Having problems with your Air Conditioners ?

I have a mobile home and the, unit in the house is freezing over , what could be the cause?


Answers :

Lack of airflow over the coils, dirty coils, and low refrigerant. Those are the only things that cause a unit to freeze up. So check your filter and replace it if you haven't already, make sure the coil is clean and have a professional come and check the charge. Don't forget that this is the time of year that the outside unit should be washed as well.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a mobile home and the, unit in the house is freezing over , what could be the cause?


Lack of airflow over the coils, dirty coils, and low refrigerant. Those are the only things that cause a unit to freeze up. So check your filter and replace it if you haven't already, make sure the coil is clean and have a professional come and che ... Air Conditioners

Model ck42-1a compressor won't come on. I replaced the intake filter about a month ago. It was a pleated filter and was real caked when I replaced this month. Can that cause the compressor to go out? I have two units and the pipe coming in to the house is cold on the good unit but not on the bad. Could that be anything but the compressor? Low freon or a-coil freezing in the house?


The fact the filter was very dirty and the door partly open allowing non filtered air to enter the system leads me to a possible dirty evaporative coil on the furnace. That can cause poor airflow and iced up coil reducing airflow even more. In the lo ... Goodman CKL42AR42 Air Conditioner

I have a Coleman Central Air Conditioner/Heat Pump. On the cooling mode the coils inside the unit in the basement continue to freeze up causing no air flow. I relpaced the filter thinking it might have been restricting the flow causing the freezeup but it still freezes up. What are the suggestions on what could be wrong with my unit


The most common reason for freezing up is 'air flow,' and since you've already changed your filter - have you checked out the coil (the one that cold air comes from) to see if it's clean? If the filter you changed was really 'bad dirty' then it's a ... Air Conditioners

My AC unit keeps freezing up on the copper lines going into the house from the outside unit. It also freezes up on the inside lines and the air is not cooling my home down.


Operate your air conditioner with the fan in the on position. But first turn the fan on, turn the temp up or shut the cooling off. Your coil is more than likely frozen over. At night when outside temperature drops the refrigerant pressure and temper ... Air Conditioners

We recently replaced an old window unit with a westpointe a/c mwk-08 unit. The old unit was dripping water in the house but the new unit doesn't seem to be dripping any water? Could this possible be a drip "less" unit or is it installed incorrectly? I've heard the horror stories about mold building up in window units & causing MAJOR health issues.


If the old unit was dripping condensate into the house, it was installed incorrectly. The replacement unit may have been installed correctly so the condensate drains outside. ... Air Conditioners

I've just moved into a home with an existing Armstrong Concept 10 A/C unit that's at least 15 years old. When I left for a 2-week vacation, the unit was working great. I set the thermostat to 77 to save energy. Upon returning, I lowered the thermostat to 70 and waited, and waited and waited several hours only to find the temp. in the house was not lowering, it was actually rising! I could see the unit's fan blade was not moving so I checked the circuit box in the basement, and the A/C breaker


Hello 93 The compressor caused the breaker to trip.A weak capasitor or burnt wire is a common cause.It sounds like the compressor is NOT on even though the fan is.It may need a new wire or maybe a HARD START kit to help restore operation.Call for hel ... Air Conditioners

I have a weil-mclain boiler.i came home the last 2 days and temp in house was 76degrees house is set for 68.i have a honeywell L8148A1017 Aquastat relay could this be causing my boiler to somehow keep firing when none of the thermostats are actually calling for heat. thanks Paul


Yes, possibly a faulty relay ... Honeywell Air Conditioners

My Mitsibishi Mr Slim freezes. The unit is clean and there is enough freon what could cause the freeze?


... Air Conditioners

I have a 5yo Inertherm Unit in my mobile home, and the Heat unit will not come on. I hear the click in the thermostat, and no signs of burned wiring, but no heat. Was working and just stopped blowing. Could this be in the Capacitor?


Are the filters clean? Is the evap (indoor coil) clean?\015\012\015\012If not it will cause a lack of airflow. A lack of air flow can allow the heat stripos to get to hot, causing the temperature limit switch to trip off.\015\012 ... Air Conditioners

I have three window ACs in my entire mobile home(double wide). One at the back of the house, one in the middle and one in the front. Each one is plugged into its own outlet. If I try to run more than one AC at a time the breaker pops. They seem to all be on one breaker as well as several other items in the house(ceiling fans, alarm clocks, etc..). The breaker has a 30 on it and the AC's Im not sure what they use but the AC units say to use a 15 amp. What can I do to fix it and can I do it myself


Usually when I install a window A\\C I prefer to run a dedicated circuit for the very reason that your encountering. Sometimes if you use a heavy duty extention cord you can find a circuit thats not used very much to plug into. Extention cords run in ... Gibson Thru-Wall/Window Air Conditioner

I have a Goodman home A/C unit and the copper line coming into the house freezes up. The unit continues to run with no cold air. I was told it is either dirty or low on Freon. Are they correct? If it is low on Freon is this something that I can do myself. Thanks.


HelloIf you have ice on bigger copper line and no cooling then the unit is low in freon.As far as cleaning it,you should clean the outside condenser in the spring.Use some simple green and a hose to clean the coils,this will make it ... Air Conditioners

Goodman CKL60-1L The AC unit has ice on the coil leading to the house. The central core under fan has ice on it as well. The house is not getting barely getting cool. I would turn the AC on during the day and turn the system all the way off at night could this have caused the icing and air blockage?


