnt really ''cool'' or dehumidify.... Some days its works fine all day, others it just never really gets its ''**** together'' so to speak... Can users recharge the coolant themselve


Hi, I hear you , you have to keep her happy and cool!! First of all, no you can't buy R-22 unless you are a contractor and you have a certification card showing you are qualified to use freon. This is not your problem from what you are saying. If thi ... Air Conditioners

Trane xr12, fan works but compressor doesnt come on.


Check the capacitor and contactor. You may have wires burnt at the compressor terminal from corrosion. ... Air Conditioners

Air compressor kicks on but fan doesnt and vice versa


I assume you mean the condenser fan motor ? Try to manually spin it. If it is hard to turn, change the motor. If it spins freely, change the capacitor. ... Air Conditioners

I have WEATHERKING AIR CONDITIONER MOD. 10AJA36-1the fan doesnt stop when the compressor shuts off .I have change the contactor and the thermostat


Which fan are you speaking of?the stat would be indoor fan, while the contactor will be the condenser fan motor! ... Weather King 12AJA4801AH Air Conditioner

Condenser on my air conditioner comes on but fan doesnt.


... Whirlpool ACQ158XP Wall/Window Air Conditioner

Fan Runs, AC Doesnt, Blinks 5 times


Need to look around and should have an error code and give more detail of what the problem is. If you post that i can maybe help you more. I need to know...... ... Dometic Rooftop RV Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.0468 seconds