When it works on hi cool after sometime the blower stop but compressor still working .my aircon is window type.


Answers :

Replace the thermostat. The thermostat is shutting down the blower and not shutting down the compressor. Also replace the relay on the compressor as this should be replace when the thermostat is replaced to make sure both are in working order

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

When it works on hi cool after sometime the blower stop but compressor still working .my aircon is window type.


Replace the thermostat. The thermostat is shutting down the blower and not shutting down the compressor. Also replace the relay on the compressor as this should be replace when the thermostat is replaced to make sure both are in working order ... Air Conditioners

I have a window unit i just put in it is one year old and has not been used this summer it is only blowing room temp air and the it is on the cool setting and willl only work on high settign and auto i tried the reset button but the compressor still isn kicking on to get the freon in the unit working


If the unit is stored in any position *other* than the intended, normal operating position, the unit will not run correctly.Cooling appliances with compressors for refrigerants such as A/C units, refrigerators, freezers, etc., whenever mo ... Air Conditioners

Everstar mpk10cr grinding compressor I think.... Fan works fine, will kick into cool mode (elevated fan level) for a few seconds then it sounds like the compressor has a loose mount or something... sometimes it rattles for a few minutes (and cools) but sometimes it shuts the rattling off as fast as it starts and doesnt really ''cool'' or dehumidify.... Some days its works fine all day, others it just never really gets its ''**** together'' so to speak... Can users recharge the coolant themselve


Hi, I hear you , you have to keep her happy and cool!! First of all, no you can't buy R-22 unless you are a contractor and you have a certification card showing you are qualified to use freon. This is not your problem from what you are saying. If thi ... Air Conditioners

Works dosent cool compressor still works maybe recharge


Make sure filter and inside and outside coils are clean ... Sharp Air Conditioners

HI I just got a second hand samsung split type aircon. I had a guy here to gas it. now it goes on, but 10 mins later the compressor switches off fan still runs. It also does not seem to cool very well


Did they put the right gas inside? to help further can i have the model mumber ... Air Conditioners

Hi, I have a 1.5 ton Coleman Central AC for almost 9 years now. The AC stopped cooling one day. The fan is still working, and I can still hear the compressor "compressing" but no cool air. Does that mean that it is not a compressor failure? A technician tried to put refrigerant into it, but it won't absorb. He still wasn't able to fix it. I just wanted to know if I should spend more money to get more technicians to try to fix this, or if this is a classic compressor failure problem, then


Hello,the problem of the AC system is a little thing that can be fix up in a little time the fan is OK and the compressor is also in good condition base on experience and also collection of date from your statement however, w ... Air Conditioners

Hello, I have two Yokohama Split type air conditioners that work fine for cooling, but when switched to heat they just blow air at room temperature and then after about 1 minute go into a standby mode indefinately. They work perfectly for cooling. All fans work perfectly and the compressor works perfectly for cooling. Thanks...


... Air Conditioners

I installed a 2400 BTU Senville mini split ac unit about 6 months ago and until now, it worked great. Tonight I noticed my room getting hot and looked up at the wall unit and it was flashing "f5" I think? I turned it off and on and it seemed to return to normal with 65 degrees displayed yet when the room stayed hot, I went out and looked and the compressor was not working. I flipped the breaker and still nothing, went inside and turned it on and off again, still no compressor, no cooling. Thanks


... LG LS-K1830CL Cool Mini Split Air Conditioner

I have Jaguar S-Type 2000, and I am facing a problem in the Air Conditioning System. When I switch On the A/c, the compressor sometimes works and sometimes no. Also sometimes it works for a while, for a short period of time and then it goes Off. I replaced the (Relay), but the problem remains. I hope you can help me defining this problem. Thanking you.


If it is low on Refrigerant, it will cycle the clutch off. When the pressure rises from the lines equalizing, it will come back on. When it does stay running, does the larger line get cold? If not, it is probably low on refrigerant. Roger ... Jaguar Air Conditioners

I have LG Art Cool LSP 122A problem is after turning on works for 5 min. and compressor cuts out and won't turn back on again , indor fan still runnig. After pressing operation mode selection button and skipping operation mode compressor will start again but work only 5 min .


... LG Air Conditioners

I have a Lg LWC122RH-2 Window Reverse Cycle Air Conditioner. It is 5 years old. The fan works fine. The Cooling and heating don't work. When I turn it on to cool setting, I can hear the compressor trying to kick in and a popping sound and can hear the unit go up and down a bit, like a humming sort of sound.


Think yu must take your compressor to the specialist so that they can check if cycling valve is operating. or may be wiring problem to the valve. ... LG Heat cool Window Air Conditioner

Hello I have an LG window unit, model LWHD8000RY6 I hooked it up yesterday after having it in storage for the winter- dry, clean storage in my basement. It worked for about 2 hours, then the compressor turned off. The fan still runs, all of the display lights & switches function. I can hear the compressor trying to turn on, but it gives a quiet click-hum and then stops. The fan is still running, but no cold air. Any ideas?


