Having problems with your Air Conditioners ?

My (Rheem)electrical heater is not heating the

\015 My (Rheem)electrical furnace is not heating the house. The blower will come on but that is all.\015

Answers :

Check all your manual reset limits. There are two wires that go to a small disk about the size of a penny. In between those wires is a small button. Press the button firmly. You will have between 2 to 5 of these. There is also a limit switch located on the back wall of the unit that enters in the heat exchanger but it is not resetable that could be bad. You will need to check all of these. They can be jumped temporarily by removing the wires and adding a small wire.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

The dealer is changing the heater core because there is no heat coming from the drivers side. The center and passenger vents have good warm air coming from them. How can a heater core be the problem if you get heat out of one side and not the other. Is this a two section heater core. We are talking about alot of money to replace the core.


Don't know what make and model vehicle you have. But, I'd suspect a loose vent hose to the outlets that have no heat. Or the blend door is stuck in the wrong position. Can you get hot air to the defroster, when you turn the control knob to defrost? ... Air Conditioners

Over the summer we shut our thermostats off so that our furnace would not turn on since the weather was beautiful. But we noticed that our heaters in our downstairs part of our house were warm. The furnace did not sound like it was on, but for some reason, the heaters were emitting heat. In order to stop this, we had to manually shut off the valves on the furnace. This stopped the heat from coming out of the heaters. But now that it is fall, I have the thermostats on and even when the tempera


Do you have a water heating system? ... Air Conditioners

Hydronic Electric Baseboard Heater - PLF2004D - 90 in 240 Volts / 2000 Watts / 8.3 Apps Yes, using 240 volts Just purchased hydronic heater (Marley/Fahrenheit). Everything is good, except 1 major problem......it 'pops' The heat keeps 'popping' on and off every few seconds. Seems likes it 'pops' when obtaining heat and then stops 'popping' once at temperature. This is the 2nd time after replacing formal, thinking it was a one time problem. This is in my bedroom and is flat on the fl


Hi!!\015\012\015\012Make sure there is 240v present, there are some safety devices installed that prevent unit form working if there is a problem. In this case, I believe being on the floor and not properly installed is causing the the heater ... Air Conditioners

Twice the heat went out LG 18000 5 year warranty. 1st time unit sparked inside the unit, Tech came out couldn't repair was given a new unit (2 weeks out of service) had to buy 2 floor heaters at a cost 125.00 as temporary measure. 2nd time out was a year later. (used twice for heat) Waited for tech 1 day called to cancel that day for the next day and would be at house between 6 - 8pm. Never showed called at 7:30pm and asked me some questioned. Tech ordered updated heater core. He state


Was the first unit a different model ? what the repairman said is pretty much right but they should be more ontime and communicate if they want a good name. the unit should work fine after replacing if it doesn't dont pay for the part ... LG LWHD1807HR Thru-Wall/Window Air Conditioner

Cycleing, ok it sound like the heater fan kicks on then off , on then off, on then off, just like that . it will do this on heat cold or in off post. the ac and heat seam to work but i dont get the on off cycleing ! its not the ac blower but like a fent fan for the heater ! had a ac tech tell me it may be my main bord! carrier modle # 58RA (VJU one of these is next not sure witch)050 board # HK42FZ009 S/N 3197A13382


You are referring to the inducer motor that is kicking on and off. It is probably a limit switch that might be triggering it to go off and on over and over. It could possibly be the board but I highly doubt it since the ac works just fine. It can ... Carrier Air Conditioners

Do you still make the heating element for the 707 heater, it is a very small heater that is used to heat my bath room. It has lasted for years


Www.bizrate.com have replacment heating elements still available :)best of luckplease remember to rank my reply ... Air Conditioners

I have a Goodman gks90703bxae gas heater. When I turn it on it runs fine heats the house the blower shuts off but then the induced draft blower stays on so the heater will not heat the next time it is supposed to I checked the flue and the drains and they are fine and it throws a code that says I need a new pressure switch but it also says that my induced blower should not be running and it is can't figure it out hope you can help thanks


Hi!!\015\012\015\012The ID Blower pressure switch may be stuck closed, and keeps the ID blower running. Replace the switch. Click on the following link for a Parts Manual for your unit to Identify the part # and order it.\015\012 ... Goodman Air Conditioners

In February 2009 I had an Amana 16 SEER heat pump airconditioner & heater installed. It replaced a Frazier Johnston which had an after-market UV light installed on it. When the dealer installed the Amana I asked if they could transfer over the UV light to the new unit, which they did. Within weeks of the installation of the new unit it started to emit an obnoxious smell of something burning everytime the heater would run. You could not stand to be in the house during or after the heat had ru


This is a common problem with residential installations. The UV light is most likely installed in the wrong spot. At the risk of sounding skeptical you could replace the UV unit with an electrostatic trap system. There are some other considerations: ... Goodman CLQ36AR49 Air Conditioner

I have a dimplex panel heater evx 200. The heating element is brokrn due to something being pushed into the vents. Power is still going into the heater but no heat. can it be repaired/element replaced?


