I have a intertherm gas furance that won't ignite. the pilot light is on. the fan will come on about every 10 minutes.


Answers :

It is probably one of the limit switches that need to be reset. There will be two wires that lead to a small disk about the size of a penny. In between those two wires is a small button. Press this button. Sometimes they can be stiff and you will need to press firmly. You could have as little as two but as many as 4 or 5. If the limit keeps tripping, then you will need to replace it unless the unit is getting too hot in that area.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a intertherm gas furance that won't ignite. the pilot light is on. the fan will come on about every 10 minutes.


It is probably one of the limit switches that need to be reset. There will be two wires that lead to a small disk about the size of a penny. In between those two wires is a small button. Press this button. Sometimes they can be stiff and you will ... Air Conditioners

RUUD heater The heater will run for about 20 to 30 minutes then it will cycle on and off. The igniter lights every time. It turns on the gas but only stays on for about 5 seconds then shuts off. The fan comes on for about 2 minutes then the cycle starts all over again.


Sounds like a dirty flame sense rod. Be sure to shut off power before removing the rod and cleaning it with sandpaper or steel wool. Do not touch or disturb the hot surface ignitor or you may cause it to fail. ... Air Conditioners

Our furnace went into lock out and so I cycled powere and it reset it started working again but not correctly. The inducer motor wis coming on for a few minutes then the hot ignition comes on and the gas lights. then the blower comes on then shortly after the gas cycles off and then a few minutes later it cycles back on and usually the fan alternates on with the gas. I started checking the safety switches that go to hot ignition control. (24V) Once everything was running the 24V would drop to ze


Boy it sounds like a high limit opening up and shutting off the gas valve. It won't shut off the blower because it wants to cool off thge furnace. Check for any restriction in the air delivery system, filter, registers. Check for blockage of the exha ... Air Conditioners

Make = Trident exel natural flame gas fire - model fan powered rear flue - 549 RMN FEF +3 The fire ignites and runs normally for about 10 minutes and then the gas side completely cuts out (both the pilot and the main jets). everything else keeps running (lights and fan). Re-starting the fire results in about 2 mins before it cuts out as above, this then repeats no matter how often its re-started. Electricity is fine and gas supply appears to be smooth and fine (Gas central heating / cooker a


Hi this is a oxy pilot problem as you say, would be best to replace. There are two types that were used on Trident /FEF fires,Ican help with either but need to know which one ,get back to me for further help .Will. ... Air Conditioners

We have model # 58SXA080-JG Gas Furnace-the fan is not turning on-heat is not coming thru the vents. We had the control unit/circuit board replaced yesterday. The fan, pilot light and heat came thru the vents for a few minutes-then stopped. Can't get it to come back on..Trying to find what else it could be


Blower Control Circuit Board (Carrier, Payne, Bryant) is the faulty partInput Control Voltage: 18-30 VAC.\015\012Frequency: 50/60 Hz.\015\012Power Consumption: 5 watts max.\015\012Output Ratings:-on high contact: 20 amps resistive @ ... Carrier XHB123D X/Y Series Heat/Cool Air Conditioner

Furnace is getting gas but pilot will not light it a bryant ego series,tried reset button it kick on the other fan,but thats it blows cold air,need some help ,my sister and her lil girl need heat,and she doesn't have the money for a professional to come out,and she miles away from us .she has one rail with five cones,gas comes out but will not ignite.


Is this a standing pilot or electronic ... Bryant Air Conditioners

Gas furnance would only operate for about 3-5 minutes then turn off. Replaced gas valve on furance for a Rudd comerical A/C 4 ton unit model UKKA-A048JK10E. Now the blower fan turns on but the igniator and gas does not come on as before. LED light (flashes 5 times) on board indicates flame roll out switch is open. Need manual to locate roll out switch, does it have a reset button or does it need to be replaced?


The rollout switches will be located at the ends of the burner assembly and will have a manual reset. they must be manually reset to ensure that the problem has been corrected. Most units will go into a soft lockout for a time and eventually a hard l ... Ruud UAKA042 Air Conditioner

I have a Rheem furnace rglh-10nbrjr that motor runs but flame does not light. If I turn up thermostat, the fan comes on and I hear a click after 10 or 15 seconds. I see no spark or anything from electronic ignition. Actually, do smell gas after running fan for a few minutes. Any idea what the problem could be?


