Having problems with your Air Conditioners ?

I have the Mitsubishi split unit system with 24BTU for my bedroom, the problems starts after the compressor has started and the cold air has been blown through the indoor unit, this pleasure lasts for about 2 mins and then a strange sound from the outdoor unit , sounds like the power is getting low or some what, then it shuts itself down. A technician checked and said the compressor needs replacement..its 12 month old and works 6 hours a day!!!


Answers :

Ok, it can be two things.
\015\012
    \015\012
  1. The outside unit needs to be washed with a water hose to rinse any dirt and debris that can cause a restriction in airflow over the outdoor coils. If they are allowed to get dirty, they can cause the compressor to overheat and shut down on thermal lockout.
  2. \015\012
  3. The unit has a small refrigerant leak and the unit doesn't have sufficient refrigerant for the system to run thus causing the compressor to shut down on thermal lockout. The problem with this one is that generally the inside coil will freeze up and you will notice that.
\015\012Compressors generally won't come on at all if they are bad. You can have a compressor go bad and still be running, but it won't cool at all. A bad install can cause a compressor to fail as well. Generally if the compressor fails within the first 10 years, you can bet it's because it was a poor install. This means that a proper vacuum wasn't pulled on the unit before initial start-up. Hope this helps.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

I have a Lennox model CB19-51-1P air handling unit with HP19-511-1P compressor heat pump unit. I just turned the heat on for the first time this season. And I am getting low heat volume. The heat pump unit is running for long periods. I am getting enough heat to maintain the 70 degrees setting with constant cycles, shutting off for short periods, running long periods. When the thermostat is turned to a cooler temperature, the unit shuts off as it should. Could you please help trouble shoot po


First thing you need to check is if the reversing valve is working you maybe running your A/C with the heat strips on depends on the t-stat your using some heat pumps will bring the strips on with a high d ... Air Conditioners

I have the Mitsubishi split unit system with 24BTU for my bedroom, the problems starts after the compressor has started and the cold air has been blown through the indoor unit, this pleasure lasts for about 2 mins and then a strange sound from the outdoor unit , sounds like the power is getting low or some what, then it shuts itself down. A technician checked and said the compressor needs replacement..its 12 month old and works 6 hours a day!!!


Ok, it can be two things. \015\012\015\012The outside unit needs to be washed with a water hose to rinse any dirt and debris that can cause a restriction in airflow over the outdoor coils. If they are allowed ... Mitsubishi MSM18NW Air Conditioner

Heat pump shut off 1 to 2 minutes, service yesterday for same problem told low on freon. Added freon, worked fine until it went thorugh first defrost, now back to same thing. Tech says compressor not getting signal from thermostat. After resetting T-stat, unit came on. Unit works on cooling and Aux heat, but no heat pump.


It is possible that you have one or a combination of a few different problems here.If your heat pump will not come on but the air handler works, the first thing you want to check is that the circuit breaker and disconnect for the heat pum ... Carrier Air Conditioners

48xp my carrier 48xp-060090311, has a slow down mode with blower to keep blowing after compressor shuts off. It suppose to slows down and keep blowing at a slower speed so as to save money by having air blow across coils. It does not slow down now and compressor stays on for long time. Some times it gets warm other times I have to raise temp. to get unit to shut as it gets too cold.


... Air Conditioners

My unit's compressor will intermittantly stop working. The thermostat seems to keep the intake unit working but since it can't get the temperature down it never shuts off. We have been removing the batteries and letting the thermostat reset for 20 minutes. (thermostat Honeywell RTH23110B). After the reset the compressor will work again but will fault within a day. I am pretty sure that the compressor and fan are functional as if I press the contactor down it begans functioning. I also, to he


If the air handler coil is clogh , the air won't go through and the compresor will shut off on overload because of high head pressure, also this will happend if the condenser coil (outside) is blocked or if the fan dosn't work .Also if the outdoor un ... Air Conditioners

Have air conditioner that freezes up after setting it on the lowest setting. checked the freon on the unit and the suction pressure was at 42 on the 22 scale & about 70 on the psi scale, low side. no high side tap to get reading. fan motor very hot, rpm? have some #'s off of the unit 12078 ace244pt3/201s170001562.... compressor make / modle.. HIGHLY SHW73TC2GP1 ...4390H1793741 WHAT SHOULD THE LOW SIDE READ ON THIS UNIT ACCORDING TO DESIGN SPECS& SHOULD THE MOTOR BE SO HOT YOU CAN'T KEEP YOUR HAN


If it's freezing up, chances are the freon is low, but read the info on the panel near the taps or the compressor to find out how much you should have. you need r-22 (if that is what it takes), guages, a thermometer for dry and wet, a temperature se ... Whirlpool Air Conditioners

I have a 10 ton ac unit with a internal air handler. I am not getting any low voltage to the 24volt coil at air handler. I can manual pull in the coil two get it two work. I am getting 240 volts at the controls out for the compressor but not showing any low voltage comeing from there either????