... Air Conditioners

My heat a-lot heater will turn up to 84 degrees and still never turn on the heat. Its seems like the thermostat on the heater isn't reading the right temps. How do I change the temps?


... Air Conditioners

I have a Carrier Debonair 250 thermostat runs my AC and heater made by Carrier. it continues to run past the SET heat setting of 68. One day we were not home it continued to run until 99 when we stopped it and temperature was set to 68. When I leave it in AUTO mode (heat 68 and cool 70) it will run both heater and fan/ac continuously without any interruption. It did this for more than 4 days. Since then we are manually operating this. Is this my Thermostat that is bad or my system is bad. Please


Hi,\015\012The heat relay in your thermostat is hanging up.. then the heater overshoots and the thermostat turns on the A/C also...then you have them both running at the same time... right??\015\012Replace your thermostat and you will be ... Carrier Air Conditioners

Heater not working. have power going to heating element. I,m guessing there's a heater inside of the roof air conditioner because it has a heat or cool on control panel. I belive the number of unit is QC 135 029193 0000 made by Dometic care. My RV was made in 85 made by EZ Rider. Thanks Paul


It may be capable of running heat element, but may not have been installed. Remove ceiling cover and you should see an element sometimes shaped similar to a light bulb, or maybe just a straight rod style, but it should be fairly obvious and be sticki ... Dometic Rooftop RV Air Conditioner

My thermostat inside my house will not shut off, runs constantly now, on both a/c and heat cycles. Does the thermostat need to be replaced?I have central air and heat. Recently tried to shut off the heater one morning , had warmed up outside and was too warm in house. I could not get the heater to shut off even manually. finally tried turning on the a/c, it came on but it would not shut off later when it reached temperature set even when I manually tried to shut it off. My outside unit (a/c) is


Hello\015\012IF this is a programable stat.Take the batteries out and replace them.\015\012Then reprogram the stat.\015\012\015\012IF this is not programable have the wiring checked at the unit and the stat.May need to replac ... Air Conditioners

I paid $20 last night to talk to someone. He told me how to hook up the Lux DMH110 but when i hooked it up this morning the heater came on when i put it on COOL and the fan just come on when i put it on HEAT...when its on HEAT the A/C or the heater does not run. Please help I don't have another $20 to spend...


If you have this type of system your thermostat will not work;\015\012Multi-Stage Heat Pumps \015\0123 Wire Hydronic Systems \015\012Line Voltage Systems (120/240 VAC) \015\012\015\0 ... Air Conditioners

THE PILOT LIGHT "LIGHTS" NORMALLY AND THE HEATER LIGHTS NORMALLY,BUT WHEN THE ROOM TEMP HEATS THE HEATER GOES OFF THE PILOT GOES OFF AT THE SAME TIME.SO IT HAS TO BE RELIT EVERY TIME I WANT HEAT.


This sounds like a bad thermostat, or thermocouple, or possibly both. I'm not sure which is bad, or if both are, but if you will respond with the make and model number, I will research this problem later, since I have to get to work now.\015\ ... Air Conditioners

We have a old house and the gas hot water heater and the central heating unit is vented out an old chimney and the heater is building up condinsation, how do i vent the heating unit out the wall, unstead of the chimney.


A CHIMNEY Liner is your best and cheapest solution to your problem,as furnaces and hot water tanks have gotten much more efficient over the years,a lot less heat actually goes up the chimney to help remove the contaminants,up the flue ,depending ... Air Conditioners

I have a goodman A49-20 electric heat it recently quit heating and I pull the front off the heater. One red wire off a leg of the 60 amp breaker was burnt that was going to the upper heating element. I replaced it and it still is not heating. The two heating element plates have alot of surface rust on the plates looks like. Any ideas thanks.


