Central air and heat unit heat turns on for 1min and then heat turns on aux. heat


Answers :

All aux. heat comes on when the thermostat calls for more than 2 degrees of the ambient temperature. Once the 2 degree gap is closed, aux. heat drops out of the circuit.
\015\012Some installers wire the thermostat to activate aux. heat every time heat is called for.In this wiring configuration the aux. heat stays on.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Central air and heat unit heat turns on for 1min and then heat turns on aux. heat


All aux. heat comes on when the thermostat calls for more than 2 degrees of the ambient temperature. Once the 2 degree gap is closed, aux. heat drops out of the circuit.\015\012Some installers wire the thermostat to activate aux. heat every tim ... Kenmore Air Conditioners

I have a goodman capf 181A5BA unit which is suppose to be heat and central air but the central is not working how do I turn on the central air part of the unit there is a yellow turn switch on the side of the unit attached to the pipe what is that for.


Did you switch the thermostat to the cooling mode, and turn the temp setting down?\015\012The yellow turn switch? must be a aftermarket addition.\015\012The power must be turned on the the furnace or air handler and also to the outdoor un ... Air Conditioners

Our Carrier central air is unresponsive, nothing at all, no noises, air handler and condenser unit will not turn on, please help me before I lose more weight in my 150 degree attic. The serial # for the air handler is 0695803341 and the product # on AH is FB4ANF030000ACAA / we only have central air, system is not connected to any heat source Early sunday morning I turned the T stat to the off position, when i came home a few hours later I turned it back to the on position and nothing at all, no


I think you need to slow down and start fresh. \0121) You have 115v at Transformer-You are reading from Red to White\012 on windings?\012\0122) If that checked out OK are you reading 24v out of Transformer?\0123) If ... Air Conditioners

Had a ac tech service central heating unit for the fall. Tech left and I left to do some errands . Now AC unit is not cooling its blowing warm air. I turned the circuit brks off and on inside and outside. I have also checked to see if unit was left on heater. thats not the problem. If I turn theAC on the fan does not turn on outside and there is no sound coming from the unit outside HELP!!! AC was working properly before this.


It may not help but it sounds like the tech took a control wire for the cooling circuit loose at the indoor air handler/furnace so that he could bring the heat on to check it, and forgot to hook it back up. That may not be the case, but if it is it w ... Air Conditioners

No heat coming from central air unit when heat is turned on.


Check t stat make sure its set up for you system some stats have to be set up for a heatpump or iits gas or electric heat ... Air Conditioners

I have an old RUUD central AC unit that started blowing hot air. I set the thermostat to off and set the temp gage higher than air temp to turn the unit off and save money, but inside blower unit runs constantly. I'm trying to save money to have it serviced, but noticed my electric bill was higher that last month when the ac was working. The bill was about 4 times higher than the winter when ac is off and the gas heat kicks in. Can the blower running constantly cause this power usage and what is


HelloOkay did you check your thermostat to see if you have the fan switch on auto? The switch must be on auto or the fan will continue to run. If the thermostat fan switch is on auto then there is a malfunction in the thermostat probably ... Air Conditioners

I have a problem with my central heat / air unit. As it is getting cold now, I am using the heat. My problem is that I must turn the thermostat to the on position to get the unit to come on. In the auto mode, nothing happens. I can get very cold but not ever kick on until I move the switch to the on position. In the on position it works fine. Thinking that my problem was with the wall thermostat, I replaced that. I do not remember having this problem with the A/C. What should I look for to fix t


Look on your thermostat one switch (for the fan) will say off/on/auto. The other switch (for operation mode) will say off/ac/heat. The switches should be set at fan auto and mode heat. Some have an auto for the heat/ac if that is the case your thermo ... Air Conditioners

I installed a new Honeywell Programable thermostat, When I turned on the AC it turned on the Heater... I followed the wiring but some of it is not making sense... G=Green, Y=Yellow, R=Red, C=Blue, W2=White, Y2=Brown... The problem is that I have an Orange and Black Wire left over, Which one do I connect to W? and do I have the wiring right... my unit is a central Heat & Air, not a heat pump.


