Having problems with your Air Conditioners ?

No power to the tstat on my ac/heat unit

\015 All breaker s are on,but still no power to thermostat\015

Answers :

Do you have split system or what If it is the split system you proable will find a transformer bad.Or a fuse blown on the transformer.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

No power to the tstat on my ac/heat unit


Do you have split system or what If it is the split system you proable will find a transformer bad.Or a fuse blown on the transformer. ... Air Conditioners

Hi. I have a LG heat pump/air conditioner. A split system with 2 indoor units. Model LMN095HV and LMN125HV. After a power failure by our local power company, I am getting a CH 05 error code. I have turned off th power to the units and waited several minutes and turned it back on with no luck. I know the code means poor or no communication with the outside unite. And I am getting the same code on both inside units. an you help? Thanks, Peter C [email protected]


Hi, this error is a communication error between your indoor and outdoor unit, check all wiring and connections - ch 5 is a communication error between the indoor unit and the outdoor unit.\015\012You can try turning the breaker off ... LG LSC183VMA Split System Air Conditioner

I live in central fl We have a older tempstar electric heating/cooling unit there is power to the indoor part and the heat works. I have power to the inside breaker for the cooling but no power to the outside unit breaker. theres no power to the outside unit at all.


The outdoor unit should have it's own 220 volt breaker, and on the wall near the outdoor unit should be a disconnect box, some disconnects have breakers, others have just a disconnect bar, and behind the metal plate are fuses.\015\012I would c ... Air Conditioners

The unit will not start using the buttons on the unit or the remote. I removed the power for up to 12 hrs. I pushed the test and reset buttons on the circuit breaker at the wall power cord. I have power by the display panel showing error code E1 I have pushed and held down all of the buttons on the unit. Still will not start and continues to display error E1 This unit was purchased in June 2007.


Replace indoor temp sensor. ... Haier HPR09XC7 Portable Air Conditioner

I found the Bryant furnace 395cav048090 calling for heat but not operational. I shut off power to the unit and switched power back on and the unit started its ignition sequence. With power on the blower starts as a result of thermostat calling for heat from the unit and after a minute goes on to second phase of ignition with exhaust blower motor initiated. During this phase gas is being brought to the burner that you can smell however burner does not ignite gas. Unit continued with this opera


If you do not see a bright light before the gas releases, your ignitor is probably out. If you disconnect, you should measure ohms from the two ignitor leads. If you do not measure any, it is open and will not work. You will usually see a mark of whi ... Bryant Air Conditioners

Not a GE unit. I charged unit with refrigerant and powered up unit. After running for @ a minute it shut off, having no power light at all. I found a set of wires reversed that were going to the outdoor unit. after fixing the wires i can't get the unit to come back on. The breaker is not popped and I assume there is some kind of fuse or overload that I have to manually reset or replace. It is a chinese (i think) made unit Air Control


Since most of these units, come precharged for line sets up to 125' in some models, the fact that you charged it, concerns me. Second you made no mention of the king valve, did you open it.\015\012 Then your diagnosis speaks to overvcharge, an ... GE Quiet-Aire Ductless Mini Split System Air Conditioner

AMCOR 24,000 BTU split system. Worked fine two years, then today it had no power. Checked circuit breaker, it had popped. Reset CB and went to inside unit - would not turn on or off with remote or hard button. Checked wiring with an electrical tester, and wires to outside unit hot, as well as inside unit. No flashing codes, nothing. Unit won't turn on,even with power. Is there a fuse somewhere in the inner unit or outer unit?


I had this same problem. I disconnected the thermostat wire out side at the condenser and reconnected it and it started working. A couple days later it blew the breaker again this time I found the bus where the L1, L2. GR wire connect at the condense ... AmcorAire UCHW-H24AF2 Split System Air Conditioner

I want to find the transformer for the 36 volt inside unit. Is it in the inside unit or outside unit .I have no power to the inside unit however the outside unit has power,and the inside unit appears to be 36 volt


It's a 24v transformer. Your indoor unit houses the transformer for the outdoor unit. The outdoor has a low voltage (24v) supply running to it to push in the contactor for the outdoor unit to run. If your air handler inside has no power then it will ... Comfort-Aire HMC36AT-1 Air Conditioner

After experiencing a power outage in our home, our LG Heater Unit stopped working, there is a blinking code displyed CH 24. I've shut off power to the unit several times, units appears to reset for 10 minutes then the shuts down and the blinking code appears again. I've tried letting the power of all night the issue is still present. Any suggestions. Thanks


... LG Air Conditioners

AC unit Amcoraire AOS241HX @ startup i have power to the L1, L2 power inlet terminals to the outdoor unit but no power to the lines going up to the indoor unit. What can I do to correct problem?


