Having problems with your Air Conditioners ?

System works but air is only cool not cold,

\015 I suspect that the system has loss some refregiant . unit is 10 years old. is it possible to recharge the system.\015

Answers :

It is absolutely possible, it will need to be evacuated, and pressurized or traced to locate the leaks. Then, you will have to pull a vacuum on the line and pull a new charge. Hope that helps.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

My toshiba split system will blow cold air for about 30min then it will blow what seems to be cool air but not air con cold air when it is quite hot outside. The timer light operation and filter light will flash. I have turned it on and off reset remote cleaned filters. When it's cooler outside it seems to work fine???


... Fujitsu 9RLS 9000 BTU Split System Air Conditioner

We have a split system model number S24AHP-ND6 its 7.5 kw cooling and 7 kw heating. We have been having problems with it for a while ,it has only been delivering about half the amount of air flow on cooling mode, and now it has stopped delivering cold air altogether and is only blowing uncooled air, also the outside unit seems to have stopped working too.


... Air Conditioners

Window unit comfort aire rad 121 e wont get cool. fan works, everything works, just wont blow cold air. can system be recharged like a car?


Actually it can be charged like a car "if" it has charging ports which it won't have unless someone has installed them - which would only of happened if the unit had a leak previously. So, to answer your question a window unit can be charged like a ... Air Conditioners

My rv duo therm 590 series qquick cool with relay kit 3104998 will not blow cold air both fans are working, suspect system needs recharging.. how do you recharge the system


... Dometic Rooftop RV Air Conditioner

My rv duo therm 590 series qquick cool with relay kit 3104998 will not blow cold air both fans are working, suspect system needs recharging.. how do you recharge the system


... Dometic Rooftop RV Air Conditioner

Mitsubishi I work in a kindergarten and we have two split systems. It worked great to cool us cool in summmer but it's now freezing and we have a large space to heat. The systems are just blowing out cool air, not warm air. Both systems are Mitsubishi's. One is the srk35zgas and the other is msz-ge71va. HELP PLEASE! We're all in our jackets and it's not even winter yet.


... Air Conditioners

System works but air is only cool not cold,


It is absolutely possible, it will need to be evacuated, and pressurized or traced to locate the leaks. Then, you will have to pull a vacuum on the line and pull a new charge. Hope that helps. ... Air Conditioners

My bonaire evap cooling system is blowing warm air instead of cold, the fan appears to be working ok. Any ideas ??


... Air Conditioners

Wont work I have a Maytag central air thats about four years old. Once in a while it would stop blowing really cold air and would just blow mildly cool air. What I would do to fix this is flip the breaker off and then flip it back on again. When I did this the "high cool" light would come back on and everything would work just fine. This time that solution wont work. I have left it off for an hour at a time multiple times. I played with every switch and checked and cleaned every filter. We live


... Maytag M7Y15F2A Air Conditioner

My central cooling system does not work. Every things is working accept a compressor. When I turn on the cooling system the compressor makes strange nose and after one minute it turns off, but fan kips continue to work. Do you have any suggestions for me? Thank you Model # of my air conditioner is CCU10A42A-1


Compressor overload on the compressor ... Air Conditioners

My LG Lan125HV works fine on air conditioning ( cool) but heat pump does not trigger when I move to heat or combined settings. Tried all temperature and fan settings, tried waiting to see if unit waiting so as not to blow cold air, nothing works. Switch back to cooling and everything works fine.


I talked to LG customer support (800) 243-0000. The tech told me that this model had a problem with the indoor thermistor. It doesn't fail with an open-circuit condition, so you don't get an error code. The thermister just goes out of range and be ... LG Heat cool Window Air Conditioner

Air conditioner runs for a few hours and it works - it cools the house. Then it stops cooling - the fan still runs but it doesn't blow out cool air any more. It seems like it's overheating or something. It will blow out cool air if it has not been turned on in a while but once it's on too long it stops. I was told it could be the fan motor and the a/c guy changed the fan motor today but that didn't fix the problem. Now he says it might be the compressor or that I need a new system. I'm jus


The things I would check:\015\012Is the system properly charged with freon? Sytem may be overcharged.\015\012Is the compressor out on internal overload at the point of failure? If the overload isnt tripped and the compressor is having tro ... Air Conditioners

I have a duo-therm brisk air a/c model #57908.521 not putting out cool air. filter is clean, on top i cleaned what i call the rad - there was some dust in the fins but not much. the fan works fin. when a/c is started on high cool the compressor vibrates and runs steady. But no cold air. The air does have some coolness to it but not much. I would appreciate any help or suggestions. Thanks Dennis


Sounds like it is low on freon ... Dometic Air Conditioners

Heating problem hello! My air conditioner stopped to heat. (there is a around 8 degrees C, outside and 16 degrees inside). It worked just fine, and now, when I switched to heating mode, there was nothing. the defrost LED ond the inside unit is switched on, but air is not comming from the unit. Cooling mode works fine. If you could please help me finding the solution for my problem. Thanks in advance. RAdan GE AIR CONDITIONER SPLIT SYSTEM WON'T WORK ON HEAT CYCLE Seems to work ok doing eve


Hi Radan, Did you get this problem solved? We have an Electrolux Kelvinator Split System and ours is doing exactly the same thing. I am struggling to find a solulution. Would be great if you can offer any advice.\015\012\015\012Thanks Nic ... Air Conditioners

I have a fujitsu reverse cycle air conditioner,it wasnt working(not blowing cold air only room temp air like a fan).air con tech came over,re-gassed it,tried air con that day,worked fine.didnt need to use it for a few months,re-tried it,no cool air again,i am thinking of a leak.My question is the air con is about 10 years old,if cause of problem is a leak,is it worthwhile fixing it(i would need to pay someone parts and labour,could not do this job myself),or to just bite the bullet and get a rep


Hi,\015\012\015\012The A.C is 10 years old which is a ideal shelf life for the A.C. If there are any leaks I would never ever try repairing it at home becuase if there is a leak then that means that the entire GAS which helps in the cooli ... Air Conditioners

My Haier wondow air conditioner seems to be blowing cold air but it is not cooling the bedroom. It worked great a few nights ago and made the room really cold but now its not cooling.