Hi, you shouldn't smell any gas until the pilot flame is etablished. The sequence of operation is the small inducer motor will start on a call for heat, Then on the motor you should have a poly type tube, clear, that runs over to a pressure switch. I ... Air Conditioners

I HAVE A RUUD SILHOUETTE GAS FURNANCE. The pilot light keeps blowing out. When I light the pilot flame it seems to work perfectly at ignition. As the Manual instructs, I hold down the ignition switch for 30-60secs to keep the flame lit and then turn the gas switch to the on position. After watching the unit I have noted this happening - the furnance will begin the heat cycle sequence and pilot litghs all 4 burners correctly, the blower fan turns on, Heating starts. But after a short period, the


Short answer, yes. However you could have another problem. Replace the thermocouple that keeps the pilot lit. You can get a universal one at any good hardware or farm store. Make sure the new thermocouple is well into the pilot flame. If the blower ... Ruud UBHC Air Conditioner

Hi , I have a Electronic pilot lighting system on my RUUD package unit. The pilot light flame keeps blowing out or is not working properly. I removed the panel to look and see what was wrong. I could not see any faults. The sparker worked just fine, the gas line tubing was fine no blockages( took it off to inspect it) every thing looked good. Worked fine for the last couple of weeks and now it will not ignite the pilot light to light the rest of the propane gas to heat the house. I tested the fl


Sounds like you have checked most things. A pilot will go out if it is dirty, if the gas valve is not holding or if the senser is dirty or bad. Remove the pilot and clean out the small orifice inside. Check all electrical connections, clean the senso ... Ruud UBHC Air Conditioner

Rheem gas furnace pilot lights, but no burners or fan


If the burners do not fully ignite, the sensor will shut the furnace down. The lack of sufficient burner flame is a gas valve or gas pressure problem within the valve. Replacing the gas valve with the original one may get you going. I surely su ... Air Conditioners

I am trying to find information on re-lighting my pilot light on my honeywell day and night furnace. I see switch for blower is off, pilot dial is on "pilot". Blowers not active and pilot light not lit. I think I just need to turn pilot dial to off to reset and leave for 5 minutes and turn back to "pilot" and re-light, before turning everything back on. I'm not sure where the gas is coming out of. Is it right above the dial. I have long matches to use. Please let me know. Thanks for you


Without knowing exactly who the manufacturer is and the model number of the furnace, most of us really don't want to reply to this question, for fear of you blowing yourself up. So, if you can provide that information, I'm sure one us can help you. ... Air Conditioners

RUDD Silhoette 2 model UGLH-10EBRJR ignitor won't ignite (glow). Exhaust fan comes on for about 30 sec. then the thing clicks, a small amount of gas emits then turns off, then the circulating fan comes in and runs cold for a while. I can light it manually 9with a lighter) and it runs OK until the house reaches temp but then, of course, it won't come back on unless I light it manually.


... Air Conditioners

I have a sv9500m 2674 tha has a sticker that says it has been converted to L P gas. The ignitor lights the pilot and the fan comes on. The pilot stays lit and the main furnace fan comes on but the burner never fires. I have checked the electrical connections, cleaned the flame sensor that is on the ignitor (Q3400A1024) and cleaned the orafaces on the burner. I am thinking that the valve may be bad because the main furnace fan does activate which I assume is also controlled by the flame senso


Hello,If you cleaned the flame sensor and it is in the pilot flame,Try adding a ground wire from the pilot assembly to any close screw to boost the (pilot on) signal.Also if the valve has been sitting for a while give a tap once during (pilot on) to ... Honeywell Air Conditioners

Gas heat does not always come on when it is switched on, when it does it works fine when it does not, the house is filled with a bad smell, I'm assuming unused gas. we have had the burners scrubbed with a wire brush before and no problems for 2 years. Can the burners just be replaced? Pilot light works fine. The furnace tries to come on, i can hear it clicking to ignite. Thanks Ronnie from Atlanta


You need to check gas vent ASAP. You should not be getting any odors from your furnace. Have a technician check your furnace. Could have hole in Heat exchanger. If so you and anyone else there are in danger. Please do not operate till it has been che ... Air Conditioners

Compressor problem? My outdoor unit comes on with the fan blowing just fine. Then I hear a buzzing sound for about 2-3 seconds which I believe is the compressor trying to come on. (Incidentally, a couple of lights inside the house seem to dim at the same time that the buzzing sound occurs.) The buzzing sound reoccurs every couple minutes while the outdoor unit fan and the indoor blower both continue to run. I have shut down both the outdoor and indoor units for a couple hours and tried restarti


The buzzing is your compressor trying to start. It is going off on internal overload caused by heating up of the motor windings.If you have an amp meter you could check the amp draw of the comp against the locked rotor amps listed on the tag You cou ... Ruud UBHC Air Conditioner

