Clicking noise at the gas valve/pilot light unit

\015 My heater when running works fine. At the end of the heating cycle I get a loud clicking sound coming from the gas manifold/regulator unit. It sounds like it is trying to relight the gas. I have to turn down the thermostat the stop it.\015

Answers :

It sounds like you might have a spark igniter on the unit that is being told to relight the burners. This is probably the tstat as this is the only control that "tells" the unit to come on. There isn't anything else internally that will cause this problem. Replace your tstat and I bet this solves your problem.

Repair Help & Product Troubleshooting for Air Conditioners
You need a second opinion or clarification ? ask it in the comment box OR you can Ask Your Own Question

Tips for a great answer:

  • Please provide as much detail as possible as this will allow our members to better understand and respond to your Comment
  • If you need clarification, ask it in the comment box
  • It's 100% free, no registration required

Suggested Questions/Answers :

It is recommended you read all this kind of situations

Clicking noise at the gas valve/pilot light unit


It sounds like you might have a spark igniter on the unit that is being told to relight the burners. This is probably the tstat as this is the only control that "tells" the unit to come on. There isn't anything else internally that will cause this ... Carrier 38BRC048 Air Conditioner

Carrier Model #48SDN060115301 will not heat. The unit clicks and gas is injected but it does not light. I have the side panel off and the red indicator light is solid red indicating that all is well. The fan runs, gas is good,clicks, just no spark.


The tech that I spoke with knew less than I did about this problem. I had to try an lead him threw what was going on. He ended up telling me that it was the igniter which it was not. It was the main board which was not sending a spark. As Carrier wil ... Carrier Air Conditioners

Dura-Glo Centurion Model 48 gas fireplace gas valve not letting pilot stay on; has new Tpile, which is activating valve (I can hear click internally when I hook up leads from hot Tpile. Unit wasn't used for quite a while and was found in "pilot" position but not lit. upon re-lighting (long manual hold time) started working properly. We thought maybe intermittent wind blowout, but then Tcouple quit making juice. Replaced, but now just a click from inside valve. I haven't found any tags on the va


Ed, when you installed the new Thermocouple did you finer tighten and just 1/4 turn more with a wrench? Or did you tighten it more than that? If you did over tighten it, the Thermocouple probably locked up the control valve. Unscrew it, give it a co ... Air Conditioners

I have a Haward H series H400 gas heater and it just started making loud clicking noises and the unit shakes when i turn the heater on. When i shut it off and restart it is ok for a while but then the noises return. any answers?


First of all check the water flow through the heater.If its low that is the problem of unit shaking.also check the hoses if the hoses are blocked or loose this may block the flow of water.\012The clicking indicates problem with motor ,motor bea ... Air Conditioners

My Intertherm, electric ignition furnace will hum and hum but not click on. There are two yello flashing lights until we reset it by turning off the gas and turning down the thermostat. The unit resets itself and I get a steady red light when its working. Is this a pressure switch issue?


That blinking yellow light is an error code. If you look behind the main cover there will be a wiring diagram and error code chart. This will give you an idea what the problem is. ... Air Conditioners

I have a Bryant package unit that clicks when I put in the fuses. It is not a loud click that you would expect with a gas valve however. The light on the furnace control is flashing 6 times.


The codes are generally printed on the back of the bottom cover on residential units (blower section). On light commercial, the cover for the controls section (follow the line voltage and thermostat wires.\015\012 Off the cuff, if it has a sparker, t ... Air Conditioners

SW6DEA GAS HEATER UNIT FLAME WILL NOT STAY ALIGHT ! Switching gas water heater unit on inside the RV, the red light comes on and approx 6 to 8 seconds later ( normal time cycle ) the gas flame lights up OK but goes out again after approx. 6 to 8 seconds with the red light going out at the same time. Leaving the unit switched on inside the RV, after a further 6 to 8 seconds, the red light comes back on automatically and repeats the start up cycle over - again without success. *4 times unsucces


... Air Conditioners

No A/C My unit will power on and the fan works, however when I turn it to the Cool mode I can hear a click in the unit, the cool light comes on for 5 seconds or less, then it will click again and the light will flash 9 times. The warranty on the unit is 4 years however only covers parts, labor is $90 per hour......Is it just a fuseable link/circuit breaker?