These should be seperate circuits so lets forget the condensing unit for a moment. It should not come on because it gets the control voltage for the contactor from the indoor unit. Check your circuit board for a 3 or 5 amp fuse and make sure it hasnt ... AmcorAire UCHW-H24AF2 Split System Air Conditioner

I have an Amana Model GUC-C 90 Hi-efficiency furnace that we installed in 1992. It has a central air unit as well. On Friday we tried to turn the air on and nothing will work. I have replaced switches in the air unit in the past but this time there is no clicking, I can't turn the circulation fan on for the unit, the heater unit will not turn on. I have power at the breaker, and on the unit itself there is a on/off switch with a round screw in fuse, that fuse is good and I have power there.


Hello,Your control transformer may have quit on you, or your thermostat may have gone out. The transformer is what supplies the current for the hvac system. The thermostat just controls what relays are energized. Since you have a probl ... Air Conditioners

Suburban sf30 rv unit.. I had a new board and limit switch installed. The service tech said it was working. I marked the wires when I removed the unit. I re installed the unit conecting the wires the same as when I removed the unit. I have 2 blue wires, 1yellow and 1 red coming from the furnace. There are 3 thermostat wires 1 grn, 1 wht and 1 red---The power source are 2 solid white wires and 2 blk and wht striped wires, there is power to the unit. I am at a loss as to why it will not work. T


... Dometic Rooftop RV Air Conditioner

I have a model # faa065p7a A/C The power cord burned out with some sparks by the test and reset part. Called frigidaire and they said you could not replace the power cord and had to buy a new unit. This AC is not very old and worked fine. Is this true because I see that power cords are for sale and never heard of the whole unit going bad from the power cord. Did the electronics fry or was I talking to the wrong person? They were not very helpful and just said to buy a new air conditioner.


Hello, i have replaced cords on many window units so yes you can replace the cord. I believe if you go to a online appiliance website they will have the cord you need. I have found this website online with frigidaire parts http://www.repairclinic ... Frigidaire FAC124 wall/Window Air Conditioner

I have a Sharp portable room air conditioner model CV-P10NC. The power plug RESET button and TEST button will not click in order to check out the power plug as the unit will not turn on. They did test O.K. at first but the unit would still not come on. Can the power plug back be taken off to check out the fuse inside - or since it is a type of built in circuit breaker maybe it does not have a fuse inside ? The instruction manual states that " This air conditioner uses a fused power plug". The un


The fused9G.F.C.I.) cord you speak of is probably the G.F.C.I. built onto these units by design, can you or someone you know get access inside the unit and :Hot-Wire" the units cord and,bypass the power cord ( Just To Test the Unit)and see if it stay ... Air Conditioners

I have a Carrier 38tra048340 ac 4 ton unit outside, heater in attic. Thermostat is Totaline P374-1100. Power went out than back on after a few hours due to vehicle crashing into power pole. AC was running at time of power outage. Power came back on, ac would not come back on. Checked house circuit breakers, none tripped off. Turn ac 40amp breaker and heater 20amp breaker off and back on. Voltage ok. Checked fuse box by ac unit on wall, fuses and voltage ok. Went into hot attic to check for powe


Blank screen sounds like a fried thermosat. Abrupt outages can affect certain types of thermostats. Make a jumper wire and jump across R and G. See if you get any action from anywhere. If a fan or compressor kicks in you know you have a burned out th ... Carrier Air Conditioners

Twice now, on my RV heater air unit has turned on in the middle of the night, even though I have the power to the unit turned off. This is a Coleman mach unit with a remote control. If the power is off on the unit, how can it turn itself on?