Hi, the problem is you have bought the wrong thermostat for the unit if it is not a heat-pump. A heat pump will have W-1, W-2 for heat strips, and Y-2 is for 2nd stage cooling. G is Green for Fan, R is Red for Power, Y is Yellow for cooling, and W wo ... Goodman Air Conditioners

I have a goodman cpk j42 -1b ac unit on the outside and a central heat and air unit inside. the ac unit come on and runs fine but when it hit the temp the thermastat clicks and the fan outside goes of but the one inside stays running and will not turn off unless i hit the breaker. is it he fan relay at the outside ac unit?


Hello BWOOD Check the thermostat FAN button is in AUTO position not ON position.That might be it .The relay is in the blower unit but they RARELY become frozen/welded stuck on. ... Air Conditioners

My central heater is not blowing hot air, I am having to turn the thermostat on and off. I have the thermostat to 70, and the heater will blow hot air and then it will just circulate the air in the house, therefore bringing the temperature down. I looked at the unit and noticed that when the thermocople (heating element) goes red, the gas valve makes clicking and the flames come and then go out very fast. I noticed lots of clicking in coming from the gas valve. help please


Hi!!! relax your flame sensor is bad change and you will be fine..If it turns off and on change your flame sensor ... Air Conditioners

I have a Ruud UAKA-037JAZ central heat and air unit (Silhouette 11 gas furnace). When I turn the thermostat to heat the heat does not come on. I removed the front panel and there are 2 green lights lit up next to the red pilot light, but the pilot light is not lite. What do I need to do? Thanks


... Ruud UAKA037 Air Conditioner

I have two Friedrich PDE15KSB-C units. When trying to turn on the heat neither will kick into the heat mode. They both blow cold air only. When they are first turned on the air blows, and there is a click sound as though the unit is trying to start the heat pump, but then nothing really happens...just the fan continues to blow cold air. Any help would be appreciated. BTW the dip sticks are all in the positions of 1234 ON, 5678 OFF - factory setting. I did try to turn 7 on for the emergency


Keep +10 degree from your room temp and also thermostat in "heat" . And then check. But in your case, I think RV not energized. If no proper voltage in RV in heat mode, check the wiring to RV. If voltage in means RV not working properly. You have to ... Friedrich PDE15K3SB Portable Air Conditioner

Central heating and air unit is blowing fine in the inside, but nothing turning on the outside, no cool air


Check and see if the fan will turn easily by hand. Do not put your hand inside with the power on. Turn on unit, take a small stick and try to turn the motor. if the motor starts and runs then you capacitor is probably bad. if the motor is hard to tur ... Goodman CLQ36AR49 Air Conditioner

My central heating and air unit is blowing inside but nothing is turning outside; no cool air


The first thing I would check is the breaker/disconnect that feeds your outside unit with electricity. If it seems fine then i would check the electrical contact/relay that energizes the compressor. Low voltage from your thermostat is sent to a sma ... Goodman Air Conditioners

I need help with my central heat and air unit, it has a heat pump. the model number is GQ3RA-036K. I am changing the theromstat out and the wires are connected to it. there are eight wire colors that are orange,light blue,black, red, yellow,brown,green, white. on the new thermostat are letters that are r,w,y,g,l,b,o,e,aux. Which ones go where?


Normal\015\012 0\015\012 \015\012 \015\012 \015\012 \015\012 \015\012 \015\012 MicrosoftInternetExplorer4\015\012 \015\012\015\012\015\012\015\012\015\012\015\012 /* Style Definitions */\015\012 table.MsoNormalTable\015\012\011{mso-style- ... Air Conditioners

My thermostat inside my house will not shut off, runs constantly now, on both a/c and heat cycles. Does the thermostat need to be replaced?I have central air and heat. Recently tried to shut off the heater one morning , had warmed up outside and was too warm in house. I could not get the heater to shut off even manually. finally tried turning on the a/c, it came on but it would not shut off later when it reached temperature set even when I manually tried to shut it off. My outside unit (a/c) is


Hello\015\012IF this is a programable stat.Take the batteries out and replace them.\015\012Then reprogram the stat.\015\012\015\012IF this is not programable have the wiring checked at the unit and the stat.May need to replac ... Air Conditioners

We have a new house and it came with central air. I have turned on the air and turned on the circuits and noticed that the outside fan on the outdoor unit was spinning round (good) now, I checked and the fan is not turning. Turned the unit on and off, still no turning and checkecd the circuit breakers...Any help please. Model is Aire_Flo Outdoor unit AFAIR12B30-A P I hear a low hum to the unit outside. I see trouble here.