It seems that that the overload of compressor is tripping on and off, either your compressor overload is defective or the compressor itself ... Danby DPAC8399 Air Conditioner

Central AC makes loud noise at start up (inside unit, not outdoor unit). The noise has been getting longer and now the AC doesn't click on.


... Air Conditioners

Outside unit clicks while thermostat auxiliary light flashes


Sounds like the compressor starting relay or capacitor is defective. When the compressor could not start, the electric heat came on to satisfy the heat requirement and causing the emergency heat light to come on at the thermostat. This light warns y ... Ruud Handler Air Conditioner

Model PE1-09R-30 SoleusAir Portable Air Conditioner: Power Plug in light flashes on and off and clicks when reset. Test button turns light and clicking off. On/off switch on unit does not turn fan off when power is on with plug light flashing and clicking. It does turn display lights and on and off.


Hi,\015\012This is the link to download the service manual for your product. Hope it will be helpful to you. \015\012http://www.managemylife.com ... Soleus Air Conditioners

I have a Goodman Furnace model#GDS80703AXBC.The unit is one year old and ran fine until the gas got shut off accidently outside at the meter.Unit was cycling with no gas for 2 days.we turned the gas back on and the unit is showing one light blinking for over cycle trys.The unit did eventually start up but it does not fire up after each time the thermostat is calling for heat.The unit has been running like this for about 10 days now.I have replaced the Diagnostic computer, glow igniter,flame sens


The only part not replaced so far is the gas valve. Because the gas valve is getting power does not mean it is opening.You could also have gotten trash(corrosion/scale) in the valve orifice and or the burner orifices.Is there a drip ... Goodman Air Conditioners

When unit is turned on the operation and indicator light are solid for about a minute then the indicator light goes off and the operation light flashes. The outdoor part of the unit does not seem to be switching on ( no noise or fan). Outside unit has power. Filters are clean.


It's communication error between indoor and out door unit.Comms Error, check your wiring, remove external pumps. Split/Multi - check volts from terminal N to 3 = 0 - 65 Vdc, Multi V - 4 Vdc terminals 3 and 4 ... Mitsubishi Air Conditioners

Brivis Wombat 92 heating unit - I am having trouble getting the pilot light to stay lit. The gas is on, the igniter is sparking and the pilot light ignites but when I gently release the red gas valve after 60 seconds as prescribed in instructions the pilot light flame extinguishes itself. Have tried venting the gas line to get rid of oxygen and this isn't helping. Any ideas?


Hear of a PRIMUS pricker?This is a very stiff but fine wire that was used to clear the jet on an old primus stove. The gas jet head at the pilot has a fine hole to allow gas to flow. When you hold it open with the button it allows for the ... Air Conditioners

Last night my husband turned off our window unit because it had gotten cold in the house, we got up this morning and went to turn the unit on and it won't come on at all. The light on the plug is on and when I click the reset button it lights up everything on the front panel but it turns itself back off. We always have to replace window units every year and this is quite costly and am getting tired of this. We have 3 other units that are older than this one which is only a year old but we also p


Must be a shorted capacitor. ... Air Conditioners

Hi , I have a Electronic pilot lighting system on my RUUD package unit. The pilot light flame keeps blowing out or is not working properly. I removed the panel to look and see what was wrong. I could not see any faults. The sparker worked just fine, the gas line tubing was fine no blockages( took it off to inspect it) every thing looked good. Worked fine for the last couple of weeks and now it will not ignite the pilot light to light the rest of the propane gas to heat the house. I tested the fl


Sounds like you have checked most things. A pilot will go out if it is dirty, if the gas valve is not holding or if the senser is dirty or bad. Remove the pilot and clean out the small orifice inside. Check all electrical connections, clean the senso ... Ruud UBHC Air Conditioner

I have a mitsubishi air conditioning unit model MUH-12v. The fan on the machine outside has stopped and of course inside the air is not cold. Could this be a problem with replacing the gas or could it be a technical problem with the outdoor unit. Also I have noticed when I switch on the unit on the inside with the remote control that instead of two green lights comimg on I only have one green light flashing. Does that mean anything?