I have a 1985 Bryant central air Furnace model 395BAW048095 with a White Rogers 36E gas valve. The flue is metal and there is a fan within the furnace to create a vacume at the base of the flue pipe conection that turns on when a call for heat comes from the thermostat at startup to ignition. The spark fires but no gas is released by the valve for the pilot to lite. Added information: The blower fan is set to continually run, I replaced the pressure switch (306621) and the limit switch (HH12ZB18


... Air Conditioners

IT'S A WATER HEATER NOT AN A/C Richmond Power Vent model 6640PV-40 Manufactured 06/07 This unit does NOT have the digital or other hi tech read outs or flashing lights, etc. Control unit is round red dial type, on demand spark ignited pilot. Unit will not light. When switched on, fan activates but the spark unit does not fire. Fan cycles off after 15-20 seconds. Actions taken: Have unplugged unit from AC and allowed to "rest" for 1 minute, plugged in and tried. No result. Checked all el


Thermocouple keeps the pilot light lit\015\012A thermocouple produces a small electric current \015\012that tells the gas control valve that the pilot light is burning. If the \015\012pilot light goes out, the thermocouple stops producing the electri ... Air Conditioners

I have an intertherm model number G5RA096C-16 furnace. The igniter stays lit and the gas doesn't come on. The status light blinks twice. Help?


... Air Conditioners

I have a Charmglow patio heater. I have taken it apart and cleaned all openings where the gas comes out, but the flame still goes out after 7-8 minutes. It lights fine but will not stay lit for more than about 7-8 minuites. I have also replaced the butane tank. If I wait awhile I can re-light but if I try and do it right away then the pilot lights then I turn the knob and the flem lights but if I let go of the knob it burns out.


From what you have described, it sounds like the Thermocouple is going bad and needs to be replaced. As far as not being able to relight the pilot right away is concerned ... that's a safety feature. The control has to reset itself, before you can re ... Air Conditioners

A 2 month old Goodman GMH95 natural gas furnace has been working properly until tonight. Now it starts up properly, but after 30 seconds (and right when the cirulator fan kicks on) it shuts the gas valve stopping the flame. LED light flashes 8 times, which is not an option on the trouble shooting guide. Unit will retry every few minutes and cycles this way over and over. It appears the control module is not receiving the gas flame detection signal. What do we need to do?


Goodman's control boards are very sensitive as well as the connections to the gas valves. Check the wires and make sure they are snug and tight. With it being only 2 months old, I doubt the board is bad or the flame sensor(unless it is a used syste ... Air Conditioners

We have a Intertherm MAC 1378 gas furnace in out mobile home and it has shut off on us. There is still gas coming in, we checked the meter outside to be sure. But when we try to reignite the pilot light it wont ingnite. We can't smell any gas when we try. We've followed the instructions on the furnace on how to reignite it and it still wont work. It's well below frezing with a **** load of snow we have 2 kids, one of which is a newborn and its getting really cold. So anything you can tell us wil


Check to make sure the roof vent is not covered over with snow.\015\012Very deep snow can block the intake to the furnace. You may need a ladder and a broom (or shovel) to clear the snow.\015\012Hope this helps.\015\012Matt ... Air Conditioners

Brivis Wombat 92 heating unit - I am having trouble getting the pilot light to stay lit. The gas is on, the igniter is sparking and the pilot light ignites but when I gently release the red gas valve after 60 seconds as prescribed in instructions the pilot light flame extinguishes itself. Have tried venting the gas line to get rid of oxygen and this isn't helping. Any ideas?


Hear of a PRIMUS pricker?This is a very stiff but fine wire that was used to clear the jet on an old primus stove. The gas jet head at the pilot has a fine hole to allow gas to flow. When you hold it open with the button it allows for the ... Air Conditioners

I have a Trane gas furnace BLU080E, pilot light remain on set the thermostat above room temperature fan start runing after few minutes but main burners remain off and have 24 volt on gas valve.


Almost a classic sign of a bad gas valve. pilot is lit so gas is available. FAN COMES ON AND 24 VOLTS TO gas valve so there is a call for heat . gas valve doesn't open so it looks like its bad. ... Air Conditioners

I have an older Carrier Gas Furnace. I can't read the complete Model number. But since Thursday morning, the blower just keeps blowing cold air, the spark igniter won't spark and the air damper will not open. I replaced the spark igniter and the pilot assembly for $215 and the thing still just won't light. As soon as you turn on the power the blower comes on and just runs. I check my 24v supplies from the transformer, and I am getting voltage. What else could it be. There are no LED's on the PCB


Nothing will happen until the draft motor come on or the vent damper opens.  if that's happening, are you getting gas? ... Air Conditioners

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific
all rights reserved to the respective owners || www.ad-trader.net || Terms of Use || Contact || Privacy Policy
Load time: 0.1109 seconds