A few basic principles for air conditioner troubleshooting. For both central home air conditioner or window air conditioner,\015\012 the first thing to check is whether the unit is getting proper power. \015\012If the unit ... Haier Air Conditioner

Don't panic, but I have a question about my 40 year old duo therm RV roof top AC. I know, it shouldn't be working, but it does. My problem is it will kick on, compressor starts to work and puts out cold air, then I hear the relay kicking out and it stops putting out cold air. This past fall I took the shroud off and cleaned everything and observed the operating system. Again, it starts, runs for a minute or so, than the relay opens. If I push on the relay, it will run again. A friend suggested a


When you say relay I'm assuming the contactor. Does it shut off again when you let go of the contacts (relay)? Most likely it's low on refrigerant and the low pressure switch is shutting it down. ... Dometic Rooftop RV Air Conditioner

Warm Air My Fleetwood motorhome Dash air is giving me problems. After I turn on the controls Blower, outlet position, AC on button and re circulate button I may or may not get cold air. After continually operating the controls mainly blower & AC button, I can some times get the AC to cool down. When it is warm it's about 80 degrees, when I do get it to start cooling it will go down to about 60, Checked with an IR thermometer at the vent. Once it does cool down it may work the remainder of the d


... Air Conditioners

I have a Danby DPAC10030 air conditioner. It was working fine until yesterday, when we moved it to another room. Now it blows cold air for 5 minutes and then the air turns hot. The a/c motor continues to run even though the air is no longer blowing cold air. The current ambient temperature is 25 degrees C and I have the a/c set to cool to 17 degrees C. The timer has been turned off (0:00 on and 0:00 off). I noticed that the hoses (exhaust) feel quite hot. Not sure if that it normal within


Clean you filter and clean the area under the intake duck it will solve your problem ... Air Conditioners

I have a frigidare FAM157S1A Air Conditioner, when plugged in the fan blows air but not cold air. Compressor not working, I pushed control panel to cool air, blows cold air for a few seconds, then unit blows the breaker. How do I fix it. It has been only used for two weeks and this started.


Your compressor motor is no good Time to replace unit ... Frigidaire FAH085N1T Air Conditioner

We are selling our house and have been leaving the air conditioner on for the last several days at 70. It has been keeping the house cool for visitors when we are at work. Yesterday I came home from work and the house was warm. I checked the air conditioner and it felt like it was blowing just air. Checked it throughout the night and still blowing just air, not cold anymore. I am thinking it ran out of coolant. I am not an expert or know anything about air conditioners. If you could give me your


It can be many things like a loose connection. It can be low of refrigerant or it can be the condenser fan has stopped working. Considering you are selling the house just call a qualified HVAC repairman and have it repaired. ... Air Conditioners

My carrier A/C YHB243D this window unit was working find. But about one week ago only blows out cold air and sometimes only hot air but now it blows only regular air, and doesn't work nither the cool or heat air. what could be wrong with it?_a) could be- the thermostate that goest at it front with its condenser unit? b) could be the whole temperature switch ? or what else can be its problem, please help! and tell me where I can get the replacement part


... Carrier Air Conditioners

Central air system blows cool air not cold and


Your indoor unit is only circulating the air in the house. for your condensing unit. check your breaker in the electric panel. your contactor or your capacitor. ... Carrier Air Conditioners

I have a suburban lp furnace and duotherm air/heat pump roof unit. duothern thermostat. 20 amp breaker kicked ( reset breaker) & furnace quit. NOW furnace fan comes on but does not light, and the front AC will not work either, when in the COOL position on STAT the unit blows warm air instead of cold. I replaced the Thermostat and a Tech guy checked the board in the furnace and it was OK. He also switched the board from the rear air with the front and nothing changed. Rear air and heat pump works


I'm not sure what the problem may be but you could try calling All\015\012Seasons RV Appliance Parts & Service. There number is\015\0121-800-344-0673 they have helped me in the past. That and there tech\015\012calls are free so it wouldn't hurt ... Dometic Rooftop RV Air Conditioner

Hi,I am really hoping to find someone to help me if possible. I have a one year old carrier infinity 4ton 17seer condenser and a 5ton variable speed air handler. I has worked fine but now i am getting a SYSTEM MALFUNCTION on the thermistat. When this message appears the air handler continues to blow and only the fan on the condenser continues to run but NOT the compressor so it is not cooling. At times it begins cooling again but then later stops cooling and shows the same malfunstion message. I


Hi,\015\012If this si what I am thinking it is, it will be very hard to find and prove.... \015\012The compressor windings have aflat spot and if the motor stops at the right place it will not atart. The voltage goes way up and kicks out ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1546 seconds