First check to be sure the circuit breaker for the outside unit is not tripped. Turn the two pole breaker all the way off all the way off and then back on. If the outside unit still does not run you may have fuses in a disconnect box by the outside ... Air Conditioners

I just bought a 2002 mobile home and it is centraL HEAT AND AIR...My problem is I just turned on the central air, but there is heat still coming from the top part of the wall furnace which is in the small hallway. I have a switch in the laundry room which turns the heat off, but there is still some heat coming from the wall furnace...Do I take the cover off the wall furnace, but not sure what I would be looking for...I use oil for heat.. Thank you very much..


You need to make an adjustment inside the thermostat on the wall. To make the adjustment, lift off the cover from the thermostat and locate the anticipator. If your furnace is running short cycles, the anticipator is probably set on .2 or ... Air Conditioners

I have a Rheem A/C Heat Pump split with gas backup. The gas unit is mounted in the air flow directly before the A/C HP coil. Should the gas unit be wired as stage two heat, or is it OK to wire it as just aux/EM heat? There is no other heating unit. What is the difference between stage two and aux? Please note that the aux gas heat cannot come on if the heat pump is running or it may hurt the heat pump due to the gas heat units location.


Stage 2 is okay as long as there is a fossil-fuel kit accessory wired in the field control wiring. EM heat would only allow gas furnace operation if the thermostat is set for EMER HT mode.......this is not ideal and not recommended. Dual-Fuel applic ... Air Conditioners

I have an Amana Model GUC-C 90 Hi-efficiency furnace that we installed in 1992. It has a central air unit as well. On Friday we tried to turn the air on and nothing will work. I have replaced switches in the air unit in the past but this time there is no clicking, I can't turn the circulation fan on for the unit, the heater unit will not turn on. I have power at the breaker, and on the unit itself there is a on/off switch with a round screw in fuse, that fuse is good and I have power there.


Hello,Your control transformer may have quit on you, or your thermostat may have gone out. The transformer is what supplies the current for the hvac system. The thermostat just controls what relays are energized. Since you have a probl ... Air Conditioners

Details I have a problem with a Goodman Model GSH130601AA, ( 5 Ton, 13 Seer heat pump) central air unit, installed 06/15/2006. (I know, I saw online reviews but unit was put in before I saw negative e


The fan motor is bad and needs replaced. Depending on how mechanically inclined you are, you can replace it yourself fairly easy, the hardest part being the fan blade without a hub puller. Just take your old one in with you to a local A/C supply stor ... Air Conditioners

I have a Lennox model CB19-51-1P air handling unit with HP19-511-1P compressor heat pump unit. I just turned the heat on for the first time this season. And I am getting low heat volume. The heat pump unit is running for long periods. I am getting enough heat to maintain the 70 degrees setting with constant cycles, shutting off for short periods, running long periods. When the thermostat is turned to a cooler temperature, the unit shuts off as it should. Could you please help trouble shoot po


First thing you need to check is if the reversing valve is working you maybe running your A/C with the heat strips on depends on the t-stat your using some heat pumps will bring the strips on with a high d ... Air Conditioners

I have a Frigidaire cooling and heating unit. Last night we had freezing rain and ice. I heard a weird noise coming from the unit then smelled a burning smell. I turned the unit off. The top vent outside was covered in ice blocking air flow. I cleaned off the ice and turned the unit back on and it just makes a humming noise. No air is blowing and I looked inside and the fan is not turning.


Sounds like the motor burned up when the ice blocked the air which it was not able to cool the motor it will need to be replaced. (the motor) ... Air Conditioners

Honeywell central heat & air unit--wall thermostat not controlling it--will not work--thermostat only lights up -aux- and screen goes blank...worked previously...replaced relay and thermostat---still same thing. Why would the thermostat just stop working?


... Honeywell ER150B Air Conditioner

I have a GE Zoneline 5500 PTAC that doesn't throw any heat. The electronic display appears normal during operation, I hear a clicking when the unit is turned on and the fan kicks on but it just blows cold air. The unit was set to the highest heat setting and the air filters were cleaned and unplugging and restarting but still no luck. I haven't tried using the override dip switch to bypass the heat pump, becuase there is a total of 3 of these units in our condo; one in each bedroom and one in th


Hi,\015\012Just for giggles and grins I would switch that one to coll and see if the compressor runs in cooling... that will tell you if it is the compressor or the reversing valve that is bad...It may also jog the reversing valve and get it to ... GE Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1718 seconds