Ok, it would appear that the 24v contactor voltage has faulted. you need to trace the wire right back to the Controller, & then on to transformer/power supply. You must work back, until you find, a point where the voltage IS present. I think you ... Air Conditioners

Can not turn the unit off with the power switch. The compressor on my Haier AC will not shut off, even in the power off position, I have to unplug the unit to get the compressor to stop. The AC stil


Relay in controller stuck closed. new controller required - may be a pcb type that can be fixed with a new relay ... Haier Air Conditioners

I have a 1993 yellowstone camper with a coleman wall thermostat. on the bottom of it- it has a heat/cool switch on one side and the other side has a low-high-fan switch. when we run it on low or high it gets cool but the fan never shuts off.if we put it on fan it shuts off with the compressor but it doesn't blow cool air. any advise?


Thank you so very much for your answer! I'm glad I came to this website before I began a new project. I was about to re-wire my unit based on my ex-husbands advice!!!! ... Coleman Air Conditioners

I have a shenbao mennelium aircon its gets cool after i turn the unit on but after 10-15 min it stops blowing cold air i have to shut the unit off and then back on to get cold air and also the compressor fan makes noises but still spins it sounds like it need greese


Check the fan,to make sure it is really turning fast on the high mode with ac on,not just fan.It sounds like the fan is slowing down,and not cooling the condenser,therefore cause the head pressure to rise,and producing warm air.The fan motor would ha ... Air Conditioners

My coleman 13,500 roof a/c year 2000 does not blow as cold as used to. I have cleaned the top condenser coils, with no help. It also at times will seem to pull a heavy load when I assume the compressor kicks in, very heavy that the generator bogs way down, then runs free, i believe the compressor is shutting down as cooling worsens, it was 85 outside and the coach continued to get warmer. The AC unit has shut down completely before, not sure why I waited 30 minutes and it restarted.


If the compressor started and stoped means \015\0121 thermostat need settings \015\0122 compressor over heated due to low suction pressure need to check and repair the leak then charge the freon ... Coleman Mach III Air Conditioner

I have a Comfort-Aire Model RAH-123A Room Air Conditioner and Heat Pump. When depressing the low or high heat control button, the unit hums like it wants to start but shuts off in about 3-5 seconds. My suspicion is that the compressor is trying to start but a thermal cutout shuts it down when it does not start. The unit was installed as part of a sun room addition and the remodeler is no longer in business. If I cannot solve this problem through the internet, I need a local contact fro servic


Hi!\015\012Before I give you a possible solution to your problem you need to check the heating temperature Control, set it to a warmer setting, if problem persists, check the power cord.\015\012\015\012To test your power supply cord:\015\012\0 ... Air Conditioners

The outside compressor and fan will not shut off. I have turned the thermostat system to Off and even to heat, but it will not stop. I went on a trip, increased the room temp to 80 on the thermostat and left. When we returned 2 1/2 days later, the coils were frozen and no air was comiing through the vents, even with the blower motor working. So I turned the unit to furnace and melted the ice on the coils, but had to pull the fuses on the outside box to get the compressor to shut off. Is there a


Sounds like the contactor is stuck. That's why nothing will stop the fan and compressor except killing the power to it. You should be able to get one fairly cheap. ... Ruud UAKA037 Air Conditioner

I have a duo therm a/c roof top unit that is not cooling properly it has been approx 2 years since the unit has been run I have checked breakers and fuses in breaker box I removed the cover from unit the compressor is running and getting hot the lines are cool but not cold the fan is running I am thinking that the unit is low on freon can some type of self tapping ports be installed to add freon or have ports soldered in place or could there be another underlying problem that can be checked or i


You have a leak in the system that needs repair. If you have to add freon to system there is a leak. You need a service tech to do the repair. If it is out of gas you may to replace it. Leaks do not correct themselves. Russ ... Dometic Rooftop RV Air Conditioner

Dometic roof top AC unit compressor turns on even if T-stat is off. Only way to get the compressor from turning on is to turn the breaker off. Unhooked T-stat wires to see if issue was there but the compressor still kicks on when I turn the breaker back on. If I leave the auto t-stat on, the compressor will turn on for a bit with a loud hum until after a couple minutes or more it shuts off with a loud thud that will shake the RV. Then after a while it will do it again. Only let it happen twice


Sounds like you may have a couple of problems there. First, have you checked incoming voltage to make sure you are getting 100-120 VAC at the AC control board in ceiling? If that's ok, try removing/disconnecting Ac compressor wire at ceiling control ... Dometic Rooftop RV Air Conditioner

SHARP Inverter Split Type A/C: Turns on, but the compressors shuts down after less than a minute. Diagnostic LED (at ourdoor unit control board) indicates 'AC abnormal current'. Measured current on compressor (R S C) reaches 3.4A max then it turns off. Please help. Noted also that the copper tubing of the refrigerant gets cold for a while. Compressor gradually increases speed before shuting down. Please help.