... LG BG8000ER Air Conditioner

Unit runs but will not cool. Fanruns fine but when turn dial to cool the compressor kicks in for about a second or two the kicks out. Fan works on cool but it will not produce cool air at any temp setting. I have cleaned filter and removed cometic facing and vacuumed the coil face. It was pretty dirty but after all that still would not cool, Unit is installed in a RV and power is provided from house. Gen4erator is also available for power. Unit is difficult to remove from RV and space to get at


You may need to install a hardstart kit if you can get to the compressor.\012go to your nearest appliance parts store to get the part and the instructions are usually on it. If not ask the parts man.\012\012If this was helpful pleas ... Air Conditioners

Air conditioner runs for a few hours and it works - it cools the house. Then it stops cooling - the fan still runs but it doesn't blow out cool air any more. It seems like it's overheating or something. It will blow out cool air if it has not been turned on in a while but once it's on too long it stops. I was told it could be the fan motor and the a/c guy changed the fan motor today but that didn't fix the problem. Now he says it might be the compressor or that I need a new system. I'm jus


The things I would check:\015\012Is the system properly charged with freon? Sytem may be overcharged.\015\012Is the compressor out on internal overload at the point of failure? If the overload isnt tripped and the compressor is having tro ... Air Conditioners

I also have a grunaire dual zone mini-split that doesn't work worth a ****. I've had it looked at multiple times and had freon r410a added twice and still nothing. Without the high side - how do you know if you put too much or not enough. I also have a long run on one system being over 25ft from the compressor so its a longer run - but that one at least worked for a moment - the short run - never worked. Get the FC fault consistently on one unit - other unit just doen't blow cool - how do yo


An FC fault on a Grunaire is typically a defective PFC board in the outdoor unit or a Grossly overcharged system, where the drive cannot overcome the standing pressure to start the system up...the ONLY CORRECT way to charge one of these u ... Air Conditioners

Hi My Danby 6000 BTU window air condition is not cooling. I set thermostat to maximum cooler level as 8 but still not cooling room. I clean all the dust with wire brush. Fan is working fine and I can feel lots of air comming through the air condition but no cool air.


... Danby DAC6003D Air Conditioner

My KOLIN window type remote control AIRCON is building up ICE


If you already had the coils and filter cleaned and the blower is OK, that only leaves the refrigerant charge.\015\012You are probably low on refrigerant. ... Air Conditioners

My window type aircon compressor run for 5 min,then stop for 4min,then run again for only 5 min even if the thermostat is set to the coolest setting and the the room temperature is higher than 30deg.C.it always run in cycle of 5min. on & 4 min. off.My aircon is PANASONIC CW-XC71JPH.(Remote control)


I have the same problem w/my CW-XC122VU. Other symptom is that the thermostat setting does not work in this "poltergeist" mode. After the problem went away by itself, then re-occurred, I notice it tracks the level of the water in the pan. A full p ... Panasonic Air Conditioners

My carrier A/C YHB243D this window unit was working find. But about one week ago only blows out cold air and sometimes only hot air but now it blows only regular air, and doesn't work nither the cool or heat air. what could be wrong with it?_a) could be- the thermostate that goest at it front with its condenser unit? b) could be the whole temperature switch ? or what else can be its problem, please help! and tell me where I can get the replacement part


... Carrier Air Conditioners

Hi, I have a samsung aqv18ja series split type air conditioner (cooling and heating) wall unit. the unit was install in 02/12/2009. By "one hour heating and air conditioning". In this short time service the outside compressor has been replace, the system has check and recheck,for cooling leak. the inside unit fan motor has been change. but the problem still exists. The inside unit fan continues to run when the unit is "off" and with the remote off.


Simple, check in your remote. There is an option button "Blow". Just press it. Your unit gets completely off. Please write back if helpful? ... Samsung Air Conditioners

The water empty indicator keeps flashing indicating we need to empty it BUT it is empty !!!!Now the aircon won't work We emptied a lot of water however now it keeps beeping a warning,the compressor shuts down and no cool air is produced although the fan is working. It is 38 C in our house and we are desperate !!! Help


I am NOT aquainted with the Maytag Portable AC..... But There has to been a sensor that tells the unit that the water bin is full...... If there is any moisture on the sensor and touching a ground probe then even though the bin is empty the sensor i ... Maytag Portable Air Conditioner M6P09S2A

Frigidare window air conditioner with remote control about 3 yrs old. All controls seem to be working except when the energy saver mode is suppose to shut down the unit / the display goes dark but the units compressor seems to be still running after shutdown?? Unit will not shut completely off unless we unplug entire unit. Unit also has a built in safety breaker switch on plug which works fine. Any suggestions?????


Hi,There might be many reasons. One of them would be Thermostat. If there is an issue with thermostat, ac would show the above symptoms.Check and let me know.Hope i helped you.Thanks for using ' Fixya ' ... Air Conditioners

Heating Problem Hi , My split (2 Piece) aircon is not producing Heat, but its' working on cooling. I put it in heat mode and 30 Degrees still not working for heat. What might be the problem? Please help me in regards to this. -CHAD


Put it in heat mode and check the pipes to outdoor unit,if the pipes are white from ice then the problem is to outdoor unit and is the coil of 4valve.its like a cube with 2 cables,change it. ... Samsung AS18A6RB Air Conditioner

The PAC-260 runs for a few minutes, then I hear the compressor stop and it spews hot air. Pressing the reset button fixes the issue only to have it be reset again after a few minutes. Air filter is fine, the tubes are setup properly (ie. it is a straight run up and into the window). What am I missing, the reset button is supposed to be used when I figure out what is wrong, but I know it works (sort of) because when it works it still is very cold.


I had exactly the same problem. After some diagnosis I discovered that the water pump was not engaging so I checked the float switch, it was fine. \012\012A press of the red reset button turned the compressor back on for a few minutes but the ... DeLonghi Pinguino PAC-260 Air Conditioner

I have a hampton bay window unit that is 220. I can't find a model number, but the unit is about 5 years old. When I turn it on, I can hear the compressor come on, but it doesn't cool. I have tried to clean the unit with a water sprayer, and then lubricate the fan, but it still won't cool.


... Hampton Bay Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1810 seconds