Electric heaters have safety thermostats and possible one has tripped. Also find out why the wire shorted in the first place. ... Goodman CKL49AR49 Air Conditioner

Hi, I have just had a Dimplex XL 24 nightstore heater installed. My wife is concerned that the heater is fixed in direct contact with the wall (painted plaster) via the wall fixing bracket supplied. Our old heater had a strip of sheet metal fixed against the wall behind the heater to protect the wall from the heat. Is not having sheet metal protection a fire hazard?


YES it MUST have a meta backing to conform with the CODE. It's NOT so much the heat from the unit, it is in case of a fire INSIDE the unit, as anything that has electricity can have this happen, well the metal backing at least gives some protection f ... Air Conditioners

Have a Vulcan MZ85 Gas Heater with a Vulcan Programable Thermostat T8602C originally hooked up in heat and cool system with one transformer the cooling system has since been removed and now operates the heating unit. The issue now is that you turn the thermostat on to heat it will heat up to the pre selected temperature once it reaches that temp it turn itself off it does not maintain the set temperature so you have to turn the unit off and restart to activate it have tried 2 other thermostats w


Hi, you need to wire the thermostat like this. You now have no cooling, so remove the jumper wire from RC and leave it on RH. Remove the yellow wire also. Make sure it is wired the same way at the furnace terminals also. Sounds as though you have 24 ... Air Conditioners

I have an Intertherm electric furnace in my mobile home model # FEHB 015A. The heater started acting up by first blowing warm air like normal but then blowing cool, not heated air after a few minutes of operation. At some point it seemed when it was blowing heated air that it was really hot, then cool. Then it just quit heating the air at all. I am looking for a schematic to identify the heating coil or igniter coil if it has one for possible replacement.


Http://www.nordyne.com/Literature/707716c.pdf\015\012\015\012\015\012\015\012http://www.nordyne.com/Literature/359a.pdf\015\012\015\012The diagrams above may not be exactly what you are needing. But they will be close. Usually the diag ... Air Conditioners

Vulcan Comfort Control Central Heating unit - Our heater is situated outside and is ducted under the floor and operated by a remote control. When we activate the remote we can hear the unit starting up and have also witnessed the glow of the pilot light starting but the heater fails to start. I have had the technican three times and they cannot diagnose a problem - we have no heater at present - please help


... Air Conditioners

I am installing a 240v heater in my downstairs bathroom. The heater schematic has a single BLACK 240v live input wire and a WHITE 240v neutral output wire, plus a yellow/green stripe ground wire. I have run a 12/2 cable(red/black/cpr gnd)from a 2pole 30Amp breaker in the breaker box to the heater. I have connected black to black; gnd to gnd; and red to white. I get no heat but the fan runs. Do i need a 12/3 cable(red/wht/blk) and couple the red/blk to the blk wire and wht to wht neutral, or can


You dont need all that wht is 120vt blk is 120vt thats your 240 their is no neatral on 240 volt ont a 120 volt circuit it sounds like it is wired correctly you may have a wire not getting good conection ... Air Conditioners

I have Amtrol water heater. Recently I noticed that boiler trying to start several times till it finally starts. I decided to check if it is a boiler or water heater problem and turned on house heating system that was OFF for summer time. Boiler started immediately without any trying atemptes. Looks like it is a water heater problem. My qustion is: what should I change most likely - temp. sensor or temp.control? Thank you. Vlad


That's a good question. What a shop would do, is try one, then, if that didn't work, try the other, in this case- if they had the parts. It's hard to test the sensor correctly, and the temp. control might be intermittent, which means it would sh ... Air Conditioners

Not heating I have a Intertherm. the heater does not turn on, I can get the fan and every thing to turn on but not the heating coil. the heating coil starts but then shuts off before the fan kicks on.


1st you said the fan runs..but partial info so best guess it fan limit contor bad. ... Intertherm P3RA-048K Air Conditioner

A Nordyne air handler, model B3BV-030K, with 4 wire thermostat. Thermostat and AC works fine in "cool". Switch it to "heat" and nothing happens.No fan, no heat.(I have built in heat strips -resistors). I jumpered (on the nordyne circuit board-input from thermostat) from R to W. (24 volts from R to W, which should start the heater. Nothing. No relay "click" like when AC comes on. If i jumper R to Y, AC comes on ok. Does this sound like a relay gone bad on the circuit board? Or what? If relay bad,


Do you get heat when you jumper R, G & W? ... Ruud Central System Air Conditioner