It obviously does have power going to it, remote controls will not re-energize an appliance such as this. Ensure the switch you are manipulating is the power switch, it sounds like an "on-off" switch and no that is the same thing, a power switch rem ... Coleman Mach III Air Conditioner

Ruud UPNE- 036JBZ 2 years old (outside unit) Ruud Acheiver air handler 1 year old inside unit... outside unit will not come on. voltage (120) ready at contacts. push manually and it comes on. yellow wire and brown wire go to board. no power on these when inside unit is running. power bill has doubled......must be running off heater coils? What would be the next thing to check. I did look at thermostat seems to be working normal. Can't get knowledgeable help.


... Air Conditioners

I have a Carrier Heat Pump model FK4CNF003. I noted that the thermostat wasn't working (no power) so I checked the usual suspects...in bound power etc. before I pulled the top housing off the interior unit. I noted lots of wires on a circuit board in the upper right corner of the unit which seems to route power and signals to/from the thermostat. Looking closely, I noted that the 5 amp fuse was blown so I put in another 5amp fuse and it blew as well. Given the fuse is blown, and I'm assuming


You should be able to trace the short to a specific componant on the board itself. the 5amp fuse protects the board itself. trace the circuitry back from the imput side. you should have a multimeter that has a audio alarm that will tell you which cir ... Air Conditioners

Indoor unit and outdoor unit not running have voltage to indoor and outdoor unit appears the two circut boards not working one is power supply board the other appears to be micro-prosser board checked fuses on power supply board fuses have continutie but have no leds lit on micro board .


Hi\015\012\015\012Please check the bellow links to diagnose your problem…\015\012\015\012http://www.hvac-f ... Air Conditioners

We have a GE-Zoneline AZ38H07DABM2. Since the storms passed though it has not run. I have checked power all the way to the yellow plug inside the unit and it is good. The wall control has power from the unit and I can hear the relay click in it when I plug the unit in. I am unable to even get the fan to run. Looking for any suggestions on where to head next.


... GE Zoneline AZ38H12DAD Split System Air Conditioner

Unit runs but will not cool. Fanruns fine but when turn dial to cool the compressor kicks in for about a second or two the kicks out. Fan works on cool but it will not produce cool air at any temp setting. I have cleaned filter and removed cometic facing and vacuumed the coil face. It was pretty dirty but after all that still would not cool, Unit is installed in a RV and power is provided from house. Gen4erator is also available for power. Unit is difficult to remove from RV and space to get at


You may need to install a hardstart kit if you can get to the compressor.\012go to your nearest appliance parts store to get the part and the instructions are usually on it. If not ask the parts man.\012\012If this was helpful pleas ... Air Conditioners

I have 2 Frigidaire window a/c units, model# fam18eq2a1. The landlord tells me they are brand new. Both units have the same symptoms: about 30% of the time they power on and function normally. The rest of the time nothing happens when you hit the power button. After checking the appliance plug in to make sure is plugged in, I then hit the reset button, afterwhich the digital display lights up completely, beeps, and then usually goes dead, although 1 out of 15 times it will power on and cool f


... Air Conditioners

I have a 2005 Pilgram 27 foot 5th wheel. My Duo Therm AC unit makes a ticking sound from the ac unit itself when it's not running. Shutting off the Duo Therm analog thermostat does not stop the ticking sound coming from the AC unit, nor does cutting the AC breaker (20 amp), nor cutting the ac power to the entire RV. I had to cut disconnect the rv battery AND cut the ac power to the RV before it'd stop ticking. When running however, the ac works beautifully. When it reaches it's intended temp


It's obviously on the 12voltDC circuit of the AC unit. Sounds like thermostat, or a relay in control box is faulty or bad connection. If you remove cover on ceiling assy., you should be able to hear it in the control box. There should be a model numb ... Dometic Rooftop RV Air Conditioner

My outsibe unit somehow fried my breaker i since replaced only for outside unit to not get power again whats the cause of no power getting to outside unit


You need to change where the breaker was, you need to muve it to a different space because the breaker bus bar got fried Find a blank spot to put it in if there is one avalible and check the ground to see if it's ok if it still don't work hire an ele ... Air Conditioners

Haier hsu 18 heat pumps . I have 6 of them , all intermittently come up with e17. otherwise sometimes they will just blow fanned air ( compressor not running ) all day . The power source is fed to the indoor unit first, with the main power and data then fed along the same standard 4 core cable to the outdoor unit. I have fitted one of these units which had this problem to another site , and instead of wiring it as per the above way (as per instructions) I put the data cable seperate to the oth


... Haier Air Conditioners

A detailed question is important to get you a relevant answers