Hi,Here is a tip about Mitsubishi Air Conditioners and how to get the manuals for all of the mitsubishi line. The manual include both troubleshooting and installation. ... Air Conditioners

I have a 10 SEER heat pump about 16 years old, yesterday I notice that the outside unit was making a loud click noise in the heating mode. It's very close to the defrost electrical curcuit board. The unit still was putting out heat inside but decided to turn off the unit and use the emerg. heating. What could that loud clicking sound be? concern, Gilbert


Depending on make and model sounds like a check valve clicking. It can sound like it is coming from that area. You say your unit is 16 years old. Honeywell did servey on unit 10 years and older and found out they loose 25% effeicency after 10 years. ... Air Conditioners

I have a frigidare gas heating unit aprox 8 yrs old. the problem is the unit comes on the ignitor heats up gas comes on and lights but the gas only stays on about 5 seconds then shuts off?


You have a flame proving device that senses the flame. It is located on the last burner in line looks like a piece of thick wire. Take some steel wool and gently rub the outer surface 4 or 5 strokes is all it takes to remove the carbon that has bui ... Frigidaire Air Conditioners

I HAVE A RUUD SILHOUETTE GAS FURNANCE. The pilot light keeps blowing out. When I light the pilot flame it seems to work perfectly at ignition. As the Manual instructs, I hold down the ignition switch for 30-60secs to keep the flame lit and then turn the gas switch to the on position. After watching the unit I have noted this happening - the furnance will begin the heat cycle sequence and pilot litghs all 4 burners correctly, the blower fan turns on, Heating starts. But after a short period, the


Short answer, yes. However you could have another problem. Replace the thermocouple that keeps the pilot lit. You can get a universal one at any good hardware or farm store. Make sure the new thermocouple is well into the pilot flame. If the blower ... Ruud UBHC Air Conditioner

My central heater is not blowing hot air, I am having to turn the thermostat on and off. I have the thermostat to 70, and the heater will blow hot air and then it will just circulate the air in the house, therefore bringing the temperature down. I looked at the unit and noticed that when the thermocople (heating element) goes red, the gas valve makes clicking and the flames come and then go out very fast. I noticed lots of clicking in coming from the gas valve. help please


Hi!!! relax your flame sensor is bad change and you will be fine..If it turns off and on change your flame sensor ... Air Conditioners

We have gas running through the unit, but the flint isn't igniting the gas. This continues approximately 3 times and the unit goes into safety, with a red light blinking slowly and steadily.


You have to have pilot before the main burner ignition or flame sensor problem. ... Air Conditioners

Ductless split system, single zone, gives trouble display. Operation light flashes 6 times rapidly, then both Operation and Timer lights flash 5 times at 1 second intervals, then the timer flashes 1 time at 1 second interval. What do we do? The unit doesn't put out heat. I only feel air when I click the Coil Dry Button, but the Trouble Display continues. Unit will not shut down. I flipped the main switch, connected to the heat pump, on the exterior of the house, but it started back u


What make and model is it? ... Air Conditioners

I have a Payne, Gas heat/Electric cooling unit, model# PY1PJB____, and apparently I need to replace the combustion blower wheel. When I turned it on 1st time this season, it made a very loud noise, and upon inspection, the blower wheel is completely rusted and 1/4 of the wheel is missing. Probably the loud noise. I have the maintenance manual for this unit. I just need to know where I can buy the part(s) I need to repair this. Looks like a simple repair, but do I need to replace the wheel o


Hi, you will need to replace the inducer/combustion motor as one assembly. If you know any contractors that have a c-20 or c-38 license, you could get it at any wholesales a/c & heating parts house. If not, you will need to buy one on the Internet, j ... Air Conditioners

My Carrier gas furnace (ser. 1903A41848) located in the attic, is five years old and suddenly won't light. IT cycles the fan when I cycle the power to the unit and seemingly attempts to ignite through 3 auto-attempts, (I can smell the gas), yet no continuous operation with heat occurs afterwards. Two lights exist on the exhaust vent both begin green yet one turns red after the ignition attempt. Please let me know your thoughts. -Doug


The igniters bad or if unit ignites the flame sensor is bad try this first ... Air Conditioners