Pull wires off compressor. Check contnuity between the \015\012R and S. \015\012R and C, \015\012S and C\015\012The two lowest numbers should add up to the highest number reading. (Example. 3.4 Between R and S\015\0121.2 ... Sharp Air Conditioners

Model Indoor Unit RAVSM800KRTE Outdoor Unit RAVSM800ATE The air conditioner runs for 20 minutes the shuts of and the operation led light flashes green, the time light flashes yellow the def light flashes organe/red we have had the outdoor unit checked and the compressor and pcb is suppose to be okay but the technician cant get any help to diagnose what the problem is


... Air Conditioners

OUT SIDE UNIT SHUT DOWN IN HEAT MODE, WHEN YOU FIRST TURN IT ON IT RUNNS FOR ABOUT 30 SECONDS THEN BOTH THE COMPRESSOR AND FAN SHUT OFF FOR APROX 3 MINUTES {LARGE LINE STARTS TO GET WARM} AFTER 3 MINUTES BOTH START BACK UP BUT ON RUNN FOR 5 OR SO SECONDS THEN KICK OFF AGAIN, SERVICE TECH. BLED PRESURE VALVE WORK FOR LESS THAN A DAY, HE CAME BACK AND BLED IT AGAIN WORKED FOR LESS THAN A DAY,


Hi, You have a heat-pump, this I do no. The reason it is shutting down from how you have explained it to me, is the compressor is shutting down due to high pressure and it is going off on the internal overload. When the compressor cools down, it star ... Air Conditioners

My central air conditioner is making a whistling noise in the inside unit when the compressor is running. It's not the blower because the noise stops after the outdoor unit shuts off. It's also not blowing any cold air and the piping is not getting cold. What could be the possible cause?


Hello,\012\012If there is no cooling (meaning no cold pipes and not blowing cold air) then check the outdoor A/C for any visible/obvious issues; breakers not tripped, no debris blocking the outside unit from passing air through it, etc. If all ... Air Conditioners

Im trying to hook up the wireing on a wirlpool 110 window unit. i want to know if it is hooked up right,. i changed the motor and now the compressor kicks on just long enough to blow cold then shuts off. It did blow cold as hell. now it get to the cold part and shuts off. what can i do?


Hello, locate and move the thermostat sensor end(bulb) to a different location. ... Air Conditioners

Hello there. I have Friedrich wallmaster a.c ws16b30-a for about five years, a month ago it started not to cool enough, then i called service, the service guy cleaned the coil and recharged compresor with freon after finding that it was only 30% on freon. It worked good for about two weeks and now problem started again. Now compressor works for about a minute or two and than shuts-off releasin wery hot air on the back of unit and compressor itself gets very hot. Can somone tell me what kind of s


Hi,As it is already 5 years old, there could be many problems. Yes, freon is the main fault. Other than this, i would doubt freon leak. These AC's are more prone to freon air. I have no idea whether the repairman checked it for freon air. ... Friedrich WallMaster WS07A10D Air Conditioner

I bought a brand new Duo Thermo rv ac unit and I am having a issue with the compressor. I have it running all day and it works fine, but when it is running at night the compressor shuts down frequently and it gets so hot inside. Is this something that is normal.


Hi,Yes, the Air conditioner system is a bit low in charge, so when the air cools outside it drops the gas pressure too low and then the lose of charge switch cuts out till the pressure raises then it comes on again..The best thing w ... Dometic Rooftop RV Air Conditioner

We have a 16 yr old basic 4 ton Carrier unit. Coolant was a little low when started it up this spring. Had it recharged but now believe there is a slow leak in the coil. Is this usually repairable? Could the compressor get damaged if it runs to low on coolant? And can the coolant leak fumes be harmful when inside the house? Thanks


If it has a small leak, it might be a pain to find but it is possible and yes it can damage the compressor. Also it can be harmful as it will displace oxygen. It's not combustible though. ... Air Conditioners

I have a Duo-Therm Penguin model#610115405 that cools and the fan changes speed(slower) when the room gets cooled and the compressor kicks out, but the fan will not shut down.I have the same unit fwd in my RV that works fine. I tried switching the thermostat,ptcr relay and the capacitor that is below the ptcr. Any other suggestions ? Dont see anything that else that I can easily switch to check.Still not shutting down?


Hi,\015\012the relay that is suppling the power to the fan is welded shut and is not opening. This often happens with relays, the contacts get pitted and then they heat up and weld fast. The relays that run the fan faster and slower are still w ... Dometic Rooftop RV Air Conditioner

Unit will cool for about 10 minutes and then compressor shuts off an unit blows warm air for about 10 minutes and compressor will start again blowing cool air and then compressor will shut down again and unit will blow warm air ... etc. the unit is running off a generator to cool down a 10x14 enclosed trailer and does not do the job of cooling


... Haier CPN10XCJ Air Conditioner

A detailed question is important to get you a relevant answers

  • Start your question with What, Why, How, When, etc. and end with a "?"
  • Be clear and specific