All the above and it might need a bigger return on your a/c vary how big is your unit approx 16 min to 20 in. return air flow ... Goodman CKL60AR60 Air Conditioner

Hi there, I have two Fujitsu DC Inverter split units to heat my flat (england). The temperatures have dropped significantly -2 and below. This causes the outlet pipes to freeze up and when the units are on defrost the excess water gushes out of all other joints in the units. This causes two problems - the units are wall mounted one on top of the other, so the top unit freezes the bottom unit. The second problem is the bottom unit 'dumps' in on the floor of the area which when defrosted s


Normal cool temp 23 to 25 and heat mode 29 to 31. And regrading defrosting your pipelines no need any tray. You can insulate with Armaflex tube which is mostly used for best insulation. Hope there won't be further water leak. ... Air Conditioners

Goodman/Amana air handler freezing up and not cooling home. What could be causing it?


Hi,There are two things that cause freeze up's... Low air flow...Low freon...First check the filters, the blower , and the air vents to make sure that the air handler unit can move enough air...not enough air ... Amana Air Conditioners

Older coleman furnace in mobile home model 8631a was called by older couple who own it. Was told that standing pilot has gone out twice within two weeks never had problem before. Questioned owner if problem only seem to happen when trying to operate answer was yes (obviously) what could cause this ?


There is a coulpe of reasons that the pilot would go out.\015\0121. Thermocouple is dirty, try cleaning it. \015\0122. Thermocouple is no in the pilot flame. Look and make sure it is directly in flame.\015\0123. Pilot dirty. Flame h ... Air Conditioners

I have a Hampton Bay window A/C model HBD160-E (Home Depot). It recently started tripping it's 15A circuit breaker. Has been plugged in to same outlet for going on 11 years. Other than this unit still works and cools fine. What could cause this?


Look at the serial tag. It should give you the amperage. If that is close to 15 Amp then the circuit breaker has obviously been running at an elevated temperature (due to its inherent resistance), and is now "worn out". You need a new breaker. If ... Air Conditioners

Our York P4HUB12N08001A furnace has an A/C unit installed and we are running it in cool mode for the summer. Yesterday, my wife noticed a repeated hum from the furnace, and the house was 4 degrees warmer than it should be. She said that it would hum a couple minutes, turn off, then repeat a little later. I told her to shut it off, and I'd look at it when I got home. With the two covers off the furnace, I returned power to it, then pressed the safety switch so I could see everything happening. Th


A fan capacitor can be bad 'without' showing any visible defects - so - I would 'First" try a new capacitor, be sure to take the old one (after you've marked the wires for easy re-wiring) and get an exact replacement.\015\012\015\012Howev ... Air Conditioners

Intertherm ac with heater for clayton mobile homes. water is leaking on floor from ac unit in house. the outside drain is dripping good so it does not appear to be a clogged drain.


Sounds like you may have freezing coil. Clean your filters and the inside of your coils. Also blow out the drain (just in case). Many people pour a cup of bleach in the drain pain once a month to keep the slime from growing. ... Air Conditioners

Where can I find a manual for my coleman cam II central air conditioner for a mobile home? I recently purchased the mobile home and would like to know what steps to ntake to make it work at its best. Also, I find it puzzling that the air filter is set on top of the unit inside the mobile home. It looks to my limited knowledge of central air, as if someone set the filter on top of the unit because they did'nt know the correct location placement. Can you provide any comments or advice? Thanks


Check the website for Coleman/Intertherm for a manual, you will need the model and serial numbers of the unit. The filters for these typically sit on top of the unit, some come with frames, some lay directly on the coil. If you can't find a manual on ... Coleman Air Conditioners

I've got an older Coleman Unit - Suncutter / Model #7442-815 that came with the mobile home when we bought it new. I've been told that it was just an A/C Unit, but the mobile home dealer added the Heat Package, (#7642-915). Last winter when we turned the heat on, it would blow for a short time and then trip the breaker in the unit. If you untripped(?) it, it would come back on. I'd LOVE to find the Owners/Users Manual for the unit. My husband is very capable, and can probably repair/replace


... Air Conditioners

Freezing up, home ac unit no air flow after running a while


A low freon level in the unit can cause them to freeze up. Are the fins behind the filter clean? ... Whirlwind FH-778 Air Conditioner

I want to connect 4 ton central ac to mobile home I have a license to connect ac units, but I have never done one in a mobile home. I have learned the hard way that things are done differently in homes than in mobile homes. Before I ask for inspection, I want to be sure I did it right.


Does the mobile home have a modular duct system? i have converted a mobile home from a split system to a package unit and all i did was wire the package system outside 240v and 24v thermostat and we connected the existing ductwork that was in the ho ... Air Conditioners

I have a goodman GSC 130301AB ac unit, outside my home and it stop working completely. What is most likely the cause?


... Goodman Air Conditioners

MY UNIT IS CREATING ALOT OF CONDENSATION. I HAVE TRIED SO MANY WAYS TO FIX THE PROBLEM. THIS UNIT IS INSTALLED IN A MOBILE HOME. I HAVE OWN THE MOBILE HOME FOR 6 YEARS. HELP!!!!


Air conditioners are SUPPOSED to make condensation. Lots of water means lots of good air conditioning :-)\015\012\015\012Do not fix it. It is not broken. ... Coleman Air Conditioners

Earlier this week, I noticed that the house felt "stuffy" but the thermostat showed everything to be cooling as expected. Last night, the house was definitely warmer than expected when we got home. My husband did some checking and found that the outside unit was running as normal, but there was no cool air coming through the vents inside the house. turning the a/c unit off at the thermostat did NOT turn off the outside unit...was only able to do this at the circuit breaker. It seems that the fan


If both fans runs (inside and outside), check if the compresor runs , if does probably the unit is low in freon and needs to be recharged after the freon leak has been fixed (remember this is a seal system and it shouldn't leak), but if the compresso ... Ruud UBHC Air Conditioner

A detailed question is important to get you a relevant answers